SAFETY INSTRUCTIONS
Please read and follow these safety guidelines to safeguard yourself and others:
• GSM dialler ESIM022 (later referred to as “the system” or “the device”) contains a built-in
radio transceiver operating in GSM 900/1800 MHz bands.
• DO NOT use the system where it can cause potential danger and interfere with other
devices – such as medical devices.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impact.
• DO NOT attempt to repair the system yourself – any repairs must be carried out by fully
qualied personnel only.
Please, use the 12-15 V 300 mA DC power supply unit that meets the EN
60950-1 standard. Any additional device you connect to the system, such as a
computer, must also be powered by an EN 60950-1 approved supply. When con-
necting the power supply to the system, mind the polarity terminals. DO NOT
switch the polarity terminals places.
External power supply must be reachable
and can be connected to AC mains only
inside installation room with automatic
2-pole circuit breaker capable of discon-
necting circuit in the event of short circuit or
over-current condition. Open circuit breaker
must have a gap between connections of
more than 3 mm and the disconnection cur-
rent 5 A.
Phase
DC 12-15 V
Null
PE
ESIM022
USB cable
Disconnect the mains power before installing. Never install or carry out mainte-
nance during stormy weather. The electric socket that powers the system must be
easily accessible. In case of power cut, the system is powered by a back-up battery
(if any).
WARNING: Only use the approved back-up battery with the system to avoid re
or explosion. Take care when connecting positive and negative battery terminals.
To switch the system o, unplug the external electric power supply, disconnect
the back-up battery or any other linked device that the system is powered from. A
blown fuse cannot be replaced by the user. The replacement fuse has to be of the
kind indicated by the manufacturer (Fuse F1 model – miniSMDC 0,5A).
If you use a computer for the device conguration, it must earthed.

3
3
ESIM022 User manual v1.0
Copyright © “ELDES UAB”, 2013. All rights reserved
It is strictly forbidden to copy and distribute information in this document or pass
to a third party without an advanced written authorization from “ELDES UAB”.
“ELDES UAB” reserves the right to update or modify this document and/or related
products without a warning. Hereby, “ELDES UAB” declares that the GSM dialler
ESIM022 is in compliance with the essential requirements and other relevant pro-
visions of Directive 1999/5/EC. The declaration of conformity may be consulted at
www.eldes.lt.
The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see
right) or its documentation indicates that the product must not be disposed of to-
gether with household waste. To prevent possible harm to human health and/or the
environment, the product must be disposed on in an approved and environmentally
safe recycling process. For further information on how to dispose of this product
correctly, contact the system supplier, or the local authority responsible for waste
disposal in your area.
Contents
1. GENERAL INFORMATION .............................................................................................. 5
1.1. Function ..........................................................................................................................................5
1.2. Operation Description...................................................................................................................5
1.3. Technical Specications ...............................................................................................................6
1.4. Connector Functionality ...............................................................................................................7
1.5. Connection Circuit......................................................................................................................... 8
1.6. System installation....................................................................................................................... 8
1.7. Power supply and battery ............................................................................................................9
2. System control commands ......................................................................................... 10
2.1. Power supply and power management .................................................................................. 10
2.2. Programming ESIM022 via mobile phone............................................................................... 12

4
4
EN ESIM022 User manual v1.0
Limited Liability
The buyer agrees that the system will reduce the risk of re, theft, burglary or other danger but
that it does not guarantee against the occurrence of such events.
“ELDES UAB” will not take any responsibility for the loss of personal eects, property or revenue
whilst using the system. The liability of “ELDES UAB” is limited to the value of the system
purchased.
“ELDES UAB” is not aliated with any mobile/wireless/cellular provider and is therefore not
responsible for the quality of such services.
Manufacturer Warranty
The system carries a 24-month manufacturer warranty from “ELDES UAB”.
The warranty begins the day the system is purchased by the user and the receipt must be retai-
ned as proof of purchase date. The warranty remains valid only if the system is used as intended,
following all guidelines outlined in this manual and in accordance with the operating conditions
specied.
The warranty is void if the system has been exposed to mechanical impact, chemicals, high
humidity, uids, corrosive and hazardous environments or force majeure factors.
Dear Customer,
Thank you for choosing to purchase the GSM dialler ESIM022. Your thoughtful decision will
ensure reliable solution for many years as all ELDES products are manufactured to meet
the highest standards.
We are condent that you will be completely satised with your product. However, in the
unlikely event that you do experience a problem, please contact the dealer from whom
you made your purchase.
UAB ELDES
www.eldes.lt
Contents of Pack
Item Quantity
1. ESIM022 ...............................................................1
2. User manual.........................................................1
Not included:
• SIM card – we recommend you get a contract SIM, not Pay As You Go.
• Back-up battery - can be obtained from your local distributor.
• miniUSB cable - can be obtained from your local distributor.
• Temperature sensor - can be obtained from your local distributor.
• Microphone - can be obtained from your local distributor

