Ekinex EK-SN2-TP User manual

1
KNX standard wall presence detector
with movement function
Code: EK-SN2-TP
Datasheet STEKSN2TP_EN
Device for motion/presence detection with PIR sensors
(passive infrared) in a semicircular area. The ideal use
is in corridors, transit areas, services, stairwells, envi-
ronments with occasional occupancy. It has dedicated
channels for controlling lighting, HVAC equipment and
alarms. It also allows the measurement of brightness in
the environment. It has an integrated KNX bus commu-
nication module and is designed for installation in a wall-
mounting box; it is powered by the KNX bus and does not
require an auxiliary power supply.
• Evolved lens model, with well-distributed and concen-
trated detection capabilities: the detection beams pro-
vide high intensity and sensitivity, to detect even small
shaking movements
• Adjustable sensitivity via ETS on 4 levels
• Possibility of Master / Slave conguration (via ETS)
• Operating modes: Manual ON / AUTO / OFF
• Use in the KNX TP bus system (twisted pair) in combi-
nation with other KNX devices
• Function parameters and settings via ETS 5.0 (Engine-
ering Tool Software) or higher
Technical data
• Rated voltage: 24 Vdc (21 - 30 Vdc) supplied by KNX
bus
• Current consumption (on KNX bus): max 10 mA (opera-
tion) / 5 mA (Standby)
• Connection type: KNX bus with Ø 0.8 mm, single cable
• Outputs: 5 channels (2 for lighting, 2 for HVAC, 1 for
alarm)
• Mounting height: 1.2 - 2.0 m
• Detection angle: up to 200 °
• Detection range: up to 9 m if mounted at a height betwe-
en 1.2 - 1.5 m, up to 8 m at a height between 1.8 - 2.0 m
• Light measurement range: 10 ... 2000 Lux
• Housing, lens and frame in plastic material
• Safety standards: IEC 61000-6-1 / IEC 61000-6-3 / EN
55014 / EN 50491
Environmental conditions
• Operating temperature: - 20 ... + 40°C
• Relative humidity: 95% not condensing
REFLSN2TPD
TP S
Description
The ekinex® sensor EK-SN2-TP is a KNX standard pre-
sence detector, wall switch type, which uses passive in-
frared (PIR) motion detection technology to automatically
switch on or o the connected lighting or HVAC devices,
when the monitored space is occupied or free according
to the detector settings. Simple installation and quick
setup allow you to replace or complement existing wall
switches. It is designed for use in interiors such as shops,
oces, small rooms, living spaces such as corridors, stai-
rs, bedrooms, etc.
Main functional characteristics
• Hidden switch, can t single round or square wall ush-
mounting box
• Simple and safe plug-in installation
• The presence detector is used to control devices, e.g.
lighting and HVAC
• Learning function, to congure the device functions by
reading the “ambient Lux” parameter
Other characteristics
• Housing, lens and frame in plastic material
• Wall installation in ush mounting box
• Protection degree IP20 (installed device)
• Climatic classication 3K5 and mechanical 3M2 (accor-
ding to EN 50491-2)
• Pollution degree 2 (according to IEC 60664-1)
• Weight 40 g (70 g with mounting support)
• Dimensions 80 x 80 x 31 mm
Versions
Code Colour Application program
(## = version)
EK-SN2-TP-GAA white
APEKSN2TP##.knxprod
EK-SN2-TP-GAE black
Delivery and accessories
The xing screws and the terminal for connecting to the
KNX bus are included in the supply of the device. This
must be completed with a plastic adapter, a plate and
eventually a frame (all have to be ordered separately).
Finishing plate
The sensor is completed with an ekinex®plate in metal or
Fenix NTM®material. The plate must have (at least) a 50
x 50 mm window in combination with a plastic adapter for
‘NF, Deep or Surface series mounting.

