manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EMG
  6. •
  7. DC Drive
  8. •
  9. EMG DELTA VFD-MS300 Series Manual

EMG DELTA VFD-MS300 Series Manual

Popular DC Drive manuals by other brands

National Instruments NI MID-7604 user guide

National Instruments

National Instruments NI MID-7604 user guide

SOMFY Maestria WT Series instructions

SOMFY

SOMFY Maestria WT Series instructions

Danfoss VLT HVAC Design guide

Danfoss

Danfoss VLT HVAC Design guide

Trane TR150 Service manual

Trane

Trane TR150 Service manual

Chamberlain Garog D Series operating manual

Chamberlain Garog

Chamberlain Garog D Series operating manual

Parker PDS Series user guide

Parker

Parker PDS Series user guide

Binks QS-5012-1-CE Service manual

Binks

Binks QS-5012-1-CE Service manual

Danfoss VLT 2800 Series Quick setup

Danfoss

Danfoss VLT 2800 Series Quick setup

YASKAWA CANopen SI-S3 Technical manual

YASKAWA

YASKAWA CANopen SI-S3 Technical manual

GE D20A6 instructions

GE

GE D20A6 instructions

Danfoss VLT AQUA Drive FC 202 operating manual

Danfoss

Danfoss VLT AQUA Drive FC 202 operating manual

Lenze PositionServo 940 user manual

Lenze

Lenze PositionServo 940 user manual

Unex MC-D-250-1000-050W-TW operating manual

Unex

Unex MC-D-250-1000-050W-TW operating manual

Geckodrive G213V manual

Geckodrive

Geckodrive G213V manual

ABB RSYC-01 user manual

ABB

ABB RSYC-01 user manual

Rockwell Automation PowerFlex 700S Programming manual

Rockwell Automation

Rockwell Automation PowerFlex 700S Programming manual

WEG DeviceNet CFW500 user manual

WEG

WEG DeviceNet CFW500 user manual

Siemens SINAMICS G List manual

Siemens

Siemens SINAMICS G List manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

QUICK SETUP INSTRUCTIONS FOR
VARIABLE SPEED DRIVE
1 PHASE TO 3 PHASE
AND
3 PHASE TO 3 PHASE
HAMILTON PH: 07 847 3374
CHRISTCHURCH PH:03 666 3374
sales@rotatingmachinery.co.nz
VFD-MS300 Series
Instrucons for Remote Setup
(Remote On/O and Speed Variaon)
• For remote stop and start connect between DCM and
MI1 (FWD) and MI2 (REV) (DCM is your common)
• For remote Potenometer connect the potenometer
to +10V, AVI and ACM (common).
• Set 00.20 to 2 (Remote Potenometer seng)
• Set 00.21 to 1 (Remote ON/OFF seng)
• Set 02.00 to 1 or 2 (2-wire operaon control)
Connect Phase (Live) to R and Neutral to S for single
phase supply
Connecon U/T1, V/T2, W/T3 go to the motor
Connect 3 phase input supply L1/R, L2/S, L3/T
Connecon U/T1, V/T2, W/T3 go to the motor
• Set 02.00 to 3 (3-wire operaon control)
AUCKLAND PH: 09 271 6063
info@brookmtl.co.nz
V/F curve set up
(Factory setting is General purpose)
Important Noce
• Wiring and connecon must be carried out by a
registered electrician.
• Connecon by an unqualied person voids the
warranty.
• Please check the suitability of the motor before
aempng to connect it to the device.
• Ensure the motor terminals are congured to
suit supply from VSD, for 1ph supply VFD the
motor must be connected in DELTA. For 3ph
supply VFD please consult the motors name tag
for 400V connecon.
• Display will show ether F, H, A, U aer power up.
• Press the enter buon.
• 00. will appear on the screen, this is the parameter group.
• Use the up and down keys to change parameter group to the
desired one. Press “ENTER”.
• 00.00 will appear on the screen, this is the sub group.
• Use the up and down keys to change parameters selecons to
the desired one. Press “ENTER”
• You will now be able to change the required seng of the pa-
rameter to the desired value or seng. Press “ENTER”. End
will ash on your screen to indicate that your seng has been
saved.
• Connue the above steps ll all of your required parameters
have been set.
• If you need to back out of a sub parameter group you can press
the “MODE” buon.
• Once all the parameters have been set press the “MODE”
buon ll the F50.0 screen comes up again.
List of quick set up parameters
1.Status Display –Display the drives current status
2.LED Display—Indicates frequency, voltage, current, user
dened units
3.Potenometer—For local frequency seng
4.Run Key— to start drive locally
5.UP & DOWN Key—Used to change numerical numbers,
frequency, parameters
6.Mode—Change between dierent display mode
7.STOP/RESET— Stops AC drive operaon and resets the drive
aer a fault has occurred
8.ENTER—Used to enter and save the parameters
See back page for power and remote control connecons
and set up
Quick Setup for Variable Speed Drive
Turn on power to unit and follow as below: • 00.02 All parameters are reset to factory sengs or 50Hz
sengs, set to 9 (must be none aer inial powerup)
• 00.20 Source of master Frequency Command.
0 = UP/DOWN arrow (Factory seng)
2 = External analog input
3 = External UP/DOWN terminals
7 = Digital keypad potenometer
• 00.21 Source of master Operaon Command.
0 = Digital keypad (Factory seng )
1 = External terminals
• 01.00 Change to the maximum Frequency required
• 01.01 Change value to match Hz on motor nameplate
• 01.02 Change to match voltage on motor nameplate (Max
Voltage output)
• 01.10 Upper limit Frequency
• 01.11 Lower limit Frequency
• 01.12 Acceleraon me (factory seng 10sec)
• 01.13 Deceleraon me (factory seng 10sec)
• 05.01 Set to Motor Name Plate Current
• 05.02 Set to Motor Name Plate kW
• 05.03 Set to Motor Name Plate Speed (rpm)
• 05.04 Set as the number of poles of the motor
(3000rpm=2pole; 1500rpm=4pole;1000rpm=6pole;
750rpm=8pole) (factory seng 4 pole)
• 05.00 Auto tuning, opon 1 Dynamic test for inducon
motor = 1 (note motor must be unloaded), Stac test for
inducon motor = 2, aer the parameter number is
entered press “MODE” buon to return to main screen
showing “F30.00 or F33.33”, press the “RUN” buon to
start auto tune, Auto tuning should only be preformed
aer all the data is entered.
• 06.13 Electronic thermal relay.
0 = Inverter motor (with external forced cooling ed)
1 = Standard motor (motor with fan on sha)
2 = Disable (factory seng)