HOUSES NEED BREATH HOUSES NEED BREATH
Fresh air intelligent controller is designed for monitoring real-time
indoor temperature, humidity, and VOC concentration. Built-in gas
sensor has high sensitivity not only to VOC such as; ammonia,
formaldehyde, benzene, xylems, hydrogen, alcohol, carbon monoxide,
methane, propane, alkyl, styrene, propylene glycol, phenol and other
volatile organic compound. Also, to other air contaminants such as
wood, paper, cigarette smoke and a dozen combustion gases.The
output signal of fresh air controller can control the startup and speed
of ventilator directly. Can effectively improve indoor air quality;
create a healthy, comfortable, energy-efficient living and working
environment
Display
1. Humidity display
2. VOC concentration display
3. Standby time under time function
4. Temperature display
5. Working status display
6. Fan speed status
7. Working time under timer function
Pacific Heating & Cooling Technology Ltd.
9/28 Torrens Road Burswood, Auckland 2013
www.pacifichac.nz
Ph: 09-2652626 Fax: 09-2652525
Fresh Air Intelligent Controller
PV-800E
Good Indoor Air Quality Means
HOUSES NEED BREATH HOUSES NEED BREATH
Operation
MANUAL: The fan can be set at stop, low speed, medium speed, and high
speed by buttons and , then the fan will run according to the setting,
won’t be affected by temperature, humidity, VOC concentration and timer.
AUTO: under this mode, when VOC concentration exceeds its set value,
controller will increase the fan speed automatically. VOC concentration set
value should be set by button when enter parameter setting, VOC
concentration is recommended setting between 7.0 –10.0 ppm. Under
auto mode, VOC concentration can be set by and , when VOC
concentration doesn’t exceed its set value (air is fresh), fan is at stop or
low speed. And under auto mode, controller can also control fan speed by
indoor temperature and humidity setting, when temperature or humidity
exceeds its set value, controller will also increase fan speed automatically.
1. TIMER: The fan will run and stop according to the set time, making the
fan run at low speed, medium speed or high speed need to press and
;Start running time of fan (ON-TIMER), stop running time of fan (OFF-
TIMER).
2.OFF status:No LCD display,the fan stop.
3.Parameter setting: Press to start parameter setting of VOC
concentration、ON-TIMER 、OFF-TIMER 、TEMPERATURE & HUMIDITY.
When entering the appropriate setting items, the corresponding value will
flick, adjust the value by and . Controller will return to normal
working condition and save setting parameter automatically if you won’t
press any buttons more than 5 seconds.
Specification
Dimension: 86×86×40mm
Warm-up time: 2 minutes (initial power warm up for 72 hours)
Fixing whole distance: 60mm (standard)
Response time: ≤10 seconds
Wiring terminal: Max 2.5 mm2wire
Recovery time: ≤30 seconds
Rated voltage: AC110V - - 230V, 50/60Hz
Operating temperature: -10℃--- +50℃
Standby Power: ≤1w.
Operating humidity: 5%RH——90%RH
Control power: ≤200W
Storage temperature: -10℃- +60℃
Output interface: Three speed
Storage humidity: ≤60%RH
Temperature display range: 0℃—50℃
Life: ≥10 years
Humidity display range: 25%RH—90%RH
VOC display range: 0.3ppm—25.0ppm
Wiring & Installation diagram

Popular Controllers manuals by other brands

Burkert 8745 MFM Ethernet operating instructions

Burkert

Burkert 8745 MFM Ethernet operating instructions

MEDENUS RS 250 Operating and maintenance instructions

MEDENUS

MEDENUS RS 250 Operating and maintenance instructions

Delta Electronics Temperature Controller DTE instruction sheet

Delta Electronics

Delta Electronics Temperature Controller DTE instruction sheet

CoCo AWS-3500 Quick installation guide

CoCo

CoCo AWS-3500 Quick installation guide

Norac UC4+ Raptor Pro 1200 installation manual

Norac

Norac UC4+ Raptor Pro 1200 installation manual

Emerson Bettis XTE3000 Installation, operation and maintenance manual

Emerson

Emerson Bettis XTE3000 Installation, operation and maintenance manual

MBNLED WS2812 user manual

MBNLED

MBNLED WS2812 user manual

Serafim S1 user manual

Serafim

Serafim S1 user manual

TEUCER LR-4RGBCCT quick start guide

TEUCER

TEUCER LR-4RGBCCT quick start guide

AUTLED LC-012-014 user manual

AUTLED

AUTLED LC-012-014 user manual

YOKOGAWA UP150 instruction manual

YOKOGAWA

YOKOGAWA UP150 instruction manual

PI C-863 user manual

PI

PI C-863 user manual

Master WiSlide 500 KG User and installation manual

Master

Master WiSlide 500 KG User and installation manual

Unitronics Vision OPLC V130-33-T38 installation guide

Unitronics

Unitronics Vision OPLC V130-33-T38 installation guide

Efapel 21311 manual

Efapel

Efapel 21311 manual

Chemtrol PC6000 instruction manual

Chemtrol

Chemtrol PC6000 instruction manual

Intermatic InTouch CA5100 manual

Intermatic

Intermatic InTouch CA5100 manual

Aerosoft Rail Driver's Cab Controller manual

Aerosoft

Aerosoft Rail Driver's Cab Controller manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.