Emulex OneConnect OCe10102 CNA User manual

OneConnect
OCe10102 CNA
Installation Manual
One Network.
One Company.
P004450-02A Rev. A Connect with Emulex.
TM

Emulex OneConnect OCe10102 CNA Installation Manual Page ii
EMULEX CONFIDENTIAL. Copyright © 2003-2009 Emulex. All rights reserved worldwide. Unpublished work.
No part of this document may be reproduced by any means or translated to any electronic medium without (a) the
prior written consent of Emulex, and (b) the preservation of this notice on all copies and partial copies. Copying,
access, use or distribution requires an applicable written agreement approved by Emulex.
Information furnished by Emulex is believed to be accurate and reliable. However, no responsibility is assumed by
Emulex for its use; or for any infringements of patents or other rights of third parties which may result from its use.
No license is granted by implication or otherwise under any patent, copyright, trade secret or related rights of
Emulex.
Emulex, the Emulex logo, AutoPilot Installer, AutoPilot Manager, BlockGuard, Connectivity Continuum,
Convergenomics, Emulex Connect, Emulex Secure, EZPilot, FibreSpy, HBAnyware, InSpeed, LightPulse,
MultiPulse, OneCommand, OneConnect, One Network. One Company., SBOD, SLI, and VEngine are trademarks of
Emulex. All other brand or product names referenced herein are trademarks or registered trademarks of their
respective companies or organizations.
Emulex provides this documentation "as is" without any warranty of any kind, either expressed or implied, including
but not limited to the implied warranties of merchantability or fitness for a particular purpose. Emulex may make
improvements and changes to the product described in this manual at any time and without any notice. Emulex
assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties that may
result. Periodic changes are made to information contained herein; although these changes will be incorporated into
new editions of this documentation, Emulex disclaims any undertaking to give notice of such changes.
US patent notice is given for one or more of the following: 6226680, 6247060, 6334153, 6389479, 6393487,
6427171, 6427173, 6434620, 6591302, 6658480, 6697868, 6751665, 6757746, 6941386, 6965941, 6687758,
7042898, 7133940, 7124205, 7089326, 6938092, 6996070.
Emulex, 3333 Susan Street
Costa Mesa, CA 92626

Emulex OneConnect OCe10102 CNA Installation Manual Page iii
Table of Contents
Introduction...................................................................................................................................................1
Major Features ................................................................................................................................1
Prerequisites....................................................................................................................................2
Installing the Converged Network Adapter......................................................................................2
Viewing the LEDs ............................................................................................................................7
References...................................................................................................................................................8
Specifications ..................................................................................................................................8
FCC and Regulatory Notices...........................................................................................................9
Declaration of Conformity..............................................................................................................10
Laser Safety Notice.......................................................................................................................12

Emulex OneConnect OCe10102 CNA Installation Manual Page 1
Introduction
This manual describes the Emulex®OneConnect™OCe10102 multi-protocol PCI-Express Converged
Network Adapter (CNA) for 10 Gigabit Enhanced Ethernet (EE) fabric. Emulex CNAs provide both
traditional networking interface card (NIC) and iSCSI functionality and storage networking functionality
as well as Fibre Channel over Ethernet (FCoE) functionality for convergence of Fibre Channel (FC)
traffic onto 10 Gigabit EE fabric.
Emulex CNAs combine two major functional components: a 10 Gigabit networking MAC and an FC IOC
to interface with a unified lossless Ethernet switch. The CNA serves as a common interface for both
storage and IP traffic retaining familiar FC and networking software stacks, OS drivers, and
management. The supported PCIe connector is an x8. Each CNA is compliant to the PCI Express Base
Specification 2.0.
Figure 1: The Emulex OCe10102 CNA
Major Features
• Single 8-lane standard Generation 2, PCIe interface
• Low-profile PCIe form factor PCBA: 6.600 inches by 2.713 inches
• Comes with full height I/O bracket installed for low profile cards
• Optional low profile I/O bracket is included
• Optical 10 GbE network interface LC connectors
• Copper 10 GbE SFP+ direct-attach connectors
• On-board flash memory: 8M bytes for FC controller program storage
• On-board configuration EEPROM to set FCoE or iSCSI modes of operation (Not changeable in
the field)
• Uses standard Emulex SLI drivers
• Interoperates with existing FC SAN infrastructures - switches, arrays, SRM tools (including
Emulex utilities), SAN practices, and so forth
• Unified Ethernet to FC SAN connectivity provided by FCoE switch
• Provides 10 Gb MAC features such as MSI-X support, jumbo frames (9024 bytes) support,
VLAN tagging (802.1Q, PER priority pause / priority flow control), and advanced packet filtering

