MOUNTING
9. Place reed at desired location
(top, right, bottom or left)
10. Position base. Mark and drill four (4) holes 1”
(25mm) deep. Using plastic anchor, drill 3/16”
(4.5mm). Install into wood or steel: drill 9/64”
(3.5mm). Mount using (4) M4 x 25mm screws.
11. Install reed magnet, mark with pencil,
drill, install using plastic anchor, drill
3/16” (4.5mm). Install into wood or
steel: drill 1/8” (3mm). Mount with (2)
M3.5 x 32mm screws.
12. Test, turn key on, open door
13. Replace cover, snap lid from top,
secure with security screw
6400 QUICK INSTALL
FEB2018
Subject to change
without notice.
2306 Airport Rd • Waterford, MI 48327, USA
Phone: 248-673-9898 • Fax: 248-673-1246
Taylor House • 34 Sherwood Road • Bromsgrove, Worcestershire • B60 3DR • England
T
el:
+44
(0)1527
520
999
•
Fax:
+44
(0)1527
501
999
•
[email protected] •
www
.sti-emea.com
MOUNTING HOLESMOUNTING HOLES
Mounting holes Mounting holes
SWITCH SETTINGS 1 2 3 4 5 6 7 8
Arming - immediate OFF*
Arming - 15 second delay ON
Trip - immediate OFF*
Trip - 15 second delay ON
Shut-off based on duration
Shut-off approx. 3 sec. after
Duration - 30 second alarm OFF* OFF*
Duration - 180 second alarm OFF ON
Duration - continuous alarm ON OFF
Duration - annunciator mode ON ON
Low battery detection ON OFF*
Low battery detection OFF ON
Volume - high ON*
Volume - low OFF
Relay function OFF OFF*
Relay function ON ON
*default
OFF*
ON
door closes
(switches 4 & 5)