Electrolux BGEFU1 User manual

CR096-RG52A1BGEU
2020550A7563
20140319
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
your air conditioner.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for
details.

1
CONTENTS
Use the remote controller within a distance of 8
meters from the appliance, pointing it towards the
receiver. Reception is confirmed by a beep.
Location of the remote controller.
8m
CAUTIONS
The air conditioner will not operate if curtains, doors or other materials
block the signals from the remote controller to the indoor unit.
Prevent any liquid from falling into the remote controller. Do not expose
the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller. either move
these appliances or consult your local dealer.
The remote controller is powed by two dry batteries(R03/LR03X2) housed in the
rear part and protected by a cover.
(1) Remove the cover by pressing and sliding off.
(2) Remove the old batteries and insert the new batteries,placing the(+) and (-)
ends correctly.
(3) Reattach the cover by sliding it back into position.
When the batteries are removed, the remote controller erases all progra-
mming. After inserting new batteries, the remote controller must be reprogrammed.
NOTE:
Replacing batteries
Handling the remote controller
2
Keep the remote controller where its signals can
reach the receiver of the unit.
CAUTIONS
Do not mix old and new batteries or batteries of different types.
Do not leave the batteries in the remote controller if they are not
going to be used for 2 or 3 months.
Do not dispose batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
MODE
SWING TEMP
SHORTCUT
FAN
SPEED
FAN
SPEED
TIMER
OFF
TIMER
OFF
RESET LOCK
LED
FOLLOWME
LED
FOLLOWME
TIMER
ON
TIMER
ON
TURBO
SELFCLEAN
TURBO
SELFCLEAN
DIRECT
SLEEP
FRESH
SLEEP
FRESH
2
3
5
7
8
8
8
9
9
10
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Function buttons .................. .........................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Adjusting air flow direction............................................................
Timer operation...............................................................................

Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03 2)
Remote Controller Specifications
1. Operating Mode: AUTO, COOL, DRY, HEAT and FAN.
2. Timer Setting Function in 24 hours.
3. Indoor Setting Temperature Range : 62 F~86 F.
4. Full function of LCD (Liquid Crystal Display).
OO
Environment
Signal Receiving
Range
Performance Feature
3 4
RG52A1/BGEFU1
23 F~140 F
OO
NOTE Please do not select HEAT mode
if the machine you purchased is cooling
only type. Heat mode is not supported by
the cooling only appliance.
Function buttons
1
2
Each time the button is pressed, the operation
mode is selected in a sequence of following:
3
MODE Button
4
5
ON/OFF Button
Operation starts when this button is pressed
and stops when this button is pressed again.
AUTO
COOL
DRY
HEAT
FAN
6
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
FAN Button
1
2
4
3
7
8
5
6
9
10
11
13
12
14
SLEEP Button
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, FAN
SPEED or ON/OFF button is pressed.
Active/Disable sleep function. It can maintain
the most comfortable temperature and save
energy. This function is available on COOL,
HEAT or AUTO mode only .
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset
temperature at cooling or heating operation
in the shortest time(if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
ON/OFF
MODE
FAN
TEMP
SHORT
CUT
TIMER ON
TIMER OFF
SLEEP
SWING DIRECT
LED FOLLOW ME
TURBO SELF CLEAN
SELF CLEAN Button
Active/Disable Self Clean function.
Under self clean mode, the air conditioner
will automatically clean and dry the
evaporator and keep it as fresh for the next
operation.
- Buttons design is based on typical model and might be
slightly different from the actual one you purchased, the
actual shape shall prevail.
-All the functions described are accomplished by the unit, if
the unit has no this feature, there is no corresponding
operation happened when press the relative button on the
remote controller.
-When there are wide differences between Remote controller
Illustration and USERS MANUAL on function description,
the description on USERS MANUAL shall prevail.
NOTE:

5 6
SHORTCUT Button
TIMER ON Button
TIMER OFF Button
Used to restore the current settings or
resume previous settings.
On the first time connecting to the power, if
push the SHORTCUT button, the unit
will operate on AUTO mode, 80 F, and fan
speed is Auto.
Push this button when remote controller is
on, the system will automatically revert back
to the previous settings including operating
mode, setting temperature, fan speed level
and sleep feature(if activated). And transmit
the signals to the unit.
If push this button when remote controller is
off, the system will only resume the previous
settings and will not transmit the signals to
the unit. And the sleep feature is disable.
If pushing more than 2 seconds, the system
will automatically restore the current
operation settings including operating mode,
setting temperature, fan speed level and
sleep feature(if activated ).
O
SWING Button
DIRECT Button
Used to change the louver movement and set
the desired up/down air flow direction.
The louver changes 6 in angle for each press.
Used to stop or start horizontal louver auto
swing feature.
O
UP Button( )
Push this button to decrease the indoor
temperature setting in 1 F increments
to 62 F.
o
O
DOWN Button( )
7
9
11
10
12
13
14
8
Press this button to initiate the auto-on time
sequence. Each press will increase the auto-
timed setting in 30 minutes increments. When
the setting time displays 10, each press will
increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program,
simply adjust the auto-on time to 0.0.
Press this button to initiate the auto-off time
sequence. Each press will increase the auto-
timed setting in 30 minutes increments. When
the setting time displays 10, each press will
increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program,
simply adjust the auto-off time to 0.0
Push this button to increase the indoor
temperature setting in 1 F increments
to 86 F.
o
O
11
22
44
33
77
88
55
66
99
10 10
11 11
13 13
12 12
14 14
ON/OFF
ON/OFF
MODE
MODE
FAN
FAN
TEMP
TEMP
SHORT
CUT SHORT
CUT
TIMER ON
TIMER ON
TIMER OFF
TIMER OFF
SLEEP
SLEEP
SWING DIRECT
SWING DIRECT
LED FOLLOW ME
LED FOLLOW ME
TURBO SELF CLEAN
TURBO SELF CLEAN
NOTE: Press and hold and buttons
together for 3 seconds will alternate the
temperature display between the C & F
scale.
OO
FOLLOW ME Button
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote control
will send this signal to the air conditioner every
3 minutes interval until press the Follow Me
button again. The air conditioner will cancel
the Follow Me feature automatically if it does
not receive the signal during any 7 minutes
interval.
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.

7 8
Indicators on LCD
Transmission Indicator
Temp./Timer display
Fan speed display
Sleep Display
Mode display
ON/OFF display
This transmission indicator lights when remote
controller transmits signals to the indoor unit.
Displays the current operation mode. Including
auto( ), cool( ), dry( ), heat( ) (Not
applicable to cooling only models), fan( )
and back to auto( ).
Displays the temperature setting(62 F~86 F). When
you set the operating mode to FAN, no temperature
setting is displayed. And
OO
if in the TIMER mode, shows
the ON and OFF settings of the TIMER.
Displayed by pressing the ON/OFF button.
Press the ON/OFF button again to remove.
Displays the selected fan speed, AUTO(no display)
and three fan speed levels " " (LOW) "
(HIGH) can be indicated.
The fan speed is AUTO when the operating mode is
either AUTO or DRY.
"
(MED) " "
Displayed under sleeping operation.
Press the SLEEP button again to remove.
Note:
All indicators shown in the figure are for the purpose
of clear presentation. But during the actual operation
only the relative functional signs are shown on the
display window.
FOLLOW ME Display(on some models)
Displayed when FOLLOW ME function is activated.
TIMER ON display
TIMER OFF display
Displayed when TIMER ON time is set.
Displayed when TIMER OFF time is set.
How to use the buttons
Cooling /Heating/Fan operation
MODE
UP/DOWN
FAN
ON/OFF
Ensure the unit is plugged in and power is
available.
1. Press the button to select COOL,
HEAT(cooling & heating models only) or
FAN mode.
2. Press the buttons to set the
desired temperature.
3. Press the button to select the fan speed
in four steps- Auto, Low, Med,or High.
4. Press the button to start the air
conditioner.
The temperature can
be set within a range of 62 F~86 F in 1 F
increments.
OO O
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.
NOTE
Auto operation
MODE
UP/DOWN
ON/OFF
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the button to select Auto.
2. Press the button to set the
desired temperature. The temperature can
be set within a range of 62 F~86 F in 1 F
increments.
3. Press the button to start the air
conditioner.
OO O
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
2
2
1
1
4
3
3
ON/OFF
MODE
FAN
TEMP
SHORT
CUT
TIMER ON
TIMER OFF
SLEEP
SWING DIRECT
LED FOLLOW ME
TURBO SELF CLEAN
ON/OFF
MODE
FAN
TEMP
SHORT
CUT
TIMER ON
TIMER OFF
SLEEP
SWING DIRECT
LED FOLLOW ME
TURBO SELF CLEAN

