Emerson EAD30E1 User manual

EMERSON
QUIET KOOL
OWNER'S MANUAL
DEHUMIDIFIER
Please read this manual carefully before operating your appliance and retain it for future reference.
MODEL: EAD30E1 EAD50E1
EAD70E1

THANK YOU!
Congratulations on your purchase and
welcome to the EMERSON QUIET K00L. Your
new EMERSON QUIET K00L Air Dehumidifier
combines high-efficiency operation with
portable convenience.
By following the operating and care
instructions in this manual, your
dehumidifier will provide you with
many years of reliable service.

TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
Basic Safety Precautions ----------------------------------------- 01
Electrical Safety ------------------------------------------- 03
PARTS AND FEATURES
Key Parts and Components ------------------------------------------- 04
Caster Installation ------------------------------------------- 04
Control Panel ------------------------------------------- 05
CHOOSING A LOCATION ------------------------------------------- 08
AUTOMATIC DEFROST ------------------------------------------ 08
CONTINUOUS MODE ------------------------------------------ 08
MAINTENANCE ------------------------------------------ 09
TROUBLESHOOTING
Before Calling for Service ------------------------------------------10
ERROR CODE ------------------------------------------ 11

IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always
read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and either the word "WARNING" or "CAUTION" These words mean:
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to property.
BASIC SAFETY PRECAUTIONS
WARNING To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow
basic precautions, including the following:
•Do not attempt to repair or replace any part of your dehumidifier unless it is specifically recommended in this manual.
All other services should be referred to a qualified technician.
•lf the power cord becomes worn or damaged, the cord should only be replaced by a qualified service technician using
genuine replacement parts.
•The dehumidifier should be plugged into its own grounded circuit (13Amp, 60Hz, 115 V AC circuit).
•Do not plug other appliances into the same outlet; it can overload the circuit and cause a fire or electric shock.
• Do not remove the round grounding prong from the plug. It can result in a risk of electric shock.
•This appliance is not designed for use by young children. Young children should be supervised to ensure that they do
not play with or climb on the unit.
•Be sure all packaging materials are removed from the appliance before use.
•Do not disassemble or modify the appliance or the power cord. It can cause a risk of electric shock or fire.
•Do not place the power cord or appliance near a heater, radiator, or other heat source. It can cause a risk of electric
shock or fire.
•Do not use this or any appliance near flammable gases or liquids or other combustibles, such as gasoline, benzene,
thinner, etc. It can cause a risk of electric shock or fire.
•Make sure the power cord is plugged firmly and completely into the outlet. Failure to do so can cause a risk of electric
shock or fire.
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
•Do not start or stop this appliance by plugging in or unplugging the power cord. It can cause a risk of electric shock.
•lf the appliance is making unusual sounds or is emitting smoke or an unusual odour, turn it off and unplug it
immediately. Failure to do so can cause a risk of electric shock or fire.
•Do not use if the electrical socket is loose or damaged. It can cause a risk of electric shock or fire.
• Do not operate with wet hands. It can cause a risk of electric shock or fire.
•Do not use this or any electrical appliance if you smell gas. It can cause a risk of fire or explosion.

