Empire DV-210-10SG Quick start guide

DIRECT VENT
WALL FURNACE
MODELS
DV-210-10SG
DV-215-10SG
This appliance may be installed in an after-market,
permanently located, manufactured home (USA only),
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied
kit is used.
INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
WARNING: If not installed, operated, and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions
are not followed exactly, a re or explosion may
result causing property damage, personal injury or
loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
re department.
— Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
Page 1

32193-3-0514Page 2
TABLE OF CONTENTS
Important Safety Information ............................................................................................................ 3
Safety Information for Users of LP Gas............................................................................................ 4
Requirements for Massachusetts..................................................................................................... 5
Introduction....................................................................................................................................... 6
Specications ................................................................................................................................... 6
Gas Supply....................................................................................................................................... 7
Clearances ...................................................................................................................................... 8
Installation Instructions..................................................................................................................8-9
Optional Thermostat Location ........................................................................................................ 10
Lighting Instructions ....................................................................................................................... 11
Pilot Flame Characteristics ............................................................................................................ 12
Main Burner Flame Characteristics ............................................................................................... 12
Maintenance................................................................................................................................... 12
Troubleshooting.............................................................................................................................. 13
Parts List ........................................................................................................................................ 14
Parts View ...................................................................................................................................... 15
Optional Blower Installation Instructions ...................................................................................16-17
Master Parts Distributor List ........................................................................................................... 18
How to Order Repair Parts ............................................................................................................. 18
Warranty ......................................................................................................................................... 19
SECTION PAGE

32193-3-0514 Page 3
• Due to high temperatures the appliance should be
located out of trafc and away from furniture and
draperies.
• Children and adults should be alerted to the hazards
of high surface temperatures and should stay away
to avoid burns or clothing ignition.
• Young children should be carefully supervised when
they are in the same room as the appliance.
• Clothing or other ammable material should not be
placed on or near the appliance.
• Any safety screen or guard removed for servicing
an appliance must be replaced prior to operating the
appliance.
• Keep burner and control compartment clean.
• Vent cap hot while furnace is in operation.
• Installation and repair should be done by a QUALI-
FIED SERVICE PERSON. The appliance should
be inspected before use and at least annually by a
qualied service person.
• More frequent cleaning may be required due to ex-
cessive lint from carpeting, bedding materials, etc.
It is imperative that control compartments, burners,
and circulating air passageways of the appliance be
kept clean.
• DO NOT put anything around the furnace that will
obstruct the ow of combustion and ventilation air.
• DO keep the appliance area clear and free from
combustible material, gasoline, and other ammable
vapors and liquids.
• DO examine venting system periodically and replace
damaged parts.
• DO examine burners periodically. Clean and replace
damaged parts.
• CAUTION: Pilot hole cover must be kept tightly
closed during operation.
• DO NOT use this heater if any part has been under
water. Immediately call a qualied service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
IMPORTANT SAFETY INFORMATION

32193-3-0514Page 4
SAFETY INFORMATION FOR USERS OF LP-GAS
Propane (LP-Gas) is a ammable gas which can cause res
and explosions. In its natural state, propane is odorless and
colorless. You may not know all the following safety precau-
tions which can protect both you and your family from an ac-
cident. Read them carefully now, then review them point by
point with the members of your household. Someday when
there may not be a minute to lose, everyone's safety will depend
on knowing exactly what to do. If, after reading the following
information, you feel you still need more information, please
contact your gas supplier.
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas
because of the odorant put in the LP-Gas.
That's your signal to go into immediate action!
• Do not operate electric switches, light matches, use your phone.
Do not do anything that could ignite the gas.
• Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.
• Close all gas tank or cylinder supply valves.
• LP-Gas is heavier than air and may settle in low areas such
as basements. When you have reason to suspect a gas leak,
keep out of basements and other low areas. Stay out until
reghters declare them to be safe.
• Use your neighbor's phone and call a trained LP-Gas service
person and the re department. Even though you may not
continue to smell gas, do not turn on the gas again. Do not
re-enter the building, vehicle, trailer, or area.
• Finally, let the service man and reghters check for escaped
gas. Have them air out the area before you return. Properly
trained LP-Gas service people should repair the leak, then
check and relight the gas appliance for you.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must nd out if you can
smell the odorant in propane. Smoking can decrease your ability to
smell. Being around an odor for a time can affect your sensitivity or
ability to detect that odor. Sometimes other odors in the area mask
the gas odor. People may not smell the gas odor or their minds are
on something else. Thinking about smelling a gas odor can make
it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some
circumstances. For example, if there is an underground leak, the
movement of the gas through soil can lter the odorant. Odorants in
LP-Gas also are subject to oxidation. This fading can occur if there
is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That will
take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could
vary at different levels. Since it is heavier than air, there may be
more odor at lower levels. Always be sensitive to the slightest gas
odor. If you detect any odor, treat it as a serious leak. Immediately
go into action as instructed earlier.
SOME POINTS TO REMEMBER
• Learn to recognize the odor of LP-gas. Your local LP-Gas
Dealer can give you a "Scratch and Sniff" pamphlet. Use it to
nd out what the propane odor smells like. If you suspect that
your LP-Gas has a weak or abnormal odor, call your LP-Gas
Dealer.
• If you are not qualied, do not light pilot lights, perform service,
or make adjustments to appliances on the LP-Gas system. If
you are qualied, consciously think about the odor of LP-Gas
prior to and while lighting pilot lights or performing service or
making adjustments.
• Sometimes a basement or a closed-up house has a musty
smell that can cover up the LP-Gas odor. Do not try to light
pilot lights, perform service, or make adjustments in an area
where the conditions are such that you may not detect the odor
if there has been a leak of LP-Gas.
• Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people should
be particularly alert and careful when new tanks or cylinders
are placed in service. Odor fade can occur in new tanks, or
reinstalled old tanks, if they are lled and allowed to set too
long before relling. Cylinders and tanks which have been out
of service for a time may develop internal rust which will cause
odor fade. If such conditions are suspected to exist, a periodic
sniff test of the gas is advisable. If you have any question about
the gas odor, call your LP-gas dealer. Aperiodic sniff test of the
LP-gas is a good safety measure under any condition.
• If, at any time, you do not smell the LP-Gas odorant and you
think you should, assume you have a leak. Then take the same
immediate action recommended above for the occasion when
you do detect the odorized LP-Gas.
• If you experience a complete "gas out," (the container is under
no vapor pressure), turn the tank valve off immediately. If the
container valve is left on, the container may draw in some air
through openings such as pilot light orices. If this occurs, some
new internal rusting could occur. If the valve is left open, then
treat the container as a new tank. Always be sure your con-
tainer is under vapor pressure by turning it off at the container
before it goes completely empty or having it relled before it is
completely empty.

