manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Empire Comfort Systems
  6. •
  7. Blower
  8. •
  9. Empire Comfort Systems CIB3-2 User manual

Empire Comfort Systems CIB3-2 User manual

Page 1
INSTALLATION INSTRUCTIONS
CAST IRON BLOWER
CIB3-2
FOR USE ON:
HERITAGE CAST IRON STOVES MODELS:
DVP30CA30(B,F,M,S,W)(N,P)
VFP30CA30(B,F,M,S,W)(N,P)
Carton Contents
Blower Assembly
Auto/On/Off Switch
Fan Control Bracket Assembly
Wire Channel - Left DV
Wire Channel - Left VF
Hardware Package
(2) 10 x 1/2” Screw
(1) On/Off/Auto Switch
(1) Rheostat Nut
(1) Knob, Rheostat
Hardware Package
CAUTION: Sharp edges, use protective gloves when
installing.
GAS-FIRED
LEAVE THIS MANUAL WITH THE OWNER FOR FUTURE REFERENCE.
NUT
KNOB
#10x1/2” SCREW
AUTO/ON/OFF SWITCH
25744-2-0610Page 2
Installing Optional CIB3 Blower
1. Loosen, but do not remove, four (4) hex-head screws located
on the exterior, bottom of the appliance.
2. Position the blower assembly at the rear of the appliance. The
blower assembly has four (4) keyholes for attachment to the
exterior, bottom of the appliance.
3. Place the large diameter holes in the keyholes over and behind
the four (4) hex-head screws that were loosened in Step 1.
Push inward on the blower assembly to lock the keyholes into
position behind the screws. Tighten four (4) hex-head screws to
secure blower assembly to exterior, bottom of the appliance.
4. Remove wire channel-left from appliance by removing (2)
10 x 1/2" screws on left side of the appliance. Note: Some
units require a new wire channel. If Rheostat mounting holes
are missing from part removed from unit, discard wire channel
removed from unit and continue installation with appropriate
wire channel shipped with blower. See Figure 1.
5. Route fan control wires through rectangular notch on wire
channel - left.
6. Attach 1/4" push-on terminal from blue wire on the fan control
to the AUTO (top) tab on the switch.
7. Attach 1/4" push-on terminal from black wire to the OFF
(middle) tab on the switch.
8. Attach 1/4" push-on terminal from white wire on the fan control
to the ON (bottom) tab on the switch.
9. Insert AUTO/OFF/ON switch into rectangular notch on wire
channel - left.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Figure 1
10. Install rheostat through hole in wire channel and align small
tab with small hole.
11. Use an 11/16” wrench to tighten rheostat nut on stationary
portion of knob stem of the rheostat. Note: Nut is self-tapping
and can be started at an angle.
12. Push rheostat knob onto knob stem until fully seated.
13. Bend the fan control tab, located on the left side of the back
of the unit, inward toward the unit. See Figure 1. Be sure tab
is bent at least 90 degrees to allow fan control bracket to slide
into slot.
14. Attach fan control with bracket onto rear cover with
two (2) 10 x 1/2" screws provided in hardware package.
15. Route wires from fan control and ON/OFF/REMOTE switch
within wire channel.
16. Attach wire channel to channel divider with two (2) 10 x 1/2"
screws from Step 4.
17. Installation of optional CIB3 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type The fan control
will require between 5 and 10 minutes of main burner operation
before the fan control "closes" and activates the blower. The blower
will continue to run between 5 and 10 minutes after the main
burner shuts off, before the fan control "opens" and deactivates
the blower.
AUTO/OFF/ON SWITCH
BLOWER ASSEMBLY
FAN CONTROL
RHEOSTAT
KNOB
NUT
WIRE CHANNEL - LEFT
WIRE CHANNEL -LEFT
(VF) MODELS (DV) MODELS
FAN CONTROL TAB
25744-2-0610 Page 3
CAUTION: Labelallwirespriorto disconnection whenservicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Cleaning
The blower wheel will collect lint and could require cleaning once
a year. If the air output decreases or the noise level increases, it
indicates a dirty wheel.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to
oil blower motor.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code,ANSI/NFPA70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off: Turn temperature dial or
thermostat to lowest setting. Turn knob on gas control to
"OFF," depressing slightly. Do not force.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Figure 2
25744-2-0610Page 4
EMPIRE
EMPIRE
Comfor t Systems
Empire Comfort Systems Inc.
918 Freeburg Ave. Belleville, IL 62220
If you have a general question about our products, please e-mail us at
[email protected].
If you have a service or repair question, please contact your dealer.
www.empirecomfort.com
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
1
2
3
5
6
7
8
9
10
11
4
12
13
14
15
PARTS LIST
INDEX
NUMBER
PART
NUMBER
DESCRIPTION
1 R-1454 BRASS BUSHING
2 R-1499 RUBBER GROMMET
3 24231 BLOWER HOUSING
4 R-1410 STRAIN RELIEF BUSHING
5 R-9927 BLOWER ASSEMBLY
6 24225 BLOWER COVER
7 R-6159 CORD SET
8 R-10363 WIRE HARNESS
9 R-2503 FAN CONTROL
10 24222 FAN CONTROL BRACKET
11 R-2805 AUTO OFF/ON SWITCH
12 R-4192 RHEOSTAT KNOB
13 18879 RHEOSTAT
14 26050 WIRE CHANNEL - LEFT, DV
15 26052 WIRE CHANNEL - LEFT, VF
Parts Not Under Warranty
Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu-
tors list. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the
service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is required for
warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts, rst obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list. Be sure to give all this information . . .
Appliance Number Part Description
Appliance Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, res and all causes beyond our control.
HOW TO ORDER REPAIR PARTS

