pow (control voltage display)
The "pow" LED indicates the state of the control voltage.
OFF Control voltage (24 V) is missing or is too low, not ready, fatal system
error
Flashes slowly (0.5 Hz) Bootloader is active, firmware is defective
(Flashes in sync with err LED).
Flashes briefly (3 Hz, 30 ms
ON)
Identifying the device (IdentifyDevice parameter)
(Flashes in sync with err LED).
ON Device ready, error diagnosis by means of PacDrive controller possible
err (error display)
The error LED (err) indicates errors.
OFF No error
Flashes slowly (0.25 Hz) SERCOS error
Flashes slowly (0.5 Hz) Bootloader is active, firmware is defective
(Flashes in sync with pow LED).
Flashes quickly (2 Hz) General error or device not entered in the PLC configuration as a real
device.
Flashes long
Flashes for a long time (0.5
Hz, 1.8 s ON)
SERCOS ring interruption
Flashes quick
Flashes briefly (3 Hz, 30 ms
ON)
Identifying the device (IdentifyDevice parameter)
(Flashes in sync with pow LED).
ON Fatal system error
bus err (SERCOS bus error display)
The error LED (err) indicates errors.
OFF Normal operation
ON / Flashes Bus error (problem with fiber-optic cable connection, e.g. transmitting
power is too low or too high, cable break, etc.)
slnk (SERCOS link display)
The "slnk" LED indicates the state of the SERCOS bus (to X7 SERCOS via copper
cable).
OFF SERCOS ring break
ON SERCOS ring OK
4.1 Indicators and control elements
ELAU AG PacDrive Power Supply PS-5 and Distribution Box DB-5 Page 17