32193-3-0514 Page 5
REQUIREMENTS FOR MASSACHUSETTS
For all side wall horizontally vented gas fueled equipment installed
in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the
Commonwealth and where the side wall exhaust vent termination
is less than seven (7) feet above nished grade in the area of the
venting, including but not limited to decks and porches, the following
requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At
the time of installation of the side wall horizontal vented gas fu-
eled equipment, the installing plumber or gastter shall observe
that a hard wired carbon monoxide detector with an alarm and
battery back-up is installed on the oor level where the gas
equipment is to be installed. In addition, the installing plumber
or gastter shall observe that a battery operated or hard wired
carbon monoxide detector with an alarm is installed on each
additional level of the dwelling, building or structure served by
the side wall horizontal vented gas fueled equipment. It shall be
the responsibility of the property owner to secure the services
of qualied licensed professionals for the installation of hard
wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent oor
level.
b. In the event that the requirements of this subdivision can not
be met at the time of completion of installation, the owner
shall have a period of thirty (30) days to comply with the
above requirements; provided, however, that during said
thirty (30) day period, a battery operated carbon monoxide
detector with an alarm shall be installed.
2. APPROVED CARBONMONOXIDE DETECTORS.Each carbon
monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034
listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be per-
manently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled
heating appliance or equipment. The sign shall read, in print
size no less than one-half (1/2) inch in size, “GAS VENT DI-
RECTLY BELOW. KEEP CLEAR OFALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall
horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes
carbon monoxide detectors and signage installed in accordance
with the provisions of 248 CMR 5.08(2)(a) 1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from
248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled “Equip-
ment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure
separate from the dwelling, building or structure used
in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT
VENTING SYSTEM PROVIDED. When the manufacturer of
Product Approved side wall horizontally vented gas equip-
ment provides a venting system design or venting system
components with the equipment, the instructions provided
by the manufacturer for installation of the equipment and
the venting system shall include:
1. Detailed instructions for the installation of the venting
system design or the venting system components; and
2. A complete parts list for the venting system design or
venting system.
(e) Acopy of all installation instructions for all ProductApproved
side wall horizontally vented gas fueled equipment, all
venting instructions, all parts lists for venting instructions,
and/or all venting design instructions shall remain with the
appliance or equipment at the completion of the installation.