910
Dehumidifying operation
MODE
UP/DOWN
ON/OFF
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the button to select DRY mode.
2. Press the buttons to set the
desired temperature.
3. Press the button to start the air
conditioner.
The temperature can
be set within a range of 62 F~86 F in 1 F
increments.
OO O
In the Dehumidifying mode, you can not switch the
fan speed. It has already been automatically controlled.
NOTE
Adjusting air flow direction
Use the SWING and DIRECT button to adjust
the desired airflow direction.
1. When push the DIRECT button, the horizontal
louver changes 6 degree in angle for each
push.
2. When push the SWING button, the louver
will swing up and down automatically.
When the louver swing or move to a
position which would affect the cooling
or heating effect of the air conditioner,
it would automatically change the
swing/moving direction.
NOTE:
2
2
1
1
3
Timer operation
Press the TIMER ON button can set the auto-on
time of the unit. Press the TIMER OFF button
can set the auto-off time of the unit.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases by half an hour between 0
and 10 hours and by one hour between 10 and
24 hours.
3. After setting the TIMER ON ,there will be a one
second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set
desired Auto-off time. Each time you press the
button, the time increases by half an hour
between 0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a
one second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "H " will disappear and the set temperature
will re-appear on the LCD display window.
ON/OFF
MODE
FAN
TEMP
SHORT
CUT
TIMER ON
TIMER OFF
SLEEP
SWING DIRECT
LED FOLLOW ME
TURBO SELF CLEAN
ON/OFF
MODE
FAN
TEMP
SHORT
CUT
TIMER ON
TIMER OFF
SLEEP
SWING DIRECT
LED FOLLOW ME
TURBO SELF CLEAN

11 12
The effective operation time set by the remote controller for the timer function
is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20,
21, 22, 23 and 24.
CAUTION
!
Example of timer setting
Start
Off
6 hours later
(Auto-on Operation)
The TIMER ON feature is useful when you want
the unit to turn on automatically before you return
home. The air conditioner will automatically start
operating at the set time.
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting
of starting operation time and the signal
2. Press the TIMER ON button to display "6.0H
on the TIMER ON display of the remote
controller.
3.
"H"
will show on the display area.
"
Wait for 3 seconds and the digital display
area will show the temperature again. The
"TIMER ON" indicator remains on and this
function is activated.
TIMER ON
Example:
Set
Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when you want the
unit to turn off automatically after you go to bed. The
air conditioner will stop automatically at the set time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of
stopping operation time and the signal "H" will
show on the display area.
2. Press the TIMER OFF button to display "10H " on
the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
OFF" indicator remains on and this function is
activated.
TIMER OFF
Example:
On
Stop
2 hours later
after setting
Set
To stop the air conditioner 2 hours after setting and
start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display
2.0H on the TIMER OFF display.
3.
4. Press the TIMER ON button again to display 10H
on the TIMER ON display .
5.
Press the TIMER ON button.
Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON OFF" indicator remains on and this function is
activated.
TIMER OFF TIMER ON
(On Stop Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in
the morning when you wake up or when you return
home.
Example:
COMBINED TIMER
(S both ON and OFF )etting timers simultaneously
Start
10 hours later
after setting

13 14
Example:
TIMER ON TIMER OFF
(Off Start Stop operation)
This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.
To start the air conditioner 2 hours after setting,
and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0H on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display
5.0H on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON OFF" indicator remains on and this function
is activated.
Off
Stop
Start
2 hours later
after setting
5 hours later
after setting
Set
The device could comply with the local national regulations.
In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not approved by the party responsible for compliance could
void user s authority to operate the equipment.
NOTE:
This manual suits for next models
1
Table of contents