Ecom Instruments Ex-Time 40 User manual

Ex-Time 40/50
Operating Instructions

12
Contents
1. Introduction 13
2. Safety Advice 13
3. Faults and Damage 13
4. Safety Regulations 14
5. Ex-Data 14
6. Technical Data 15
6.1 Table with type-tested batteries 15
7.
Use and Application / Operating Instructions 16
7.1 Commissioning 16
7.2 Changing the battery 16
7.3 Wall Mounting 17
7.4 Time Setting 17
8. Repairs 17
9. Cleaning, Maintenance and Storage 17
10. Disposal 17
11. Guarantee and Liability 18
12. EC-Declaration of conformity 18
13. EC Type Examination Certificate 19
14. Certificate of Compliance 23

13
Note:
The current operating instructions, EC Declaration of Conformity and
the Ex-certificate are available for download from the relevant product
page under www.ecom-ex.com, or alternatively they can be reque-
sted directly from the manufacturer.
1. Introduction
The Ex-Time 40 and the Ex-Time 50 are quartz movement wall clocks
designed for industrial application in areas with an increased risk of
explosion in zones 1 and 2, in accordance with directive 1999/92/EC
(ATEX 137).
2. Safety Advice
These Operating Instructions contain information and safety regulati-
ons which must be followed to ensure safe and reliable operation of
the unit under the described conditions. Failure to follow the informa-
tion and instructions contained in these Operating Instructions can
have dangerous consequences or may violate applicable rules and
regulations.
Please take the time to carefully read through these
Operating Instructions before you start using the unit.
In the event of any doubt or discrepancies (e.g. due to errors in trans-
lation and/or printing), the original German language version of the
Operating Instructions should be referred to.
3. Faults and Damage
If there is any reason to suspect that the safety or integrity of the unit
has been compromised, then it must be taken out of operation imme-
diately and removed from the Ex-zone without delay.
Precautionary measures must be taken in order to prevent any further
use of the unit in the Ex-zone. It is recommended that the unit should
be then sent to the manufacturer to be examined.
The safety and integrity of the unit may be compromised by,
for example:

14
-
External damage is evident on the housing.
- The unit has been subjected to excessive loads for which it is not designed.
- Incorrect storage of the unit.
- Damage sustained in transit.
- Correct certification is illegible.
- Functionality errors occur.
- Permitted tolerances or threshold values have been exceeded.
4. Safety Regulations
Use of this unit assumes that the operator observes conventional safe-
ty regulations and has read the certificate in order to eliminate faulty
operation of the unit.
The following safety regulations must be complied with:
- The housing of the quartz mechanism and the battery
- compartment must not be opened within the Ex-zone.
- The battery must only be changed outside of the Ex-zone.
- Additional or spare batteries must not be carried in the Ex-zone.
- Only the "type-approved” batteries as listed in these Operating - -
- Instructions may be used.
- Ensure that Ex-Time 40 and 50 units are securely attached
- to the wall.
-
It must be ensured that the clock does not accidentally fall into zone 0.
- The clock should only be cleaned with a damp cloth.
5. Ex-Data
EC Certificate of Conformity no.: PTB 02 ATEX 2197 X
Ex-Designation
II 2 G Ex ia IIC T4
Approved for areas classified as zones 2 and 1, device group II,
Explosion group IIC potentially explosive gases, vapours or mist,
temperature class T4

15
Report job identification no.: 3015562
FM identification: I.S. Class I Division 1 Group A-D T4
Intrinsically safe for use in a Class I, Division 1, Groups A, B, C & D
with a Temperature Class of T4 hazardous (classified) locations.
6. Technical Data
Ambient temperature Ta: 0°C ... +50°C
Storage temperature: 0°C ... +50°C
Battery / power supply: 1 x LR14 acc. to IEC
Battery operating time: approx 2 years
Accuracy of quartz mechanism:
+15/-5 seconds per month
Dimensions: 400 x 60 mm / 500 x 70 mm
Weight (incl. batteries): 2.5 kg / 3.5 kg
CE labelling: 0102
6.1
Table with type-approved batteries
Manufacturer Type
Varta High Energy No.4914
Varta Industrial Alkaline No.4014
Rayovac Maximum Plus LR14
Duracell Plus Alkaline MN1400
Duracell Procell Alkaline MN1400
Panasonic Powerline Industrial Alkaline LR14