32193-3-0514Page 6
Model DV-210 DV-215
Input BTU/HR (KW/H) 10,000 (2.9) 15,000 (4.4)
Height 21 3/8" (543mm) 24 7/8" (632mm)
Width 16 1/4 (413mm) 20 1/4" (514mm)
Depth 9 3/8" (239mm) 9 3/8" (239mm)
Gas Inlet 1/2" (13mm) 1/2" (13mm)
Options for Above Furnaces
Blower DVB-1 DVB-1
Vinyl Siding Vent Kit DV-822 DV-822
INTRODUCTION
SPECIFICATIONS
Introduction
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of a direct vent
wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner ll out and mail warranty card supplied
with furnace.
3. Installer should show owner how to start and operate furnace
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous. This
is a heating appliance and any panel, door or guard removed for
servicing an appliance must be replaced prior to operating the
appliance.
To Conserve Gas: Turn off pilot when heater is not in use.
General Information
This furnace is design certied in accordance with American National
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association, as a Gravity Direct Vent Wall Furnace to be
installed on an outside wall according to these instructions.
Any alteration of the original design, installed other than as shown
in these instructions or use with a type of gas not shown on the
rating plate is the responsibility of the person and company making
the change.
Important
All correspondence should refer to complete Model No., Serial No.
and type of gas.
Notice: During initial ring of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" (457mm) above the oor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualied agency. The term "qualied agency"
means any individual, rm, corporation or company which either in
person or through a representative is engaged in and is responsible for
(a) the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made
by a licensed plumber or gas tter in the Commonwealth of
Massachusetts.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m) , input ratings
should be reduced at the rate of 4 percent for each 1,000 feet (305m)
above sea level. Canadian High Altitudes for locations having an
elevation above mean sea level between 2,000 feet (610m) and
4,500 feet (1370m), the manifold pressure is to be decreased from
4.0" w.c. (.996kPa) to 3.2" w.c. (.797kPa) for Natural Gas and from
10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa) for Propane Gas.
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or other
combustible material, other than wood ooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the re-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that may discolor.

32193-3-0514 Page 7
GAS SUPPLY
Locating Gas Supply
The gas line can enter the unit either through the oor or outside
wall. The gas line opening should be made at this time. Location
of the opening will be determined by the position of oor joists and
the valve and union used for servicing.
Recommended Gas Pipe Diameter
Pipe Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Nat. L.P. Nat. L.P.
0-10 feet
0-3 meters
1/2”
12.7 mm
3/8”
9.5mm
1/2”
12.7 mm
3/8”
9.5 mm
10-40 feet
4-12 meters
1/2”
12.7 mm
1/2”
12.7mm
5/8”
15.9 mm
1/2”
12.7 mm
40-100 feet
13-30 meters
1/2”
12.7 mm
1/2”
12.7mm
3/4”
19 mm
1/2”
12.7 mm
100-150 feet
31-46 meters
3/4”
19 mm
1/2”
12.7 mm
7/8”
22.2 mm
3/4”
19 mm
Note: Never use plastic pipe. Check to conrm whether your local
codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24Appliance Connectors of Corrugated Metal Tubing
and Fittings
— ANS Z21.45Assembled FlexibleAppliance Connectors of Other
Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction. The state of Massachusetts requires that a
exible appliance connector cannot exceed three feet in length.
NPT NIPPLE
Figure 1
Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/
CGA-B149 (.1 or .2) installation code.
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the unit.
Where none exists, or where its size or location is not adequate,
contact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant
to the action of liqueed petroleum gases. The gas lines must be
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made.
Never use an exposed ame to check for leaks. Appliance must be
disconnected from piping at inlet of control valve and pipe capped
or plugged for pressure test. Never pressure test with appliance
connected; control valve will sustain damage!
A gas valve and ground joint union should be installed in the gas
line upstream of the gas control to aid in servicing. It is required by
the National Fuel Gas Code that a drip line be installed near the gas
inlet. This should consist of a vertical length of pipe tee connected
into the gas line that is capped on the bottom in which condensation
and foreign particles may collect.
Figure 2
Method of Installing a Tee Fitting Sediment Trap
Pressure Testing of the Gas Supply System
1. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T.
plugged tapping, accessible for test gauge connection, must be
placed immediately upstream of the gas supply connection to
the appliance.
2. The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).
3. The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal
to or less than 1/2 psig (3.5 kPa).
Attention! If one of the above procedures results in pressures in
excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve,
it will result in a hazardous condition.
Checking Manifold Pressure
Both Propane and Natural gas valves have a built-in pressure
regulator in the gas valve. Natural gas models will have a manifold
pressure of approximately 4.0" w.c. (.996kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 5.0" w.c.
(1.245kPa) for the purpose of input adjustment to a maximum of
10.5" w.c. (2.61kPa). Propane gas models will have a manifold
pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 11.0" w.c.
(2.739kPa) for the purpose of input adjustment to a maximum of
13.0" w.c. (3.237kPa).
A 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge
connection, is located on the outlet side of the gas control.

