Enerzen 0-UVC2 User manual

Ple
a
Co
m
a
se read all
o
before
o
O-U
V
m
merc
i
OWN
E
o
f the infor
m
o
perating yo
u
V
C2 /
O
i
al Oz
o
E
R’S MA
N
m
ation provi
d
u
r new com
m
O
-UVC3
o
ne Ge
n
N
UAL
d
ed in this o
w
m
ercial ozo
n
n
erator
w
ner’s man
u
n
e generato
r
u
al
r
.

CAUTION
N
RI
S
: TO REDUC
E
NOT
N
O USER SE
R
1
CAUTIO
N
S
K OF ELEC
T
SHOCK
!
DO NOT O
P
ATTENTI
O
E
THE RISK O
F
REMOVE TH
E
R
VICEABLE P
A
N
T
RICAL
!
P
EN!
O
N
F
ELECTRIC
A
E
COVER.
A
RTS
A
RE IN
S
A
L SHOCK, D
O
S
IDE.
O

T
h
o
z
u
n
a
u
h
is commerci
z
one technol
o
n
occupied sp
u
tomobiles,
a
Model:
Rated Volta
Power Con
s
Ceramic Pl
a
(2 pieces):
HEPA filter
s
( 1 piece)
UVC light (
1
Air Volume:
Sound Lev
e
Product siz
e
Net Weight:
IN
T
al ozone ge
n
o
gy develop
e
aces. It is id
e
nd boats.
g
e:
s
umption:
a
te Size
s
ize
1
piece)
e
l:
e
:
2
T
RODU
C
n
erato
r
utiliz
e
e
d specificall
y
e
al for the tr
e
O-UV
C
Europ
e
USA/J
a
50 W
165 X
1
L173×
W
≥500
Max 1
0
45 dB
L260x
W
4.2 Kg
s
C
TION
e
s controlled
y
to reduce
o
e
atment of h
o
C
2
e
AC 220-24
0
a
pan AC 100
-
1
15mm
W
126×H15m
μw/cm2(at 1
0
0
0 CFM(2.80
W
215xH225
m
s
(9.24Lbs)
corona disc
h
o
dors and s
m
o
mes, office,
0
V/50-60Hz
-
120V/50-60
H
m
0
cm-distanc
e
M
3
/min)
m
m
harge
m
oke in
H
z
e
)

3
Model: O-UVC3
Rated Voltage: Europe AC 220-240V/50-60Hz
USA/Japan AC 100-120V/50-60Hz
Power Consumption: 50 W
Ceramic Plate Size
(3 pieces): 165 X115mm
HEPA filter size
( 1 piece) L173×W126×H15mm
UVC light (1 piece) ≥500μw/cm2(at 10cm-distance)
Air Volume: Max 100 CFM(2.80 M3/min)
Sound Level: 45 dB
Product size: L260xW215xH225mm
Net Weight: 4.3 Kgs(9.5Lbs)

Timer Con
Indicator
L
Ozone Ou
t
trol Knob -
L
ight -
t
put -
4
DIAGR
A
(Front Vi
e
Turn clock
w
maximum
d
Turn count
e
position fo
r
Illuminates
Turn clock
w
A
M
e
w)
w
ise to set t
h
d
uration of 2
e
r clockwise
r
continuous
when the u
n
w
ise to adju
s
h
e timer up t
o
4 hours
to the HOL
D
usage
n
it is on
s
t ozone out
p
o
a
D
p
ut

Ozone
P
Fuse H
o
Power
O
HEPA -
O-U
V
(B
a
P
late -
o
lde
r
-
C
e
sl
o
S
t
O
utlet - 2
2
E
u
A
pr
V
C2
5
a
ck View)
e
ramic ozon
e
o
ts on the re
a
t
ores an add
i
2
0~240 Volt
g
u
rope, 100-1
high efficien
c
essure fitted
e
plates are i
a
r of the uni
t
i
tional 2 am
p
g
rounded co
20 Volt for
U
c
y particulat
e
to the rear
o
O
nserted into
t
p
spare fuse
rd for
U
SA
e
air filter is
o
f the unit
-UVC3
the

The
spa
c
dura
cont
i
be v
e
To o
A
ozone gen
e
c
es. The unit
tion of 24
i
nuous usag
e
ntilated for
a
perate the
O
Close off th
e
Remove all
o
Position the
If you have
not vent to
o
mode.
Set the time
r
A
llow at lea
s
space.
e
rator is des
has a timer
hours, or
y
e
. Upon co
m
a
t least 1 ho
u
O
zone Gener
a
e
desired are
o
ccupants a
n
unit as clos
e
a personal
h
o
ccupied sp
a
r
to duration
s
t 1 hou
r
of v
e
6
igned to re
m
t
hat will ena
b
y
ou can us
e
m
pletion of t
r
ur
prior to re
t
a
tor Air Puri
f
a to be treat
e
n
d pets.
e
as possible
h
eating and
c
ces, then tu
r
and leave th
e
ntilation be
f
m
ove odors
b
le it to run f
o
e
the HOL
D
r
eatment, th
e
t
urning to th
e
f
ier:
e
d.
to the odor
s
c
ooling syst
e
r
n the A/C o
n
e room.
f
ore re-enter
i
in unoccupi
e
o
r a maximu
D
function f
o
e
area shou
e
treated are
s
ource.
e
ms that do
e
n
to circulati
o
i
ng the treat
e
e
d
m
f
or
u
ld
a.
e
s
o
n
e
d

