ENERGY FOCUS nUVo TOWER User manual

TOWER
Portable Germicidal UVC
Air Purifier
Operating Manual
Energy Focus, Inc.
32000 Aurora Road Solon, Ohio 44139
800.327.7877
energyfocus.com
nUVo.us
Made in China NUVO-AT-SP EN

CONTENTS INTRODUCTION
Important Safety Instructions
Getting Started
Controls
LED Indicator Light Strip
Display
UVC Bulb Replacement
Additional Information
Troubleshooting
Warranty
2
12
12
13
14
15
17
Thank you for your
purchase of
nUVo™ Tower.
Keep this manual
accessible as you will
need it for,
troubleshooting, and
basic operation of
this device.
1

IMPORTANT
SAFETY
INSTRUCTIONS
BEFORE USING THIS
DEVICE, READ ALL
INSTRUCTIONS AND
CAUTIONARY
MARKINGS IN THIS
MANUAL AND ALSO ON
THE BASE OF THE
DEVICE.
When using any electrical device, basic
precautions should always be adhered to,
including the following:
WARNING
WARNING:
1. Ultraviolet radiation emitted from this lamp. Avoid exposure of the
eyes and skin to any unshielded source of light.
2. This nUVo™ Tower device is not intended to be used as a medical
device and is not registered as a medical device under any
applicable laws.
3. Skin or eye damage may result from directly viewing the light
produced by the lamp in this apparatus.
4. Always disconnect power before relamping or serving.
NOTE: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense. 32

IMPORTANT
SAFETY
INSTRUCTIONS
54
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY:
1. This nUVo™ Tower device is not intended
for use by persons (including children) with
reduced physical, sensory or reasoning
capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning use of
the device by a person responsible for
their safety.
2. Do not dismantle this device or use
without UVC bulb unit installed.
3. Do not allow nUVo™ Tower to be used as
a toy. Close attention is necessary when
used by or near children. Children should be
supervised to ensure that they do not play
with this device.
4. Use only as described in this Operating
Manual. Do not carry out any maintenance
other than what is shown in this manual or
advised by the Energy Focus Customer
Success Help Line at 1-800-327-7877.
5. Suitable for dry location ONLY. Do not use
nUVo™ Tower outdoors or on wet surfaces
and do not expose to water or rain.
nUVo™ Tower is not suitable for use in
bathrooms with showers or bathtubs.
6. Do not handle any part of the plug or
nUVo™ Tower device with wet hands.

76
10. Do not run cord under carpeting.
Do not cover cord with throw rugs, runners
or similar coverings. Do not route cord under
furniture or appliances. Avoid placing cord in
high traffic areas and where it could be
tripped over.
11. Do not unplug by pulling on the cord. To
unplug, grasp the plug, not the cord. The use
of an extension cord is not recommended.
12. Do not put any object into openings or
the inlet grill. Do not use with any opening
blocked; keep free of dust, lint, hair, and
anything that may reduce airflow.
13. Do not use any cleaning agents or
lubricants on this device. Dust with a clean
dry cloth. Unplug before cleaning or carrying
out any maintenance.
7. Do not operate any nUVo™ Tower device
with a damaged cord or plug. Discard the
device or return to an authorized service
facility for examination and/or repair. If the
supply cord is damaged, it must be replaced
by Energy Focus, its service agent or a
similarly qualified person in order to avoid
a hazard.
8. If the nUVo™ Tower device is not working
as it should, has received a sharp blow, has
been dropped, damaged, left outdoors, or
exposed to water, do not use.
Contact the Energy Focus Customer
Success Help Line at 1-800-327-7877.
9. Do not stretch or place the cord under
strain. Keep cord away from heated
surfaces.