2
Operation
The sensor reacts to the thermal radiation emitted by mo-
ving bodies. A person walking in the detection area across
the sections triggers the sensor.
The measurement of the room brightness is carried out by
an integrated light sensor; the brightness value, measu-
red in Lux, can be transmitted on the bus.
The internal brightness sensor can also be used to main-
tain a constant ambient brightness if a dimmable light
source is available.
Frame
The device is completed with a square ekinex®frame of
the form or ank series in metal or Fenix NTM®material.
The ‘NF (No Frame) versions, on the other hand, must be
mounted without a frame.
‘NF, Surface oe Deep Series square plate
with 50 x 50 mm window
Code EK-PQN-...(*) (‘NF)
Code EK-SQN-...(*) (Surface)
Code EK-DQS-...(*) (Deep)
Switching, display and detection elements
The device is equipped with 2 switching elements, loca-
ted under the cover:
• a KNX programming button (1)
• a switch to select the operating mode Manual / ON /
OFF (2)
The following signaling and detection elements are also
visible through the lens:
• a blue programming LED (3),
• a red signaling LED (3),
• a PIR sensor, a light sensor and an IR receiver
(*) To be completed with the extension for colour and nishing
Form
square
frame
EK-FOQ-...(*)
Flank
square
frame
EK-FLQ-...(*)
1
3
2
1) Programming mode button
2) Switch for selecting the operating mode
3) Signalling and programming LED
The lighting channels have two operation modes, Auto-
matic or Semi-automatic:
• the automatic mode controls both switch-on and switch-
o, when a movement is detected;
• the semi-automatic mode requires manual switch-on,
which is maintained until movement is detected; it will
swich-o only when no more movement is detected.
In automatic mode, a load connected to a lighting channel
will be switched on when movement is detected and (if
desired) the ambient light level is below a preset bright-
ness value.
When no movement has been detected for a program-
mable time duration, a stand-by phase can be entered,
during which the light can be dimmed to a lower intensity.
The HVAC channels act in a similar way as the Light Con-
trol channels, but with neither the standby time nor the
dependence from the light level.
Positioning
The actual detection range of the sensors depends on the
mounting height. It is recommended to install the device
at a height of 1.2 m - 2.0 m. The detection range is 9 m
at a height of 1.2 m - 1.5 m and up to 8 m at a height of
1.8 m - 2.0 m.
Installation at a height of 1.2 - 1.5 m
3m
0 0.5 1 3 9m
1.2 - 1.5m
3.5m
0 0.8 1.5 4 8m
1.8 - 2.0m
98703 9
m
311 8
7
200O
048
m
841.5 1 . 57 6 67
200
O
Third
detection
zone
Second
detection
zone
First
detection
zone
Side view
Warning! The electrical connection of the devi-
ce can be carried out only by qualied person-
nel. The incorrect installation may result in elec-
tric shock or re. Before making the electrical
connections, make sure the power supply has
been turned o.
!
Top view
3m
0 0.5 1 3 9m
1.2 - 1.5m
3.5m
0 0.8 1.5 4 8m
1.8 - 2.0m
98703 9
m
311 8
7
200O
048
m
841.5 1 . 57 6 67
200
O

3
Mounting
The device has an IP20 degree of protection and is the-
refore suitable for use in dry indoor environments. The
device can be assembled on a round or square box.
To assemble the device, carry out the following opera-
tions:
• insert the plastic adapter (c) on the device (d);
• insert the bus terminal, previously connected to the bus
cable (see: “Connecting to the KNX bus network”), in
the appropriate seat on the back of the sensor;
• x the adapter-device assembly (c+d) by means of the
pair of screws (e) on the ush-mount wall box (a) with
suitable holes, possibly inserting (if applicable) the fra-
me (b) between the box and the adapter;
• snap-t the plate (f).
The optimal range is achieved walking through several
portions of the detection area.
Since the detector responds to temperature change, be
aware that the following conditions may cause lower sen-
sitivity:
• In very foggy days, the sensitivity may be less due to
moisture collecting on the lens.
• In very hot days, the sensitivity may be less since high
ambient temperature is close to body temperature.
• In very cold days when heavy clothing is worn, espe-
cially if the facial area is covered, very little heat will
be emitted from the body causing the unit to be less
sensitive.
Please also verify following conditions during installation:
• Avoid pointing the detector toward objects with highly
reective surfaces, such as mirrors, glass, etc.
• Avoid mounting the detector very close to heat sources,
such as heating vents, air conditioners, lights, etc.
• Avoid pointing the detector toward objects which may
sway in air currents, such as curtains, tall plants, etc.
The direction of movement aects the sensitivity of the
detection.
Installation at a height of 1.8 - 2.0 m
3m
0 0.5 1 3 9m
1.2 - 1.5m
3.5m
0 0.8 1.5 4 8m
1.8 - 2.0m
98703 9
m
311 8
7
200O
048m841.5 1 . 57 6 67
200
O
Third
detection
zone
Second
detection
zone
First
detection
zone
Side view
Greater
sensitivity if
movement
crosses the
lens beam
Less sensiti-
vity if move-
ment occurs
towards the
lens
a) Wall mounting box (not provided by ekinex)
b) Frame (eventual) for Form o Flank Series (to be ordered separa-
tely)
c) Plastic adapter (to be ordered separately)
d) EK-SN2-TP-... sensor
e) Fixing screws (for metal support)
f) Square plate of ‘NF, Surface o Deep series (to be ordered separa-
tely) with 50 x 50 mm window
ab c
d
e
f
Installation for round and square ush mounting box
Top view
3m
0 0.5 1 3 9m
1.2 - 1.5m
3.5m
0 0.8 1.5 4 8m
1.8 - 2.0m
98703 9
m
311 8
7
200O
048m841.5 1 . 57 6 67
200
O