5
5
ESIM022 User manual v1.0
1. GENERAL INFORMATION
ESIM022 is a micro-controller based device intended to receive alarm/restore events by SMS text
message or phone call and control an electrical appliance via the GSM network.
Examples of using the system:
• Notication of system events, such as arming/disarming, alarm/restore from non-GSM alarm
system.
• Non-GSM alarm system arming/disarming by SMS text message.
• Any electrical appliance control: lighting, watering, heating etc.
• Remote reboot of the “frozen” systems, such as computer network or a server.
• Notication of failure or restoration of an electronic device by SMS text message or phone call.
Main features:
• Conguration by SMS text message and PC.
• Up to 2 users for system conguration, control and acceptance of system event notications
by SMS text messages or phone calls.
• 2 inputs customizable as NC or NO.
• Input Z1 mode: digital.
• Input Z2 modes: digital or temperature sensor for 1 external temperature sensor connection.
• 1 open-collector output for electrical appliance control or non-GSM alarm system arming/
disarming (keyswitch).
• Tamper switch for system sabotage detection.
• Optional back-up battery to maintain the power for up to 12 hours and notify the user
regarding mains power loss and restore.
• Periodic self-test notication by SMS text message to user phone number.
• Customizable notication texts.

6
6
EN ESIM022 User manual v1.0
2. TECHNICAL SPECIFICATIONS
2.1. Electrical & Mechanical Characteristics
Supply voltage.....................................................12-15 V 300 mA max
Average current used in idle state ................... 16 mA
Supported back-up battery (optional) ............9 V 250 mAh Ni-Mh 6F22
GSM modem frequency......................................900/1800 MHz
Number of outputs .............................................1
Output circuit.......................................................Open collector output.
Output is pulled to COM when
turned ON.
Maximum commuting output values...............30 V 200 mA
Number of inputs................................................2
Supported temperature sensor model............Maxim®/Dallas® DS18S20, DS18B20
PCB dimensions...................................................71x50x27 mm
Enclosure dimensions ........................................96x59x34 mm
Operating temperature range...........................-30…+55 °C (-35...+55 °C with limitations)
Humidity ...............................................................0-90% RH @ 0... +40 °C (non-condensing)
2.2. Main Unit, LED Indicator & Connector Functionality
Front Back
C1
Z2
DCCOM
COM
SIM CARD
TAMPER
RESET
MIC
LED
ANT
USB
Z1
OPEN
G S M
MO DE M
FW
+
BATTERY
-
F1
1 R
OUT
1 2

7
7
ESIM022 User manual v1.0
Main Unit Functionality
ANT GSM antenna
FW Pins for rmware update
TAMPER Tamper switch
GSM MODEM GSM network 900/1800 MHz modem
RESET Button for restoring default settings
SIM CARD SIM card slot / holder
LED Light-emitting diode indicating system status
USB Mini USB port
MIC Microphone connector
-/+ Backup battery slots
F1 0.5A fuse
LED indication Description
OFF No power supply
Flashing every 30 ms SIM card is not present / PIN code enabled
Flashing every 0,5 sec. Searching for GSM network
Flashing every 1 sec. Connected to GSM network/system operating successfully
Connerctors Description
Z1 Digital input terminal
COM Common terminal
Z2 Digital input terminal/temperature sensor data terminal (DATA)
DC Positive power supply terminal
C1 Open-collector output terminal/temperature sensor power
supply terminal (+4V)

8
8
EN ESIM022 User manual v1.0
2.3 Wiring Diagrams
General wiring Temperature sensor wiring
ESIM022
Alarm system or other appliance
+12V
PGM2
PGM1
Z1 Z2 COMCOM DC C1
ESIM022
DS18S20, DS18B20
Temperature sensor
COMZ1 Z2 DC C1COM
GND
GND
DATA
DATA
+4V
+4V
Output wiring
ESIM022
Alarm system or other appliance
+12 V
+
Electrical
appliance
+
COMZ1 Z2 DC C1COM
3 4
5

