Under-Cabinet Hood
RH30WC40G S
30" UNDER-CABINET HOOD
Features
Nominal Width
Installation Type
Air Discharge
Air Delivery (CFM)
Blower Type
Electronic Controls with LCD Display
Fan Speeds
Sound Level (dBA)
Dual Halogen Lights
Dishwasher Safe Stainless Steel Filters
Exhaust Duct
Duct Required
Accessories
Charcoal Filter – PN# RHCF400GS
Specifications
Product Dimensions –
Height
Width
Depth
Voltage Rating
Connected Load (kW Rating) @120 Volts
‡
Amps@120 Volts
Shipping Weight (Approx.)
Sones Rating
* Ventilation system is preset to recirculate air inside with no ducting. Converting to exterior
exhaust is optional.
‡ For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate
ground wire. Appliance must be grounded for safe operation.
NOTE: Always consult local and national electric codes. Check local building codes for
installation requirements, as they may vary per locale. Refer to Product Installation Guide
for detailed installation instructions on the web at electroluxappliances.ca.
Specifications subject to change.
LCD Electronic Controls
An array of versatile options with easy-to-
read blue displays, including a convenient
kitchen timer, fan-speed selection and a
delayed power-off option. The hoods also
feature sensors that will turn them on
automatically if they sense heat or smoke.
Dual-Centrifugal Fans
Move air quietly and quickly– up to
400 cu.ft. of air per minute.
Stainless Steel Filters
Dishwasher safe for easy cleaning.
Halogen Lighting
For bright illumination of the
cooktop surface.
electroluxappliances.ca
30"
Wall Mount
Vertical or Horizontal
400
Dual Centrifugal
Yes
4
68.0
Yes
Yes
Convertible*
7" Round
or 3-1/4" x 10"
Optional
4-3/4"
29-7/8"
20"
120V/60Hz /15A
0.36
2.89
30 Lbs.
6.6
Wall OvensRefrigerators Warmer DrawersCooktopsBuilt-In Ranges
Freestanding
Ranges
Microwaves
Vent HoodsFreezersUnder CounterWashers / Dryers Dishwashers /
Kitchen Cleanup
Under-Cabinet Hood
RH30WC40G S
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
CANADA •5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352 •electroluxappliances.ca
RH30WC40GS 12/10 © 2010 Electrolux Home Products, Inc. Printed in Canada
30" Under-Cabinet Hood Specifications
•
Product Weight – 27 Lbs.
•
Wall-Mount Installation – can be ducted vertically
or horizontally.
•
Ventilation system is preset to recirculate air inside with no ducting
system required. Exhausting air outside is optional, using either vertical
or horizontal ducting sytem. (Refer to Ducted Option Specifications for
outside ventilation.)
•
Sones Rating – 6.6
•
Voltage Rating –120V /60 Hz/ 15 Amps
•
Connected Load (kW Rating) @120 Volts = 0.36 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
•
Amps @120 Volts = 2.89 Amps
•
Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
•
Connect vent hood with copper wire only.
•
Minimum installation height allowed from bottom of hood to cooking
surface is 24"- 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
•
To improve performance, optional Charcoal Filter (PN# RHCF400GS)
recommended for use with recirculating system.
Ducted Option Specifications
•
For outside ventilation.
•
Exhaust Duct Required – 7" round or 3-1/4" x 10"
•
To accommodate pre-existing, off-center ductwork, vent hood can be
installed up to one inch on either side of hood center. In extreme
off-center installation, one end of duct connector can be modified to
clear electrical cable clamp.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).
•
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
•
Cold weather installations should have additional backdraft damper
installed.
•
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.ca for detailed instructions.
Optional Accessories
•
Charcoal Filter – (PN# RHCF400GS).