A
When the o
z
effective, th
e
recommend
e
To clean th
e
ceramic plat
e
mesh and c
e
Scrubbing
w
A
liquid clea
remove any
and dry com
the plate qui
The HEPA
f
environmen
t
months.
z
one genera
t
e
ozone plat
e
e
d to clean t
h
plates, turn
e
s out of slo
t
e
ramic plate
s
w
ith a stiff bru
n
er containi
n
non-visible
a
pletely befo
r
cke
r
. Be car
e
f
ilter replace
m
t
and shoul
d
7
t
o
r
no longer
e
s should be
h
e plates ev
e
the unit off
a
t
s in rear of
u
s
using a spr
a
sh will help t
o
n
g ammonia
a
dherents. R
i
r
e reinstallin
g
e
ful not to dr
m
ent interv
a
d
be replace
produces e
n
cleaned or r
e
ry two mon
t
a
nd unplug fr
u
nit. Wash t
h
a
y cleaner o
r
o
clean the i
n
or chlorine
m
i
nse plate th
o
g
. A hair dry
e
op the cera
m
a
l is depend
e
d when vis
u
n
ough ozone
e
placed. It i
s
t
hs.
o
m outlet. N
e
h
e stainless
s
r
detergent.
n
sides of th
e
m
ay also be
u
o
roughly in
h
e
r may be us
e
m
ic plate.
e
nt upon its
u
ally dirty or
e
to be
s
e
xt, pull
s
teel
e
screens.
u
sed to
h
ot water
e
d to dry
working
every 3

If yo
u
•Uni
t
•Cer
a
•Th
e
•It’s
i
pote
n
•Fus
the
p
Repl
Ca
u
u
suspect a
p
t
is plugged i
a
mic plates
a
e
re are no cr
a
i
mportant th
a
ntial shock.
e is installed
p
lastic fuse h
acement fu
s
u
tion: Do no
t
serviceable
p
roblem with
n properly.
a
re clean an
d
a
cks in plate
s
a
t the ozone
properly an
d
older, remo
v
s
e must be 2
t
remove a p
a
parts. Op
e
8
your unit, t
h
d
dry.
s
and each
p
generator b
e
d
in not brok
e
v
e old fuse,
a
amp (0.79 i
n
a
nel of the c
a
e
ning the uni
t
h
en check th
e
p
late is flush
w
e
properly gr
o
e
n. To repla
c
a
nd insert ne
w
n
ch). Refer t
o
a
binet, as th
e
t
will void all
e
following:
w
ith back of
o
unded to a
v
c
e fuse, pull
w
fuse.
o
pictures be
e
re are no u
s
warranties.
unit.
v
oid
out
low:
s
er

9
WARRANTY INFORMATION
OION Technologies, LLC (collectively “OION”) warrants from the date of purchase, this product will be free from
defects in material and workmanship. Please refer to your retailer’s product sales page for the duration of the
warranty period. OION, at its option, will repair or replace this product or any component of the product found to
be defective during the warranty period. Replacement will be made with a new or remanufactured product or
component. If the product is no longer available, replacement may be made with a similar product of equal or
greater value. This is your exclusive warranty. Do NOT attempt to repair or adjust any electrical or mechanical
functions on this product. Doing so will void this warranty. This warranty is valid for the original retail
purchaser from the date of initial retail purchase and is not transferable. Proof of purchase is required to obtain
warranty performance. This warranty does not cover normal wear of parts or damage resulting from any of the
following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the
operation instructions, disassembly, repair or alteration by anyone other than an OION authorized service
technician or OION service center. Additionally, the warranty does not cover: Acts of God, such as fire, flood,
hurricanes, earthquakes and tornadoes.
OION shall not be liable for any incidental or consequential damages caused by breach of any express, implied
or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or
condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above
warranty. OION disclaims all other warranties, conditions or representations, express, implied, statutory or
otherwise. OION shall not be liable for any damages of any kind resulting from the purchase, use or misuse of,
or inability to use the product including incidental, special, consequential or similar damages or loss of profits, or
for any breach of contract, fundamental or otherwise, or for any claim brought against purchaser by any other
party. Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty lasts, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary
from province to province, state to state or jurisdiction to jurisdiction. To obtain warranty service, please contact
us at customerserv[email protected].
This manual suits for next models
1
Table of contents
Popular Laboratory Equipment manuals by other brands

Coralife
Coralife TurboTwist Series instructions

Adam Equipment
Adam Equipment ANTI-VIBRATION TABLE Assembly instruction

Thermo Scientific
Thermo Scientific Sorvall Legend X1 instruction manual

Daihan Scientific
Daihan Scientific HB-R48 Operation manual

Pasco Scientific
Pasco Scientific ME-6956 Instruction manual and experiment guide

Thermo Scientific
Thermo Scientific Thermo Scientific Orion Star T900 Series user manual