Emulex OneConnect OCe10102 CNA Installation Manual Page 2
• No host operating system changes are required, that is, NIC and HBA functionality (including
device management, utilities, and so forth) are transparent to the host operating system.
Prerequisites
• PCI Express 2.0 compliant systems: x8 or x16 lane transfer link interface at up to 5 Gb/s per
lane.
CNA Identification
Each CNA is shipped with several numbers clearly marked on the board Including:
• The IEEE Address
• The World Wide Name (wwn)
• The serial number
• The IEEE address is a unique 64-bit identifier that you use when configuring your system. The
FC industry uses the World Wide Name (wwn) derived from the IEEE address for FC
connectivity. If the adapter has two ports, it has two IEEE addresses and two wwns, one for each
port. Use the serial number when communicating with Emulex. Record these numbers before
installation.
Installing the Converged Network Adapter
The Emulex OCe10102 CNAs use removable optical transceivers or copper interface cables.
Preparing the CNA for Installation
1. Turn off the computer and unplug it.
2. Remove the computer case.
3. Follow steps 4–12 to change the bracket if you want the low profile. Otherwise, skip to “Installing
the Adapter” on page 4.
4. To change the bracket, you must first remove the transceiver from its cage assembly.
CAUTION: This is a delicate operation–take care not to damage the transceiver.
The CNA uses different types of transceivers. Figure 2 shows an example of one type of trans-
ceiver with the bail (handle) extended.
Figure 2: A typical optical transceiver
Note: The CNA comes with a standard PCIe bracket installed. A low-profile bracket is
included in the box with the CNA. The low-profile mounting bracket is shorter than the
standard bracket; approximately 3.11 in. (7.9 cm) compared to 4.75 in. (12.06 cm) long.

Emulex OneConnect OCe10102 CNA Installation Manual Page 3
5. To remove the transceiver, pull the bail (handle) out and down to release the latch and gently pull
the transceiver out. Do not force it. After the latch is released, the transceiver slides out easily.
Figure 3 shows one transceiver partly extracted and the other latched in place.
Figure 3: Removing a transceiver
6. Observing Electrostatic Discharge (ESD) precautions, store the transceiver in an ESD-safe place.
7. Remove the mounting bracket screws from the top of the CNA. Figure 4 shows the screws that
attach the bracket.
Figure 4: Removing the Bracket

Emulex OneConnect OCe10102 CNA Installation Manual Page 4
8. Remove the bracket and store it for future use.
9. Align the new mounting bracket tabs with the holes in the CNA.
10. Re-install the screws that attach the CNA to the bracket.
11. Re-install the transceiver by sliding it into the housing. When the latch engages, it clicks.
12. Push the bail back into place.
Installing the Adapter
1. Turn off and unplug the computer.
2. Remove the computer case.
3. Remove the blank panel from an empty PCIe bus slot. See “Preparing the CNA for Installation” on
page 2 to change the brackets if needed. Otherwise, skip to “Attaching Media” on page 4.
4. Insert the CNA into the empty x8 or x16 PCIe bus slot. Press firmly until the adapter is seated.
5. Secure the CNA's mounting bracket to the case with panel screw or clip.
6. Replace the computer case and tighten case screws.
The CNA is now installed in the server and is ready for media attachment.
Attaching Media
Figure 5 shows the CNA and the optical transceivers.
Figure 5: CNA with Optical Transceivers
Note: Be careful not to push the bracket past the transceiver housing's grounding tabs. Make
sure the light emitting diodes (LEDs) are properly aligned with the holes in the bracket.
Note: Place the CNA into an empty PCIe x8 or x16 slot. Make sure that the adapter is in an
appropriate PCIe slot that does not interfere with other components or case to
prevent damage to the CNA.
Note: A CNA does not allow normal data transmission on either 10 Gb optical or copper link
unless it is connected to a compatible optical or copper interface connection (that is,
multimode to multimode).

