SUNTEC SP1000C User manual

Suntec Industries (H.K.) Ltd.
Te l : +852 8130 0676
Fax: +852 8130 0671
URL: www.suntecind.com
READ AND STUDY MANUAL BEFORE USE
Swimming Pools Dehumidifier
SP500C Pro / SP1000C Pro / SP1500C Pro
OPERATING MANUAL

Suntec SP Series Swimming Pool Dehumidifiers are well used in swimming pools,
sauna rooms, museums, art galleries, storage, archives, etc. They reduce the
condensation on the windows, walls or other parts of the building in enclosed
structural environments, which prevents mould, corrosion, rot of the building.
Suntec SP Series Swimming Pool Dehumidifiers work on the basis of the
condensation principle with heat recycling, which means that the air from the room
is dehumidified but all of the energy used remains in the room in the form of heat.
The exchange principle guarantees the energy saving of up to 70%, which makes it
especially favorable from an ecological point of view.
Safety Instructions
l Do not allow children to play with or around the operating unit.
l Keep wiring and motor dry. Never operate the unit in standing water, rain and
snow, as this may create a risk of injury from electric shock.
l Do not use the adaptor.
l Do not operate the unit with a damaged power cable.
l Always operate the unit with an earthed plug and with an earthed supply.
l Extension cables must be earthed and be able to deliver the appropriate voltage
to the unit.
l Do not drop or throw the unit.
l Always operate the unit on a stable, level surface.
l Do not clog or block air intakes.
l Do not attempt to disassemble or repair the unit if you are not qualified to do so.
How to Use Dehumidifiers
Prior to installing your dehumidifier:
All dehumidifiers are factory assembled and tested prior to delivery. Please unpack
the carton and check whether there is any damage on the surface on the dehumidifier
and whether the accessories are complete as stated on the following included
accessories. If severe damage has occurred, please contact your supplier
immediately and do not attempt to install dehumidifier unit.
We also provide other kinds of dehumidifiers:
l Swimming Pool Dehumidifier with Built in Wifi
Technology
Models: SP500C Pro, SP1000C Pro, SP1500C
l Mobile Dehumidifiers with Timer Control
Models: SD600, SD1000
Models: ST600, ST1000
l Mobile Dehumidifiers with Humidistat, Timer Control &
Built in Wifi Technology
Models: ST601 Pro, ST1001 Pro
Please find out more from our website, www.suntecind.com

DECLARATION OF CONFORMITY
We, declare under sole responsibility that our models (SP500C Pro, SP1000C Pro and
SP1500C Pro) to which this declaration relates are in conformity with the following
standards:
EMC:
EN 55014 - 1:2006
,
EN 55014-2:1997+A1:2001
Electromagnetic Compatibility: emission requirement
EN 61000 - 3 - 2:2006
,
EN 61000-3-3:1995+A1:2001+A2:2005
Electromagnetic Compatibility: emission requirement.
LVD:
EN 60335 - 1: 2010+C1_2010+C2_2011+A1_2013+C1_2014+A2_2016
Safety of household and similar electrical appliance
- General requirements.
EN 60335 - 2-40: 2013+A1_2016
Particular requirements for electric heat pumps,
air conditioners and dehumidifiers.
Suntec Industries (H.K.) Ltd.
Design and Development
Included Accessories
Accessories
Accessory
Name
Qty
Description
Wall Mounted
Brackets
2
Used for wall mount
installation.
Exploded Screws &
Washes (fixing
wall)
4
Used for wall mount
installation.
Screws & Washes
(fixing
Dehumidifier)
4
Used for wall mount
installation.
Floor Mounted
Brackets
4
Used for floor mount
installation.
Universal Wheels
4
Used for mobile installation.
Water Drain Hose
(2 Meters)
1
Used for drain out water.
Condensation Pipe
Connector
1
Used for collect the
condensation water.

