Endless Pools D90052 1218
Single EP3 Hydraulic Power Unit - Hydraulic Power Unit Wont Turn On (50Hz)
Problem Probable Causes Solutions
Hydraulic power unit WILL
NOT turn on with the
transmitter
• Heartbeat light error 3
Open float switch circuit
(3 blinks, off for 5
seconds)
• Verify hydraulic fluid level in the hydraulic power unit reservoir.
Add hydraulic fluid if necessary. Press “RESET” button on
receiver board and allow 2-3 minutes for the controller to
reboot.
• Verify the float switch connections are secured to the receiver
board (black wire to SIG –and white wire to SIG +)
• Remove the cord attached to float level switch and verify
continuity between the parallel male prongs of the float level
switch. If no continuity, replace float level switch.
• Perform factory reset of the receiver board (see factory reset
procedure on page 5)
• Replace receiver board
• Loose wiring connections • Verify Line 1, Neutral, A1, and A2 connections on both the line
side and load side of the contactor are tight.
• Verify wires in the field wiring box of electric motor are tight.
• Problem with contactor • Verify 220V on line side of contactor between Line and Neutral
wires. Press in contactor override button and verify 220V on
load side of contactor between Line and Neutral wires. If
voltage on load side of contactor is not 220V when contactor
override is pressed, replace contactor.
• Thermal overload tripped • Verify thermal overload of electric motor isn’t tripped. Reset
overload if necessary. If overload continues to trip, verify proper
ventilation or replace thermal overload.