CalibratingtheLeftFueiTank:
I. Set the aircraft angle
of
attack for cruise flight with unusable fuel in the tank.
2.
Turn the power to the FL-2 off. Set the Selector Switch to the left position.
3.
Push and hold the Enter Button on the back
of
the unit.
Turn on the power. Wait 3 seconds and release the Enter
Button. This is your first calibration point. Each time you
push and hold the Enter Button you will advance to the
next cal point. A maximum
of9
cal points may be set.
4.
Place the Selector Switch into the center position. The FL-2 will display the
current fuel level for this calpoint.
If
"EOOO"
is
displayed, this is for cal
point 1(empty fuel level). If"Pxxx" is displayed, this indicates a partial fuel
level cal point.
If
"Fxxx" is displayed, this indicates the
full fuel level cal point and is the last cal point.
To program (change) the fuel level for this calibration
point, push and hold the Enter Button on the back
of
the
FL-2 for 3 seconds. To change the blinking digit, move
the Selector Switch from the center position to the left or right. To blink the
next digit to the right, tap the Enter Button on the back
of
the FL-2. To exit
the programming
of
the fuel level for this calibration point and stop the
blinking
of
a digit, push and hold the Enter Button on the back
ofthe
FL-2
for 3 seconds.
5. Place the Selector Switch into the right position. The FL-2 will display the
last programmed Sensor Counts for this cal point. Tap the Enter Button on
the back
of
the FL-2, the display will start blinking and the Sensor Counts
for the current fuel level in the tank will be displayed. Wait for the display to
stabilize and tap the Enter Button to lock the current Sensor Counts into the
display and stop the blinking.
If
you want to manually program the Sensor Counts, push
and hold the Enter Button at the back
of
the FL-2 (with
the Sensor Counts displayed and not blinking) until the
thousands digits starts to blink.
CalibratingtheRightFuelTank:
Calibrate the right tank using the left tank calibration procedure with the
following change: When the procedure calls for the Selector Switch to be
placed
in
the left position, place it in the right position and when
it
is to be
placed in the right, place it into the left.