Emulex OneConnect OCe10102 CNA Installation Manual Page 5
Note: Use SR, DCR multimode fiber, or 1 to 5 meter SFP+ 10GbE copper cable for interface connections to a
network that adheres to the following specifications:
Note: Some CNA models ship without transceivers for use with Direct Attach Copper cables.
CAUTION: Take care not to plug optical cables into cages without transceivers in them.
Table 1. Media Specifications
Fiber Optic Cable Maximum Length Minimum Length Connector
Short Range, LC-LC Multimode
OM3 - 50/125 Duplex 300 meters (984.25 ft) 1 meter LC
Copper Cable Maximum Length Minimum Length Connector
10GbE Direct-Attach Passive-Copper Cable 5 meters (16.4 ft) 1 meter Direct Attach

Emulex OneConnect OCe10102 CNA Installation Manual Page 6
To attach media to the CNA:
1. Connect the optical cable to the LC connectors on the CNA (see figure 6).
Or:
Insert the Direct Attach Copper transceiver into the SFP+ cage on the CNA (see figure 7).
Figure 6: Connecting Fiber Optic Cable
Figure 7: Connecting the Direct Attach Copper cable

Emulex OneConnect OCe10102 CNA Installation Manual Page 7
2. Connect the other end of the cable to a suitable switch such as a Top of Rack (TOR) EE switch.
After the media is connected to the CNA, you are ready to apply power to the computer.
Applying Power
To apply power:
1. Verify that the CNA is securely installed in the computer.
2. Verify that the correct media is attached.
3. Plug in and turn on the computer.
4. Observe the boot banner for Power On Self Test (POST) results.
Viewing the LEDs
Green and amber LEDs can be seen through openings in the CNA's mounting bracket. Each
corresponding LED is summarized below:
Activity: (Green) (Ethernet Link)
Blink = Activity
Off = No activity
Link (Amber)
On (constantly) = Link up
OFF = Link down
Figure 8: CNA LED Indicators

Emulex OneConnect OCe10102 CNA Installation Manual Page 8
References
Specifications
Table 2. OCe10102 CNA Specifications
Parameter Range
Physical Dimensions Low-profile form factor, 6.600 inches by 2.713 inches, and accommodates both
the full-height and low-profile bracket.
Power Requirements 14.5 Watts typical
Airflow 150 lf/min (minimum)
Temperature 0 °C to 55 °C (+32 °F to +131 °F)
Humidity 5% to 85% (non-condensing)
40 °C, 16 hour dwells at extremes
Agency Approvals for
OCe10102 CNA • Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1
• UL recognized to UL60950-1 2nd Edition
• CUR recognized to CSA 22.2, No. 60950-1-07
• TUV certified by to EN60950-1
• FCC Rules, Part 15, Class A
• Industry Canada, ICES-003, Class A
• EMC Directives 2004/108/EEC (CE Mark)
EN55022, Class A
EN55024
• Australian EMC Framework (C-Tick Mark)
AS/NZS CISPR22:2006 Class A
• Japan VCCI, Class A
• Taiwan BSMI, Class A
• Korea KCC, Class A
• RoHS Compliant (Directive 2002/95/EC)
• China RoHS compliant
Vibration, peak
acceleration 0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)

Emulex OneConnect OCe10102 CNA Installation Manual Page 9
FCC and Regulatory Notices
OCe10102 CNA Model
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense. The reader is cautioned that
changes or modifications made to the equipment not expressly approved by Emulex could void the
user's authority to operate this equipment. The above statement applies to products marketed in the
USA.
This class A digital apparatus meets all requirements of the Industry Canada (IC) Interference - Causing
Equipment Standard (ICES-003).
Cet appareil numerique de la Classe A respecte toutes les exigences du reglement sur le materiel
brouilleur du Canada. This statement applies to products marketed in Canada.
Notice for Japan and Translations (VCCI)
Translation:
This is a Class A product. If this equipment is used in a domestic environment, radio interference may
occur, in which case, the user may be required to take corrective action. VCCI—A.
Responsible Party:
Jim McCluney, Chief Executive Officer
Emulex Corporation (714) 662-5600
3333 Susan St. Costa Mesa, CA. 92626 USA

