EMGA Ebro TFX Series User manual

926.001 DIGITAL THERMOMETER - MANUAL
926001 en ma 2013
Thermometer
TFX Serie

926001 en ma 2013
TFX Serie
2
English
Dear customer,
Congratulations on the purchase of an
ebro product.
We hope than you can make use of this
product for a long time and that it helps
you with your work.
Information that are useful and impor-
tant for understanding the function are
highlighted in the instructions text.
Standards:
cate
rms that this product ful
lls CE guidelines.
ed by NSF
(exept TFX 430)
ed by UL
This product fullls the guidelines in
accordance with EN 13485.
Suitability:
S (Storage), T (Transport)
Location:
A (Food storage and distribution sy-
stems) and E (Transportable thermo-
meter)
cation:
1 for measurement of the air tempera-
ture and 0.5 for the measurement of the
internal product temperature.
Measurement range:
- TFX 410 -50 ... +300°C
- TFX 420 -50 ... +400°C
- TFX 430 -100 ... +500°C
In accordance with EN 13485, this device is subject to
regular (yearly) inspections as per EN 13486.

926001 en ma 2013
TFX Serie
English
Table of contents
1 Introduction ...............................................
1.1 General.....................................................
1.2 Safety instructions ...............................
1.3 Precautions.............................................
2 Scope of Delivery......................................
3 Description ................................................
3.1 General....................................................
3.2 User menu..............................................
guration options......................
3.2.2 Menu operation..................................
4 Operation .................................................. 1
4.1 Switching on thermometer ............1
4.2 Display.....................................................1
4.3 Measuring temperature....................1
4.4 Measurement memory......................2
4.4.1 Retrieving memory contents.........2
4.4.2 Storing current value........................2
4.4.3 Deleting measurement memory..2
5 Changing sensor.....................................
6 What do I do if..........................................
7 Calibration servicing .............................
8 Servicing and waste disposal.............
8.1 Cleaning..................................................
8.2 Waste disposal......................................
8.3 Replacing the battery ........................1
9 Appendix.............................................
I Accessories ............................................
II Technical information........................
CE Declararion

926001 en ma 2013
English
1 Introduction
1.1 General
Please read these operating instructions
carefully before using your new precision
thermometer.
These instructions guide you through
working with the thermometer with clear
and simple directions.
Any information which is useful or
relevant in the understanding of the
functionality is headlined as such in the
instructions.
To ensure safe operation of the thermo-
meter, follow all those safety instructions
as indicated by the symbol.
1.2 Safety notes
tNever expose the device to high tem
peratures (> 60°C / 140°F)!
tUnder no circumstances measure live components
with this device and external sensors
tDo not use the device in explosion endangered
areas!
tThe instrument should only be operated within the
ed in the Technical data.
tThe instrument should only be opened if expressly
described in the instruction manual for maintenance
purposes.
tForce should never be applied.
tPlease dispose exhausted batte-
ries according environment regulations.
tDo not put into trash-bin.
tYou can return the instrument directly to us at the
end of its service life. We shall recycle it according rules.
Warranty 2 years
TFX Serie
4

926001 en ma 2013
TFX Serie
English
2 Extent of supply
Check contents of the packing for com-
pleteness and integrity.
If you discover any damage or have any
reason for complaint, please contact
your distributor or:
ebro Electronic GmbH
Peringerstr. 10
85055 Ingolstadt
Tel.: (0841) 9 54 78–0
Fax: (0841) 9 54 78 80
E-mail: info@ebro.de
Internet: http://www.ebro.de
Parts list:
Thermometer with:
tSensor
cate
tInstruction manual
tFor accessories see appendix I
1.3 Cautions
The thermometer TFX should be protec-
ted from the following:
zElectro Static Discharge
z“Thermal shock”
caused by large or abrupt ambient
temperature changes — allow 30 mi-
nutes for unit to stabilize before use
when exposed to “thermal shock”.
zDo not leave the unit on or near
objects of high temperature.