16
7. Use and Application / Operating Instructions
Before use, please read these operating instructions very carefully
in order to familiarise yourself with the functions of the Ex-Time 40 /
Ex-Time 50. For you own safety and information, please read the follo-
wing instructions.
7.1 Commissioning
Use an appropriate screwdriver to undo the two screws on the battery
compartment cover (on the opposite side from the quartz mechanism).
Remove the battery compartment cover and insert a battery of the cor-
rect type (LR14) (refer to the table under section 6.1 – Table with type-
approved batteries ) into the battery compartment. Please refer to the
diagram on the housing to make sure that battery is inserted with the
correct polarity. Refit the battery compartment cover (the spring faces
towards the battery), refit the battery compartment cover screws and
tighten securely. Then use the white adjusting wheel on the housing of
the clockwork mechanism in order to set the correct time.
7.2 Changing the battery
To change the battery, use an appropriate screwdriver to undo the two
screws on the battery compartment cover. Remove the battery com-
partment cover and dispose of the old battery.
Insert a new battery (only use type-approved batteries ‘ refer to the
table under section 6.1 – Table with type-approved batteries; check for
correct polarity ‘ check the diagram on the battery housing ). Refit the
cover to the battery compartment (the spring faces towards the batte-
ry) and secure it with the two screws. The clock will now start to run
again. Then use the white adjusting wheel on the housing of the quartz
mechanism in order to set the correct time.
Please ensure that all used and defective batteries are properly dis-
posed of in an environmentally friendly manner.

17
7.3 Wall Mounting
An integral metal bracket located on the rear of the clock enables the
Ex-Time 40 / Ex-Time 50 to be suitably mounted on an appropriate
wall. The fixing of the unit must be secure at all times and precautiona-
ry measures must be taken to prevent the Ex-Time 40 / 50 from falling
into an area classified as zone 0.
7.4 Time Setting
The white adjusting wheel on the quartz mechanism is used to make
any necessary time adjustments.
8. Repairs
Repair work is subject to the nationally valid regulations and directives.
We therefore recommend that such work be performed by ecom
instruments GmbH, Germany, as all repairs must be examined to ensu-
re functional safety.
9. Disposal
Old electrical devices as well as „historical“ old electrical devices from
ecom instruments GmbH are supplied for disposal at our expense and
disposed of free of charge in accordance with European Directive
2002/96/EC and the German electrical law of 16/03/2005. The costs asso-
ciated with returning devices to ecom instruments GmbH are to be borne
by the sender.
10. Cleaning, Maintenance and Storage
- The entire back face of the unit must only be cleaned with a damp
cloth
- Do not use solvents or abrasive cleaning agents to clean the unit.
- The batteries should be taken out of the unit if it is to be out of use
for a length of time.
- The storage temperature should be within the permitted range of
0°C to +50°C.

18
11. Guarantee and Liability
As per the general terms and conditions of business, ecom instruments
GmbH offers a 2-year warranty for the functioning and materials of this
product under the specified operating and maintenance conditions.
This does not cover all wearing parts (e.g. batteries and lamps).
This warranty does not extend to products that have been used impro-
perly, altered, used negligently, damaged by accident or subjected to
abnormal operating conditions or improper handling.
Warranty claims can be asserted by sending the defective device. We
reserve the right to re-calibrate, repair or replace the device.
The above warranty terms represent the sole rights of the purchaser for
compensation and apply exclusively and in place of all other contractu-
al or statutory warranty obligations. ecom instruments GmbH does not
accept liability for specific, direct, indirect, incidental or consequential
damages or losses, including the loss of data, regardless of whether
they are caused by breach of warranty, lawful or unlawful actions,
actions in good faith or other actions.
If the restriction of statutory warranty and the exclusion or restriction of
incidental or consequential damages is unlawful in certain countries,
then it may be possible that the above restrictions and exclusions do
not apply for all purchasers. If any clause in these warranty terms is
found to be invalid or unenforceable by a competent court, then such
a judgement shall not affect the validity or enforceability of any other
clause contained in these warranty terms.
12.
.EC-Declaration of conformity
Further details relating to the
declaration of conformity can be found at the
following Website http://www.ecom-ex.com in the Products Download area.

