37001-3-1116 Page 1Empire Comfort Systems Inc. • Belleville, IL
Bench Installation
1. Remove Blower Access Panels (Figure 1).
Figure 1
2. Place Blower onto blower brackets. (Figure 2)
Figure 2
3. Hand bend tab as shown in (Figure 3) and secure with
(2) screws.
HAND BEND
TAB INWARD
HAND BEND
TAB INWARD
Figure 3
4. Remove protective connectors on Wire Assembly from
replace and discard. Connect Wire Harness to both blowers
and the other end to the Wire Assembly supplied with the
replace. (Figure 4)
TO WIRE ASSEMBLY
(MODULE)
Figure 4
5. Replace Blower Access Panels removed in step 1. (Figure 1)
Installation After Placement of Unit in Wall
1. Remove the following items (Figure 5).
• Screen barrier (See Homeowner’s Manual, Maintenance
and Service).
• Glass Frame Assembly (See Homeowner’s Manual,
Maintenance and Service).
• Liners (See separate liner instruction document).
Figure 5
2. Remove front and rear burner (Figure 6).
Figure 6
GAS-FIRED
CAUTION: Sharp edges. Use protective gloves when installing.
INSTALLATION INSTRUCTIONS
FBB21 BLOWER, AUTO VARIABLE-SPEED-TWIN
FOR USE ON DVCT(36,40) SERIES FIREPLACES