Emulex OneConnect OCe10102 CNA Installation Manual Page 10
Notice for Taiwan and Translations (BSMI)
Translation:
This equipment is a Class A ITE, and operation of this equipment in a residential area is likely to cause
harmful interference, in which case users will be required to correct the interference at their own
expense.
Notice for South Korea and Translations (KCC)
Translation:
Class A Equipment: Please note that this equipment has been approved for business purposes with
regards to electromagnetic interference. If purchased in error for use in a residential area, you may wish
to exchange the equipment where you purchased it.
Declaration of Conformity
OCe10102 CNA
This equipment complies with CISPR22/EN55022 Class A.
WARNING: This is a class A product. In a domestic environment, this product may cause radio
interference requiring the user to take adequate measures.
Note: Changes or modifications not expressly approved by Emulex Corporation could void
the user's authority to operate this equipment.

Emulex OneConnect OCe10102 CNA Installation Manual Page 11
DECLARATION OF CONFORMITY
Manufacturer: Emulex Design and Manufacturing Corporation
3333 Susan Street
Costa Mesa, California 92626 USA
declares under sole responsibility that the product:
Product Name:
OneConnect
TM
Universal Converged Network Adapter (UCNA)
Models:
OCe10101-yy-zzz, OCe10102-yy-zzz (y/z = alphanumeric or blank)
PCBA Number:
P004096-xxx (x = alphanumeric or blank)
To which this Declaration relates is in conformity with the following standards or other
documents for Information Technology Equipment (ITE):
Product Safety:UL Recognized to UL 60950-1:2007, Second Edition
CUR Recognized to CSA22.2, No. 60950-1-07
IEC 60950-1:2005, Second Edition [CB Scheme]
EN 60950-1:2006
EN 60825-1 (1994) + A1 +A2 (optical versions only)
CFR Title 21, Laser AEL Class 1, FDA/CDRH (optical versions only)
EMC: FCC Rules, CFR Title 47, Part 15, Subpart B, Class A
Industry Canada, ICES-003:2004, Class A
EN55022:2006 +A1, Class A / CISPR 22:2005 +A1 +A2, Class A
EN55024:1998 +A1 +A2
AZ/NZS CISPR22:2006, Class A
VCCI 2009-04, Class A
CNS 13438:2006 Class A, KN22 (2008-39) Class A, KN24 (2008-38)
Supplementary
Information:
1. The Product was tested in a typical configuration.
2. The product complies with the requirements of the following directives:
x
European Union Low Voltage Directive 2006/95/EC
xEuropean Union EMC Directive 2004/108/EC
xCE-Marking Directive 93/68/EEC (Carries the CE-Mark accordingly)
x
Australian EMC Framework (Carries the C-Tick mark accordingly)
August 4, 2009
Costa Mesa, CA.
James M. McCluney,
President and Chief Executive Officer
European Contact:Emulex Corporation
7 & 8 Forest Court
Oaklands Park
Fishponds Road
Wokingham, Berkshire
RG41 2FD, England
Telephone:
Fax:
44-118-977-2929
44-118-977-3237