Installing your dehumidifier
How to install the dehumidifier on the wheels?
Step 1: Lift up the dehumidifier and let it sit on
the wooden box as show on figure below.
Step 2: Take out the wheels from the accessory
bag and screw those wheels into the screw
thread on the base.
Step 3: Put the dehumidifier on the flat ground.
Step 4: Adjust the wheels height according to the
ground condition.
How to install the dehumidifier on the ground?
Step 1: Lift up the dehumidifier and let it sit on
the wooden box as show on figure below.
Step 2: Take out the floor mounted brackets from
the accessory bag and screw those brackets into
the screw thread on the base.
Step 3: Put the dehumidifier on the flat ground.
Step 4: Adjust the brackets height according to
the ground condition.
Specifications
Model
SP500C Pro
SP1000C Pro
SP1500C Pro
Water Removal
(30°C/80%RH)
50L per day
100L per day
150L per day
Operating Temp.
Range
1° - 40° C
1° - 40° C
1° - 40° C
Operating
Humidity Range
10% to 90% RH
10% to 90% RH
10% to 90% RH
Compressor /
Refringent
Rotary / R410A
Rotary / R410A
Rotary / R410A
Power
Consumption
720Watt
1500Watt
2050Watt
Voltage / Cycle
220~240V/50Hz
220~240V/50Hz
220~240V/50Hz
Ampere
3.1A
6.5 Amps
8.9 Amps
Rated Air Flow
500 m3/h
800 m3/h
900 m3/h
Noise Level
42dB(A)
48dB(A)
48dB(A)
Installation/
mobility
Mobile/ Floor Mount
/ Wall Mount
Mobile/ Floor Mount
/ Wall Mount
Mobile/ Floor Mount
/ Wall Mount
Touch-pad
control panel
Yes
Yes
Yes
Remote Control
Yes
Yes
Yes
Defrost Type
Hot-gas bypass
Hot-gas bypass
Hot-gas bypass
Air Filter
Washable
Washable
Washable
Housing
Hard Plastic
Hard Plastic
Hard Plastic
Drain Hose
Length
2m
2m
2m
Cable Length
3m
3m
3m
W x D x H
65 x 27 x 55cm
89 x 29 x 76cm
100 x 33 x 80cm
Use Weight
35kg
56kg
71kg
Specifications are subject to change without notice. Some values are approximate.

Error Messages
Msg.
Description
ER01
Coil temperature sensor error
ER02
Ambient temperature sensor error
ER03
Humidity sensor error
ER04
Ambient temperature is over the operation range, which is 1 – 40oC.
ER05
High Pressure Switch off
ER06
Low Pressure Switch off
ER07
Communication error.
Maintenance
When it is not going to be used for a long time
l Set 80% RH as desired humidity for 3 or 4 hours to dry the inside of the
dehumidifier.
l Turn off the dehumidifier and then disconnect the power plug.
l Remove battery from Remote Control.
When the dehumidifier is going to be used again
l Make sure the air inlet and air outlet does not be blocked.
l Check the ground wire is connected correctly.
WARNING! Always unplug any dehumidifier before performing maintenance
procedures.
Warranty
SunTec warrants to the original purchaser that if, within a period of 12 months from
the date of purchase, this equipment is found to be defective either in original
materials or workmanship (excluding normal usage wear and/or mishandling or
abuse) the faulty part will be replaced free of charge upon presentation of the
appropriate evidence, provided the unit is returned to the original supplier. Shipping
expenses are not covered under the warranty.
How to install the dehumidifier on the wall?
Step 1: Choose the right installation position for
the wall support according to the size of installing
holes and the wall bracket holes position. The
installation position should guarantee the
dehumidifier in horizontal position. The position of
the exploded screw should be marked.
Step 2: Use the M8 percussive drilling machine to
drill holes of 8mm +-0.5mm depth. Then take the
nuts and gaskets off from the exploded screw and
fix them into the holes with the hammer.
Step 3: Install the wall bracket with the exploded
screw on the right position. Please take care to fix
the bracket well with the nuts and gaskets. And
don’t forget to keep the bracket in the right
direction during the installation.
Step4: Hang the dehumidifier on the wall bracket
and aim dehumidifier base installing holes at the
bracket holes. Fix the dehumidifier on the bracket
with the fix screws and gaskets.
Step5: Plug in the Condensation Pipe Connector
to the bottom central hole of the machine, then
connect a suitable piping.
How to change the filter on the dehumidifier?
Step 1: Use screwdriver undo two screws at the
bottom of the machine.
Step 2: Remove the metal cover filter plate and
let the HAF filter drop off.
Step 3: Change a new filter.

Position the dehumidifier
Before you turn on the machine, make sure there is enough space around the
machine. Keep it away from anything that could prevent airflow into and out of the
unit.
CAUTION! Never operate the Suntec SP dehumidifiers at temperature above 40oC.
It could damage the machine.
Operating Your Dehumidifier
Place the dehumidifiers in upright position
If the dehumidifier has been in a horizontal position for any time over a few minutes,
you must set it upright (vertical) for 45 minutes before starting.
Connect drainage system
You can find the hose wrapped around in the accessories pack. Unwrap the entire
hose, plug it into the water drain hose hole and run it into a drain, or bucket.
Note: Please find a suitable piping to connect the Condensation Pipe Connector at
the bottom of the machine if you find any condensation water leak out from there.
Plug in the electrical cord
Locate the electrical cord. Plug it into a standard outlet with the correct voltage and
amperage for the unit. If the unit experiences a loss of power, which can result from
a power interruption and overheated.
LCD Display – Cont.
“TOTAL” CLOCK. While “TOTAL”
CLOCK time is chosen, “TOTAL” wording
in the square box will flash for 3 sec. The
4 digits show how many DAYS the
machine has been used.
“JOB” CLOCK. While “JOB” CLOCK
time is chosen, “JOB” wording in the
square box will flash for 3 sec. The four
digits display how many HOURS and
MINUTES either the CURRENT JOB is
running or the LAST JOB has been run.
“oF” TEMPERTURE. While “oF”
TEMPERTURE function has been
chosen, “oF” wording in the square box
will flash for 3 sec and 3 digits figures
display the current ambient “oF”
temperature.
“oC” TEMPERTURE. While “oC”
TEMPERTURE function has been
chosen, “oC” wording in the square box
will flash for 3 sec and 2 digits figures
display the current ambient “oC”
temperature.