9
9
ESIM022 User manual v1.0
3. INSTALLATION
• The system should be installed indoors, in stationary environment ONLY.
• For the connection of input/output terminals, use 0.50 mm2thread unshielded cable of up to
100 meters length.
1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for
more details).
2. When placing the system, follow the recommendations:
Never install in the following locations:
• inside the metal cabinet
• closer than 20 cm to the metal surface
and/or power lines
3. Disable the PIN code request of the SIM card by inserting it into a mobile phone and following
the proper menu steps.
4. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM022
system.
8
OPEN
7
910
5. If you have obtained a back-up battery with your system, insert it into the battery slots. Take
care when connecting positive and negative battery terminals.
6. Power up the system and wait until the LED indicator lights up indicating system status. Wait
until the LED indicator starts ashing every 1 second indicating successful connection to GSM
OPEN
11
6

10
10
EN ESIM022 User manual v1.0
network and system operation (see 2.2. Main Unit, LED Indicator & Connector Functiona-
lity for more details).
7. Set the phone number for User 1.
8. Set system date and time.
9. Once the system is fully congured, it is ready for use.
ATTENTION: The system is NOT compatible with pure 3G SIM cards. Only 2G/GSM SIM cards
and 3G SIM cards with 2G/GSM prole enabled are supported. For more details, please con-
tact your GSM operator.
ATTENTION: We also recommend you to disable call forwarding, voice mail/text mes-
sage reports on missed/busy calls and similar services that might cause incorrect sys-
tem operation. Please contact your GSM operator for more details on these services and
how to disable them.
NOTE: For maximum system reliability we recommend you do NOT use a Pay As You Go
SIM card. Otherwise, in the event of insucient credit balance on the SIM card, the system
would fail to make a phone call or send SMS text messages.
NOTE: We advise you to choose the same GSM SIM provider for your system as for your
mobile phone. This will ensure the fastest, most reliable SMS text message delivery service
and phone call connection.
NOTE: Even though the installation process of ESIM022 is not too complicated, we still
recommend to perform it by a person with basic knowledge in electrical engineering and
electronics to avoid any system damage.

11
11
ESIM022 User manual v1.0
4. GENERAL OPERATION DESCRIPTION
GSM dialler ESIM022 uses the GSM network for event transmission by SMS text message. When
one of the two available preset numbers dials the system, it answers the call and the user can
listen for up to 60 seconds to what is going on in the premises. This function operates only when
a microphone is connected. The system will ignore SMS requests and phone calls coming from
unknown phone numbers.
The system has 2 digital inputs (normally closed or normally open) for alarm system’s PGM output
or detection device connection, such as magnetic door contact. By connecting the input to the
non-GSM alarm system’s PGM output, you will be able to receive an SMS text message or pho-
ne call regarding system alarm/restore, arming/disarming and other events depending on alarm
system conguration. In addition to being informed by SMS text message or phone call regarding
alarm and restore events of the inputs, the users can control one electrical appliance by connec-
ting it to the open-collector output. For example, users can turn ON or OFF the heating, lighting,
lift the gates, blinds etc. The output can also be used for arming/disarming by connecting it to one
of the alarm system zones congured as a keyswitch.
The system is protected from sabotage by built-in tamper switch resulting in user notication by
SMS text message if the enclosure is tampered.
ESIM022 can be equipped with an external temperature sensor for temperature monitoring.
The system may be equipped with a back-up battery allowing to maintain the power and notify
the user by SMS text message regarding mains power loss and restore events.

12
12
EN ESIM022 User manual v1.0
5. CONFIGURATION METHODS
!!! In this user manual the underscore character ”_” represents one space character. Every
underscore character must be replaced by a single space character. There must be no
spaces or other unnecessary characters at the beginning and at the end of the SMS text
message.
5.1. SMS Text Messages
SMS
In order to congure the system by SMS text message, send the text command to
the ESIM022 system phone number from any of the preset user phone numbers.
The structure of SMS text message consists of the parameter and value. For some
parameters the value does not apply e. g. STATUS. The variables are indicated in
lower-case letters, while a valid parameter value range is indicated in brackets.
5.2. ELDES Conguration Tool
Cong
Tool
Software ELDES Conguration Tool is intended for ESIM022 GSM dialler congu-
ration via USB port locally. This software simplies system conguration process
by allowing to use a personal computer in the process. Before starting to use EL-
DES Conguration Tool software, please read the user guide provided in the soft-
ware’s HELP section.
ELDES Conguration Tool is freeware and can be downloaded at: www.eldes.lt/
en/download
NOTE: Conguration by USB cable and ELDES Conguration Tool software does not require
the external power supply to be connected and/or back-up battery to be inserted in the device.
6. USER PHONE NUMBERS
The system supports up to 2 user phone numbers identied as User 1 through 2. When the phone
number is set, the user will be able to congure the system by SMS text messages as well as to
receive the alarm phone calls and alarm/restore SMS text messages from the system (see 10.
ALARM/RESTORE NOTIFICATIONS).
The system ignores any incoming calls and SMS text messages from a non-preset phone number.
To set User 1 phone number is mandatory, while User 2 is optional. The supported phone number
formats are the following:
• International (with plus) – The phone numbers must be entered starting with plus and
an international country code in the following format: +[international code][area code][lo-
cal number], example for UK: +4417091111111.