32193-3-0514Page 8
The furnace is to be located on an outside wall. Locate wall studs
so that wall opening will be located between wall studs. One wall
stud can be used for attachment of inside wall plate. The wall
opening required as shown in Figure 3 is a minimum diameter
of 6 1/4 (159mm) inches. The inside wall plate and the outside
wall plate are large enough to permit a wall opening diameter of 8
inches (203mm).
A template is provided in furnace carton for positioning furnace on
the wall. Also, refer to Figure 3 for positioning the furnace on wall
and for locating gas line connection.
Figure 3
Installing Inside Wall Plate
After the wall opening has been located and cut, center and level
inside wall plate in wall opening. The collar on the inside wall
plate is to be placed within the wall opening. On solid wall or wall
stud, attach inside wall plate with (6) #10 x 1 1/2" (38mm) screws
provided. On sheet rock wall, by using wall opening for access,
attach inside wall plate with (6) #10 x 1 1/2" (38mm) screws and
(6) Tinnerman nuts provided.
Attaching Furnace To Inside Wall Plate
Align and attach mounting clips on furnace back with mounting slots
on inside wall plate. The furnace support bracket located at furnace
bottom is to be secured to wall. On solid wall, secure furnace support
bracket with (1) #10 x 1 1/2" (38mm) screw provided. On sheet rock
wall, secure furnace support bracket with (1) toggle bolt provided.
(64mm)
(13mm)
Figure 4
CLEARANCES
INSTALLATION INSTRUCTIONS
1. In selecting a location for installation, it is necessary to provide
adequate accessibility clearances for servicing and proper
installation.
2. Although certied for 0 clearance to the oor , the unit is held in
place by a wall bracket. Enough clearance [2" (51mm) suggested]
to allow changing or adding oor covering is recommended.
Other clearances to combustible construction:
Sides 1" (25mm) and 12" (305mm) from the top.
3. Note the position of the vent relative to the center of the unit.
The DV-210 has the vent in the center. The DV-215 vent is 2"
(51mm) off center to the right.
4. The minimum distance from the center of the outside vent to
the nearest outside corner or obstruction is 16" (406mm).
5. The DV-210/DV-215 minimum wall depth is 4 1/2" (114mm)
and maximum wall depth is 13" (330mm). The use of tubes not
supplied by the manufacturer result in unsatisfactory performance.
The vent terminal of a direct vent appliance, with an input of 10,000
Btu per hour (3 kW) or less shall be located at least 6" (150mm)
from any air opening into a building, and such an appliance with an
input over 10,000 Btu per hour (3 kW) but not over 50,000 Btu per
hour (14.7 kW) shall be installed with a 9" (229mm) vent terminal
clearance and the bottom of the vent terminal and the air intake
shall be located at least 12" (305mm) above grade.
WARNING: The nearest point of the vent cap should be a minimum
horizontal distant of six (6) feet (1.8m) from any pressure regulator.
In case of regulator malfunction, the six feet (1.8m) distance will
reduce the chance of gas entering the vent cap.