LCD Display – Cont.
“CURRENT” HUMIDITY. When the
machine is turned on, the default display
function goes to “CURRENT” HUMIDITY.
“CURRENT” wording in the square box will
flash for 3 sec and 2 digits Relative Humidity
figures display the current ambient humidity.
“SET” HUMIDITY. While “SET”
HUMIDITY function is chosen, “SET”
wording in the square box will flash for 3 sec
and the bottom 2 digits Relative Humidity
figures also flash continuously until the user
set the desired humidity which is from 25%
to 80%. “- - %RH” is the value beyond this
range, which read as nonstop
dehumidification.
“TIMER” CLOCK. While “TIMER”
CLOCK time is chosen, “TIMER” wording in
the square box will flash for 3 sec. The
bottom four digits show how many HOURS
and MINUTES the “TIMER” is. In STANDBY
mode, the four digits (- - : - -) flash
continuously until user sets the TIMER from
00:10 to 23:50 hours. Once the “TIMER” is
set and machine starts running, the four
digits displays remain running time of the
current TIMER., “- - : - -” is the value beyond
this range, which read as nonstop
dehumidification.
How to Use the Control Panel & Remote Control
Note: Find “Dry Connect” Mobile App Quick Start Manual for WiFi
connection.
Control Panel
Remote Control
“Up” Button
“Down” Button
LCD Display
Signal Receiver
Indication Light
“Start/Stop” Button
“Up” Button
“Down” Button
“Start/Stop” Button
“Menu” Button
“Menu” Button
WiFi Light

Touch Pad Keys:
On/Off. Press the On/Off key to start or stop the dehumidification.
l After press the On/Off key, the machine starts and performs a
compressor delay. The delay is up to a maximum of 180 seconds. (30
seconds delay for the first startup). The DELAY BAR flashes during this
delay period.
l When dehumidification starts, the red indication light changes to green
and LCD light up.
l When dehumidification starts, the LCD will display the current ambient
humidity.
l Press the START/STOP key again to turn the machine off. The green
indication light changes back to red and LCD light off.
MENU. Press the MENU key each time to choose the “CURRENT”
HUMIDITY, “SET” HUMIDITY; “TIMER” CLOCK, “TOTAL” CLOCK, “JOB”
CLOCK; “oF” TEMPERTURE, “oC” TEMPERTURE functions sequentially.
l In STANDBY MODE, the default function is “CURRENT” HUMIDITY,
When error messages are on, “TIMER” CLOCK, “TOTAL” CLOCK, “JOB”
CLOCK; “SET” HUMIDITY; “CURRENT” HUMIDITY, “oF” TEMPERTURE,
“oC” TEMPERTURE icons & wordings are disappear. Press MENU key again
to get back those displays.
“UP” KEY. Press the “UP” key to go to the Humidity Setting Mode and start
to set the desired air humidity,
The desired air humidity will be increased by 5% for every press on the “UP”
key. The default preset desired humidity is 60%RH. The adjustable range is
from 25% RH to 80% RH. “- - %RH” is the value beyond this range, which
read as nonstop dehumidification.
“DOWN”KEY. Press the “DOWN” key to go to the Humidity Setting Mode
and start to set the desired air humidity,
The desired air humidity will be decreased by 5% for every press on the
“DOWN” key. The default preset desired humidity is 25%RH. The adjustable
range is from 20% RH to 80% RH. “- - %RH” is the value beyond this range,
which read as nonstop dehumidification.
On/Off Indication Light:
Color
Status
Description
N/A
Off
Machine has been turned off.
Red
On
Machine has been turned on.
Green
On
Machine start dehumidification.
WiFi Indication Light:
Color
Status
Description
Red
Flash, 2 times per Sec.
EZ mode WiFi connection
Red
Flash, 1 time per Sec.
AP mode WiFi connection
Red
On
EZ/AP WiFi Connection Failure
Green
Flash, 1 time per Sec.
Connecting WiFi network.
Green
On
WiFi Connection successful.
Green
Flash, 2 times per Sec.
WiFi Connection Failure/ WiFi pcb is
disconnected.
LCD Display:
DELAY BAR
SERVICE.
RUN
RUN Mode. DEHUMIDIFICATION is ON.
SLEEP
SLEEP Mode. DEHUMIDIFICATION is OFF. It automatically
goes back to Running Mode again when the ambient humidity is
higher than the preset humidity.
This manual suits for next models