Exhaust Air Heat Pump with CMEV www.ecovolt.ieH20 Installation Manual
INSTALLATION & OPERATION MANUAL
EXHAUST AIR HEAT PUMP FOR HOT WATER WITH
CONTINUOUS MECHANICAL EXTRACT VENTILATION

2Exhaust Air Heat Pump with CMEV
Thank you very much for purchasing our product, please keep this installation
manual in a safe place and refer to this manual before you install the product.
Important notice: Please read this manual carefully before you attempt to
install this product. Failure to do so may result in the product not working
according to its design.
mechanical and electrical industry.
Exhaust Air Heat Pump Hot Water
INSTALLATION & OPERATION MANUAL
CONTENTS
SAFETY PRECAUTIONS
GENERAL INFORMATION
PARTS NAMES
INSTALLATION
PLUMBING CONNECTIONS
ELECTRICAL CONNECTIONS
METHOD OF APPLICATION
CONTROLLER INSTRUCTIONS
COMMISSIONING
MAINTENANCE
AFTER SALE SERVICING
03
04
05
09
20

3
Exhaust Air Heat Pump with CMEV
Notes on the use of the product
01. Household electrics must have a reliable earth
connection.
02. This product must be protected with a residual
current device of adequate rating.
03. Do not interfere with any permanent instruction,
labels or warning plate attached to the external
cover of a this heat pump.
04. This product must only be installed by
and electrical industry.
05. Always comply with local wiring regulations.
06. Always engage with a trained professional
to relocate this product after it has been
professionally installed.
07. Maintenance and repair work must only
personnel.
08. The electrical connection to this product must
be via a 20A RCD/MCB or RCBO with a test
button function.
09. The
a double pole isolating switch located close
to the unit. The isolating switch must never
be covered up.
10. A One way isolating valve must be installed
on the cold water supply pipe for maintenance
purposes.
11. This appliance should never be used by children.
12. If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent
hazard.
Do not operate this heat pump in a wet room
such as a bathroom or unless it is housed
in a separate cupboard within that room.
Refrigerant R290 Warning
This appliance uses R290 (propane) refrigerant, which
-
rized person.
WARNING
If the refrigerant is leaking, switch off the unit at the
mains and contact the service agent.
DO not
this appliance.
NEVER
Avoid risk of injury from contact with
refrigerant if you notice a leak.
If you suspect the refrigerant is leaking then:
Do not smoke.
Do not operate electrical equipment. Isolate
the device. Call the service agent.
End of life recycling. Please consult your local recy-
cling centre for advice.
The refrigerant must not enter the atmosphere.
professional.
The H20 is designed for internal installation only.
Where a system has been installed internally or in an
unventilated room, the following parameters must be
observed so that should any refrigerant leak, it will
MINIMUM FLOOR AREA = 45m3, based off a charge
of 0.350Kg and allowable practical limit for R290
of 008Kg/M3 .
This unit is required
reliable earthing before
usage, otherwise might
cause death or injury.
WARNING RISK OF FIRE
SAFETY PRECAUTIONS

4Exhaust Air Heat Pump with CMEV
I. SPECIFICATION
MODEL ) POWER SUPPLY
EV-H20/180 83 620×1524 220V-240V/ 50Hz
EV-H20/270 94 620×1943 220V-240V/ 50Hz
II. APPEARANCE
III. FEATURES
ECOVOLT H20 EXHAUST AIR HOT WATER:
01. Quality built duplex stainless steel
water cylinder with 50mm factory
-
the storage of hot water.
02. Quality highl
-channel heat exchanger wrapped
in close contact with the cylinder
for thermal conductivity.
03. No contact between the refriger-
ant piping and the water for addi-
tional safety
GENERAL INFORMATION
DUPLEX SS TANK
ErP A++
R290
REFRIGERANT
HIGHEST EFFICIENCY IN IT’S CLASS
COMPLIANT
04. The maximum outlet water tem-
-
tion of the heat pump and auxil-
heating using the heat pump only
it is recommended that the hot wa-
05. The heat pump uses extracted
stale air from wet rooms delivered
by rigid or semi-rigid ducting and
connected using different meth-
ods as below. The air intake duct-
ing should be kept to a maximum
combined length of 20 meters.
For high performance buildings it
is recommended to install a sup-
ply duct connected to the outside
with an inline damper connected
to the damper signal cable. This
method will take energy from the
outside air as well as the internal
wet rooms.
06. Automatic and program modes
available.