4
Limitazione of the detection area
The detection area can be limited, in order to avoid
unwanted activations, by means of the supplied optical
shielding lters. The shield consists of three layers, each
divided into four units, capable of masking an angle of
approx. 50 ° each.
When mounting the device at a height of 1.2 m - 1.5 m,
the detection range is:
• Layer A: masks the area with a circle from about 0m
to 9m.
• Layer B: masks the area with a circle from about 0m
to 3m.
• Layer C: masks the area with a circle from about 0m
to 1m.
Cut the screen for the lens provided, to remove the sec-
tors related to the desired detection area.
A
B
C
a b c d
Layer A eliminated Layer B eliminated Layer C eliminated
98
7
03 9
311 8
7
200
O
98
7
03 9
311 8
7
200
O
98
7
03 9
311 8
7
200
O
A
B
C
ad
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
A
ab c d
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
98
7
03 9
311 8
7
200O
98
7
03 9
311 8
7
200O
98
7
03 9
311 8
7
200O
A
B
C
ad
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
A
ab c d
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
Detection pattern
Unit: meter
98
7
03 9
311 8
7
200O
98
7
03 9
311 8
7
200O
98
7
03 9
311 8
7
200O
A
B
C
ad
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
A
ab c d
d (50
O
)
c (50
O
)
b (50
O
)
a (50
O
)
200O
3 31 1 0
98
7
9
8
7
Detection pattern
Unit: meter
Apply the screen by inserting the edge between the lens
and the external ring, in the central and lateral grooves.
To remove the screen, press slightly with a screwdriver in
the central groove and remove it carefully.
Connection of the KNX bus line
The connection of the KNX bus line is made with the ter-
minal block included in delivery and inserted into the slot
of the housing.
Bus
KNX
The connection procedure is as follows:
• strip the KNX bus cables with the appropriate tool (not
included in the supply), exposing about 5-6 mm);
• nish the end with the clamp
• connect the device to the bus cable terminated by the
standard terminal block on the back of the device.
At this point it is recommended to carry out the commis-
sioning of the device (see “Commissioning”), or at least
the download of the physical address, using the program-
ming button placed close to the bus connector.
Please check the user manual for further details on instal-
lation and commissioning.
Warning! In order to supply the KNX bus lines use
only KNX bus power supplies (e.g. ekinex EK-AB1-
TP, EK-AG1-TP or EK-AM1-TP). The use of other
power supplies can compromise the communica-
tion and damage the devices connected to the bus.
!

5
Note. The conguration and commissioning of KNX
devices require specialized skills. To acquire these
skills, you should attend the workshops at KNX cer-
tied training centers.
i
For the commissioning of the device the following activi-
ties are required:
• make the electrical connections as described above;
• turn on the bus power supply;
• switch the device operation to the programming mode
by pressing the programming pushbutton; the blue pro-
gramming LED (visible through the device lens) turns
ON;
• download into the device the physical address and the
conguration with the ETS®program.
Dimensions [mm]
At the end of the download the operation of the device au-
tomatically returns to normal mode; during the program-
ming process, the programming LED is turned o. Now
the device is programmed and ready for use.
Conguration and commissioning
Conguration and commissioning of the device require
the use of the ETS®(Engineering Tool Software) program
V4 or later releases. These activities must be carried out
according to the design of the building automation sy-
stem done by a qualied planner. For the conguration
of the device parameters the corresponding application
program or the whole ekinex®product database must be
loaded in the ETS program. For detailed information on
conguration options, refer to the application manual of
the device available on the website www.ekinex.com.
Important: After a download, it takes approxima-
tely 60 s for the sensor to stabilize before it enters
normal operation mode. During this settling period,
the sensor may not appear to react or perform its
programmed functions.
i
Warning! Do not mount on conductive surfa-
ce. Do not open the enclosure frequently. The
sensor is a low voltage circuit; never connect it
with the 230V line network. Do not run the KNX
wiring in the same conduit used by line network
wiring.
!
Access to the slide switch
Using a screwdriver in the center groove (1), slightly pull
out the detector top cover (2). Rotate it up to access the
switch (3), then rotate it down and x it in its original posi-
tion once the setting is complete.
Reset of the device
The device can be reset from ETS®, with the following
procedure:
• select the “Unload” - “Unload application and address”
option from the ETS®header;
• press the programming button on the device.
1 2 3
Slide switch commands
• AUTO: by placing the switch in the central position, the
detector is in AUTO mode.
• ON: In ON mode, the load remains ON for 8 hours and
the LED ashes for 1 second every 5 seconds. After
8 hours, the detector automatically returns to AUTO
mode.
• OFF: in the OFF position, the load remains OFF for 8
hours and the LED ashes for 1 second every 5 secon-
ds. After 8 hours, the detector automatically returns to
AUTO mode.
In the event of a power failure, the detector enters AUTO
mode once the power is supplied again, even the switch
is set to ON or OFF.
At the end of the operation the device is reset and brought
back to the factory conditions.
Warning! The reset restores the device back to the
state of delivery from the factory. The address and
the value of the parameters set during conguration
will be lost.
!

