ENFORCER FIREBULL 200 User manual

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 1
Operation and Maintenance Manual

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 2
Table of Contents
Chapter 1 Page
-Product Introduction 3
-Product Warranty 3-4
-Safe Operating Procedures 5-6
Chapter 2 Page
-System Description 7
-System Specifications 7
Chapter 3 Page
-Set Up 8
-Preventative Maintenance Checks and Services 9
-Operating Instructions 10-11
Chapter 4 Page
-Training 12
Chapter 5 Page
-Maintenance 13-16
-Servicing and Maintenance Activities 17-18
-Troubleshooting 18-19
Chapter 6 Page
-Pictures 20-21

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 3
CAUTION: User should read and follow all Safety Rules and
Operating Instructions BEFORE first use of this product!
Chapter 1
Introduction
1-1. Manufacturer
a. The Enforcer 200 is Manufactured by:
Enforcer One, LLC
473 Dividend Drive
Peachtree City, GA 30269
United States of America
Phone: 770.460.7793
Fax: 678.604.0107
E-mail: Info@enforcerone.com
Website: www.enforcerone.com
b. Enforcer One, LLC is committed to the satisfaction of our owners and operators of
the Enforcer 200. If you have any problems, questions, or concerns please contact
Enforcer One, LLC via phone, Fax, or E-mail.
1-2. Warranty
Limited Warranty
Fire Service Plus, Inc. warrants to the original owner-user that Enforcer One, LLC line of
Compressed Air Foam products will be free from failures due to defects in workmanship for a
period of one year from the date of original purchase. During the warranty period, Enforcer One,
LLC , at its sole discretion, will repair or replace at no charge, the product that, in its sole opinion, is
defective.
The purchaser is responsible for packing the product for shipment and for charges to ship the
product to the location specified by Enforcer One, LLC, including, at the purchaser’s sole discretion,
insurance on the shipment. Enforcer One, LLC will return the product pre-paid to the purchaser.
If the product has been altered, modified or repaired in any way, or if the failure is the result of
misuse, abuse or misapplication without the prior consent of Enforcer One, LLC, this warranty shall
be void and Enforcer One, LLC shall have no obligation to repair or replace the failed product.
The use of any foam product other than FIREBULL® Fluorine Free Foam products will void the
warranty.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 4
CAUTION: The unpredictable nature of fires, the techniques used to apply
product(s) as well as the knowledge-understanding and judgment of the
individual(s) attempting to extinguish or control them will affect the performance
of Enforcer One, LLC product(s).
CAUTION: Prior to attempting to operate this or any Enforcer One, LLC product, you
MUST read and understand all directions and instructions in this user manual. Until
you have read and understand all CAUTIONS; Warnings, Requirements, Instructions
for Set-up & Testing - Operation and Maintenance: NO ATTEMPT should be made to
operate this or any Enforcer One, LLC product. In order to assure that your Enforcer
One, LLC product(s) are ready when needed, they must be regularly maintained as
outlined. FAILURE TO COMPLY WITH ALL CAUTIONS, WARNINGS, REQUIREMENTS,
INSTRUCTIONS, PROCEDURES AND MAINTENANCE WILL VOID THIS WARRANTY &
MAY RESULT IN SERIOUS INJURY OR DEATH &/OR DAMAGE TO OR LOSS OF
PROPERTY.
Warranty – continued
When used in conjunction with sound fire management practices and strictly as per the
manufacturer’s instructions, the products may provide protection against anticipated fires and
may accelerate the extinguishing of existing fires.
THIS WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY FOR ENFORCER ONE, LLC LINE OF
PRODUCT(S) AND DISCLAIMS AND EXCLUDES ANY AND ALL IMPLIED WARRANTIES REGARDING
THE PRODUCT(S) INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
No person or entity is authorized to bind Enforcer One, LLC to any other warranty obligation or
liability to distributer, purchaser or any third party for any loss of profits, economic loss,
indirect, incidental, punitive, special or consequential damages whatsoever and howsoever
caused. Operation or use of this or any Enforcer One, LLC product for which this warranty is
issued shall constitute acceptance of the terms hereof.
SAFE OPERATING REQUIREMENTS
1. DO NOT attempt to use this or any Enforcer One, LLC line of product(s) if they appear
damaged and/or broken. Missing or damaged components MUST be properly repaired or
replaced as soon as possible.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 5
Safe Operating Requirements – continued
2. DO NOT attempt to use this or any Enforcer One, LLC line of product(s) if you are tired,
injured or under the influence of drugs, medication or alcohol.
3. DO keep children and bystanders away from the area when Enforcer One, LLC product(s)
are in-use.
4. DO NOT attempt to use this or any Enforcer One, LLC line of product(s) in the event that the
fire represents a situation that is beyond the capabilities of the Operator and/or the
Equipment.
5. DO follow the proper Set-up, Testing, and Maintenance & Inspection Procedures to assure
that your Enforcer One, LLC line of product(s) is/are ready for use when needed.
6. DO exit the area IMMEDIATELY if progress in fighting the fire is not being made and DO NOT
return to the area.
7. DO comply with all local Laws & Regulations related to the proper use, installation,
maintenance, training and inspection of Fire-Fighting Equipment.
WARNING: The act of fighting fire is both hot and dangerous work. Smoke, heat,
unseen fumes/gases and flames can be easily underestimated. In the absence of the
proper training, protective gear and clothing, extreme caution should be exercised to
avoid serious injury or death. If ever, in an attempt to extinguish a fire, you are
unsure that progress is being made, contain the fire (if possible) and move quickly and
safely away from the threat.
.
1-3. Manual Changes
1. Enforcer One, LLC will provide equipment update changes to this manual on an
as need basis.
2. This manual supersedes all previous Operating Instructions for the Enforcer 200
system.
ADDITIONAL INFORMATION
http://www/usfa.fema.gov/safety/sheets.htm
http://www.nfpa.org/education/index.html
http://www.ilpi.com/safety/extinguishers.html
http://www.EnforcerOne.com

