ENFORCER SK-910RB2Q User manual

Installation Manual
Two-Channel RF Receiver
The SK-910RB2Q is a two-channel receiver that meets the growing demand for a multichannel receiver with multiple and
independently controlled output modes. This RF receiver is compatible with both code hopping and fixed code transmitters
(see page 4 of this manual for a list of compatible transmitters). The receiver can be used to control a variety of home
automation devices such as garage door openers, lights, motorized gates, lifts, or other devices remotely.
1. Mount the receiver out of sight in a location where it is not exposed to the weather or moisture, and where it is not
surrounded by metal. Metal will block the RF signal, resulting in a reduced range.
2. For best range, pull the antenna wire as long and straight as possible. If the receiver receives interference from local RF
activity (e.g., an airport or military base), the antenna wire can be folded. DO NOT CUT THE ANTENNA WIRE.
Installation Notes:
Introduction:
SK-910RB2Q (315MHz)
SK-910RB2-4Q (433.92MHz)
Flexible operating voltage: 11~24 VAC/VDC
Up to 500ft (152m) range
Independently programmable channels
Also Available from SECO-LARM:
Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.
This manual covers only two-channel receivers. For information on one- and four- channel receivers, please contact SECO-LARM.
*Operates on 11~24 VAC/VDC.
SK-910RQ.................................................................. One-channel receiver, 315MHz
SK-910RLQ ...........................................Low-voltage, one-channel receiver, 315MHz
SK-910RVQ ......................................................... Low-voltage, one-channel receiver,
transistor ground output 315MHZ
SK-910R-4Q ......................................................... One-channel receiver, 433.92MHz
SK-910RL-4Q ...................................Low-voltage, one-channel receiver, 433.92MHz
SK-910RV-4Q...................................................... Low-voltage, one-channel receiver,
transistor ground output, 433.92MHz
*
*

ENFORCER Two-Channel RF Receiver
2SECO-LARM U.S.A., Inc.
Both receiver channels can be programmed for one of five different modes, and each individual channel may operate at a
different output mode, depending on the user’s application. The five modes are:
1. 4-Second Timed Output –Press the transmitter button once. The output relay will turn ON for 4 seconds.
2. Toggle Output –Works much like a toggle switch to turn a device ON & OFF alternately. Press the transmitter button
once, and the relay turns ON. Press the transmitter button again, and the relay turns OFF.
3. Latch Output –Press the transmitter button once, and the relay turns ON and stays ON. The relay will remain ON until
the appropriate channel’s transmitter programming button is pressed once to reset, regardless of whether a compatible
transmitter button is pressed again or not.
4. Validity Output –The channel will turn the relay ON for as long as the transmitter button is pressed.
Note: Due to possible interference or drops in transmitter battery power while the transmitter button is continuously
pressed (even for short periods of time), the receiver may lose the transmitter’s signal and turn the relay OFF.
5. 1-Second Timed Output (default) –Press the transmitter button once. The relay will turn ON for 1 second.
1. Press the transmitter programming button of the desired channel to be programmed for 3 seconds or more. The
channel’s LED will start to flash quickly to indicate that it is in the learning mode.
2. While the LED is flashing, press the button of the transmitter to be learned once. The LED will flash once to indicate a
successful learning of that button’s code. After the button has been learned, the receiver will automatically exit the
learning mode. Repeat step 1 to re-enter the learning mode.
NOTE:
The transmitter programming buttons can be found at the rear of the receiver’s case. Button #1 is the transmitter
programming button for channel 1, and button #2 is the transmitter programming button for channel 2.
The channel’s LED will flash a maximum of 15 seconds. If no transmitter button is pressed during this time, the receiver
will exit the code-learning mode, and the LED will turn off.
If the code being learned has already been learned, the LED for the channel which learned the code will turn steady ON
and then start flashing again. The code will not be learned a second time.
Each channel can learn the codes of a maximum of 15 transmitter buttons. If you attempt to learn a sixteenth transmitter
code, the earliest code will be deleted.
Code Learning a New Transmitter Button:
Each receiver channel can learn the codes of up to 15 different transmitters on a first-in, first-out basis. Below is the
procedure for code learning a new transmitter button. The same procedure applies to both of the receiver’s channels.
Clear Channel Memory:
To clear all codes in the channel’s memory, press the transmitter programming button for that channel for 3 seconds or
more until the LED flashes. Release, and then press that button again for 3 seconds or more until the LED stops flashing.
The LED will then flash twice to indicate that all codes associated with that channel have been deleted.
Display Channel Memory:
To see how many codes have been learned in a channel, press that channel’s transmitter programming button once. The
number of codes stored in the channel’s memory is equal to the number of LED flashes.
Programming Each Channel Relay Output Mode:
Hold down the channel’s mode button for 3 or more
seconds to program a channel’s output mode. That
channel’s LED will flash a number of times equal to
the output mode that it is in.
To change modes, press the desired channel’s
mode button. Each press moves to the next mode in
the sequence shown in the diagram to the right.
After changing modes, count the number of times
the channel LED flashes to verify the channel is in
the correct mode.
The programming procedure for both channels is
the same.
To exit programming, hold the appropriate mode
button for 3 seconds or wait 15 seconds.
Note: For a diagram of the PC board, including the location
of the mode buttons, please see Overview, page 3.
Toggle Output
(2 flashes)
Validity Output
(4 flashes)
4-sec Timed Output
(1 flash)
Latch Output
(3 flashes)
1-sec Timed Output - default
(5 flashes)