•Turn off and unplug the dehumidifier before cleaning to avoid the risk of electric shock.
•Do not clean the unit with water. Water can enter the unit and damage the insulation, creating a shock hazard. lf water
enters the unit, unplug it immediately and contact Customer Service. It can cause a risk of electric shock.
•To avoid possible cuts, avoid contacting the metal parts of the dehumidifier when removing or reinstalling the filter. It
can cause a risk of personal injury.
•Do not block the air inlet or outlet of the appliance. Reduced airflow will result in poor performance and could damage
the unit.
•Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling on the cord. It can cause a
risk of electric shock and damage.
•Always turn off and unplug the appliance when it will not be used for extended periods of time. This conserves energy
and reduces the chance of accidents.
•Install the appliance on a sturdy, level floor capable of supporting up to 110 lbs (50 kg). Installation on a weak or uneven
floor can result in the risk of property damage and personal injury.
•Make sure the appliance is the correct size for the area you wish to use the dehumidifier. Using an appliance that is the
wrong size can waste energy and damage the unit.
•Close all doors and windows to the room for most efficient operation.
•To prevent damage to the surface finish, use only a soft cloth to clean the dehumidifier. Do not use wax, thinner, or a
strong detergent.
•To prevent spills and property damage, be sure to drain the appliance properly.
•To prevent the coils from freezing, do not operate the appliance if the room temperature is lower than 41℉(5℃).
•Do not position the dehumidifier so that pets or house plants are exposed to the direct air flow. It can cause a risk of
injury to pets or house plants.
•This dehumidifier is designed for normal household use only.
•Do not drink the water from the drain pan. Dispose of it properly outdoors or down the drain.
•Do not operate appliance without the filter securely in place. Operation without the filter could damage the unit.
•Clean the filter every two weeks, or more often if needed.
ELECTRICAL SAFETY
WARNING - Electric Shock Hazard
•Failure to follow these instructions can result in death, fire, or electrical shock.
•This unit must be properly grounded.
•Do not, under any circumstances, cut or remove the ground prong.
•lf you do not have a properly grounded outlet, or if there is any doubt that the outlet is not properly grounded, a
qualified electrician should check the outlet and circuit, and, if necessary, install a properly grounded outlet.
•This dehumidifier must be plugged into a grounded 60 Hz, 115 VAC outlet protected by a 13 amp time delay fuse or
circuit breaker.
•Do not alter or modify the plug or cord of this dehumidifier. If the power cord becomes worn or damaged, the cord
should only be replaced by a qualified service technician using genuine replacement parts.
•Do not use with an extension cord.
SAVE THESE INSTRUCTIONS

KEY PARTS AND COMPONENTS
1. Air Outlet Grill
2. Control Panel
3. Carrying Handle
4. Bucket
5. Water Level Indicator
6. Casters
7. Air Intake Grill
8. Drain hole
9. Power cable
10. Product manual (Not shown)
CASTER INSTALLATION
1.Remove casters from bucket.
2.Install the casters.
Tilt the dehumidifier no more than 45°and insert
the casters by pushing them in. Make sure the ring around the casters is flush
against the bottom of the dehumidifier.

PARTS AND FEATURES
CONTROL PANEL
CONTROL PANEL
1) When first operating the dehumidifier, run it in Continuous mode for 24 hours.
2) Power On and Off- Press the POWER button once to manually turn the unit on. Press the POWER button once more to
turn the unit off.
3) Humidity Selection - Press the ∨or ∧buttons to choose the desired relative humidity in the room. Each press of the
button will change the desired room humidity by 5%. The room humidity can be set from 35%-80%, or continuously. The
unit will cycle on and off to maintain the humidity level chosen on the digital display. lf you want the dehumidifier to
operate continuously regardless of the room humidity, press the MODE button until you see “CO” on the digital display.
This will enable continuous operation and the “Continuous” indicator will light up on the control panel.
4) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and Low.
The fan speed can be visually distinguished by the fan speed indicators on the control panel.
5) Timer Auto On- To program the unit to automatically turn on, press the TIMER button when the unit is off. Press the
∨or ∧buttons to increase or decrease the timer in 30 min increments (0.5 hours) up to 10 hours. After 10 hours, each
press of the button will increase the timer in 1 hour increments up to 24 hours. Once the desired time is reached, the
unit will automatically turn on.
Timer Auto Shut-Off- To program the unit to automatically turn off, press the TIMER button when the unit is on. Each
press of the or buttons will change the timer setting in 30 min increments (0.5 hours) up to 10 hours. After 10 hours, each
press of the or buttons will increase or decrease the timer in 1 hour increments up to 24 hours. Once the desired time is
over, the unit will automatically power off.
NOTE: Fan will continue to run even when the compressor is off. This is normal and allows the unit to circulate air and
operate more efficiently.

