EdilKamin PHOENIX 1115620 User manual

REMOTE CONTROL
PHOENIX
1115620
Please refer to web site, technical area

2
ENGLISH
Characteristics:
Frequency 2.4 GHz - Power supply 2 AA slimline 1.5 VDC batteries.
Dimensions 66x29x144mm; weight 105 without batteries. 2” LCD Display.
Must be kept within a temperature range of -5°C to 50°C.
USER INSTRUCTIONS: REMOTE CONTROL
USER
Risk of explosion if the batteries are replaced with other batteries of an incorrect type.
The remote control has a probe which reads the temperature and communicates with the product for automatic
management.
Day, Date and Time
DECREASE
INCREASE
ON-OFF
switch-on/switch-off
AUTO/MAN
MENU
RELAX
Room temperature
Operating procedure
(e.g. Manual P5)
or set temperature
Pellet reserve
Output power
Ventilation
- Lock/ Unlock keys
By pressing and for 2” at the same time (prolonged press) the keyboard is locked.
If you press any key, the padlock symbol appears on the main display.

3
ENGLISH
USER INSTRUCTIONS: REMOTE CONTROL
- Energy saving
After 20 seconds of non-use the backlighting switches off and after a further 10 seconds or so the display
switches off completely.
USER
DAY AND TIME
WARNING Symbols
MODE:
Auto or Timer
INFO Bar SET or ALARM or
OFF
FLAME and FAN
Symbols
ROOM
TEMPERATURE
- ON-OFF
- INCREASE
- DECREASE
- CONFIRM OK
- MENU - AUTO/MAN (prolonged press) – SCROLLING L
- RETURN - RELAX (prolonged press) – SCROLLING R
Speed 1 Speed 2 Speed 3
Speed 4 Speed 5 AUTOMATIC Speed
Relax Function active

4
ENGLISH
FOR THE TECHNICIAN
INSTALLER
Installation in the place of Asola
To install the Remote control update:
- the Firmware on the basic circuit board with a
version from PELE1711 onwards
- complete APF, if the installed revision is below rev 103.
In order to do that, copy the updated APF of the
product in the USB pen-drive supplied with the
Remote control (and containing the firmware).
Insert the USB pen-drive into the product’s USB
socket and supply power to the product. After
about 30 seconds, a beep will signal that the
reprogramming has completed successfully.
At this point the Phoenix must be linked with the
product.
The remote control will show this display.
To link the Remote control with the product, disconnect
and restore power to the basic circuit board.
When you hear the beep, press the key on the remote
control . This display will appear:
When the Remote control finds a compatible
communication, the linking procedure will terminate
automatically.
If the remote control does not find any compatible
communication, it will again display “No network”.

5
ENGLISH
FOR THE TECHNICIAN
INSTALLER
Disassociating the remote control from a
circuit board - LEAVE
If the remote control has already been linked to
one circuit board and must be linked to a different
circuit board (for example if a circuit board has been
replaced), the “No network” icon will appear on the
display.
To link the remote control to the new basic circuit board,
you need to perform the disassociation procedure.
The procedure can be performed via the Technical
Menu or, if there is no communication, in the following
manner:
press the “Return” key for at least 10 seconds.
The following display will appear
and the disassociation can be confirmed with the
key
The remote control will display “No network” and it is
then possible to proceed with a new linking.
If no buttons are pressed, the Remote control will go to
“Energy Saving” while waiting for confirmation.
Once the Phoenix has been linked to the product, the
remote control proposes the update of the APF, which
requires confirmation.

6
ENGLISH
OPERATION
Mode Settable parameters
MANUAL • power level
• ventilation level (if there are
two or more fans, they can be
adjusted separately)*
AUTOMATIC • desired room temperature
• ventilation level *
CRONO • desired room temperature,
selected per day of the week
• ventilation level*
* when lowering the ventilation, the product can also
automatically modulate its power to maintain maximum
efficiency.
USER INSTRUCTIONS
USER
The product also has the following supplementary
functions.
Function Modes in which
it can be acti-
vated
What it does
Stand-By automatic crono when the desired
temperature is
reached, the
product switches
off and then back
on again when the
temperature drops
RELAX manual
automatic crono
enables natural
convection mode
(fan off), thus
reducing the power
EASY
TIMER
manual
automatic
is used to
programme the
switching off/on
after a set number
of hours (maximum
12 hours)
OPTIONAL CONNECTIONS
The technician can supply, on request:
• external thermostat;
• telephone dialler;
• probes/thermostats for managing the ducting fans
(if present on the purchased model).
1) Ex.: air product in Automatic with 3 fans in AUTO, Power P5, Set Room 18.5°C
2) Ex.: air product in Manual with 3 fans in V3, Power P3.
3) Ex.: air product with Crono active and Fans in V5, Power P5, Set Room = 22°C.
1) 2) 3)

