Operating
temperature -10 to +55 °C
Storage
temperature 5 to 30 °C
Humidity 0 to 95% non-condensing
Supply 6x AA alkaline (Panasonic LR6AD Powerline /
Varta 4006 Industrial)
CAUTION!
Fitting of an incorrect battery type invalidates the product certification and
may result in poor performance.
IP rating IP23
Operating
frequency 868 MHz
Output
transmitter
power Auto adjusting 0 to 14 dBm (0 to 25 mW)
Dimensions (Ø x D) 113 x 40 mm (without detector)
113 x 76 mm (with smoke detector)
113 x 81 mm (with heat detector)
113 x 87 mm (
with multisensor detector)
Weight 0.40 kg (with detector)
Location Type A: For indoor use 2012/19/EU (WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon purchase of
equivalent new equipment, or dispose of it at
designated collection points. For more information
see www.recyclethis.info
Dispose of your batteries in an environmentally
friendly manner according to your local
regulations.
European Union
directives
EMS declares that this device is in compliance with
Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the
following internet address: www.emsgroup.co.uk
Certification
Certification body
CPR DoP See part listing for associated products:
[1]0359-CPR-0015, [2]0359-CPR-0017,
[3]0359-CPR-0041 & [4]0905-CPR-202126
0905
10[1][2][3] 20[4]
7 Configuration IMPORTANT
Remove dust cover before use.
The device should be tested upon installation and in accordance
with local requirements.
Testing should only be carried out by a fully trained competent
person.
The manufacturer recommends regular functional testing of at
least once per annum or in accordance with local codes of
practice.
Cleaning and repairs must be undertaken by the manufacturers
authorised representative.
Do not open the case to clean inside the detector.
!
Specification
See part listing for associated products:
EN54-5:2001. Incorporating Amendment No. 1.
Fire detection and fire alarm systems.
Part 5: Heat detectors - Point Detectors. [1]
EN54-7:2001. Incorporating Amendment No. 1. Fire
detection and fire alarm systems.
Part 7: Smoke detectors - Point detectors using
scattered light, transmitted light or ionization. [2][4]
E
N54-25:2008.Incorporating corrigenda September
2010 and March 2012. Fire detection and fire alarm
systems.
Part 25: Components using radio links. [3]
Approved to
Regulatory information
Manufacturer Carrier Manufacturing Polska Sp. Z o.o. Ul.
Kolejowa 24. 39-100 Ropczyce, Poland
Year of
manufacture See devices serial number label
©2021 EMS Ltd. All rights reserved Page 2 of 2 TSD044-99 Iss 15 23/11/2021 AJM
The device’s loop address is configured within the user interface’s
menu structure.
Refer to the programming manual for full programming details.
Free to download from
www.emsgroup.co.uk
FireCell = MK98
Fusion = TSD062
WZM = TSD143