PARTS AND FEATURES
6) Bucket Full - When the water bucket is full of water, the unit will automatically shut off, make a beeping noise, and the
Bucket Full Indicator will light up. The dehumidifier will not function until the water bucket is emptied and placed back
inside the unit. The bucket should be cleaned every few weeks to prevent the growth of mold, mildew and bacteria. Use
a mild detergent to clean the bucket. Once clean, completely dry the bucket and place it back inside the dehumidifier.
NOTE: Hold bucket with both hands when emptying.
NOTE: When the bucket is full or removed from the machine, the compressor will turn off, but the fan will continue to
run for a few minutes. This is completely normal. The dehumidifier will not be removing moisture from the air at this
time.
NOTE: When removing moisture from the air, the dehumidifier will exhaust warm air from the side exhaust vent.
NOTE: Do not place a full bucket on the floor, because the bottom is uneven.
7) Clean Filter- When the filter needs to be cleaned, the filter indicator will light up (after 250 hours of use). Remove the
filter from the back of the unit by using your thumbs to press down on the filter tabs directly above the filter. Clean the
filter with warm, soapy water. Dry thoroughly before replacing the filter. Once the filter is completely dry, place the filter
back in the unit and press the
FILTER button to reset the filter indicator.
CAUTION: DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER
NOTE: Do not clean filter in dishwasher

PARTS AND FEATURES
8) Pre-set Modes - Preset humidity level settings allow the user to easily move the dehumidifier room-to-room and select
the corresponding mode for the location in which the dehumidifier is operating for optimum performance. Press the
MODE button to choose from Bedroom, Living Room or Basement.
9) Child-Lock Mode-To lock the control panel, press and hold the TIMER button for3 seconds.
Locking the control panel prevents someone from accidentally changing the settings. When locked the LOCK Indicator will
light up. Press and hold the TIMER button for 3 seconds to unlock the control panel.
CHOOSING A LOCATION
A dehumidifier operating in a basement will have little or no effect in
drying out an adjacent enclosed storage area, such as a closet,
unless there is adequate circulation of air in and out of the area.
•Do not use outdoors. This dehumidifier is intended for indoor use only.
• Place the dehumidifier on a smooth, level floor surface that is strong enough
to support the unit with a full bucket of water.
•Allow at least 12”-18” of airflow on all sides.
•Place the dehumidifier in an area where the temperature will not
fall below 41°F(5°C). The coils can become covered with frost at
temperatures below 41°F(5°C), which may reduce performance.
•Use the dehumidifier in cooking, laundry, bathing and dishwashing areas
that have excessive moisture. NOTE: Place the dehumidifier away from a clothes dryer.
•Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored.
•Use the dehumidifier in a basement to help prevent moisture.
•The dehumidifier must be operated in an enclosed area to be most effective.
•Close all doors, windows and other outside openings to the room.
AUTOMATIC DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost
disappears. When the coils are completely defrosted, the compressor or fan (depending on the model) will automatically
restart and dehumidification will resume.
CONTINUOUS MODE-GARDEN HOSE INSTALLATION AND SETUP
Water can be automatically emptied by attaching a hose to the continuous drainage port on the back of the dehumidifier.
This will allow the unit to run continuously (depending on the selected humidity level) without having to empty the water
bucket. To drain, simply attach a standard garden hose (not included). The thread standard for garden hoses in the US
and its territories is known as GHT or garden hose thread" which has an outer diameter of 1 1/16 inches (1.0625 inches
or27.0 mm) and a pitch of 11 5 TPI.