32193-3-0514 Page 9
INSTALLATION INSTRUCTIONS (continued)
Cutting Vent Tubes
This is the most important part of the installation. With the furnace
installed on wall the 5" (127mm) diameter air inlet tube and 3"
(76mm) diameter ue outlet tube are to be marked and cut using
the following procedure.
1. Attach 5" (127mm) diameter air inlet tube onto the collar of air drop
assembly. Be sure 5" (127mm) diameter air inlet tube is placed
as far as possible onto the collar of the air drop assembly. Mark
the 5" (127mm) diameter air inlet tube 1/2" (13mm) beyond the
outside wall. Remove 5" (127mm) diameter air inlet tube from
collar of air drop assembly.
2. Attach 3" (76mm) diameter ue outlet tube onto ue outlet collar
on combustion chamber. Be sure 3" (76mm) diameter ue outlet
tube is placed as far as possible onto the collar of ue outlet.
Mark the 3" (76mm) diameter ue outlet tube 2" (51mm) beyond
the outside wall. Remove 3" (76mm) diameter ue outlet tube
from collar of ue outlet on combustion chamber.
3. Mark or wrap tape completely around the tubes at the marked
points to help in making a true cut. Do not crimp or enlarge tubes.
Installing The Vent Assembly
1. Place caulking (not provided) beneath the edge of the outside
wall plate. Use additional caulking to correct uneven wall surface,
such as clapboard.
2. Attach 5" (127mm) diameter air inlet tube onto the collar of air
drop assembly. Attach caulked, outside wall plate into the 5"
(127mm) diameter air inlet tube. Position the outside wall plate
so that 5" (127mm) diameter air inlet tube has a slight downward
slope to the outside. The downward slope is necessary to prevent
the entry of rainwater. Attach outside wall plate to exterior wall
with (4) #10 x 1 1/2" (38mm) screws provided.
3. Apply furnace cement to 3" (76mm) diameter ue outlet collar
on combustion chamber and to 3" (76mm) diameter collar on
vent cap. Attach 3" (76mm) diameter ue outlet tube onto ue
outlet collar on combustion chamber. Attach vent cap into the
3" (76mm) diameter ue outlet tube. Attach vent cap to outside
wall plate with (3) #10 x 1/2" (13mm) screws provided.
4. Installation is completed.
Reassembly And Resealing Vent-Air Intake System
When vent-air intake system is removed for servicing the furnace,
the following steps will assure proper reassembly and resealing of
the vent-air intake assembly.
1. Remove old furnace cement from ue outlet collar on combustion
chamber and collar of vent cap. Remove old furnace cement
from both ends of 3" (76mm) diameter ue outlet tube.
2. Remove old caulking beneath the edge of the outside wall plate.
Apply new caulking beneath the edge of the outside wall plate.
Use additional caulking to correct uneven wall surface, such as
clapboard.
3. Attach 5" (127mm) diameter air inlet tube onto the collar of air
drop assembly. Attach caulked, outside wall plate into the 5"
(127mm) diameter air inlet tube. Position the outside wall plate
so that 5" (127mm) diameter air inlet tube has a slight downward
slope to the outside. The downward slope is necessary to prevent
the entry of rainwater. Attach outside wall plate to exterior wall
with (4) #10 x 1" (25mm) screws provided.
4. Apply furnace cement to 3" (76mm) diameter ue outlet collar
on combustion chamber and to 3" (76mm) diameter collar on
vent cap. Attach 3" (76mm) diameter ue outlet tube onto ue
outlet collar on combustion chamber. Attach vent cap into the
3" (76mm) diameter ue outlet tube. Attach vent cap to outside
wall plate with (3) #10 x 1/2" (13mm) screws provided.
5. Reassembly and resealing vent-air intake system is completed.
Installing a Vent Near a Window Ledge, Other Type of Projection
or on Siding (vinyl, aluminum, etc.)
Direct vent furnaces are designed to be installed on a uniform
outside wall. When the wind comes from any angle (up, down or
from either side), it must hit the vent cap equally over both the air
inlet and the ue outlet portions of the vent. Any wall projection,
such as a door or window casing, which disturbs the wind on one
side of the air inlet section will result in back pressure on the ue
section smothering the ame and eventual pilot outage.
When the vent cap is to be installed on siding or it appears that a
projection within 6" (152mm) of any side of the air inlet section could
shield the air inlet section, the entire vent should be supported away
from the wall at least the distance of the projection. 2" x 4" (51mm
x 102mm) framing whose outside dimensions match the overall
dimensions of the mounting plate is recommended. The 2" x 4"
(51mm x 102mm) framing protects siding from possible warpage
or discoloration. All joints can then be sealed and painted. The wall
depth plus the additional depth of the 2" x 4" (51mm x 102mm)
framing should not exceed a total depth of 13" (330mm) for DV-210/
DV-215. (See Figure 5)
(51mmx102mm)
Figure 5
Figure 5a
Vinylsidingventkit, DV-822,isavailable fromEmpireComfortSystems,
Inc. The depth is 3" (76mm), which enables the vent cap to be extended
away from siding or projections. The wall depth plus the additional 3"
(76mm) depth of the vinyl siding vent cap extension should not exceed
a total depth of 13" (330mm) for DV-210/DV-215. (See Figure 5a)
Warning: When vinyl siding vent kit, DV-822 or 2" x 4" (51mm x
102mm) framing is added to an existing installation (furnace is
installed) do not attempt to add sections of pipe to the ue outlet
tube or air inlet tube. An air tight seal is required for both tubes.
Refer to Parts List, page 14 to order tubes.

32193-3-0514Page 10
These heating thermostats are specially designed for use on self-
generating systems. They should never be used on line or low
voltage A.C. circuits.
Exterior Wall — The thermostat may be mounted on an exterior
wall above the heater if it is located in the same stud space as
the vent tubes and is a minimum of 6" (152mm) above the heater.
Interior Wall — The thermostat should be installed on an inside
wall away from the unit but in the same room.
Note: Use 16 gauge wire to prevent excessive loss of millivolts.
Proper operation depends on a good pilot ame. The ame must
cover the top of the thermopile. Cleaning of the pilot orice and
burner may be required due to spiders.
System Check
A millivolt meter is required to check the system. The millivolt
readings should be:
• Across the thermopile terminals, 400-450 millivolts with thermostat
OFF.
• Across the thermopile terminals, 150-250 millivolts with thermostat
ON.
• Across the thermostat wires at the valve, less than 30 millivolts
with thermostat ON.
• Across the thermostat wires at the thermostat, less than 5 millivolts
with thermostat ON. (Strong winds, dirty pilot and low pressure
will reduce readings.)
OPTIONAL THERMOSTAT LOCATION
Piezo Pilot Ignitor Instructions
Depressing the piezo ignitor button completely causes a spark to
occur at the pilot. This is a substitute for a match which requires
opening the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" (3mm)
from the thermopile. The spark must occur at the point the burner
ame hits the thermopile. The end of the electrode will be red hot
with the pilot on.
On a new installation with air in the gas line, it is suggested that a
match be used. The match will light the pilot faster than the piezo
under this condition.
To Conserve Gas: Turn off pilot when heater is not in use.
Figure 6