926001 en ma 2013
TFX Serie
Serie 410
Serie 420 / 430
English
3 Description
3.1 General
Powered by a replaceable lithium batte-
ry, the precision thermometer is a handy,
watertight temperature measurement
device for a whole range of measure-
ment and control applications in the
laboratory and in industry.
A micro-processor controls the electro-
nics, guaranteeing maximum measu-
rement precision and linearity over the
entire measurement range.
You may attach a range of ebro sensors
to the thermometer TFX 410-1 and TFX
430, selecting the one most suitable for
your technical measurement application.
With the TFX 410 the probe is rmly
attached.
Serie 410:
1.................Display (LCD)
2.................Key ON/OFF
3.................Key required only for the user
menu
4.................Key required only for the user
menu
5.................Key required only for the user
menu
6.................Probe
Serie 420 / 430:
1.................Display (LCD)
2.................Key ON/OFF
3.................Key MIN/MAX / User menu
4.................Key HOLD / User menu
5.................Key CLR / User menu
6.................Probe
1
2
3
4
5
1
2
3
6
4
5
6

926001 en ma 2013
TFX Serie
English
.2 User menu
Follow this procedure to enter congu-
ration mode:
.
2 Press ON/OFF key (2) and keep
depressed. The segment test is dis-
played for approx. 1 second.
3 Release the ON/OFF key (2) as soon
as device model„TFX“ is displayed.
Then keep the lower key depressed
until „USER“, followed by „MENU“ is
displayed.
The device now enters the “USER
MENU”.
guration options
UNIT: active temperature unit,
switchable between °C and °F
SHDWN:a u t o m a tic switch-o
after 2 hours operation.
activated
deactivated

926001 en ma 2013
TFX Serie
English
RATE: Measurement frequency in
seconds, adjustable from 1
second up to 15 seconds.
The value displayed is the pre-
set measurement frequency in
seconds.
Activate automatic switch-o to
extend battery life. Deactivate the
automatic switch-o if prolonged
measurements are required with the
model TFX 420 / 430.
ALARM T u r n a l a r m f u n c t i o n
ON = Alarm function
turned on
OFF = Alarm function
Press centre key =
Turn alarm function
- To leave the «User menu» turn the
AL LO Lower limit value of
desired range
Press centre key =
unblock
Press left/right keys =
increase/decrease
lower limit value
Press centre key =
store lower limit value
and block changes
°C
Serie 430
Serie 430

926001 en ma 2013
TFX Serie
Serie 430
Serie 430
English
3.2.2 Menu operation
- Select the next menu option
with the right key (4).
- Select the previous menu option
with the left key (3).
- Carry out and store the current
menu option with the down key
(5).
- Exit the menu with the ON/OFF
key (2). The device switches
.
AL HI Upper limit value of
desired range
Press centre key =
unblock
Press left/right keys =
increase/decrease up
per limit value
Press centre key =
store upper limit value
and block changes
SCAL Activation/Deactivati-
on of the special ad-
justment
ON = Activated
= Deactivated
Press centre key =
ON/OFF of special ad-
justment
°C

926001 en ma 2013
TFX Serie
1
Serie 410
Serie 420 / 430
English
4 Operation
4.1 Swi tching on thermome-
ter
To switch the thermometer on, keep
key »ON/OFF« (2) pressed for approx.
1 second.
The device performs a system test
rst, displaying all segments used by
this thermometer model for approx. 1
second.
After the automatic test, the thermome-
ter switches to measuring mode and the
rst measurement reading is displayed
in °C. The thermometer is now ready for
use.
If an error message is displayed,
please refer to chapter 6 „What do I
do if ...“.
4.2 Display
All necessary information is displayed
on an LCD (Liquid Crystal Display).
The individual symbols have the following
meanings:
1 = Display for current measured
values
2 = Battery status indicator
3 = Trend display positive
4 = Minus sign (negative measured
values)
5 = Trend display negative
6 = Stored measurement and text
display
1
1
2
2
3
3
4
4
5
5
6

926001 en ma 2013
TFX Serie
English
4.3 Measuring temperature
Select the required unit of measurement,
°C or °F, from the user menu (chapter
3.2).
Position the measuring sensor.
Use the measuring sensor only as
intended so as to eliminate erroneous
measurements.
Wait until the measured value has
stabilised. The trend display shows
a downward pointing triangle for
decreasing (4) temperatures and an
upward-pointing triangle for increasing
(3) temperatures.
The trend display disappears once the
measurement value becomes stable.
Switch the device o with »ON/OFF«
when measurements are complete.
If special adjustment is activated „SCAL“
will be shown in display for a short
while.
Serie 430