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 6
Chapter 2
System Description
2-1. General Information
The Enforcer 200 Compressed Air Foam System utilizes compressed air to propel
firefighting foam. Enforcer 200 produces air aspirated foam providing a thick vapor
sealing blanket that will inhibit re-ignition. The Enforcer 200 will produce up to 4000
gallons of finished foam with discharge duration of up to 20 minutes. The system can be
easily recharged by the end user.
2-2. Model Configuration
The Enforcer 200 consists of a Premix Tank which holds 200 gallons of pre-mixed
FIREBULL® Fluorine Free Foam. Two compressed air cylinders are attached to the
Premix Tank through a regulator and hose assembly. Discharge hose include one 300’
section of 1” Booster Hose on a hose reel with pistol grip style nozzle. Enforcer 200 also
includes one 50’ section of 1.5” lay flat hose with pistol grip style nozzle. The Enforcer
200 can discharge both hoses simultaneously.
2-3. Specifications
-Height: 39 “ (99 cm) Length:97 ” (246 cm) Width: 44 ” ( 112cm.)
-Empty Weight: 2000 lbs. (998 kg) Loaded Weight: 3200 lbs. (1360 kg)
-Premix Tank: 200 US Gallons (757 l)
-Finished Foam Capacity: 4000 US Gallons (13,514 l)
-Foam Discharge Distance: Up to 95 Feet ( 29 m)
-Air Cylinders: 300 cu. ft. 2400 psi (165.5 bar)
-Recharge Time: 20 minutes
2-4. Transporting
The Enforcer 200 should be secured when transporting in trailers or vehicles.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 7
Chapter 3
Operating Instructions
3-1. Initial Setup
The Enforcer 200 comes fully assembled. The 200-gallon Premix Tank and Compressed
Air Cylinder must be filled prior to use. The proper FIREBULL® Fluorine Free Foam
product should be selected based on operational ambient temperatures and type of
anticipated fires before putting the unit into service.
3-2. FIREBULL® Fluorine Free Foam Products
a. Enforcer 3 Backpack should only be used with FIREBULL® Fluorine Free Foam
products mixed at a 1%, 3% or 6% solution for low, medium and high expansion.
b. It is recommended that a FIREBULL® Freeze Protected Fluorine Free Foam Product
be used when positioning the unit outside during extended subfreezing weather.
3-3. System Depressurization
Ensure the system is depressurized before conducting maintenance
a. Close the Air Cylinder Valves.
b. Open nozzle until all Nitrogen is deployed and working pressure gauge reads zero or
open Pressure Relief Valve.
3-4. Preventative Maintenance Checks & Services (PMCS)
a. It is recommended that the PMCS CHECKLIST be completed every month.
b. Personnel conducting the PMCS should be thoroughly familiar with the Enforcer 200
system and the information contained in this manual.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 8
Preventative Maintenance Checks and Services (PMCS)
Checklist
Date Completed
Name Signature
1. Conduct a visual inspection of the system for chaffing or loose hose(s), dirt,
corrosion or damage.
2. Check the Air Cylinder for normal operating pressure (1800-2200 psi).
a. Ensure System is depressurized.
b. Disconnect Air Cylinders and pull out of unit.
c. Connect Air Cylinder Pressure Check Gauge.
d. Open Air Cylinder and check for normal operating pressure. (1800-
2200psi)
e. Close Air Cylinder and slowly disconnect Pressure Check Gauge allowing
for pressure bleed off.
f. If the Air Cylinder pressure is below 1500 psi remove, recharge and
replace the Air Cylinder.
The Air Cylinder should normally be left in the closed position.
______ 3. Check the Premix Tank Level
a. Disconnect fill tower Cap check liquid level.
b. Fill up the Premix Tank if low.
_______ 4. Check the tire condition.
Note any other Problems:

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 9
3-5. Operating Instructions
Warning
Always refer to the product MSDS for proper precautions and treatment(s) if foam is
accidently ingested or sprayed in eyes, mouth or nose
a. Turn the Regulator to zero, so no air can pass through it.Slowly open both Air
Cylinders. Turn the Regulator up to chosen operating pressure between (150 psi-
175 psi) allowing the Premix Tank to fill with compressed air. (Some Models are
factory set to 150 psi)
b. Extend one or both hoses that will be used for discharge. Ensure the Nozzle ball
valve is in the closed position.
c. Open the Foam Discharge Valve for the selected discharge hose slowly to the fully
open position.
d. Grasp the nozzle with hand.
e. Aim the nozzle at the base of the fire and open valve to discharge foam.
3-6. Cold Weather Operations
a. It is recommended that a FIREBULL® Fluorine Free Foam Pre-Mix product is used
when freezing is anticipated.
3-7. Emergency Procedures
a. Loose Hose
1. Go to the unit and close the Foam Discharge Valve.
2. Go to the Nozzle and close the valve.
b. No Foam Discharge
1. Check to see if Air Cylinder is full.
2. Verify the Air Cylinder Valve is turned completely on.
3. Ensure Air Pressure Hose is attached to the Air Cylinder properly.
4. Ensure the Regulator is on the correct operating pressure.
5. Check for obstruction in discharge hose.
c. Shut Down Procedures
1. Close the Nozzle Valve.
2. Close the Foam Discharge Valve.
3. Close the Air Cylinder Valve.
4. Open Nozzle valve to depressurize the hose line.
5. Open the Depressurizing Valve to depressurize the Premix Tank.
6. Secure discharge hose.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 10
Chapter 4
Training
4-1. Training Program
a. Training on the Enforcer 200 should be conducted or reviewed annually for all
operators
b. Maintenance personnel should complete initial training and refresher training as
required
c. Trainers should be thoroughly familiar with the system, fire behavior, hazard
identification, and basic firefighting techniques
d. Operator training should be accomplished in live fire scenarios. Live fire training can
often be accomplished through coordination with a local fire department.
4-2. Training Program of Instructions
a. Operators and Maintenance Personnel
1. PMCS
2. Normal and Cold Weather Operating Instructions
3. Emergency Procedures
4. Operation in live fire scenario
b. Maintenance Personnel
1. General Maintenance
2. Instructions and Technical Assistance
3. Foam Product
4. Maintenance Log
5. Servicing Under Normal and Cold Conditions
6. Scheduled Maintenance
7. Unscheduled Maintenance
8. Troubleshooting Procedures
9. Storage and Protection

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 11
Chapter 5
Maintenance
5.1 General Instructions
a. It is recommended that the preventative and maintenance (PMCS) be
conducted monthly.
b. It is recommended that qualified personnel be assigned the responsibility to
service and maintain the system
a. All maintenance activity should be documented and should include copies of the
completed PMCS Checklist, Premix Tank Filling Calendar, type/ ratio of product used,
component changes and any other problems encountered. A MSDS should be
maintained for the type of foam being used.
5-2. Technical Assistance
Maintenance personnel should contact Enforcer One whenever any problem arises that
cannot be solved using the information in this manual or when unusual situations are
encountered or expected.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 12
Enforcer 200 Maintenance Log
Preventative Maintenance Checks and Services (PMCS)
Refer to Chapter 5 – Maintenance for specific activities
Maintenance
Activity
Date
Completed
Performed By
Notes/Comments

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 13
Scheduled Maintenance
Maintenance
Activity
Recommended
Interval
Date Due
Date
Completed
Performed By:
Air Cylinder
Pressure Check
Every 6 months
Air Cylinder –
Visual Inspection
Annually
Air Regulator
Inspection
Every 2 years
Air Cylinder
Hydrostatic Test
Every 5 Years
Premix Cylinder
and Discharge
Hose Hydrostatic
Test
Every 5 Years

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 14
Unscheduled Maintenance
Maintenance Activity
Date
Completed
Performed
By
Comments/Notes

