USAGE
The slave units work in conjunction with all master timers to remotely
trigger the timing. Any combination of slaves can be wired to any
master, thus giving a variety of activation functions in one area all
operating one central timer.
All slave units are designed to control lighting, heating and ventilation.
POSITIONING – PIR SLAVE
Use the detection range to determine a suitable location for the PIR
sensor.When locating the position of the unit avoid subjecting the
sensor to direct sunlight. Ensure that the sensor is not adjacent to the
load. Do not site unit a vibrating surface or near a forced air heating
or ventilation.
MOUNTING AND INSTALLATION
Important Please notethat it is essential that the Live In wire and switch Live Out is identified prior to commencing
installation. Turn off mains supply before installation. Your Elkay unit is compatible with a single gang, 25mm deep, British
standard accessory plate. Please ensure that the top and bottom lugs are removed, if fitted, from metal wall boxes prior to
fitting. Ensure that there is adequate space for wiring.
Step 1 Please select wiring diagram as per combination of master and slave unit, by checking your individual part number
and then wire as per correct diagram.
Step 2 On touch button and PIR slave, the battery jumper is located in the top right hand corner and must be fixed on the
two upper terminals.
Step 3 On the PIR slave, ensure that the lux level adjustment has been adjusted to the desired level via the rotary lux level
adjuster. The mains supply must be disconnected before the lux level is adjusted. Please ensure that an insulated screwdriver
is used for lux level adjustment.
Step 4 Timing should be set on the master unit as per its individual instructions.
INSTALLATION NOTES
N.B After installation the PIR will require approximately 5 minutes to initialise.
5 - 7m
4 - 6m
5 - 7m
3 - 4m
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
slaveswitch
slaveswitch fitting & operating instructions
The slave switch is part of the Elkay family of switches, timers and detectors which save
energy and increase convenience in and around your home, garden or premises.
Patent Pending Inst. Ref. No SLA01 Rev. No.: 11/07
Incandescent 16A
Fluorescent 16A
Compact 16A
Fluorescent
Resistive 16A
Time Delay
2mins - 2hours.
RATING AT 240V AC
OFF ON
slave battery jumper
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
Patent Pending Inst. Ref. No SLA01 Rev. No.: 11/07
j07318-slavesCORRECTION.qxd 19/11/07 14:40 Page 1

OUTDOOR INSTALLATION
Please note only products in the Elkay energy outdoor range are suitable for use outdoors. Elkay energy outdoor can only
be used in conjunction with the surface mount box supplied.
Take the surface mount box and remove the knock out section. If required and to ensure IP66 waterproof rating, please use a
suitable M20 cable gland. Mount the surface mount box on a secure surface using the mounting pack supplied. Place screw
cover seals over the mounting screws.
Turn off mains supply before proceeding with installation -Install as per previous slave instructions - Mount unit onto
surface mount box using the fixing screws at all four corners - Place screw hole seals over left and right screw cavities - Clip on
front fascia plate - Re-instate mains supply.
OPERATION PUSH BUTTON/TOUCH SENSOR
1. Press the slave pushbutton/touchpad and your light source or appliance will be switched on initiating the timing sequence
of the master unit it is attached to.
2. At any time during the working of the light source or appliance, the pushbutton/touchpad can be pressed to reset the
timing sequence on the master unit to the originally set time. E.g When the timing period is 30 minutes, if the
pushbutton/touchpad is pressed 15 minutes into sequence, the timer will re-set for a further 30 minutes.
3. Toend the timing sequence prematurely, press and hold the slave pushbutton/touchpad for approximately 2.5 seconds the
last minute of the timing sequence will now be initiated on the master timer. Your light source or appliance will now be
switched off after 1 minute
4. At one minute prior to the end of the timing sequence, the red LED will begin to flash continuously for the last minute of
operation, this will only happen on the master timer allowing it to be identified from the slave units. The blue locator ring will
then illuminate once the light source or appliance has gone off, on both the master and slave unit.
OPERATION PIR SENSOR
1.In standard operation the PIR slave will now sense body heat when passing through the detection zone. Each time the slave
PIR is triggered the red LED will light and reset the timer on the master unit it is connected to, back to the start of the timing
period. The unit will the wait 20 seconds approximately before allowing the PIR unit to sense and re-trigger the timing period
again.
2. If no one is present in the room or the detection zone is notpassed through during its set time period the timer will time
out turning off the lights or application and the blue indicator ring will light up.
3. The SlavePIR unit willonly trigger the lights or application if the ambient light level is below what has been set on the lux
level adjustment.
4. When the ambient light level is light enough so the lights would not normally come on with PIR use, the override switch
can be used to turn on the lights for the set period time. This can be used in times where additional light is required in a room.
Tooperate, press the PIR lens, the red indicator LED will light to show it has been pressed and the timing will begin, in the last
minuteof timing the red LED will flash.
5. When the ambient light level is dark enough that the PIR is in normal operation, the override switch can be used to disable
the PIR and the lights turned off indefinitely or until the override switch is pressed. This can be done by pressing the PIR lens,
the red LED will flash rapidly to indicate the PIR has been disabled and can be re-enabled simply by pressing the lens again.
NB, The PIR lens will require approximately 1 minute to initialize.
OPERATION NOTES
If your Elkay touch or PIR slave does not receive power for a period of over 7 days, please turn the battery off by re-positioning
the jumper to the lower two terminals. (see diagram)
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified Electrician in accordance with the current IEE Wiring
Regulations. If unit is faulty return to place of purchase.
TECHNICAL HELPLINE
For further help, or information on this and the other products in the Elkay range visit www.elkay.co.uk or call 01675 468222.
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
Patent Pending Inst. Ref. No SLA01 Rev. No.: 11/07
ElkayElectrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
Patent Pending Inst. Ref. No SLA01 Rev. No.: 11/07
SLAVE FITTING - TWO WIRE MASTER WITH PUSH BUTTON, TOUCH TIMER OR PIR SLAVE
MULTIPLE SLAVE FITTING
SLAVE FITTING - THREE WIRE MASTER WITH PUSH BUTTON, TOUCH TIMER OR PIR SLAVE
OFF ON
slave battery jumper