926001 en ma 2013
TFX Serie
2
English
4.4 Measurement value (only
type 420 / 430)
The maximum and minimum measu-
rement values are stored during a
measuring. Delete the content of the
measurement value memory before
starting a new measuring.
4.4.1 Retrieving memory con-
tents
Press the »MIN/MAX« key once (3).
„MIN“ is displayed along with the lowest
measurement of the current measu-
ring.
Press the key »MIN/MAX« again. „MAX“
is displayed along with the largest
measurement value in the current
measuring.
Press »MIN/MAX« again to return to the
temperature measurement.
4.4.2 Storing current value
Press key »HOLD« (4). „HOLD“ is dis-
played. The current measurement is
now stored. It is also displayed until the
HOLD function is deactivated by repres-
sing the »HOLD« key.
4.4.3 Deleting measurement
value memory
Press key »CLR« (5). The memory con-
tent is deleted.

926001 en ma 2013
TFX Serie
English
5 Changing sensor
The thermometer has been calibrated
at the factory. Measurement precision
may be impaired erent measu-
rement probe is attached
1. Grab the probe cap (with TFX430, go
to point 2 directly) at the recessed
grip planned for it and turn this 60°
anticlockwise. At the beginning of
the turn a noticeable resistance is
to be overcome. Pull the probe cap
downwards.
Do not pull the at the probe pipe!
2. The probe plug-in connector is
visib le now. Pull out the
sensor downwards by pulling at the
plug-in connector.
Do not turn!
3. Plug in a new probe or extension
cable where required. Ensure
the connection is secure.
The connector must be engaged!
4. Slide the protective cover over the
plug-in connector and turn 60°
clockwise to lock again (not with
TFX430).
erusneotyrassecenyletulosbasisihT
watertightness of the probe plug-in
connector!
60° gegen den Uhrzeigersinn
drehen
turn 60° anticlockwise
tournez 60° anti horloge sage
Fühler-Steckverbindung
Plug-in connector
Connecteur embrochable
Fühler-Steckverbindung nach unten
ziehen
Pull downwards by pulling at the
plug-in connector
Tirez en bas par la traction au con-
necteur embrochable

926001 en ma 2013
TFX Serie
English
6 Trouble shooting
Possible cause Remedy
Measuring range
exceeded
Probe defective
Plugin connection
jack - plug
Consider
measuring range
Call service
Check
connection
plug has to snap
in
Below
measuring range
Short circuit of
sensor
Consider
measuring range
Call service
Disconnected
probe
Broken proben
Connect probe
Change probe

926001 en ma 2013
TFX Serie
English
7 Calibration service
In order to guarantee a high measuring
precision, the thermometer must be
calibrated every year. Therefore ebro
Electronic GmbH & Co. KG oers a
calibration service.
tFill in the enclosed service card.
tAfter one year we will recall your
thermometer for calibration.
tThe calibrated thermometer will be
returned within one week.
8 Servicing and waste
disposal
8.1 Cleaning
Clean the device with a damp cloth. Do
not use any solvents such as Aceton as
they corrode the plastic.
Isopropyl alcohol may be used to dis-
infect.
8.2 Waste disposal
Should the device become unsuitable
for use, it must be disposed of profes-
sionally, such as at recycling centres
that accept electronic scrap.
Never dispose of the device in household
waste.
Please dispose of spent batteries re-
sponsibly.

926001 en ma 2013
TFX Serie
11
22
3
4
5
6
7
English
8.3 Replacing the battery
The battery symbol on the display (Fi-
gure 2 on page 18) indicates that the
battery needs to be replaced.
Battery operational
Battery operational
Battery shortly exhausted
Battery needs to be re-
placed
The thermometer must be opened to
replace the battery.
Remove both plastic plugs (1) with a
sharp implement (needle, etc.).
Using a suitable cross-head screwdriver
(PZ 1), remove both the visible cross-
head screws. (2)
Hold the bottom of the thermometer
(6) in one hand and remove the upper
part with the other hand (5). Pull it out
upwards.
You can now see the battery holder (3)
with battery (4) on the circuit board (7).
Pull the used battery out of the holder in
direction of arrow.
Ensuring ngers are free of grease,
insert the new battery into the holder.
The positive sign on the battery must be
pointing upwards, i.e. visible.