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 15
5-3. Servicing Under Normal Conditions
a. System Pressure Check
1. Make sure that the Fill Tower Cap is secure,the Foam Discharge Valves and
Pressure Relief Valve are closed.
2. Turn the Regulator to Zero.
3. Open the Air Cylinder Valves. Turn the Regulator to 150 psi and check the air
pressure on the High Pressure Gauge for normal operating pressure of 2200-
2400psi.
4. Check the Working Pressure Gauge is in the normal operating position 150psi.
5. Conduct a leak check if the High Pressure Gauge reads below 1500 psi or if the
Working Pressure Gauge reads below 150 psi.
a. Spray a soap solution on all airlines/fittings.
b. Tighten leaking fittings, replace O-rings, or replace defective components.
5. Bleed off any stored pressure through Pressure Relief Valve.
b. Changing and Servicing Air Cylinder
Ensure the system is depressurized before conducting any maintenance
on the system. Extreme care should be used when transporting the Air
Cylinder(s).
1. Ensure Air Cylinder Valves are closed
2. Depressurize the system
3. Lift out the Air Cylinders
4. Have the Air Cylinders filled to 2400 psi by a certified technician
5. Replace the Air Cylinders in the holder
6. Reconnect the Air Cylinders
d. Refilling the Premix Tank
1. Close the Air Cylinder Valve
2. Ensure System is depressurized
3. Unscrew Fill Cap
4. Add water until Premix Tank is full
5. Add appropriate amount of foam to an empty pail or drum
6. Add the water to the foam and mix to thin the concentrate
7. Using a long spout funnel add the thinned concentrate to the unit (Ensure the
funnel extends to the lower portion of the tank, the concentrate solution will push
the clear water out of the top ensuring a perfect fill)
8. Replace Fill Cap ensuring it is tightened properly
9. Important Note: The Premix Tank Manifold should be tightened by hand. Do not
use any wrenches or Teflon tape or thread sealant on any of the Premix tank
fittings.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 16
5-4. Servicing In Cold or Freezing Conditions
Fill the Premix Tank with FIREBULL® Fluorine Free Foam solution whenever
temperatures are below 32 degrees Fahrenheit. FIREBULL® should be used in the
concentrate form in cold or freezing temperature conditions. FIREBULL® Fluorine Free
Foam is a solution made by Enforcer One, LLC. The Pre-Mix solution is already mixed,
this means Water and Foam, no need for mixing onsite. Maintenance personal should
open the Pre-Mix bucket and fill the Enforcer unit full of the Pre-Mix solution.
5-5. Scheduled Maintenance Interval Recommendations
Component
Maintenance Activity and Recommended Interval
Air Cylinder
•Check pressure - every 6 months
•Visual inspection and certification – annually
•Hydrostatic testing – every 5 years
Cleaning
•Wash with soap and water – minimum annually
Air Regulator
•Check Operation – every 2 years
Premix Tank
&
Discharge Hose
•Pressurize and check for leaks – annually
•Hydrostatic testing should be completed every 5 years
Foam Solution
•Follow Foam Manufacturer quality testing recommendations
5-6. Unscheduled Maintenance
Unscheduled maintenance will need to be performed as required.
5-7. Trouble Shooting the System
Users should contact Enforcer One if malfunctions cannot be corrected after employing
good troubleshooting practices. Use the matrix on page 17 for assistance.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 17
Trouble Shooting Matrix
Problem or Symptom
Possible Solution
No Pressure on Gauges
•Air Cylinder Valve is not turned on
•Air Cylinder is empty
•Pressure Gauge is inoperative
•Broken or blocked air hose
•
Air Regulator has malfunctioned
Foam Does Not Discharge
From Hose
•Premix Tank is empty
•Air Cylinder is empty
•Air Cylinder is not turned on
•Nozzle is in the off position
•Nozzle valve has malfunctioned
•Blockage on dispensing hose
•Foam solution is frozen
Air line Leak
•Air hose fittings are loose or broken
•Air line is pinched, cracked or
broken
System is Not Fully Discharging
•There is insufficient volume of air in
the Air Cylinder
•The Foam Discharge Nozzle is not
fully opening
•The Foam Discharge Hose has a
restriction
•The Air Regulator has a malfunction
•The Foam solution is frozen or near
freezing
•There is a blockage in the Premix
Tank
5-8. Storage and Protection
a. The Enforcer 200 does not have any special storage requirements if stored inside.
b. A protective cover is recommended and should be used if the equipment is stored
outside as this will reduce sun damage to hoses and gauges.

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 18
Chapter 6
6-1. Pictures

Enforcer One, LLC FIREBULL®is a registered trademark of Enforcer One, LLC
Copyright 2020 Page 19
This manual suits for next models
1
Table of contents
Other ENFORCER Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Twiflex
Twiflex GMR-H quick start guide

SCHUNK
SCHUNK NSE mini 90 Assembly and operating manual

Siemens
Siemens SIMATIC S7 300 PLC Getting started

ABB
ABB HT607553 Operation manual

Afag
Afag SG-50 Assembly and operating instructions manual

Jerguson
Jerguson LUMASTAR EPL-100 Installation, operation & maintenance instructions