98
18. For best results, the nUVo™ Tower
device should be located away from walls
and furniture. nUVo™ Tower should be
installed as centrally in the room as possible.
19. Do not tamper with safety switches or
open any part of the nUVo™ Tower device
not intended for regular maintenance.
20. Care should be taken to avoid looking
directly into fan chamber while product is
in use.
21. WARNING: This product contains
chemicals known to the state of California to
cause cancer, birth defects or other
reproductive harm.
14. Turn off all controls before unplugging.
Unplug from outlet when not in use for
extended periods. To avoid a tripping hazard,
safely coil the cord.
15. Do not use near furnaces, fireplaces,
stoves or other high temperature heat
sources.
16. Do not use in conjunction with or directly
next to an air freshener or similar products.
Keep essential oils and chemicals away from
this device.
17. Do not place or drape items on or over
device. Air path through device should
always be kept free of obstruction.

11
10
22. To reduce the risk of electric shock, this
nUVo™ Tower device has a polarized plug
(one blade is wider than the other). This plug
will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact
a qualified electrician to install the
proper outlet. Do not attempt to override this
safety feature and do not alter the plug in
any way.
23. UVC bulb should only be replaced by a
professional. Only replace lamp with Energy
Focus SKU NUVO-AT-LAMP. For more
information, please contact the Energy
Focus Customer Success Help Line
at 1-800-327-7877
READ AND SAVE THESE
INSTRUCTIONS
THIS DEVICE IS INTENDED FOR
HOUSEHOLD USE ONLY

1716
Solid Yellow Light
Flashing Red Light
Call Energy Focus
Customer Success
Help Line at
1-800-327-787
Ensure UVC safety
baffle is securely
in place
Ensure Cable is
securely connected
to nUVo™ Tower
UVC bulb
Call Energy Focus
Customer Success
Help Line at
1-800-327-7877
WARRANTY
1 Year Limited Warranty on the
nUVo™ Tower device.
1 Year Limited Warranty on the
nUVo™ Tower UVC bulb.
Visit nuvo.us for standard limited warranty
terms and conditions.
Please note that the warranty may not be
valid in case of improper installation (for
example, not turning off main power before
installation), and damage due to exceptional
operational conditions or unauthorized
modifications.

UVC bulb should only be replaced by a
professional. For more information, please
contact the Energy Focus Customer
Success Help Line at 1-800-327-7877
BULB CONTAINS MERCURY. DISPOSE
OF BULB IN ACCORDANCE WITH LOCAL
DISPOSAL LAWS
Issue
nUVo™ Tower
device doesn’t
power on.
Solution
Ensure unit is
plugged in
Confirm wall socket
has power
Call Energy Focus
Customer Success
Help Line at
1-800-327-7877
ADDITIONAL
INFORMATION
TROUBLESHOOTING
15
nUVo™ TOWER DEVICE
UVC BULB
REPLACEMENT
14

GETTING STARTED
CONTROLS
1312
Power Button: Turns the nUVo™ Tower
device on/off and activates the LED indicator
light strip.
+ : Increases fan speed (levels 1-4)
- : Decreases fan speed
To turn off LED indicator light strip press and
hold the power button for 5 seconds.
LED INDICATOR
LIGHT STRIP
DISPLAY
1 Green Light: nUVo™ Tower device is on lowest speed
2 Green Lights: nUVo™ Tower device is at level 2 speed
3 Green Lights: nUVo™ Tower device is at level 3 speed
4 Green Lights: nUVo™ Tower device is at maximum speed
Yellow Light: Recommended time to change
UVC bulb (approximately 10,000 hours of use)
UVC bulb should only be replaced by a
professional. For more information, please
contact the Energy Focus Customer Success
Help Line at 1-800-327-7877
Red Light: Error - consult troubleshooting section
This manual suits for next models
1
Table of contents
Other ENERGY FOCUS Air Cleaner manuals
Popular Air Cleaner manuals by other brands

cecotec
cecotec TOTALPURE 4000 OZONE instruction manual

Nikken
Nikken Air Wellness Power5 Pro owner's manual

COMPANION
COMPANION COMP369 instruction manual

Sanuvox
Sanuvox SRMax troubleshooting manual

Colzer
Colzer Colzer1320 user manual

American Standard
American Standard FD145ALUPGRDA Installation operation & maintenance