Other Empire Comfort Systems Blower manuals

Empire Comfort Systems FBB4 User manual

Empire Comfort Systems

Empire Comfort Systems FBB4 User manual

Empire Comfort Systems RH-50 User manual

Empire Comfort Systems

Empire Comfort Systems RH-50 User manual

Empire Comfort Systems FBB21 User manual

Empire Comfort Systems

Empire Comfort Systems FBB21 User manual

Empire Comfort Systems FBB9-1 User manual

Empire Comfort Systems

Empire Comfort Systems FBB9-1 User manual

Empire Comfort Systems FBB21 User manual

Empire Comfort Systems

Empire Comfort Systems FBB21 User manual

Empire Comfort Systems FBB5-1 User manual

Empire Comfort Systems

Empire Comfort Systems FBB5-1 User manual

Popular Blower manuals by other brands

Ebmpapst D2E146-KA45-01 operating instructions

Ebmpapst

Ebmpapst D2E146-KA45-01 operating instructions

HAKO Sweepmaster M600 instruction manual

HAKO

HAKO Sweepmaster M600 instruction manual

Cramer 2400186 Operator's manual

Cramer

Cramer 2400186 Operator's manual

Craftsman 151.30382 operating manual

Craftsman

Craftsman 151.30382 operating manual

GARDTECH GT10007/GY8900 manual

GARDTECH

GARDTECH GT10007/GY8900 manual

Mowox DYM500301 Original instructions

Mowox

Mowox DYM500301 Original instructions

Craftsman 316.79497 Operator's manual

Craftsman

Craftsman 316.79497 Operator's manual

Homelite ut09526 Operator's manual

Homelite

Homelite ut09526 Operator's manual

Zenoah STRATO-CHARGED EBZ4800 parts list

Zenoah

Zenoah STRATO-CHARGED EBZ4800 parts list

Weed Eater BV2000LE series instruction manual

Weed Eater

Weed Eater BV2000LE series instruction manual

STEWART-AMOS Starfire S-5s Operation manual

STEWART-AMOS

STEWART-AMOS Starfire S-5s Operation manual

Sweepster WSP36 series Operator and parts manual

Sweepster

Sweepster WSP36 series Operator and parts manual

Nilfisk-Advance SR 1000S P user manual

Nilfisk-Advance

Nilfisk-Advance SR 1000S P user manual

Birchmeier AS 1200 AC1 Instructions for use

Birchmeier

Birchmeier AS 1200 AC1 Instructions for use

Stihl BR 800 instruction manual

Stihl

Stihl BR 800 instruction manual

stayer VENTO 2400 B operating instructions

stayer

stayer VENTO 2400 B operating instructions

Stihl BR 200 instruction manual

Stihl

Stihl BR 200 instruction manual

Tennant S5 NA Operator and parts manual

Tennant

Tennant S5 NA Operator and parts manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.