Other manuals for RH30WC40GS

1

This manual suits for next models

1

Other Electrolux Ventilation Hood manuals

Electrolux EFP60424OX User manual

Electrolux

Electrolux EFP60424OX User manual

Electrolux ICON RH30WC60GS User manual

Electrolux

Electrolux ICON RH30WC60GS User manual

Electrolux WEGL1030CN User manual

Electrolux

Electrolux WEGL1030CN User manual

Electrolux EFG90563OX User manual

Electrolux

Electrolux EFG90563OX User manual

Electrolux LFV316K User manual

Electrolux

Electrolux LFV316K User manual

Electrolux EFC 90344 User manual

Electrolux

Electrolux EFC 90344 User manual

Electrolux EFC60420 User manual

Electrolux

Electrolux EFC60420 User manual

Electrolux EFI739X User manual

Electrolux

Electrolux EFI739X User manual

Electrolux EFV55464OW User manual

Electrolux

Electrolux EFV55464OW User manual

Electrolux EFC60001K User manual

Electrolux

Electrolux EFC60001K User manual

Electrolux EFI 6358 User manual

Electrolux

Electrolux EFI 6358 User manual

Electrolux PLHV36W6CC User manual

Electrolux

Electrolux PLHV36W6CC User manual

Electrolux EFC925SAR User manual

Electrolux

Electrolux EFC925SAR User manual

Electrolux ERCM9010AS User manual

Electrolux

Electrolux ERCM9010AS User manual

Electrolux 740 D User manual

Electrolux

Electrolux 740 D User manual

Electrolux DF 1090 Specification sheet

Electrolux

Electrolux DF 1090 Specification sheet

Electrolux LFP326S User manual

Electrolux

Electrolux LFP326S User manual

Electrolux EFC 9460 User manual

Electrolux

Electrolux EFC 9460 User manual

Electrolux U24211 EFT 530 User manual

Electrolux

Electrolux U24211 EFT 530 User manual

Electrolux EFC60401OW User manual

Electrolux

Electrolux EFC60401OW User manual

Electrolux E:Line ERCE9020AS User manual

Electrolux

Electrolux E:Line ERCE9020AS User manual

Electrolux LFG616W User manual

Electrolux

Electrolux LFG616W User manual

Electrolux 316488521 User manual

Electrolux

Electrolux 316488521 User manual

Electrolux AEG DD9693-M User manual

Electrolux

Electrolux AEG DD9693-M User manual

Popular Ventilation Hood manuals by other brands

ELICA HAIKU manual

ELICA

ELICA HAIKU manual

Miele DA 5341 D installation instructions

Miele

Miele DA 5341 D installation instructions

Franke ALLIANCE 764-16 OPAL User instructions

Franke

Franke ALLIANCE 764-16 OPAL User instructions

Franke DB 10078 Instructions for use and installation

Franke

Franke DB 10078 Instructions for use and installation

Futuro Futuro RECANO ISLAND installation manual

Futuro Futuro

Futuro Futuro RECANO ISLAND installation manual

AVG AVN-308CS2 owner's manual

AVG

AVG AVN-308CS2 owner's manual

Fujioh FX-900 Operation manual

Fujioh

Fujioh FX-900 Operation manual

Signature SHD6XPERI Instructions for use

Signature

Signature SHD6XPERI Instructions for use

KOBE CH7936SQB installation instructions

KOBE

KOBE CH7936SQB installation instructions

Jenn-Air 30" COMMERICAL STYLE WALL-MOUNT CANOPY RANGE... Installation Instructions and Use & Care Guide

Jenn-Air

Jenn-Air 30" COMMERICAL STYLE WALL-MOUNT CANOPY RANGE... Installation Instructions and Use & Care Guide

ROBLIN ALTIMA 77 SANS MOTEUR Dimensions

ROBLIN

ROBLIN ALTIMA 77 SANS MOTEUR Dimensions

vissari SUPERIOR Series Installation & operating manual

vissari

vissari SUPERIOR Series Installation & operating manual

Beko 01M-8809143200-0722-16 user manual

Beko

Beko 01M-8809143200-0722-16 user manual

Apelson CGK60SSR1 instructions

Apelson

Apelson CGK60SSR1 instructions

Bartscher Kompakt 300 instruction manual

Bartscher

Bartscher Kompakt 300 instruction manual

THERMA Big Dipper 40000 Series quick start guide

THERMA

THERMA Big Dipper 40000 Series quick start guide

VentAHood Equipped with Magic Lung Blower Owner and maintenance guide

VentAHood

VentAHood Equipped with Magic Lung Blower Owner and maintenance guide

German pool 2102-28 operating instructions

German pool

German pool 2102-28 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.