Emulex OneConnect OCe10102 CNA Installation Manual Page 12
Laser Safety Notice
This laser safety information contains certification and product information covering laser products
known as optical small form factor transceivers incorporated in Emulex LightPulse host adapters. The
small form factor transceiver is the primary cable connection mechanism for any optical port on the host
adapter. This data is not intended to be a replacement for any safety regulations and standards; relevant
safety documents should always be consulted if necessary. Contact Emulex Corporation with any
questions or concerns about laser safety.
Certification and Classification
The OCe10102 CNA host adapters may contain one or more examples of a laser product known as a
small form factor transceiver. This transceiver provides the physical connection to the optical cable, and
its LC-style connector extends through the mounting bracket. In turn, the host adapter can be inserted
into any host system's appropriate PCIe expansion slot.
In the United States, all optical small form factor transceivers sold by Emulex are certified as Class 1
laser products that conform to the requirements contained in the Department of Health and Human
Services (DHHS) regulation 21 CFR subchapter J. The certification is indicated by a label located on the
optical small form factor transceiver.
In Europe, all optical small form factor transceivers sold by Emulex are certified as Class 1 laser
component assemblies that conform to the requirements contained in the CENELEC (European
Committee for Electrotechnical Standardization) standard EN60825-1:1994 (including amendment 11)
and EN60825-2:1994. Small form factor transceivers are certified by a recognized European testing
agency and have appropriate markings on the assembly. The DHHS conformity label and European
conformity mark will not be visible externally once the optical small form factor transceiver is connected
to or inserted in the host adapter and the adapter is installed into a system.
Labeling Requirements
No caution or danger labels are required for use of the small form factor transceiver since they are Class
1 laser component assembly. In the U.S., the only laser safety label required is the DHHS certification
label that already appears on the small form factor transceiver. In Europe, the EN60825-1/EN60825-2
standards require that the system-level product has a Class 1 information label permanently attached
and clearly visible whenever access to the GLM, GBIC, 1x9 and small form factor transceiver optical port
is possible. Each Class 1 product shall have affixed an explanatory label bearing the words:

Emulex OneConnect OCe10102 CNA Installation Manual Page 13
Alternatively, at the discretion of the manufacturer, the same statement may be included in user
information. If a label is used, an example of the IEC Class 1 information label that is suitable for most
European countries is shown below. The label consists of black printing on a white background.
Languages represented on this label are English, German, Finnish and French, and they represent the
minimum set for acceptance of a Class 1 product in most European countries.
Product Information
Small Form Factor Pluggable Transceiver
The small form factor pluggable transceiver is an integrated duplex data link for bi-directional
communications over multimode or single mode optical fiber. Each small form factor transceiver consists
of a transmitter and receiver optical subassembly. The transmitter subassembly contains a
semiconductor laser emitting in the wavelength range of 770 to 860 nanometers for small form factor
pluggable short-wavelength transceivers and 1270 to 1355 nanometers for long wavelength small form
factor pluggable transceivers. For non-OFC links, the optical power from the laser transmitter is
controlled and maintained at a lower power level. The power emitted from either an open fiber or open
laser transmitter is guaranteed to be below the Class 1 limit. Class 1 laser products are not considered
hazardous. No user maintenance, service operations or adjustments can be performed the small form
factor transceiver.
Usage Restrictions
Failure to comply with these usage restrictions may result in incorrect operation of the system and could
possible lead to points of access that may emit laser radiation levels above the Class 1 limits established
in the U. S. by the DHHS and within Europe by EN60825-1/EN60825-2.
Short wavelength and long wavelength small form factor transceivers allow normal data transmission on
the optical link when they are connected to another compatible laser product. Short wavelength and long
wavelength small form factor transceivers embedded in Emulex host adapter are non-OFC. For non-
OFC links, a compatible laser device must be non-OFC and certified as a Class 1 laser product.
Any system level product that incorporates the small form factor transceivers must provide power supply
protection that guarantees a voltage of 4.0 volts or less at the small form factor transceivers. The
functional power supply range of the small form factor transceivers product is specified as 3.135 to
3.465V typically. Operation outside of this range may degrade the performance and lifetime of the
transceiver. The transceiver will remain operational with laser emissions below Class 1 limits provided
the power supply level at the adapter remains at or below 4.0 volts. If the power supply level rises above
5.0 volts, the small form factor transceiver cannot be guaranteed to operate correctly and could result in
laser emissions that may exceed Class 1 limits.
System Level Certification
All host adapters containing embedded small form factor transceivers are certified as Class 1 laser
products within the U.S. and Class 1 laser component assemblies outside of the U.S. Manufacturers of
products properly incorporating the small form factor transceiver do not need to recertify their product for
laser safety. The procedure for full system certification is therefore identical to that used for any other
electronic system. When applying for system level certification to electronic standards such as IEC950,

Emulex OneConnect OCe10102 CNA Installation Manual Page 14
the regulatory engineers may want to see the DHHS and European conformity labeling on the small form
factor transceiver, and the system level documentation and labeling. Copies of the certificate of
conformity for any small form factor transceiver sold by Emulex can be obtained upon request from
Emulex Corporation, Costa Mesa.
Table of contents