6
Marks
• KNX
• CE: the device complies with the Electromagnetic
Compatibility Directive (2014/30/EU) and the RoHS III
Directive ((2011/65/EU).
File name Device release Updated
STEKSN2TP_EN.pdf A1.0 11 / 2022
Maintenance
The device is maintenance-free. To clean it, use only a
dry cloth; absolutely avoid the use of detergents, solvents
or other aggressive substances, particularly on the lens.
Disposal
At the end of its useful life the product
described in this datasheet is classied
as waste from electronic equipment in
accordance with the European Direc-
tive 2012/19/EU (WEEE recast), and
cannot be disposed together with the
municipal undierentiated solid waste.
Documents
This technical datasheet refers to the A1.0 release of the
ekinex® EK-SN2-TP-... devices and is available for down-
load on the website www.ekinex.com in PDF format (Por-
table Data Format).
Warnings
• Installation, electrical connection, conguration and
commissioning of the device can only be carried out by
qualied personnel in compliance with the applicable
technical standards and laws of the respective countri-
es
• Opening the housing of the device causes the imme-
diate end of the warranty period
• In case of tampering, the compliance with the essential
requirements of the applicable directives, for which the
device has been certied, is no longer guaranteed
• ekinex®KNX defective devices must be returned to the
manufacturer at the following address: EKINEX S.p.A.
Via Novara 37, I-28010 Vaprio d’Agogna (NO) Italy
Other information
• This datasheet is aimed at installers, system integra-
tors and planners
• For further information on the product, please contact
the ekinex®technical support at the e-mail address:
com
• Each ekinex®device has a unique serial number on
the label. The serial number can be used by installers
or system integrators for documentation purposes and
has to be added in each communication addressed to
the EKINEX technical support in case of malfunctioning
of the device
• KNX®and ETS®are registered trademarks of KNX As-
sociation cvba, Brussels
© EKINEX S.p.A. The company reserves the right to make changes to this
documentation without notice.

7
Annex 1. Installation
The ekinex® EK-SN2-TP-... motion/presence detection
sensor contains a KNX communication module inside. It
is suitable for installation on a wall ush-mounting box,
round (m) or square (n), equipped with xing holes with
60 mm center distance. Each device is supplied with
mounting screws and a connection terminal to the KNX
bus line.
Description Code
a) Movement sensor with metallic support EK-SN2-TP-GA_
b) Cover with lens
c) Square plate Surface version* EK-SQN-...
d) Square plate* EK-PQN-...
e) Square plate Deep version* EK-DQN-...
f) Adapter for Surface square plate EK-TAS-Q-1
Description Code
g) Adapter for square plate EK-TAQE-1
h) Adapter for ‘NF and Deep square plate EK-TAQE-1-NF
i) Square frame of Flank version EK-FLQ-...
l) Square frame of Form version EK-FOQ-...
m) Round ush-mounting box not delivered by
ekinex®
n) Square ush-mounting box not delivered by
ekinex®
*) 50 x 50 mm window
Legend
n
l
i
b
a
d
g
f
h
c
e
m
The button must be completed with a plastic material
adapter (f, g, h), a possible frame for the form (l) or ank
(i) series and a square plate with a 50x50 mm window.
The plate can be from the 71 series or from a junction
point equipped with civil series components normally on
the market (d), or from the Surface (c) or Deep (e) series.
The square plates are also available in plastic, aluminum
or Fenix NTM® and in numerous color and nish variants.
Table of contents
Other Ekinex Security Sensor manuals
Popular Security Sensor manuals by other brands

Resolution Products
Resolution Products Mighty Mouse RE111 instructions

Hytronik
Hytronik HMW15 Installation and instruction manual

NorthStar
NorthStar NP2 quick start guide

Det-Tronics
Det-Tronics X3300 instructions

Theben
Theben Timeguard PDSM361AB Installation & operating instructions

Honeywell
Honeywell Miller Revolution Harness manual