7
ENGLISH
USER INSTRUCTIONS
USER
POWER ON/POWER OFF
These operations will take a few minutes, during which the flame must appear or extinguish. Simply wait without
taking any action.
During switch-off,
the display shows the text “OFF”.
- CLEAN in the cleaning phase
- START in the Load Pellets and Start 1 phases
- START in the Start 2 phase with the flame symbol
- WARM UP in the Warm Up phase with the flame symbol
If timer scheduling is active:
The switching on and off of the product can be forced with the Crono active, by prolonged pressing of the
button.
The switching on and off force the move from Crono to Automatic mode with the pre-set Set Room and Ventilation.
During switch-on:

8
ENGLISH
In AUTOMATIC mode:
Setting the Room Temperature (read by the remote control, which should be located in the room where the
product is installed). Modify the desired temperature using the “+” and “–” buttons.
AUTOMATIC MANUAL
Press any button and the display will activate, then press the button
With CRONO active, it is not possible on the main display to change the choice of Temperature level (T1, T2 or T3) or
the value of T1, T2 or T3. To do so, you need to access the Menu.
The or buttons are disabled.
The flashing “SET” or “MAN” symbol appears; the operating Mode symbols and the Power level and Ventilation
symbols disappear.
The Set is modified with the or buttons and the setting is confirmed with the button or by waiting
5 seconds without pressing any buttons.
USER INSTRUCTIONS
USER
USER CONTROLS ON REMOTE CONTROL
ON/OFF
Hold the ON/OFF button down to switch the product ON.
AUTOMATIC and MANUAL setting
Press the AUTO/MAN button for a few seconds to switch from manual to automatic mode or vice versa.
NOTE
or WAIT

9
ENGLISH
If the product is in AUTOMATIC mode and the room temperature probes in the ducted zones are
present and activated, you can press the button to confirm the main Set Room setting and enter the
setting of the Set Room for the ducted zones 2 and 3 by displaying the Room Temperature of the ducted zone and
the related Set
The flashing “SET”or “MAN” symbol appears; the operating Mode symbols and the Power level and Ventilation
symbols disappear.
The Set is modified with the or buttons and the setting is confirmed with the button or by waiting
5 seconds without pressing any buttons.
USER INSTRUCTIONS
USER
Press any button and the display will activate, then press the button
- FAN ADJUSTMENT
Fan ventilation adjustment can be accessed from the Menu. See the relevant section
In MANUAL mode:
Setting of the power
Modify the power level (displayed by the flame symbol) using the “+” and “–” buttons.
WAIT
WAIT
or WAIT

10
ENGLISH
USER INSTRUCTIONS
- RELAX FUNCTION
Natural convection function (without ventilation) with automatic power limiting.
This function is available in all modes: automatic, manual and crono.
Press the button for two seconds to activate the Relax function.
Activation is indicated on the display with the RELAX symbol instead of the frontal fan.
Again by prolonged pressing of the button, the function is disabled.
The product reduces its power output and after a few minutes switches the fan off too.
USER

11
ENGLISH
USER INSTRUCTIONS
AM Menu
Press the “AM” button to access the menu.
The Menu items appear with the first item already
selected.
USER
When the AM list displays, the buttons have the
following functions:
Active buttons:
go back to main display
go back one level
scroll down the AM Menu items
select the AM Menu items
- CRONO
- FAN
- STAND BY (visible only if the product is in “automatic” mode)
- NIGHT
- LOAD PLTS
- STATUS
- PLT RECIPE
AM Menu 2:
- DATE-TIME
- LANGUAGE
- BUZZER
- ALARM LOG
- DATA
- SOFTWARE
- TECHNICAL MENU
and