32193-3-0514 Page 11
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting (if applicable).
3. Turn off all electric power to the appliance (if appli-
cable).
4. Remove control access panel (front panel).
5. Push in gas control knob slightly and turn clockwise
to OFF.
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
6. Wait ten (10) minutes to clear out any gas. Then
smell for gas, including near the oor. If you smell
gas, STOP! Follow "B" in the safety information above.
If you don't smell gas, go to the next step.
7. Remove the pilot access cover located on the com-
bustion chamber.
8. Find pilot - follow metal tube
from gas control. The pilot is
behind the pilot access cover.
9. Turn knob on gas control counterclockwise
to "PILOT."
10. Push in control knob all the way and hold in. Im-
mediately light the pilot with the Piezo Pilot Ignitor
or a match. Continue to hold the control knob in for
about one (1) minute after the pilot is lit. Release
knob, and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 10.
• If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob to "OFF" and call
your service technician or gas supplier.
11. Replace pilot access cover.
12. Turn gas control knob counterclockwise
to "ON."
13. Replace control access panel (front panel).
14. Turn on all electric power to the appliance (if ap-
plicable).
15. Set thermostat to desired setting (if applicable).
16. CAUTION: Pilot access cover must be kept tightly
closed during operation.
TO TURN OFF GAS TO APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a re or explo-
sion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the oor because some
gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
re department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it; call a qualied
service technician. Force or attempted repair may
result in a re or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
LIGHTING INSTRUCTIONS
1. Set the thermostat to lowest setting.
2. Turn off all electric power to appliance if service is to
be performed (if applicable).
3. Remove control access panel (front panel).
4. Push in gas control knob slightly and turn clock-
wise to "OFF." Do not force.
5. Replace control access panel (front panel).
PILOT
BURNER THERMOPILE
LIGHTING INSTRUCTIONS

32193-3-0514Page 12
On the main burner, the burning gas forms a primary ame and a
secondary ame. The primary ame is blue and about 3/16" (5mm)
high. The secondary ame is very pale blue, 3 inches (76mm) to
5 inches (127mm) high. Dust in the combustion air will produce
an orange ame. Do not mistake it for an improper yellow ame.
Figure 8
Steps in Removing Main Burner, Orice and Valve
1. Disconnect the thermopile and pilot supply line at the pilot burner.
2. Remove the burner compartment cover 5/16" (8mm) socket
suggested.
3. Remove screw holding left side of burner and lift out.
4. Main burner orice is now accessible. Use 1/2" (13mm) box end
wrench to remove and apply non-hardening pipe dope sparingly
to orice threads when replaced.
5. To remove the entire gas valve the nut holding the orice tting
to the chamber must be removed and the gas supply to the
valve disconnected. After this, the valve and orice elbow can
be removed as a unit.
Cleaning The Pilot Burner
Cleaning of the pilot may be an annual necessity due to spiders.
After removing the supply tubing and orice, use a pipe cleaner or
wire to clean the entire internal part of the pilot.
Cleaning the Combustion Chamber and Main Burner
When the main burner and vent cap are removed, all internal areas of
the combustion chamber are accessible for cleaning with a vacuum
hose. The main burner may be cleaned by forcing water into the
ports and the throat of the burner. The burner should be blown dry
or heated to dry all water out before reinstalling.
The pilot ame is blue and goes toward the main burner and thermopile
horizontally. A slight yellow tip on the ame is normal. The pilot
ame must surround and extend approximately 1/4" (6mm) beyond
the thermopile, and must extend beyond the rst row toward the
second row of main burner ports.
Figure 7
PILOT FLAME CHARACTERISTICS
MAIN BURNER FLAME CHARACTERISTICS
MAINTENANCE

32193-3-0514 Page 13
1. Lit match goes out as it enters lighter port.
a. Certain wind conditions will blow out match. Ignite
match, and as it ares, thrust match through opening.
b. Open nearby door or window and relight pilot.
2. Pilot ames but goes out when knob is released.
a. See Lighting Instructions. Relight Pilot.
b. Relight the pilot and hold knob down longer and harder.
Close lighter hole cover just after igniting. Check for a
good pilot ame.
c. Defective thermopile or defective magnet in safety section
of valve. Replace.
3. Yellow pilot ame.
a. Obstruction at pilot orice.
b. Clean and properly size orice.
4. Pilot and main burner go out during normal operation.
a. Check millivolts.
b. Check for proper size of pilot ame.
c. Check for defective or weak thermopile.
d. Check input, reduce as needed.
e. Cover on pilot lighter hole must be air tight.
f. Check for tight t of air and ue tubes at both ends of vent
assembly. No obstruction around vent that would prevent
the wind from hitting all of the vent equally.
5. Thermostat does not turn the main burner on.
a. Check wiring.
b. Check all millivolt readings.
c. Check for spider in main burner orice.
6. Yellow main burner ame soot on the vent cap.
a. Remove main burner to check for obstructions in throat,
ports and orices.
b. Install new main burner orice and pilot orice. Refer to
Parts List on Page 14.
TROUBLESHOOTING