13
13
ESIM022 User manual v1.0
• International (with 00) – The phone numbers must be entered starting with 00 and an
international country code in the following format: 00[international code][area code][local
number], example for UK: 004417091111111.
• Local – The phone numbers must be entered starting with an area code in the following
format: [area code][local number], example for UK: 017091111111.
Set user phone
number
SMS
SMS text message content:
NRup:ttteeellnnuumm
Value: up – user phone number slot, range – [1... 2];
ttteeellnnuumm – up to 15 digits user phone number.
Example: NR1:+4417091111111
By dialling the phone number of the system for the
rst time, the system will reject the phone call and au-
tomatically set up the phone number as User 1 phone
number that the phone call has been made from. This
feature DOES NOT apply to User 2 phone number.
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View user phone
number
Cong
Tool This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Delete user phone
number SMS
SMS text message content:
NR2:
Example: NR2:
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
ATTENTION: NEVER add a phone number of the device’s SIM card as a user phone number!
ATTENTION: Once User 1 phone number is set, it will be restricted to modify it only.

14
14
EN ESIM022 User manual v1.0
7. DATE AND TIME
The system comes equipped with internal real-time clock (RTC) that keeps track of the current
date and time. Once the system is up and running, the user must set the correct date and time,
otherwise the system will not operate properly. After shutting down and starting up the system,
the date and time must be set again.
Set date and time SMS
SMS text message content:
CLK:yyyy.mm.dd_hr:mn
Value: yyyy – year; mm – month, range – [01... 12]; dd
– day, range – [01... 31]; hr – hours, range – [00... 23];
mn – minutes, range – [00... 59].
Example: CLK:2013.03.16_14:33
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View date and
time SMS
SMS text message content:
STATUS
Example: STATUS
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
For more details on how to view system’s information that may include date and time, please
refer to 13. SYSTEM INFORMATION. STATUS SMS.

15
15
ESIM022 User manual v1.0
8. INPUTS
The system comes equipped with 2 inputs identied as Z1 and Z2. Depending on the input
and selected mode, the inputs are designed for dierent detection device connection, such as
motion detectors, door contacts, temperature sensors etc. (see 8.1. Input Z1 and 8.2. Input
Z2). Once the detection device is triggered, the system will send a notication to the user phone
number (see 10. ALARM/RESTORE NOTIFICATIONS).
8.1 Input Z1
Input Z1 operates in Digital mode. The system monitors the input voltage resulting in the input
state change. Normally, this input is used for for PGM output connection of non-GSM alarm
system, motion detectors, door contacts and other passive or active digital level sensors.
The system follows this pattern for input Z1:
a) Monitors input voltage ranging from 0 mV through 3000 mV every 100 millisecond.
b) Veries if the set up threshold (by default – 1500 mV) is not exceeded.
c) By default, the input is set as NO (normally open), therefore if the voltage drops below
the threshold, it will result in input state change to alarm followed by notifying the user
by SMS text message and/or phone call.
d) When the voltage rises above the threshold, it will result in input state change to restore
followed by notifying the user by SMS text message or phone call (only for alarm state).
Set threshold SMS
SMS text message content:
Z1VLEV:vthr
Value: vthr – threshold, range - [0... 3000] mV
Example: Z1VLEV:2350
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Set input as NC
(normally closed) SMS
SMS text message content:
ZONE1:NC
Example: ZONE1:NC
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.

16
16
EN ESIM022 User manual v1.0
Set input as NO
(normally open) SMS
SMS text message content:
ZONE1:NO
Example: ZONE1:NO
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View input state SMS
SMS text message content:
STATUS
Example: STATUS
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View real-time
input voltage Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View input
parameters Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
For more details on how to manage the alarm/restore notications, please refer to 10 ALARM/
RESTORE NOTIFICATIONS.
For more details on how to view system’s information that may include input state, please refer to
13. SYSTEM INFORMATION. STATUS SMS.
8.2 Input Z2
Input Z2 can operate in one of the following modes at a time:
• Digital – The system monitors the input voltage resulting in the input state change. Nor-
mally, this mode is used for PGM output connection of non-GSM alarm system, motion de-
tectors, door contacts and other active or passive digital level sensors. This mode is set by
default. For more details on how to manage the Digital mode, please refer to 8.2.1. Digital
Mode.
• Temperature Sensor – The input converts to 1-Wire interface for temperature sensor
connection. For more details on how to manage the Temperature Sensor mode, please re-
fer to 8.2.2. Temperature Sensor Mode.