5
Exhaust Air Heat Pump with CMEV
V. ILLUSTRATION
IV. REFRIGERANT CIRCUIT
Compressor GMCC/Toshiba - R290.
Evaporator
EEV Electronic expansion valve, the opening is regulated according
to the discharge air temperature of compressor.
Fan Centrifugal fan with three speeds.
Tank Duplex stainless steel.
Heat Exchanger
Electric Heater Dry Ceramic heating element with no direct contact with the water.
Controller Touch screen.
SAMPLY ONLY

6Exhaust Air Heat Pump with CMEV
ECOVOLT MODEL
POWER SUPPLY
0.57KW 0.57KW
2.9A 2.9A
2.4KW 2.4KW
1.5KW 1.5KW
6.9A 6.9A
12.0A 12.0A
REFRIGERANT
COMPRESSOR MIDEA
ERP LABEL A++ A++
EFFICIENCY ηwh 154.5% 168.7%
COP DHW
EXPANSION VALVE EEV EEV
WATER TANK CAPACITY 180L 270L
LOSSES PST BY 0.97 kWhh 1.02 kWh/24h
INNER TANK MATERIAL DUPLEX STAINLESS STEEL 2205
INNER TANK THICKNESS 1.0MM 1.0MM
INNER TANK DIAMETER Φ 500MM Φ 500MM
RATED WATER TANK PRESSURE 8 bar 8 bar
OUTER CASING RAL 9016 RAL 9016
FAN
VENTILATION VERTICAL DISCHARGE VERTICAL DISCHARGE
DUCT CONNECTIONS 150MM 150MM
RESISTIVE IMMERSION ELEMENT
RATED OUTLET WATER TEMPERATURE 55°°C 55°°C
MAX OUTLET WATER TEMPERATURE 70°C 70°C
WORKING RANGE WITH ELECTRIC
HEATER
WORKING RANGE WITHOUT
ELECTRIC HEATER
MAGNESIUM ANODE MAGNESIUM ANODE
ANTI LEGIONELLA WATER HEATED UP TO 70°C BY ELECTRIC HEATER
IP CLASS IPX1 IPX1
UNPACKED DIMENSION Φ 620×1620MM Φ 620×1850MM
PACKED DIMENSION 700×700×1790MM 700×700×2010MM
NET WEIGHT 88KG 102KG
GROSS WEIGHT 106KG 120KG
46 dB 46 dB
VI. SPECIFICATIONS

7
Exhaust Air Heat Pump with CMEV
INSTALLATION
I. CHOOSE A SUITABLE LOCATION
01. This product is suitable for an indoor utility room or plantroom.
02. Please ensure there is adequate space for installation and maintenance.
It is recommended a head height of 300mm is required.
03. The Air
with less than 0.5mtr duct length.
04. The product is to be installed in a dry and free from humidity location.
05. Su
Please refer to the technical data sheet for the products weight.
06. Please select a suitable location for the exhaust air vent to the outside.
Always insulate the exhaust air ducting to avoid condensation when operational.
07. Please select a suitable location for the supply air intake ducting from the outside if being used
on high performance air tight building. Always insulate the supply air intake ducting to avoid
condensation when operational.
08. Please ensure there is access to the front panel for maintenance.
Please note the clearance areas required for maintenance.
09. Always allow extra room for pipe connections and power cables.
10. Always refrain from installing on a surface with loose coverings as the product
may make a vibrating noise when operating.
If the product is installed in a location where there is a possibility of frost, then all precautions
NOTE
The following locations are not recommended as suitable installation locations of the product.
Areas containing toxic gases or mineral oils.
II. TRANSPORTING THE PRODUCT
01. This exhaust air heat pump is heavy and requires at least two people
to lift it with the assistance of lifting equipment.
02. It is always recommended to lift the product with all its packaging
in place.
03. Always wear PPE when lifting the product.
04. Avoid lifting at the angle greater than 75°.
All the pictures in this manual are for illustration purposes only. Please refer to local wiring and plumbing
regulations. If in doubt of anything in this manual, contact your local service agent.
NOTE