12
ENGLISH
- Crono
When the Crono function is active, the user sets a
temperature setpoint and a time period for which that
setpoint is specified.
The setting involves different steps, which do not need
to be consecutive:
• enabling the Crono mode to 7 days a week or on
single days (“ENABLE” on the display);
• setting three temperature setpoints, making sure
that T1 is always lower than T2 and T2 lower than
T3 (“TEMP” on the display);
• linking of one of the three temperatures (T1, T2 or
T3) with a time period (DISPLAY/CHANGE).
To access the Crono setting function, you must enter
the Menu with the button
An the first item is CRONO
You confirm the choice with the button and view
the options
The item “crono” is displayed on the navigation bar
USER INSTRUCTIONS: CRONO
USER
- Enable
With “Enable” you can activate or disable Crono
If you confirm the “Enable” item with the button
this display appears
or this display
With the and buttons, you can move from
“OFF” to “ON” and vice versa.
You can confirm the choice with the button or
the button and go back to the previous display.

13
ENGLISH
USER INSTRUCTIONS: CRONO
USER
- T1 – T2 and T3
T1, T2 or T3 are used to set the temperatures linked to
the levels. Normally:
T1 = Night Level (~16°C)
T2 = Day Level (~20°C)
T3 = Comfort Level (~22°C)
You choose T1, T2 or T3 with (going up the
Menu) and (going down the Menu) and confirm
the item with the button
The or buttons are used to set the value
with moves of 0.5.
You confirm the choice and go back to the previous
display using the button or the button.

14
ENGLISH
USER INSTRUCTIONS: CRONO
USER
- Display/Change the settings
“Display/Change” is used to display and to change the current
scheduling.
You confirm the choice with the button and view the
scheduling for Monday and the cursor is positioned on the symbol
“Set”
The button is used to move the cursor between the “Set”
symbol and the Day of the Week
The button is used to go back to the previous display.
If the cursor indicates the symbol “Set” the and
buttons are used to choose an action
The button is used to confirm the selected action.
If the cursor indicates the day of the week, the and buttons are used to choose the day and to display the
related scheduling

15
ENGLISH
USER INSTRUCTIONS: CRONO
USER
- to Set
By pressing the button, you choose “SET”
whether the cursor is on the Action or the day of the
week; the scheduling of the first 12 hours of the
selected day is displayed.
In the top left area the reference of the day is displayed
and in the top right the starting time of the time period
(00:00), with the cursor below the graphic bar.
The current Set between OFF and the values of T1, T2
and T3 are displayed bottom centre.
The or buttons are used to change the temperature levels between OFF and T1, T2 and T3
The and buttons are used to move the time period forwards or backwards.
The button is used to confirm.
If the movement is made by holding down the or button
The previous level is copied with a frequency of 1/2h per second.

16
ENGLISH
USER INSTRUCTIONS: CRONO
USER
- to Delete
If the “Delete” action is chosen and confirmed with the button,
the scheduling is reset.

17
ENGLISH
USER INSTRUCTIONS: CRONO
USER
- to copy/paste
If the “Copy” action is chosen and confirmed with the button
The day of the week is highlighted and the cursor appears.
Using the and buttons the day is chosen on which the scheduling is to be pasted.
The button is used to confirm the copy action. The day on which the action was performed is highlighted and the
action can be repeated.
The button is used to go back to the previous display.
The button is used to move to the chosen action.
The button is used to go back to the previous
display
The button is used to go back to the choice
of action

18
ENGLISH
USER INSTRUCTIONS: VENTILATION
USER
- for the ventilation

19
ENGLISH
USER INSTRUCTIONS: STAND BY
USER
- Stand by
When the Stand by function is active, in automatic
and crono mode, the product shuts off when the
temperature setpoint is reached and turns on again
when the room temperature drops.
When the Stand By function is not active, the product
sets itself to minimum power when the temperature
setpoint is reached.
NOTE visible only if the product is in “automatic” mode.
The product is programmed by default with a delta of +/- 1°C to optimise comfort.
The technician can change this setting during commissioning to suit the needs of the application.
The display shows the temperature rounded down. This means that 20.1°C and 20.9°C are indicated as
“20°”.
For example, with the room temperature set to 20°C, the product will enter the modulation mode/switch off
when a temperature of 21 C is reached and will switch on again below 19 C.

20
ENGLISH
USER INSTRUCTIONS: NIGHT
USER
Night (deferred switching on/off)
The function is available only if Crono is not active.
This function switches the product on/off after a set
period from activation of the function.
This is convenient if you go to bed and want the product
to switch on/off after a few hours (12 hours maximum).
The switch ON time is shown on the main display.
The switch OFF time is shown on the main display.