EMS FireCell FCX-100-101 User manual

www.emsgroup.co.uk
RadioDetector Base
PRESSHERE TO
LOGON
IDENT
www.emsgroup.co.uk
RadioDetector Base
PRESSHERE TO
LOGON
IDENT
www.emsgroup.co.uk
RadioDetector Base
PRESSHERE TO
LOGON
IDENT
63mm
1Pre Installation
4 Power Device
To unlock, insert a 1.5mm
Allen key into the Allen
key slot and turn
anticlockwise as shown.
3 Fix Mounting Plate
2Components
device
unpowered
(pins unlinked)
device
powered
(both pins linked)
!
Installation must conform to applicable local installation
codes and
should only be installed by a fully trained
competent person.
Ensure that the device is installed as per the site survey.
The use of a non-metallic spacer should be considered if
mounting the device on to a metal surface.
Do NOT Press the Log On button on a pre-programmed
device. This will cause communication with the Control Panel
to be lost. Should this happen, delete the device from the
system and add it back on.
Detector Wireless Module inc 300mm cable Mounting Plate
Remove the mounting plate from the wireless module, by turning
it anticlockwise.
5 Optional Device Locking 6 Configuration
To lock the detector into
the wireless module,
insert a 1.5mm Allen key
into the allen key slot and
turn clockwise as shown.
Use both mounting holes to ensure a firm fixing.
Use suitable fasteners and fixings.
Once powered, reassemble the device.
The device’s loop address is configured within the menu structure
of the Radio Hub.
Refer to the programming manual (Doc Ref: MK98) for full
programming information.
Free to download from
www.emsgroup.co.uk
Wireless Detector c/w Remote Indicator
Installation Guide
FCX-100-101 Optical Smoke Detector & Remote Indicator Unit
[2][3]
FCX-120-101 Heat A1R Detector c/w Remote Indicator Unit [1][3]
FCX-120-111 Heat CS Detector c/w Remote Indicator Unit [1][3]
FCX-170-101 Wireless Detector Base c/w Remote Indicator Unit [3]
5-RIM Remote Indicator Unit Only
Example shown:
Model FCX-100-101
Part No Product Description
See the Specification section for compliance information.
CPR
SIZE AA
SIZE AA
SIZE AA
SIZE AA
SIZE AA
SIZE AA
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE 56
Dust Cover
4
OBSERVE CORRECT POLARITY, USING SPECIFIED BATTERIES.
If fitting / re-fitting batteries; observe correct polarity, using
only specified batteries.
Connect the power jumper across the PIN header.
www.emsgroup.co.uk
RadioDetector Base
PRESSHERETO
LOGON
IDENT
2 31 5
6
4 7
Front Cover Mounting Plate
23
7
Fixing Screws
1
Remote Indicator Unit Wireless Detector
©2018 EMS Ltd. All rights reserved Page 1 of 2 TSD033 Iss 3 05/09/2018 AJM
www.emsgroup.co.uk
Radio Detector Base
PRESSHERE TO
LOGON
IDENT
All manuals and user guides at all-guides.com
all-guides.com
Closed Electrical
Connector
www.emsgroup.co.uk
Radio Detector Base
PRESSHERE TO
LOGON
IDENT
FCX-100-101 Optical Smoke Detector & Remote Indicator Unit
[2][3]
FCX-120-101 Heat A1R Detector c/w Remote Indicator Unit [1][3]
FCX-120-111 Heat CS Detector c/w Remote Indicator Unit [1][3]
FCX-170-101 Wireless Detector Base c/w Remote Indicator Unit [3]
5-RIM Remote Indicator Unit Only
Operating
Temperature -10°C to 55°C
Storage
Temperature 5°C to 30°C
Humidity Up to 95% non-condensing
Supply 6x AA Alkaline (Panasonic LR6AD Powerline /
Varta 4006 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certification and
may result in poor performance.
IP Rating IP23
Operating
Frequency 868MHz
Output
Transmitter
Power Auto adjusting 0 - 14 dB (0 - 25 mW)
Dimensions (mm) 85(H) x 85(W) x 45(D) (Remote Indicator Unit)
113 (Ø) 81 (D) (Wireless Detector)
Weight 0.15kg (Remote Indicator Unit)
0.40kg (Wireless Detector)
Location Type A: For indoor use
2012/19/EU (WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon purchase of
equivalent new equipment, or dispose of it at
designated collection points. For more information
see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly manner according to your local
regulations.
European Union
directives
EMS declares that the radio equipment type FireCell
Detector c/w Remote Indicator is in compliance with
Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the
following internet address:
www.emsgroup.co.uk
Certification
Certification body
CPR Certificate See part listing for associated products:
DOP [1]0359-CPR-0015, [2]0359-CPR-0017 &
[3]0359-CPR-0041
0359
10
IMPORTANT
Remove dust cover before use.
The device should be tested upon installation and in accordance
with local requirements.
Testing should only be carried out by a fully trained competent
person.
The Manufacturer recommends regular functional testing of at
least once per annum or in accordance with local codes of
practice.
Cleaning and repairs must be undertaken by the Manufacturers
authorised representative.
Do not open the case to clean inside the detector.
!
Specification
See part listing for associated products:
EN54-5:2001. Incorporating Amendment No. 1.
Fire detection and fire alarm systems.
Part 5: Heat detectors - Point Detectors. [1]
EN54-7:2001. Incorporating Amendment No. 1. Fire
detection and fire alarm systems.
Part 7: Smoke detectors - Point detectors using
scattered light, transmitted light or ionization. [2]
E
N54-25:2008.Incorporating corrigenda September
2010 and March 2012. Fire detection and fire alarm
systems.
Part 25: Components using radio links. [3]
Approved to
Regulatory Information
Manufacturer EMS Ltd. Technology House, Herne Bay, Kent,
CT6 8JZ, United Kingdom
Year of
manufacture See devices serial number label
Only use knockouts
shown in shaded
areas.
7 Remove Cable Entry Points 8 Fix to the Wall
40mm
40mm
Use all four mounting
holes.
Use suitable fasteners
and fixings.
9 Wiring
Connect using the two way + and - terminals, observing
correct polarity.
Pass the cable through the premade entry points.
Cabling can be extended up to 30m if required, using a closed
electrical connector.
A maximum of one detector is to be fitted to the Remote
Indicator
©2018 EMS Ltd. All rights reserved Page 2 of 2 TSD033 Iss 3 05/09/2018 AJM
All manuals and user guides at all-guides.com