8Exhaust Air Heat Pump with CMEV
IV. PRODUCT DIMENSIONS
MODEL SIZE A SIZE B
EV-H20/180 1524 879
EV-H20/270 1943 1298
III. THE INSTALLATION OF HEAT PUMP
01. Always leave enough space for installation and maintenance. The below illustrations are guidelines only.
02. The air inlet ducting is vented from “wetrooms” like a kitchen, bathroom, ensuites and utility rooms. The minimum
size ducting is 150mm rigid or approved semi rigid ducting. Flexible ducting is not recommended and should
not be used.

9
Exhaust Air Heat Pump with CMEV
PLUMBING CONNECTIONS
II. WATER PIPE INSTALLATION INSTRUCTIONS
01.
02. Con
condensate run off.
03.
04.
05. On
possible to release the build up of pressure by slowly opening the safety relief valve. Repeat this process until the tank
06. The correct cold water intake pressure is between 1.5BAR and 6.5BAR. If the pressure is less than 1.5BAR a pressure
pump may be required for operation. Installing a pressure gauge inline with the cold water inlet will assist the user if
there are pressure issues after the installation.
07. During operation and heat pump cycle, there will be condensation droplets within the heat pump. Always ensure
the condensate pipe is connected to the drainage network.
NOTE
The safety relief valve needs to be pulled every six
months to ensure it works correctly and is not blocked.
Do not hold down the handle of the safety valve.
Do not block the drain.
If this product is installed in an outbuilding or
unheated space, please ensure all pipework including
ducting is insulated well. Failure to do so could result
infrozen pipework and condensation issues.
NOTE
WARNING
Insulate the drainage pipe to avoid freezing in cold
weather..
I. DIAGRAM

10 Exhaust Air Heat Pump with CMEV
IV. DUCTING INSTALLATION INSTRUCTIONS
Option 1 is recommended at all times. Only use
semi-rigid ducting when 150mm solid ducting is not
viable to use.
When the air intake ducting pass through the
unheated section of the building it is essential that the
ducting is wrapped in foil back insulation.
The exhaust air ducting must be wrapped in continuous
foil backed insulation and care must be taken when
the ducting leaves the building and vapour control layer.
Sample ducting layout. Shows a power open, spring
close damper on the supply air ducting. This is
possible to achieve by conecting the damper cable
from the H2O unit.
ELECTRICAL CONNECTIONS
THE ELECTRICAL CONNECTIONS MUST BE COMPLETED BY A QUALIFIED AND TRAINED PROFESSIONAL.
This product must be wired on a separate circuit protected by a 20A RCD/MCB (RCBO)
The circuit must be connected to a reliable earth electrode connected to the consumer unit.
NOTE
III . VENTILATION
SPEED VOLTAGE FREQUENCY AIR FLOW VOLUME
HIGH 230V 630 m3h
MIDDLE 230V 510 m3h
LOW 230V 210 m3h
CMEV FUNCTION.
The selection of the fan speed is determined by the size of the property and the designed ventilation rates to comply
with part F regulations. Once the selection is made it should be noted on the service log book at the back of this manual.
possible to increase the fan speeds in need of purge ventilation, this is done by selecting a higher speed on the controller.
It must be noted to reduce the speed to the design rated speed once the purge ventilation is completed. If there is no
requirement for the CMEV function the selector switch is set to OFF
Sample ducting layout.

