manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EMS
  6. •
  7. Personal Care Product
  8. •
  9. EMS EMS MESOGUN SR-NV6130 Mounting instructions

EMS EMS MESOGUN SR-NV6130 Mounting instructions

Popular Personal Care Product manuals by other brands

Pretika ST102 Instructions for use & warranty information

Pretika

Pretika ST102 Instructions for use & warranty information

Beurer FC 76 Instructions for use

Beurer

Beurer FC 76 Instructions for use

Pebble Grey 500.40.70-75 manual

Pebble Grey

Pebble Grey 500.40.70-75 manual

PUSH ortho quick start guide

PUSH

PUSH ortho quick start guide

Dermlite DL3N instructions

Dermlite

Dermlite DL3N instructions

DERMAPEN SEMI user manual

DERMAPEN

DERMAPEN SEMI user manual

HiB Spectre 50 manual

HiB

HiB Spectre 50 manual

Carex SunLite user guide

Carex

Carex SunLite user guide

Roper Rhodes Intense Installation & Aftercare Instructions

Roper Rhodes

Roper Rhodes Intense Installation & Aftercare Instructions

Interacoustics Titan IMP440 Setup & installation

Interacoustics

Interacoustics Titan IMP440 Setup & installation

ReTrak VS001 user guide

ReTrak

ReTrak VS001 user guide

LED Technologies dpl PAIN RELIEF Joint Wrap user guide

LED Technologies

LED Technologies dpl PAIN RELIEF Joint Wrap user guide

Casa Lusso MVL1000x450PR installation instructions

Casa Lusso

Casa Lusso MVL1000x450PR installation instructions

Quoizel QR3326 Assembly instruction sheet

Quoizel

Quoizel QR3326 Assembly instruction sheet

BERTSCHAT HEATED HOODIE PRO - DUAL HEATING user manual

BERTSCHAT

BERTSCHAT HEATED HOODIE PRO - DUAL HEATING user manual

Beurer EM 37 Instructions for use

Beurer

Beurer EM 37 Instructions for use

ACP OMNISTAND user manual

ACP

ACP OMNISTAND user manual

Scarlett VitaSpa SC-CA304PS11 instruction manual

Scarlett

Scarlett VitaSpa SC-CA304PS11 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EMS Mesogun Use Manual
Model:SR-NV6130
Notice
Dear Customer:
Thank you for your choice of our company and manufactured instruments,
in order to better play the effectiveness of the product, we sincerely
recommend:
Before using the instrument, please read this user manual carefully and
keep it for future reference.
Please install, use and operate properly according to the manual.
Do not disassemble this unit and modify any parts.
In addition to our authorized personnel, it is forbidden for others to open
the cover and open the host.
Non-professionals are strictly forbidden to carry out maintenance and
renovation without authorization.
If there is any fault during the operation, please contact us.
This product does not belong to medical equipment, do not use for
disease treatment!
Use of the site
1) Please do not use and plug in the socket to avoid causing fire disaster ;
2) When changing the fuse, it is necessary to turn off the power switch to avoid
fire and electric shock.
3) The use of broken or processed power lines has the risk of fire and electric
shock ;
4) Do not bend or sway the power supply line too much to avoid fire and
electric shocks ;
5) If the instrument is loose or damaged , please contact the company at the
same time ;
6) Do not use the instrument in an unstable environment such as tilting ,
vibrating or bumping ;
7) There is no water or debris in the instrument . If there is any foreign matter
entering , please contact the company at any time ;
8) The power plug must be unplugged when the instrument is moving ;
9) When the instrument is moving, vibration should be avoided as much as
possible ;
10) The instrument should be placed in a stable place , and at least 5 cm
space should be left around to ensure the air flow and facilitate the heat
dissipation of the instrument ;
11) The instrument can't cover any east to prevent the air outlet from plugging ;
12) Avoid using the instrument in the following environments: sunlight
exposure; high humidity environment; near water environment; vibration, tilting
place; strong magnetic field environment; electromagnetic wave, surge voltage
occurrence place; chemical storage place, Corrosive gas place;
13 ) The instrument should not be placed near the receiver , TV , copying
machine , or fax machine
14) It should not be used in combination with other instruments (such as
microwave) to avoid interference between the instruments and cause wrong
operation.
Precautions before use
1)Read the instructions for use before you start the machine. The operator
must be familiar with the instructions and operating methods , and the
instrument must be managed by a special person ; 2 ) The setting of the