•Place dehumidifier on a level surface.
•Unscrew the cap on the back of the unit to access the garden hose nozzle
•Thread a garden hose (not supplied) onto the accessible nozzle, lead to a floor drain and cut to length. Make sure that
there are no kinks or knots in the garden hose. (See picture below) Turn on the unit and press the MODE button until set
to CONTINUOUS.
Garden Hose Installation Reference Guide
IMPORTANT NOTES:
Placing the dehumidifier on an uneven surface or improper hose installation may result in water filling up the bucket and
causing the unit to shut off. Empty bucket if shutoff occurs, then check dehumidifier location and hose for proper setup.
The bucket must be in place and securely seated for the dehumidifier to operate.
MAINTENANCE
Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any
maintenance on the unit.
Clean or Replace Filter - Refer to Operating Instructions Clean Filter section
Clean the Unit Housing-
1) Keep the unit from being exposed directly to the sun to prevent color fading.
2) Clean the surface with a damp cloth and dry it with a soft towel.
Storing the Unit for an Extended Period of Time or Transporting the Unit
1) Clean or replace filter- Refer to Operating Instructions Clean Filter section
2) Turn off and unplug the unit
3) Empty any excess water
4) The unit should be stored in a cool & dry place.

TROUBLESHOOTING
BEFORE CALLING FOR SERVICE
Before you call for service, review this list. lt may save you some time and expense. This list includes common
occurrences that are not the result of a defect in workmanship or materials.
Problem
Possible Causes
Solutions
Dehumidifier does
not start
•The dehumidifier is unplugged.
•Make sure the dehumidifier's plug is pushed
completely into the outlet.
•The fuse is blown /circuit
breaker is tripped.
•Check the house fuse / circuit breaker box and
replace fuse or reset breaker.
•Dehumidifier has reached its
present level or the bucket is full.
•The dehumidifier automatically turns off when
either condition occurs. Change to a lower setting
or empty the water bucket and replace properly.
•Bucket is not in the proper position.
•The bucket must be in place and securely seated
for the dehumidifier to operate.
•Power Failure.
•There is a protective time delay (up to 3 min.) to
prevent tripping of the compressor overload. For
this reason, the unit may not start normal
dehumidification for 3 min. after it is powered
back on.
Dehumidifier does
not dry the air as it
should
•Not enough time allowed for unit to
remove moisture.
•When first installed, allow at least 24 hours to
maintain the desired dryness.
•Airflow is restricted.
•Make sure there are no curtains, blinds ,or
furniture blocking the front or back of the
dehumidifier. See the CHOOSING A LOCATION
section.
•Dirty filter.
•Seethe CLEAN FILTER section.
•The Humidity Control may not be set
low enough.
•For drier air, press the "∨" button to lower the
percent humidity desired in the room, or set the
dehumidifier to CO for maximum dehumidification.
Doors and windows may not be closed
tightly.
•Check that all doors, windows, and other
openings are securely closed.
•Clothes dryer may be blowing moist
air into the room.
•Install the dehumidifier away from the dryer.
The dryer should be vented outside.
•Room temperature is too low.
•Moisture removal is best at higher room
temperatures. Lower room temperatures will
reduce the moisture removal rate. This model is
designed to operate at temperatures above 41 °
F(5°C).
Dehumidifier runs
too much
•The area to be dehumidified is too
large.
•The capacity of your dehumidifier may not be
adequate for the room size.
•Doors and windows are open.
•Close all doors and windows to the outside.

Problem
Possible Causes
Solutions
Frost appears on
the coils
•The dehumidifier has recently been
turned on or the room temperature is
below 41 °F(5°C).
•This is normal. Frost will usually disappear within
60 minutes.
Controls cannot be
set
•The compressor will turn off and the
fan will automatically continue to run
for approximately 3 minutes at a fixed
setting.
•This is normal. Wait approximately 3 minutes and
set the fan speed at the desired level.
•Air is moving through the unit.
•This is normal.
Water on the floor
•Hose connection may be loose.
•Check the hose connection. See the
CONTINUOUS MODE-GARDEN HOSE INSTALLATION
AND SET UP Section.
•Hose is attached but not draining
•Disconnect the hose if using the bucket; place
the hose near a drain.
ERROR CODE
For any questions or Technical Support,
Please call customer service:1-844-882-2622
Or email: serviceweb@canac.ca
Error Code
Description
EH
Humidity Sensor Fault
El or E2
Temperature Sensor Fault
E3
Lack of gas

EMERSON