11
Exhaust Air Heat Pump with CMEV
I. POWER SPECIFICATION
NOTE: Final connection is via a 20A isolating switch in close proximity to the heat pump.
POWER
SUPPLY PROTECTION DEVICE
EARTH LEAK
AGE
L&N
CONDUCTORS
PE
CONDUCTOR TYP
30mA
2.5MM 2.5MM 20 B
WIRING DIAGRAM OF THE INTERNAL CONTROL BOARD
METHOD OF APPLICATION
FILLING THE UNIT WITH WATER.
1. Whe
Follow the guidelines below to check the tank is full.
Open the cold water isolation valve and hot
water outlet valve.
Hot water outlet
Turn on a hot water tap or shower and wait for
shower when complete.
→
HOT WATER OUT
Never operate this unit if there is no water in the tank.
This will result in possible damge to the dry resistive.
Element.
2. Draining the system: Isolate the cold water feed at the valve. Open a hot water outlet or safety relief valve to drain
out the water. It is recommended to always install a drain off valve at the lowest connection point after the cold water
isolating valve.

12 Exhaust Air Heat Pump with CMEV
II. HOME PAGE ILLUSTRATION AND ICON MEANINGS
: Set water temperature (water temperature could be set by this icon).
: Current water temperature.
: Date and time (Real time could be set by this icon).
: Electric heater(When element is activated, icon appears; When element is deactivated, icon disappears).
: Compressor (When comp. is running, the icon appears; When comp. is not running, the icon disappears)
: 4-way valve (When defrost is activated, the icon appears; When defrost is deactivated, the icon disappears).
: Fan (When fan is running, the icon appears; When fan is not running, the icon disappears).
: Circulating pump(not for all in one heat pump) or PV mode( not for H20).
: WIFI (When WIFI is connected, the icon appears; When WIFI is disconnected, the icon disappears).
: Mode icon.
: Power ON/OFF.
: Mode select.
: Query.
: Set menu.
: Number keyboard: Input numbers by different number keys.
: Timer (When timer is activated, the icon appears; When timer is deactivated, the icon disappears).
22
33
44
55
99
CONTROLLER INSTRUCTIONS
Voltage: 220V ~ ±10%,50Hz±1Hz.
Ambient temperature: -7~+43oC.
Storage temperature: -20~+70oC.
Relative humidity: 0~95%RH.
Temperature accuracy: ±1oC.
Display the water temperature and setting tempera-
ture, and can query the coil temperature, ambient
temperature and exhaust temperature and so on.
Power cut memory function.
When power cut, the clock will still work.
Timer on/off.
Automatic defrosting.
Touch screen.
Error code display.
Anti-freezing function.
2. Main function
I. FEATURES
22
33
445599
TOUCHSCREEN CONTROL SECTION

13
Exhaust Air Heat Pump with CMEV
III. OPERATION INSTRUCTION
When the system is off, touch the button “ON/OFF”, the system will turn on.
When the system is on, touch the button “ON/OFF”, the system will turn off.
When the screen is in sleep mode, simply touch it to wake it up for operation.
No operation on the controller for 5 minutes, the screen will enter sleep mode.
Only the current water temperature will be displayed.
Heating mode: Touch the button “MODE” to select different working modes.
Also the working mode will be showed on the top right corner of screen.
Only heating mode is accessible by “MODE” button for H20. Please refer to below
for accessing other working modes.
oC, only heat pump works.
Hybrid mode: When 55ooC, heat pump heats the water to 55oC.
and stop working, then the electric heating element continues heating the water to set temperature.
Bo
mode will be activated. Under this mode, heat pump and electric heating element work simultaneously.
Timer mode: Please refer to 3.5.3 for details. All above modes could be accessible under timer mode.
Heat pump failure mode: When heat pump system fails, electric heating element will work automatically.
Low ambient temperature mode: When the ambient temperature is less than 5oC
only electric heating element is allowed to work.
3.2 Select working mode
Touch the icon on the home Page to enter water
The max water temperature the heat pump can achieve is 55oC,
It is recommended not to raise the temperature above this.
The max water temperature that electric heating element
could achieve is 70oC.
Based on above, DO NOT set water temperature over 70oC.
3.3 Set water temperature
Touch the icon on the home page to enter real-clock
the time and return to home Page.
Touch the button “SET” on the home page to enter real-clock
3.4 Real-Clock Setting