19
13. EC Type Examination Certificate
Physikalisch-Technische Bundesanstalt
Braunschweig und Berlin
(1) EC-Type-Examination Certificate
(2) Equipment and Protective Systems Intended for Use in Potentially
Explosive Atmospheres – Directive 94/9/EC
(3) EC-Type-Examination Certificate Number
PTB 02 ATEX 2197 X
(4) Device: Explosion-proof Wall Clock, type Ex-time **
(5) Manufacturer: ecom instruments GmbH
(6) Address: Industriestrasse 2, 97959 Assamstadt, Germany
(7) The design of this device and any acceptable variation thereto are specified
in the schedule to this certificate and the documents therein referred to.
(8) The Physikalisch-Technische Bundesanstalt, notified body No. 0102 in
accordance with Article 9 of the European Community Council Directive of
March 23, 1994 (94/9/EC), certifies that this device has been found to
comply with the Essential Health and Safety Requirements relating to the
design and construction of equipment and protective systems intended for
use in potentially explosive atmospheres, given in Annex II to the directive.
The examination and test results are recorded in the confidential report
PTB Ex 02-22330.
(9) Compliance with the Essential Health and Safety Requirements has been
assured by compliance with
EN 50014:1997 + A1 + A2 EN 50020: 1994
(10) If there is an "X” after the certificate number, special conditions for the safe
use of the device are provided in the schedule to this certificate.
(11) This EC-Type-Examination Certificate relates only to the design and
examination of the specified device in accordance with Directive 94/9/EC.
Further requirements of this directive apply to the manufacture and supply
of the device. These requirements are not covered by this certificate.
(12) The labeling of this device must include the following information:
II 2 G EEx ia IIC T4

(13) S c h e d u l e
(14) EC-Type-Examination Certificate PTB 02 ATEX 2197 X
(15) Device Description
The explosion-proof wall clock, type Ex-Time ** can be used in potentially
explosive atmospheres.
The admissible ambient temperature range is 0°C - 50°C.
Electrical Data
Auxiliary power.................. Battery 1.5 V model LR14 (see (17))
Feed circuit........................ in ignition protection class for
intrinsic safety EEx ia IIC
Maximum values:
Uo = 1.5 V
Io = 866 mA
Po = 60 mW
for clockwork connection
(16) Examination Report PTB Ex 02-22330
(17) Special Conditions
Only use battery types that are listed in the operating instructions
supplied with the device.
(18) Essential Safety and Health Requirements
are fulfilled in accordance with the above-mentioned directives
Certifying body for Explosion Protection
Braunschweig,
By the order of
Dr.-Ing. U. Johannsmeyer
Government Director
20

21
Physikalisch-Technische Bundesanstalt
Baunschweig und Berlin
1st AMENDMENT
in accordance with directive 94/9/EC, appendix III number 6
to EC type approval test certificate PTB 02 ATEX 2197 X
Device: Explosion-protected wall clock Ex-Time **
Designation: II 2 G EEx ia IIC T4
Manufacturer: ecom instruments GmbH
Address: Industriestraße 2, 97959 Assamstadt, Germany
Description of the amendments and alterations
The Ex-Time ** explosion-protected wall clock may be manufactured in the future in accordance
with the test documents specified in the test report. The alterations concern the internal and
external configuration.The electrical data, special conditions and all of the other details remain
unaffected and are also applicable for this 1st amendment.
Applied standards EN 50020:2002
Test report: PTB Ex 06-26307
Certification body for explosion protection Braunschweig, 6th December 2006
By order of
Dr.-Ing. U. Johannsmeyer
Director and professor
Page 1/1
EC type approval test certificates without a signature and seal are not valid.
This EC type approval test certificate may only be circulated without alteration.
Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
Physikalisch-Technische Bundesanstalt· Bundesallee 100 • 38116 Braunschweig. Germany