32193-3-0514Page 14
USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
Index
No.
Part
No. Description
1 TH100 WALL MOUNTING PLATE
2 TH104 GASKET - FOR WALL MOUNTING PLATE
3 TH015 AIR DROP ASSEMBLY - DV210
3 TH018 AIR DROP ASSEMBLY - DV215
4 11757 OUTER CASING - DV210
4 11758 OUTER CASING - DV215
5 TH142 INNER CASING - DV210
5 TH143 INNER CASING - DV215
6 TH008 FRONT PANEL - DV210
6 TH009 FRONT PANEL - DV215
7 TH024 COMBUSTION CHAMBER - DV210
7 TH027 COMBUSTION CHAMBER - DV215
8 M155 GASKET - OBSERVATION HOLE COVER
9 DV781 OBSERVATION HOLE COVER
10 DV064 COVER PLATE - OBSERVATION HOLE
11 R206 NUT FOR ORIFICE FITTING
12 P8654 BURNER ORIFICE - DV210 NAT
12 P8650 BURNER ORIFICE - DV215 NAT
12 P8665 BURNER ORIFICE - DV210 LPG
12 P8658 BURNER ORIFICE - DV215 LPG
13 P104 ORIFICE FITTING
14 R1055 ELECTRODE AND WIRE
15 P103 MANIFOLD
16 R5598 GAS VALVE 7000 MVRLC - NAT
16 R5599 GAS VALVE 7000 MVRLC - LPG
17 R2890 PILOT BURNER W/ORIFICE - LPG
17 R2893 PILOT BURNER WITH ORIFICE - NAT
18 TH335 PILOT SHIELD
19 M151 GASKET - PILOT BURNER
20 TH133 CHAMBER DOOR WITH GASKET - DV210
20 TH134 CHAMBER DOOR WITH GASKET - DV215
21 TH365 VALVE BRACKET
22 TH336 PILOT TUBING - 1/4" (6.4mm) WITH FER-
RELLS (Nat.)
22 TH367 PILOT TUBING - 1/4" (6.4mm) WITH FER-
RELLS (LP)
23 672064 THERMOPILE - GENERATOR
24 R2708 PIEZO IGNITOR
25 TH289 IGNITOR BRACKET
26 TH275 BURNER - DV210
26 24644 BURNER - DV215
27 TH109 3" (76mm) DIA. FLUE OUTLET TUBE
28 TH107 5" (127mm) DIA AIR INLET TUBE
29 TH331 OUTSIDE MOUNTING PLATE
30 TH334 VENT CAP
31 TH123 VENT KIT COMPLETE
N/S R1081 ORIFICE FOR PILOT - NAT
N/S 742266 ORIFICE FOR PILOT - LPG
N/S TH300 GASKET FOR CHAMBER DOOR - DV210
N/S TH281 GASKET FOR CHAMBER DOOR - DV215
N/S TH351 HARDWARE PACKAGE
N/S - NOT SHOWN
PARTS LIST
Index
No.
Part
No. Description

32193-3-0514 Page 15
PARTS VIEW

32193-3-0514Page 16
DVB-1 For Direct Vent Wall Furnaces DV-210-(7, 9)SG and DV-215-(7, 9)SG
INSTALLING OPTIONAL BLOWER DVB-1. The blower must be
positioned as shown in Figure 1. Relocate gas line, if necessary,
using elbow tting at the gas valve, and move Piezo Spark Genera-
tor to the next screw. A slot on the bottom of the blower package
engages a tab on the bottom of the inner casing and is secured by
one screw in front.
BLOWER
MOUNTING
TAB
Figure 1
Attaching Switch Box
1. Facing combustion chamber, remove (2) top, left screws on the
combustion chamber door.
2. Align (2) clearance holes on the switch box (with fan control)
over (2) clearance holes on the combustion chamber door.
3. Insert and attach (2) screws removed in Step 1 into switch box
and combustion chamber door.
4. Attach switch box cover to switch box with (1) No. 8 x 1/4" screw.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly into
a properly grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug. For an ungrounded receptacle,
an adapter, which has two prongs and a wire for grounding, can
be purchased, plugged into the ungrounded receptacle and its
wire connected to the receptacle mounting screw. With this wire
completing the ground, the appliance cord plug can be plugged
into the adapter and be electrically grounded. A 7/8" (22mm) hole
is provided in the junction box for use with a conduit connector if
local codes require this type of protection.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Warning:
Unplugging of blower accessory will not stop the heater from
cycling. To shut heater off: 1. Turn the temperature dial to lowest
setting, then turn thermostat to off. 2. Turn knob on gas control
to off, depressing slightly. Do not force.