14 Exhaust Air Heat Pump with CMEV
Press the button “Setting”, enter the settings menu page.
3.5 Settings Menu
Touch the button “User Para”, enter the page of “User Para”.
The defrost could be turned on/off manually by setting the number 0/1,
adjustment is not suggested.
The electric heater could be turned on/off manually by setting
the number 0/1, adjustment is not suggested.
The sterilization could be turned on/off manually by setting the number 0/1,
and the water will be heated up to 70oC, adjustment is not suggested.
The reheat temperature could be set by F03, adjustment is not suggested.
Both heat pump and electric heater will be turned on simultaneously
by setting F13 to 0,adjustment is not suggested.
The reheat temperature could be set under F13(fast heating function),
adjustment is not suggested.
PV mode could be activated by setting “PV function” to 1 (Not for H20).
PV mode must be performed under timer mode, so must set the working
period for PV mode (Not for H20).
3.5.2 Engineering parameters
Only professional trained engineers are allowed
to get access into this setting.
3 time periods at most could be set, including “Timing1”, “Timing2” and “Timing3”.
The “time start” and “time end” could be set in each time period separately,
when “time start” is set same as “time end”, the timer will not be activated.
Once
3.5.3 Timer setting

15
Exhaust Air Heat Pump with CMEV
01. Download the “TuyaSmart” or “Smar Life” APP on
ppstore, usually “TuyaSmart” is recommended.
3.5.4 WiFi setting
02. After APP is downloaded, register your account by
03. Make sure the mobile phone to be connected with
to input the WiFi name and password. Now the
phone will search the available devices.
05. Once the connection is successful, you will see
following pages on the controller and APP.
06. See following homepage on APP.

16 Exhaust Air Heat Pump with CMEV
Touch the button adjust the brightness on the screen.
3.5.5 Screen brightness setting
Touch the button restore the factory default setting (this function has not been available yet).
Water inlet temp.(tank) means the current water temperature.
Water outlet temp.(tank) will not show any information.
Touch the button“Next” to show next page, press the button “Prev ” to show the previous page.
Circulating

17
Exhaust Air Heat Pump with CMEV
Press the button “Clear record”, the fault record will be eliminated.
IV. TROUBLE SHOOTING
NO. FAULT DESCRIPTION CAUSES
WATER FLOW SWITCH FAILURE NOT APPLICABLE
2. LOW PRESSURE PROTECTION
1. LACK OF REFRIGERANT
2. BLOCKAGE IN THE REFRIGERANT SYSTEM
3. PRESSURE SWITCH FAILURE
4. RESSURE SWITCH FAILURE
3. HIGH PRESSURE PROTECTION
1. REFRIGERANT OVER FILLING
2. BLOCKAGE OR AIR MIXED IN THE REFRIGERANT
3. PRESSURE SWITCH FAILURE
4. GAS EXHAUST TEMP PROTECTION
1. SENSOR FAILURE OR SENSOR CONNECTION WIRE FAILURE
2. LACK OF REFRIGERANT OR AIR MIXED IN THE REFRIGERANT
3. EEV OPENING ABNORMAL
5. MAIN BOARD FAILURE
5. COIL TEMP SENSOR FAULT 1. SENSOR FAILURE OR SENSOR CONNECTION WIRE FAILURE
2. MAIN BOARD FAILURE
AMBIENT TEMP SENSOR FAULT SAME AS NO.5
RETURN WATER TEMP FAULT SAME AS NO.5
EXHAUST TEMP SENSOR FAULT SAME AS NO.5
9. OUTLET WATER TEMP SENSOR FAULT SAME AS NO.5
GAS RETURN TEMP SENSOR FAULT SAME AS NO.5