926001 en ma 2013
TFX Serie
English
9 Appendix
I Accessories
er
cial leather
case, long AG120
Portable case AG130
Protective casing AG140
Synthetic material mount AG150
Wall mount, stainless steel AG160
Battery changing set AG170
Silicone extension wire 1.0 m
AX110
Probes in various specs available on
request.
Reassemble the thermometer in reverse
order, noting the correct tightening tor-
que of 0.4 Nm.
To ensure device is fully water-tightness,
make sure the seal between lower and
upper housing is seated correctly in the
groove.
Finally, do not forget to insert both
plastic plugs back into their drill-holes
(slightly chamfered surfaces outward).
Please avoid any electrostatic dischar-
ging during the battery replacement
process.

926001 en ma 2013
English
Subject to technical change
II Technical data
Measuring range
Series 410..................................................... -50 to +300 °C
(-60 to +580 °F)
Series 420..................................................... -50 to +400 °C
(-60 to +760 °F)
Serie 430 ...................................................... -100 to +500 °C
(-150 to +930 °F)
Sensor
Series 410/420 ........................................... Pt 1000
Series 430..................................................... Pt100
Measuring principle
Series 410/420 ........................................... 2 wire technology
Series 430..................................................... 4-wire technology
Operating temperature
Series 410/420 ........................................... -25 to +50 °C
(-13 to +122 °F)
Series 430..................................................... -20 to +50°C
(-4 to +122 °F)
Storage temperature..................................... -30 to +70 °C
(-22 to +158 °F)
Resolution......................................................... 0.1 °C / 0.2 °F
ResolutionTFX430 .......................................... 0,01°C/0,02°F at -100.00 to
+199.99°C (°F) and 0.1 °C /
0.1 °F for the rest.
Measuring precision
Series 410/420 ........................................... ± 0.3 / ±0.3 °F
Series 430..................................................... -50.00 to +199.99°C (°F)
±0.05°C (±0.08°F)
Rest ±0.2°C / ±0.4°F
Measuring interval......................................... 1 to 15 s
Thermal time constant T90
moved water:
Glass probe ................................................ approx. 70 s
other probes..................................................... approx. 8 s
quiescent water:
Glass probe ................................................ approx. 90 s
other probes............................................... approx. 10 s
Battery ................................................................ Lithium coin cell
3 V / 1Ah, type CR 2477
Life time of battery ........................................ lapprox. 5 years
Dimensions (LxWxH)..................................... 109 x 54 x 22 mm
Housing material ............................................ ABS
Safety class........................................................ IP 67
Weight................................................................ approx. 90 g
Maximum altitude..........................................
TFX Serie

926001 en ma 2013
Konformitätserklärung
Conformity declaration
Déclaration de conformité
ebro Electronic GmbH
Peringerstraße 10
D-85055 Ingolstadt
erklärt in alleiniger Verantwortung, dass das Produkt
declares in sole responsibility that the product
déclare sous sa seule responsabilité que le produit
Geräteart:
Type of device:
Type d‘appareil:
Typ:
Type:
Modèle:
auf das sich diese Erklärung bezieht, mit der folgenden Richtlinie
übereinstimmt:
to which this declaration refers, complies with the following guideline:
auquel cette déclaration se réfère, est conforme aux directive
Prüfstellen:
Inspected by:
Organisme de con-
trôle:
Robert Teich
Geschäftsführer
Managing director
Directeur gérant
Richtlinie:
Guideline:
Directive:
SCHWILLE Elektronik
Produktions- u. Vertriebs GmbH
Benzstrasse 1A
85551 Kirchheim
EMV-Richtlinie 2004/108/EG
EMC-Guiedeline 2004/108/EG
CEM-Directive 2004/108/EG
Thermometer
Thermometer
Thermomètre
TFX Serie
Ingolstadt, 03.11.2004
This manual suits for next models
1
Table of contents
Other EMGA Thermometer manuals