manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elkay
  6. •
  7. Switch
  8. •
  9. Elkay 350A-1 Manual

Elkay 350A-1 Manual

This manual suits for next models

1

Other Elkay Switch manuals

Elkay 350A-1 Operating instructions

Elkay

Elkay 350A-1 Operating instructions

Elkay pushbutton Manual

Elkay

Elkay pushbutton Manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Illuminated Pushbutton Timer &
Touch Timer (2 wire) are part of the Elkay
family of switches, timers and detectors which
save energy and increase convenience in and
around your home, garden or premises.
Rating at 240V ac 50Hz
• Time Delay: 2 min - 2 hrs
• All load types 16A - Including lighting loads that
are LED, Compact Fluorescent, Incandescent
and Resistive
• These switches cannot be used with contactors.
Please use Elkay (3 Wire) Master Timers
and sensors
Usage
The Pushbutton/Touch Timers are general purpose
time controls. Applications for suitable use include
lighting and fans with lighting. The Timers can be
used independently or as a master unit when using
Activator trigger switches. One master product only
for each circuit being switched with additional
Activator units at other positions where multiple
switches are required.
When used with some low wattage lighting, low
voltage lighting, LED ttings and 2D uorescents,
please ensure a capacitor of 4 microfarads is
tted at the load across the switch live and neutral.
Only one is required per circuit (Part no. PFCC-1).
IMPORTANT: Please note that it is essential that
the Live In and Live Out are identied prior to
commencing the installation and steps 1-3 are
followed precisely. No neutral is required on this
product (See diagram 1). Do not install the
switch timer with the mains power on as this
can damage the product.
Do not megger test or insulation resistance test
this product. Remove before testing or test circuit
prior to tting.
Activator and Momentary Fitting
When connecting with Activators use three core cable
connecting the Live In, Live Out and Trigger terminals
as shown in diagram 2. The optional wire to the Activators
only applies to the 350A-1 Pushbutton Activator units
and is ideal for retrotting (See diagram 2).
Please note that the Trigger terminal is the third terminal.
Momentary or activating switches can also be used
and can be connected back to the Live In and the Trigger
terminal on the master.
This product requires a 24 hour power supply. The battery
inside the unit recharges when the light source or
appliance is switched OFF. Where the supply may be
interrupted or isolated regularly we must recommend
our products from the three wire range.
Your Elkay unit compatible with a single gang, 25mm
deep British Standard accessory plate. Please ensure
that the top and bottom lugs are removed from metal
wall boxes prior to tting. For 16mm boxes Elkay
provide a spacer plate (Product no. 220A-1) to take
box depth to 25mm.
Installation Steps
DO NOT APPLY MAINS UNTIL INSTRUCTED!
Step 1 – Ensure that the mains power to the circuit is
switched OFF. Place the previously indentied Live
in into the L in terminal and switch Live into the
Lout terminal.
Step 2 – Switch the battery ON using dip switch 4 - you
will notice a red LED light ashing on the front of the
unit, which will be ashing rapidly. Whilst this is in
action please select the desired timings by selecting
the appropriate time setting shown in diagram 3.
Step 3 – Switch Mains ON and wait for switch to
latch onto the mains and light source /appliance to
switch OFF.
Continued overleaf...
–
ILLUMINATED
PUSHBUT
TON
& TOUCH TIMER
350A-1 /360A-1
2 wire
Instruction Guide
BROOK DESIGN HARDWARE LTD
BDH
BDH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Step 4 – At one minute prior to the end of the timing
sequence, the red LED will begin to  ash continuously
for the last minute of operation. The blue locator
ring will then illuminate once the light source or
appliance has gone off .
Step 5 – To end the timing sequence prematurely,
press and hold the Pushbutton/Touch pad until the
red LED  ashes continuously indicating the last
minute countdown is in operation. Your light source
or appliance will be switched off after one minute.
Standby / Sleep Mode
If the Elkay Timer does not receive power then the unit
will put the unit into sleep mode to conserve the
battery. The unit will attempt to latch on to mains
power 25 times automatically before going to
sleep mode as mentioned above.
Diagram 3 – Time settings
Please note:
The black bar denotes the
position of the dip switch.
To manually reactivate the unit press and hold for
a period of 15 seconds approximately, the red
LED should start to  ash rapidly, release button, the
LED changes to a  ash every 3 seconds, press and
hold again until load switches off . Leave in OFF
condition for at least 30 minutes before re-pressing.
Emergency Light Fittings
When carrying out the 3 hr annual Emergency test
please ensure that during the test that this timer
is switched off at number 4 for the duration of
the test.
This intelligent timer can detect failed Emergency
 ttings or ballasts and may go into Standby Mode. If
this occurs remove the faulty emergency  tting and
follow the Standby/Sleep Mode notes above.
Diagram 1
Wiring diagram for a
single unit master.
Diagram 2
Wiring diagram for a Master
and Activator.
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
Master Activator
2 mins 5 mins 10 mins 20 mins 40 mins 60 mins 90 mins 120 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast BT17 9HU
T +44 (0)28 9061 6505
F +44 (0)28 9061 6518
E info@elkay.co.uk elkay.co.uk
BROOK DESIGN HARDWARE LTD
BDH
B
DH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Technical Helpline
For further help or assistance or information on this or other products in the range
please call the Elkay Technical team on +44 (0)28 9061 6505. Please call the Technical
helpline before returning any products to your stockist. In the unlikely event that you
have to return your product, please ensure you switch the battery off fi rst. These
instructions are available in other languages. Please refer to our website www.elkay.co.uk
Instrukcje są również dostępne w innych językach. Prosimy o zapoznanie się z
naszą stroną internetową www.elkay.co.uk lub www.elkaypolska.pl
Important Notice
All wiring should be carried out by a
competent person or a qualified electrician
and should be fitted to current IEE wiring
regulations BS 7671.The circuit should
be isolated before carrying out any work.
Failure to adhere to the instructions will
invalidate the warranty.
Elkay (Europe), 51C Milicka, Trzebnica, 55-100, Poland