22
Physikalisch-Technische Bundesanstalt
Braunschweig und Berlin
2nd AMENDMENT
in accordance with directive 94/9/EC, appendix III number 6
to EC type approval test certificate PTB 02 ATEX 2197 X
Device: Explosion-protected wall clock Ex-Time **
Designation: II 2 G Ex ia IIC T4
Manufacturer: ecom instruments GmbH
Address: Industriestr. 2
97959 Assamstadt, Germany
Description of the amendments and alterations
The Ex-Time ** explosion-protected wall clock may be manufactured in the future in accor-
dance with the test documents specified in the test report.
The alterations concern the internal and external configuration.
The electrical data, special conditions, instructions for manufacture and use, as well as all of
the other information in the EC type approval test certificate remain unaffected.
Applied standards
EN 60079-0:2006 EN 60079-11:2007
Evaluation and test report: PTB Ex 09-29066
Certification sector for explosion protection Braunschweig, 9th October 2009
By order of
Dr.-Ing. U. Gerlach
Senior executive office
Page 1/1
EC type approval test certificates without a signature and seal are not valid.
This EC type approval test certificate may only be circulated without alteration.
Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
Physikalisch-Technische Bundesanstalt· Bundesallee 100 • 38116 Braunschweig • Germany

23
14. Certificate of Compliance

24

ecom instruments GmbH
·
Industriestr. 2 · 97959 Assamstadt · Germany
Tel.: + 49 (0) 62 94 / 42 24 0 · Fax: + 49 (0) 62 94 / 42 24 100
E-Mail: [email protected] · www.ecom-ex.com
PA000187 / 500 / 12/09
WEEE-Reg.-Nr. DE 934 99306
1820/1830AL01A02 12/09 Änderungen vorbehalten! Subject to change without notice!
Kommunikation
Mobile Computing
Portable Handlampen
Mess- & Kalibriertechnik
Communication
Torches/Flashlights
Mobile Computing
Measuring & Calibration
Copyright© 2009 ecom instruments GmbH.
Der Inhalt dieses Dokuments darf ohne vorherige schriftliche Genehmigung durch die ecom instruments
GmbH in keiner Form, weder ganz noch teilweise vervielfältigt, weitergegeben, verbreitet oder gespeichert
werden.
Der Inhalt dieses Dokuments wird so präsentiert, wie er aktuell vorliegt. Die ecom instruments GmbH
übernimmt weder ausdrücklich noch stillschweigend irgendeine Gewährleistung für die Richtigkeit oder
Vollständigkeit des Inhalts dieses
Dokuments, einschließlich, aber nicht beschränkt auf die still-
schweigende
Garantie der Markttauglichkeit und der Eignung für einen bestimmten Zweck, es sei denn,
anwendbare Gesetze oder Rechtsprechungen schreiben zwingend eine Haftung vor. Die ecom instruments
GmbH behält sich das Recht vor, jederzeit ohne vorhergie Ankündigung Änderungen an diesem Dokument
vorzunehmen oder das Dokument zurückzuziehen.
Copyright© 2009 ecom instruments GmbH.
The contents of this document, either in part or in their entirety, may not be reproduced, forwarded,
distributed or saved in any way without ecom instruments GmbH prior written consent.
The contents of this document are presented as they currently exist. ecom instruments GmbH does
not provide any express or tacit guarantee for the correctness or completeness of the contents of this
document, including, but not restricted to, the tacit guarantee of market suitability or fitness for a specific
purpose unless applicable laws or court decisions make liability mandatory. ecom instruments GmbH
reserves the right to make changes to this document or to withdraw it any time without prior notice.
Other manuals for Ex-Time 40
2
This manual suits for next models
1
Table of contents
Other Ecom Instruments Clock manuals
Popular Clock manuals by other brands

Claypaky
Claypaky C52163 operating instructions

Translux
Translux Fair-Play instruction manual

La Crosse
La Crosse 404-4525 manual

Technoline
Technoline WS 8118-IT instruction manual

Silvercrest
Silvercrest KH 2198 operating instructions

Pvelectronics
Pvelectronics Spectrum 18 Assembly instructions and user guide