Edge Controller INSTALLATION INSTRUCTIONS
PRODUCT SAFETY
When using electrical equipment, basic safety precautions should always be followed, including the following:
Do not mount near gas or electric heaters.
Equipment should be mounted in locations and at
heights where it will not readily be subjected to
tampering by unauthorized personnel.
The use of accessory equipment is not recommended
by Encelium as it may cause an unsafe condition.
Do not use this equipment for other than the
intended use.
The Edge Controller must be installed in dry, indoor
locations ONLY. Damp locations are defined as:
interior locations subject to moderate degrees of
moisture such as basements, barns, cold-storage
warehouses, as well as partially protected locations
under canopies, marquees and open roofed porches.
SAVE THESE INSTRUCTIONS.
READ THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.
GETTING STARTED
Overview
The Edge Controller configures and monitors the various components of the Encelium Edge standalone wireless lighting control
system. For optimum performance, the Edge Controller may be installed onto a wall or ceiling surface. Installation into plenum-rated
spaces is possible but NOT preferred.

2Edge Controller Installation Instructions
Edge Controller INSTALLATION INSTRUCTIONS
EDGE CONTROLLER
Modular Installation
The Edge Controller must be connected to the supplied Encelium Edge Controller Power Supply Unit or an Ethernet PoE network
switch using standard CAT-5 (or greater) Ethernet cabling. If a PoE network switch is not available, a PoE injector (active or passive)
may be used. Ethernet PoE network switch or PoE injector connects to the PoE port pointed by POE-IN arrow.
• The Edge Controller has been tested in accordance to UL2043 and is suitable to be used in plenum or “plenum rated” areas.
• The Edge Controller may be installed into a drop-ceiling tile (preferred installation), directly onto a wall junction box, or onto a
wall surface.
AAAAAAAAAAAAAAAA
EDGE CTRL
AAAAAAAAAAAAAAAA
EN-EC-ZB-SW
56330
6NA8
Made in Canada
FCC ID:H79DFZM-E7210
IC ID:4259B-DFZM7210
Max ambient temperature +40˚C
For Plenum Use
AAAAAAAAAAAAAAAA
MAC: 00:00:00:00:00:00
yymmdd
POE-IN
NC
POE-IN
Upgradable to
Encelium Networked LMS
Encelium Edge
Pay careful attention to the POE-IN and NC labels at the rear of the Edge Controller. The Ethernet cable from the Edge Controller
Power Supply Unit or Ethernet PoE network switch or PoE injector connects to the PoE port pointed by POE-IN arrow.
Ceiling Tile Installation
This is the preferred installation method for maximum antenna performance.
Cut a hole in the ceiling using the supplied template (the cardboard cutout holding the ceiling mount bracket in place in t
he packaging).
Assemble the Edge Controller and the ceiling mount bracket together. Push the ceiling mount bracket until the lock snaps into
the groove.
Push the assembled Edge Controller through the ceiling tile.
Place the upper bracket on to the Edge Controller (above the ceiling tile from the plenum area) until it locks with the lower bracket.
Connect the Ethernet cable to the PoE port using the POE-IN arrow point on the Edge Controller for alignment.
Ceiling Tile
Opening for EEC
installation
PoE Cable from the
SC power supply
GreenBus uses proprietary connectors and jacks for ease of installation only. GreenBus is a proprietary standard. Connect to
Encelium X Lighting Control System only. Do not connect to other circuits.
1 2 3 4

3
Edge Controller Installation Instructions
Edge Controller INSTALLATION INSTRUCTIONS
Wall Junction Box Installation
Connect the Ethernet cable to the PoE port using the POE-IN arrow point on the Edge Controller for alignment.
Install the Edge Controller onto the box screws.
Wall Surface Installation
Pre-drill two holes (3.28 inch or 83.3mm apart) on the wall using the supplied template.
Install wall plugs and the supplied screws into the pre-drilled holes.
Connect the Ethernet cable to the PoE port pointed by the POE-IN arrow on the Edge Controller.
The Edge Controller must be mounted vertically.

4Edge Controller Installation Instructions
Edge Controller INSTALLATION INSTRUCTIONS
EDGE CONTROLLER POWER SUPPLY
Top and Bottom Views
AC Line Input
PoE Cable to/from
Edge Controller
TOP VIEW BOTTOM VIEW
Junction Box Installation
Attach the Edge Controller Power Supply to a NEMA approved Junction Box.
Power Supply Wires
from Edge Controller
Power Supply Unit
AC Line
Input to
Edge Controller
Power Supply Unit
Power Supply Wires
from Edge Controller
Power Supply Unit
AC Line
Input to
Edge Controller
Power Supply Unit
Junction Box Side View Junction Box Top View

5
Edge Controller Installation Instructions
Edge Controller INSTALLATION INSTRUCTIONS
PoE Cable Installation
Attach PoE cable to the Edge Controller Power Supply.
PoE Cable to/from
Edge Controller
AC Line Input to
Edge Controller
Power Supply
Troubleshooting
There are no user-serviceable parts inside. For detailed information about how to set-up, install, use, and maintain Encelium
hardware and software, please visit: help.encelium.com
Regulatory Approval
Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under
FCC rules.
This equipment has been tested and found to comply with Industry Canada ICES-003 Issue 5 (CAN ICES-3 (A)/NMB-3(A)).
Contains FCC ID: H79DFZM-E7210
Contains IC ID: 4259B-DFZM7210
Notes: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.

encelium.com
Copyright © 2021 Digital Lumens, Incorporated. All rights reserved. Digital Lumens, the
Digital Lumens logo, We Generate Facility Wellness, SiteWorx, LightRules, Lightelligence,
Encelium, the Encelium logo, Polaris, GreenBus and any other trademark, service mark, or
tradename (collectively “the Marks”) are either trademarks or registered trademarks of
Digital Lumens, Inc. in the United States and/or other countries, or remain the property of
their respective owners that have granted Digital Lumens, Inc. the right and license to use
such Marks and/or are used herein as nominative fair use. Due to continuous improvements
and innovations, specifications may change without notice.
DOC-000442-00 Rev A 11-21
Table of contents
Other Encelium Controllers manuals