C
ELECTRICAL BOX
CONDUIT
7
CONTROLLER
CONTROLLER
POWER SUPPLY
DMX CABLE (BELDEN #9841)
5: Connect the red wire of the power supply to the "VDC+"
terminal of the controller.
6: Connect the black wire of the power supply to the "Ground"
terminal of the controller.
7: Run the blue and brown line voltage wires coming from
the controller power supply to the power supply case.
8: Install conduits from controller, main panel (line voltage),
and soft strip to power supply.
9: Run proper DMX cable (Belden #9841 recommended)
with three data wires from controller to the power supply
box.
5
6
5
NOTE: Refer to the "Configuring DimWheel" & "Operating
DimWheel" for help on programming the Dimwheel.
POWER SUPPLY
D
M
10: Install a red wire from the power supply to DVR-RGB-60
"VDC+" red terminal and a black wire from power supply
to DVR-RGB-60 "VDC-" blue terminal.
11: Connect one end of a data wire (blue with white stripes
wire) to controller "LEDSYNC OUT–" terminal. Connect the
other end into the DVR-RGB-60 "DMX in –" terminal.
12: Connect one end of a data wire (white with blue stripes
wire) to controller "LEDSYNC OUT+" terminal. Connect the
other end into the DVR-RGB-60 "DMX in +" terminal.
13: Connect one end of a data wire (bare shield wire) to
controller "LEDSYNC SHIELD" terminal. Connect the other
end into the DVR-RGB-60 "DMX in shield" terminal.
10
EXT in-
EXT in+
VDC-
VDC+
DMX in +
DMX in -
DMX in
shield
LEDSync
out +
LEDSync
out-
LEDSync
out shield
12
CONTROLLER
DVR-RGB-60
POWER SUPPLY
12 DO NOT
USE
NOTE: For assistance wiring a fixture to LED Driver reference
fixture installation instructions.
M
Ext in-
Ext in+
DMX in +
DMX in -
DMX in shield
LedSync thru+
LedSync thru-
LedSync shield
Driver
VDC+
VDC-
MASTER LED
DRIVER
NOTE: "DMX in+", "DMX in-", "EXT in+" & "EXT in-", controller
terminals are not used on controller.
12
11
11
13
13
10
9
2