ENFORCER Two-Channel RF Receiver
SECO-LARM U.S.A., Inc. 3
Transmitter Programming Button Operation (One per Channel):
LED Indication (One per Channel):
Extended Range Antenna (Optional):
Extends RF receiver range up to 1,000ft (304m) (open air) with
existing remotes.
Comes with a 9ft cable that easily plugs into the 3-pin antenna port
located on the RF receiver.
Note:
If an extended range antenna is used, the ―LP3‖ on the receiver PC
board must be cut.
Actual antenna range will vary greatly depending on the operating
environment.
SK-91ERSDQ
Overview:
(PC Board shown. Remove the front cover of the receiver to access the mode buttons and terminal block.)
Learn mode
Press and hold the transmitter programming button for three seconds or more.
Clear memory
Press and hold the transmitter programming button for three seconds or more, then when the
LED starts flashing, press again for three seconds to delete all previously learned codes.
Reset latched output
If this channel was programmed for latch output, once the relay is turned ON with a transmitter
button, press the transmitter programming button of that channel once to turn the relay OFF.
Memory Display
Press and release the transmitter programming button to show the number of codes stored. The
LED will flash a number of times corresponding to the number of codes stored.
Steady ON
Senses signal from a transmitter button in normal operation, or indicates a transmitter button’s
code already exists in the receiver’s memory during code learning.
Fast flash
In the code-learning mode or channel memory display mode, or during the programming channel
output mode.
One flash
A transmitter button code was learned, or the relay is in the 4-second timed output mode.
Two flashes
All previously learned transmitter buttons were deleted, or the relay is in toggle
output mode.
Three flashes
Latched output.
Four flashes
Validity output.
Five flashes
The relay is in the 1-second timed output mode.
0~15 flashes
In the normal operation mode, pressing the channel mode button once will display the number of
codes learned.
CH 1
CH 2
Brown mode button is for
channel 1 programming.
Red mode button is for
channel 2 programming.
Channel Mode Buttons
Ch 1 status LED
Ch 2 status LED
Power input
Ch 1 relay
N.O.
N.C.
COM
N.O.
N.C.
COM
Ch 2 relay
+
—
3-Pin antenna port
LP3 antenna program
loop
Transmitter programming button #2
Transmitter programming button #1

ENFORCER Two-Channel RF Receiver
4SECO-LARM U.S.A., Inc.
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of
one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to
SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair,
or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not
operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the
purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable
for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is
one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or
typographical errors.
Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the
written permission of SECO-LARM.
SECO-LARM U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
MiSK-910RB2Q_1009.docx
PITSW1
Operating frequency
SK-910RB2Q
315MHz
SK-910RB2-4Q
433.92MHz
Memory capacity
15 transmitter button codes per channel, 30 per receiver
Operating voltage
11~24 VAC/VDC
Operating current
Standby
8mA@12VDC
Active
30mA@12VDC per channel
Relay contact rating
Form C 10A@24VDC or 120VAC per channel
Connectors
Screw terminals, +, -, with NO/NC/COM per channel
Dimensions
31/8‖x29/16‖x1‖ (80x65x25mm)
Sample Applications:
Specifications:
Compatible Transmitters:
315MHz
433.92MHz
Fixed Code: 68 billion codes
SK-919 Series Fixed Code
SK-939 Series Fixed Code
CODEBUMP: 18 quintillion (1.8x1019) codes
SK-917 Series CODEBUMP
SK-937 Series CODEBUMP
Positive Output
COM
NC
NO
—
+
Positive Power Source
Positive Power Output
Power for SK-910RB2Q
Negative Output
N.C. Application with Independent Power Sources
DC Power
Source
COM
NC
NO
—
+
AC Power
Source
N.O. Application with Independent Power Sources
COM
NC
NO
—
+
Typical N.C. Application
COM
NC
NO
—
+
E-941SA-1200
Electromagnetic Lock
Typical N.O. Application
SD-996C-NUQ
Electric Door Strike
DC Power
Source
AC Power
Source
E-941SA-1200
Electromagnetic Lock
SD-996C-NUQ
Electric Door Strike
COM
NC
NO
—
+
COM
NC
NO
—
+
Negative Power Source
Negative Power Output
Power for SK-910RB2Q
This manual suits for next models
1
Table of contents
Other ENFORCER Receiver manuals

ENFORCER
ENFORCER SK-910RD4 User manual

ENFORCER
ENFORCER SK-910RAQ User manual

ENFORCER
ENFORCER MVE-SV010Q User manual

ENFORCER
ENFORCER SK-910RA SERIES Operating and maintenance instructions

ENFORCER
ENFORCER SK-910RBQ User manual

ENFORCER
ENFORCER ENFORCER SK-910RC4Q User manual

ENFORCER
ENFORCER SK-910RQ User manual

ENFORCER
ENFORCER SD-8202GT-PEQ User manual

ENFORCER
ENFORCER SK-939TP2AQ User manual