operating parameters should be set by the professional staff ;
1) Note:
3 ) Verify that the instrument is in normal operation before use ;
4 ) Make sure that the grounding wire is connected correctly ;
5 ) Make sure that all the wires are properly connected and secure ;
6) When using the instrument together, it must be used correctly, otherwise it
may be dangerous and must be noticed.
Contraindications
1.skin sensitive, severe asthma
2. Cardiac rhythm, implantable cardiac defibrillator or other electromagnetic
implantable medical device
3. Severe diabetic patients, high blood pressure and high blood lipids
4. skin infections
1、The Brief Introduction of Instrument
1.1 structure of machine
2.1 Installation of machine
2.1.1 Unpack and check
Carefully remove the instrument and accessories from the package and
store the package for later transport or storage. Check the attachment by
pressing the packing list. Check if there is any mechanical damage.
Remark: If have some damage, please contact our agent.
2.2 The instrument should be placed in a clean, ventilated room with a
temperature of 5 °C ~ 40 °C, a humidity of no more than 80%,
avoiding direct sunlight. Also make sure that the air vents are not
blocked, ensuring that there is at least 5cm of clearance around the
instrument. Remember not to place objects on the instrument, even if it
is temporary.
2.3 Inserting the accessory frame into the connector on the right side of
the instrument. Please according to the below:
2.4 Handle operation method and steps:
2.4.1 Installing handle
2.4.2 Fix the clip on the nanocrystal head to the fixing clip on the handle,
and insert it clockwise.
2.4.3 Pour the solution into the liquid bottle
2.Operating steps
2.1 Paving the disposable pad on the cart, placing the prepared materials
neatly and vacating a small area as the dispensing area. This area should be
kept clean, can not be placed indiscriminately, and cannot be easily crossed.
Brine is filled into 6 pieces of disposable gauze;
2.2 Clean the face
2.3 Put on the inspection gloves and thoroughly use the alcohol gauze to
thoroughly clean the instrument and the base of the main unit. Disinfect it once,
and disinfect the handle with a small cotton swab dipped in alcohol.
2.4 Dispose the disposable nanochip and install the original liquid bottle to the
operation. Inside the handle card slot;
2.5 Start the machine, enter the operation interface, select the demonstration
mode or use the I C card to enter the card;
2.6 Put the salt water into the solution bottle and put it on the handle.
2.7 installing the nanochip and click the button of tube cleaning to clean it.
2.8 After finishing the cleaning, click the button and return to the main
operation interface ;
2.9 Put the product into the solution bottle and put it on the handle .
2.10 Clicking EMS , select the skin sensitivity , propose from 2 to adjust.
2.11 Click RF then adjust energy from 2.
2.12 speed is recommended to adjust 5 (the faster the speed , the more
obvious the tingling ) , the dosage is recommended to adjust 8 or 9.
2.13 Put on the surgical hand cover and wipe the face with the raw salt water
gauze block twice.
1.tube cleaning 2 language 3 time setting 4 EMS energy 5 skin type 6RF open and energy
adjust7 speed 8 account 9 ID card 10 open/close 11 EMS switch
2.14 Click the start button to use two disposable medical cotton swabs to
tighten the skin. The handle is attached to the skin vertically and from the
bottom to the top according to the texture of the skin. (Note: Before operation,
press the handle to adjust the dose button”+”, to see if the instrument is
normally out of the liquid, and then operate. When you are operating, look at
whether solution bottle is vertical, and change the direction of the handle at
any time.)
2.15 Wipe the medical repairing gel. After 20 minutes, clean and dry.
2.16 Use Medical wound repairing mask, after 20mins ,unloading mask and
use raw salt water gauze block clean.
2.17 After treatment, clean the instrument pipeline, first start the instrument to
drain the residual product in the pipeline, then put the warm water of about 40
degrees into the solution bottle, install the device to the handle, click the
screen to let the instrument automatically clean the pipe. After the warm water
bottle is cleaned, then click finish.
3.Precautions after use
3.1 In treatment part, It’s a normal phenomenon that appears some reddish and some small particles will
it will disappear within a week.
3.2 The skin can't touch the water within 6 hours after the operation. B B cream can be used on