32193-3-0514 Page 17
Index No. Part No. Description
1 R-1268 Wire Assembly
2 R-896 Bushing (Three Required)
3 R-1156 Fan Control
4 DV-806 Switch Box
5 DV-807 Switch Box Cover
6 TH-111 Junction Box
7 R-1410 Bushing (Strain Relief)
8 R-285 Motor
9 R-587 Motor Cushion
10 TH-341 Blower Cushion
11 TH-356 Motor Support Assembly
12 R-319 Blower Wheel
13 TH-135 Blower Housing Assembly
14 R-315 Cord Set
DVB-1 For Direct Vent Wall Furnaces DV-210-(7, 9)SG and DV-215-(7, 9)SG
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Oiling the Motor
Oiling holes are provided on each end of the motor for oiling. The
blower should have ve drops of #20 motor oil every 6 months.
Do not use machine oil.
Cleaning the Blower Wheel
In some areas, such as near bedrooms and on oors with a hard
surface, the blower wheel will be lled with lint very quickly. A visual
check of the blower wheel should be made after 30 days use. The
blower will run faster with a dirty wheel, but move less air. Remove
the entire blower and clean each blade of the wheel with a tooth
brush as often as necessary.

32193-3-0514Page 18
To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.
com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the
nature of the problem with the unit.
To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below.
This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.
Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equip-
ment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc.
Dey Distributing
1401 Willow Lake Boulevard
Vadnais Heights, MN 55101
Phone: 651-490-9191
Toll Free: 800-397-1339
Website: www.deydistributing.com
Parts: Heater, Hearth and Grills
East Coast Energy Products
10 East Route 36
West Long Branch, NJ 07764
Phone: 732-870-8809
Toll Free: 800-755-8809
Fax: 732-870-8811
Website: www.eastcoastenergy.com
Parts: Heater, Hearth and Grills
Victor Division of F. W. Webb Company
200 Locust Street
Hartford, CT 06114
Phone: 860-722-2433
Toll Free: 800-243-9360
Fax: 860-293-0479
Toll Free Fax: 800-274-2004
Websites: www.fwwebb.com & www.victormfg.com
Parts: Heater, Hearth and Grills
MASTER PARTS DISTRIBUTOR LIST
Parts Not Under Warranty
Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu-
tors list. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the
service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is required for
warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts, rst obtain the Model Number and Serial Number from the
name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the fol-
lowing illustration and part list. Be sure to give all this information . . .
Appliance Model Number Part Description
Appliance Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, res and all causes beyond our control.
HOW TO ORDER REPAIR PARTS

32193-3-0514 Page 19
WARRANTY
Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods
specied below. Space heating products must be installed by a qualied technician and must be maintained and operated safely, in
accordance with the instructions in the owner’s manual. This warranty applies to the original purchaser only and is not transferable. All
warranty repairs must be accomplished by a qualied gas appliance technician.
Limited Ten-Year Parts Warranty – Combustion Chamber
Empire promises to the owner that if the combustion chamber (see parts list) fails because of defective workmanship or material with
ten years from the date of purchase, Empire will repair or replace at Empire’s option.
Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts
Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from
the date of purchase, Empire will repair or replace at Empire’s option.
Duties Of The Owner
The appliance must be installed by a qualied installer and operated in accordance with the instructions furnished with the ap-
pliance.
A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period.
Ready access to the appliance for service.
What Is Not Covered
Damages that might result from the use, misuse, or improper installation of this appliance.
Travel, diagnostic costs and freight charges on warranted parts to and from the factory.
Claims that do not involve defective workmanship or materials.
Unauthorized service or parts replacements.
Removal and reinstallation cost.
Inoperable due to improper or lack of maintenance.
How To Get Service
To make a claim under this warranty, please have your receipt available and contact your installing dealer. Provide the dealer
with the model number, serial number, type of gas, and purchase verication. The installing dealer is responsible for providing service and
will contact the factory to initiate any warranted parts replacements. Empire will make replacement parts available at the factory. Shipping
expenses are not covered.
If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department,
Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to [email protected] with “Consumer Rela-
tions” in the subject line.
Your Rights Under State Law
This warranty gives your specic legal rights, and you may also have other rights, which vary from state to state.

32193-3-0514Page 20
EMPIRE
EMPIRE
Comfort Systems
Empire Comfort Systems Inc.
918 Freeburg Ave. Belleville, IL 62220
If you have a general question about our products, please e-mail
If you have a service or repair question, please contact your
dealer.
www.empirecomfort.com
This manual suits for next models
1
Table of contents
Languages:
Other Empire Wall Furnace manuals

Empire
Empire DV-20E-5 Quick start guide

Empire
Empire DV-20E-5 Quick start guide

Empire
Empire FAW55IPXLP-2 Quick start guide

Empire
Empire FAW40IPXLP-1 Quick start guide

Empire
Empire DV215SGXLP-2 Quick start guide

Empire
Empire FAW40SPPXLP-1 Quick start guide

Empire
Empire DV-25-2SG Quick start guide

Empire
Empire DVC55IPXLP-2 Quick start guide

Empire
Empire DV-210-7SG Quick start guide

Empire
Empire DV-55IP Quick start guide