18 Exhaust Air Heat Pump with CMEV
V. ELECTRIC HEATING ELEMENT CONTROL:
01. When defrosting, electric heating element is forced to be turned on; The electric heating element is not allowed to
be turned on within 60 seconds after the machine is powered on or after the electric heating element is turned off.
02. Wh
forced to continue heating to water setting temperature. (Under this condition, the electric heating element is not
restricted by the ambient temperature conditions).
03. When the Booster mode is activated, both the electric heating element and heat pump are turned on.
The Welement icon appears.
04. When
05. When high pressure protection or exhaust high temperature protection is incurred, and the compressor will be
locked when ambient low temperature protection.
06. When exhaust temperature sensor failure, coil temperature sensor failure, gas return temperature sensor failure, the
electric heating element will be automatically activated on above conditions, which is not restricted by the ambient
temperature requirement.
COMMISSIONING
PLEASE CONFIRM THE FOLLOWINGS BEFORE COMMISSIONING OF HEAT PUMP
All connections to the unit are tight and there are no leaks in the pipework
02. All ducting connections are correct and the ducting is free from blockages
03. Al
and all connections are tight. The unit is protected with the correct protection
device at the consumer unit.
04. Insulation of the ducting is complete.
05. The unit has adequate earthing as per local wiring regulations.
There is no air present in the system.
Cold water pressure is within the limits as per the manual.
Onc
to select the mode to operate the system as per the control panel manual.
09. It is recommended to allow 4-5 hours to heat the water fully when turning
the heat pump will switch off and only switch back on when the temperature
is 5 degrees below the set point target temperature.

19
Exhaust Air Heat Pump with CMEV
MAINTENANCE & SOLUTION
connected to both vents and use a vacuum cleaner to clear out any dirt or debris.
02. Check
that use water from a well.
03. Inspect and clean out the evaporator using a vacuum cleaner. The evaporator is located at the top of the unit.
Follow these steps to carry out this task.
I. MAINTENANCE
Turn off the power supply to the unit using the local isolator.
Unclip the control wire to the touchscreen control panel and remove from the casing.
Using a vacuum cleaner carefully clean out the evaporator for any dirt or debris.
ERROR REASON APPROACH
NO HOT WATER
NO POWER TO THE UNIT.
THE TEMPERATURE SETTING IS SET
VERY LOW
CONTACT THE FITTER
CONTACT YOUR SERVICE AGENT
THE SCREEN IS DARK
THE TEMPERATURE CONTROLLER
IS DAMAGED
THE CIRCUIT BOARD OF THE
INDICATOR LAMP IS DAMAGED.
THE SCREEN IS DARK
THE HOT WATER ISOLATOR VALVE
IS SHUT OFF
THE WATER PRESSURE IS TOO
LOW
CHECK THE POSITION OF
THE HOT WATER VALVE
INCREASE THE PRESSURE AND
IF REQUIRED FIT A PUMP
WATER LEAKING CONTACT THE FITTER CONTACT THE FITTER

WWW.ECOVOLT.IE
ROSEMOUNT BUSINESS PARK, DUBLIN 11, IRELAND
AFTER-SALE SERVICE
SHOULD YOU REQUIRE SERVICE ASSISTANCE WITH THE ECOVOLT H20 PLEASE LOG INTO OUR WEB-
SITE TO LOG YOUR SERVICE REQUEST. THE FOLLOWING URL WILL TAKE YOU TO THE CORRECT PAGE:
www.ecovolt.ie/service-request
SERVICE LOGBOOK
DATE COMPANY COMMENTS
This manual suits for next models
1
Table of contents
Popular Heat Pump manuals by other brands

Atlantic
Atlantic CALYPSO VM Installation

Balboa
Balboa Clim8zone User and service manual

Dimplex
Dimplex LAK 6IMR-TP Installation and operating instructions

LG
LG Hydro Kit ARNH10GK2A4 installation manual

Pentair
Pentair INTELLITEMP ITTP-5M-V Installation and operating manual

W'eau
W'eau WMIP-003 Installation & operation manual

Panasonic
Panasonic WH-SDC03H3E5 Service manual

STIEBEL ELTRON
STIEBEL ELTRON WPE-I 04 HW 230 Premium Administrator's Manual for Operation and Installation

Riello
Riello AMW 25 ST Installation and technical service instructions

Danfoss
Danfoss DHP-S&DP installation instructions

Nibe
Nibe 1127-2 Installer manual

Vaillant
Vaillant geoTHERM VWS operating manual