This manual suits for next models

3

Other EMS Security Sensor manuals

EMS FireCell FCX-175-001 User manual

EMS

EMS FireCell FCX-175-001 User manual

EMS FireCell FCX-170-001 User manual

EMS

EMS FireCell FCX-170-001 User manual

EMS FCX-100-001 User manual

EMS

EMS FCX-100-001 User manual

EMS FireCell FCX-170-001 User manual

EMS

EMS FireCell FCX-170-001 User manual

EMS FireCell FCX-100-101 User manual

EMS

EMS FireCell FCX-100-101 User manual

Popular Security Sensor manuals by other brands

Rosslare SA-01P installation manual

Rosslare

Rosslare SA-01P installation manual

Bacharach Tru Pointe 2100 Operation and maintenance guide

Bacharach

Bacharach Tru Pointe 2100 Operation and maintenance guide

AccuLine 40-6715 instruction manual

AccuLine

AccuLine 40-6715 instruction manual

ASENWARE AW-D302 instruction manual

ASENWARE

ASENWARE AW-D302 instruction manual

ZooZ ZSE42 800LR user manual

ZooZ

ZooZ ZSE42 800LR user manual

SEA LOOP 23105158 manual

SEA

SEA LOOP 23105158 manual

MEDC BGE Technical manual

MEDC

MEDC BGE Technical manual

B.E.G. LUXOMAT PD2N-KNX-ST-UP Mounting instructions

B.E.G.

B.E.G. LUXOMAT PD2N-KNX-ST-UP Mounting instructions

Bosch ISN-AP1 installation instructions

Bosch

Bosch ISN-AP1 installation instructions

Aritech ShatterPro 3 installation instructions

Aritech

Aritech ShatterPro 3 installation instructions

nedis ZBSD10WT user manual

nedis

nedis ZBSD10WT user manual

LST OH-13001 Specification sheet

LST

LST OH-13001 Specification sheet

Isolite Max Series instructions

Isolite

Isolite Max Series instructions

Honeywell C7076F Product handbook

Honeywell

Honeywell C7076F Product handbook

sewerin Duophon operating instructions

sewerin

sewerin Duophon operating instructions

Halma BEA ACTIV8 THREE ON user guide

Halma

Halma BEA ACTIV8 THREE ON user guide

Visonic CLIP SMA installation instructions

Visonic

Visonic CLIP SMA installation instructions

C-LOGIC 640-MD instruction manual

C-LOGIC

C-LOGIC 640-MD instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.