17
17
ESIM022 User manual v1.0
Set input mode
as Temperature
Sensor
SMS SMS text message content:
ZONE2:TEMP
Example: Z2:TEMP
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Set input mode as
Digital
SMS SMS text message content:
ZONE2:DIG
Example: Z2:DIG
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View input mode
parameters Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
8.2.1 Digital Mode
When Digital mode is set, the system follows this pattern:
a) Monitors input voltage ranging from 0 mV through 3000 mV every 100 millisecond.
b) Veries if the set up threshold (by default – 1500 mV) is not exceeded.
c) By default, the input is set as NO (normally open), therefore if the voltage drops below
the threshold, it will result in input state change to alarm followed by notifying the user
by SMS text message and/or phone call.
d) When the voltage rises above the threshold, it will result in input state change to restore
followed by notifying the user by SMS text message and/or phone call (only for alarm
state).

18
18
EN ESIM022 User manual v1.0
Set threshold SMS
SMS text message content:
Z2VLEV:vthr
Value: vthr – threshold, range - [0... 3000] mV
Example: Z2VLEV:1390
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Set input as NC
(normally closed)
SMS SMS text message content:
ZONE2:NC
Example: ZONE2:NC
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Set input as NO
(normally open)
SMS SMS text message content:
ZONE2:NO
Example: ZONE2:NO
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View input state SMS SMS text message content:
STATUS
Example: STATUS
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
View real-time
input voltage Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.

19
19
ESIM022 User manual v1.0
View input
parameters Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
For more details on how to manage the alarm/restore notications, please refer to 10. ALARM/
RESTORE NOTIFICATIONS.
For more details on how to view system’s information that may include input state, please refer to
13. SYSTEM INFORMATION. STATUS SMS.
8.2.2 Temperature Sensor Mode
The system may be equipped with 1 temperature sensor intended for temperature measurement
in the surrounding area. The temperature value is automatically updated in accordance with the
set up period (by default – every 60 minutes). To set a dierent temperature update period, please
refer to the following conguration methods.
Set temperature
update period
SMS
SMS text message content:
PTEMP:temp-per
Value: temp-per – temperature update period, range
– [3... 71000000] minutes.
Example: PTEMP:45
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Adding, Removing and Replacing Temperature Sensor
To add a temperature sensor to the system, proceed as follows:
1. Shutdown the system.
2. Wire up the temperature sensor to the terminals (see 2.3. Wiring Diagrams).
3. Power up the system.
4. Enable the temperature sensor.
To enable the temperature sensor, please refer to the following conguration method.
Enable
temperature
sensor
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.

20
20
EN ESIM022 User manual v1.0
To view the temperature value of the temperature sensor, please refer to the following congu-
ration methods.
View
temperature
value and
temperature
sensor name
SMS SMS text message content:
STATUS
Example: STATUS
Cong
Tool
This operation may be carried out from the PC using the
ELDES Conguration Tool software.
If a temperature sensor becomes faulty, it is recommended to remove it or replace it by a func-
tional sensor.
Remove/
replace faulty
temperature
sensor
Cong
Tool This operation may be carried out from the PC using the
ELDES Conguration Tool software.
Temperature Info SMS
The system supports an SMS text message identied as the Temperature Info SMS, which is auto-
matically delivered to the preset user phone number if the minimum (MIN) (by default – 20 °C) or
maximum (MAX) (by default – 30 °C) temperature threshold of the external temperature sensor
is exceeded.
Optionally, a name for a temperature can be set that will be included in the Temperature Info SMS
when delivered to the preset phone number. This feature allows easier identication of the tem-
perature sensor.
To set and view the MIN, MAX temperature thresholds and name of the temperature sensor,
please refer to the following conguration methods.
Table of contents
Popular Telephone Accessories manuals by other brands

Polycom
Polycom Vortex EF2201 Brochure & specs

Siemens
Siemens optiPoint application module Information and important operating procedures

Blueant
Blueant Optus 124YES user manual

Grandstream Networks
Grandstream Networks HT812 user guide

AmazonBasics
AmazonBasics B00MJKZI8S quick start guide

Iridium
Iridium Extreme PTT user manual