Englander BLUE RIDGE 300 P User manual

READ AND KEEP THIS MANUAL FOR REFERENCE
Printed in Canada 46322_IA
BLUE RIDGE
300 P & L
(ESW0007 and ESW0008 models)
Wood Stove
Owner's Manual
Part 2 of 2
INSTALLATION AND OPERATION
REQUIREMENTS
MOBILE
HOME
Safety tested according to ULC S627,
UL 1482 and UL 737 standards by an
accredited laboratory.
US Environmental Protection Agency
phase II certified wood stove compliant
with 2020 cord wood standard
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS
IN LOCAL AREA.
READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD STOVE. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
ENGLISH
2023-02-24

ONLINE WARRANTY REGISTRATION
If the unit requires repairs during the warranty period, proof of purchase must be provided.
The purchase invoice must be kept. The date indicated on it establishes the warranty period.
If it can not be provided, the warranty period will be determined by the date of manufacture of the
product. It is also highly recommended to register the warranty online at
https://www.englander-stoves.com/ca/en/warranty-registration/
Registering the warranty will help to quickly find the information needed on the unit.
Dealer:
Installer:
Phone Number:
Serial Number:

Page 3
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
TABLE OF CONTENTS
1. CERTIFICATION PLATE .......................................................................................................... 4
2. General Information ................................................................................................................ 6
2.1 Performances..................................................................................................................... 6
2.2 Specifications..................................................................................................................... 7
2.3 Dimensions ........................................................................................................................ 8
2.4 EPA Loading .....................................................................................................................12
3. Clearances to Combustible Material.................................................................................... 13
3.1 Clearances........................................................................................................................13
4. Floor Protection .................................................................................................................... 20
5. Reducing Wall and Ceiling Clearances Safely .................................................................... 21
5.1 Shield Construction Rules ..................................................................................................21
6. Installation of options on your product................................................................................ 24
6.1 Optional Fresh Air Intake Kit Installation ..............................................................................24
6.2 Optional Fire Screen Installation ........................................................................................25
6.3 Optional Blower And Thermodisc Installation.......................................................................26
6.4 Air Tubes And Baffle Installation..........................................................................................27
6.5 Log retainers installation ....................................................................................................29
6.6 Mobile Home Installation ....................................................................................................30
7. Maintenance/Parts Replacement......................................................................................... 31
7.1 Replacement.....................................................................................................................31
7.2 Gasket..............................................................................................................................32
7.3 Door .................................................................................................................................32
8. Exploded Diagram and Parts List for the Blue Ridge 300 P (ESW0007) ............................ 35
9. Exploded Diagram and Parts List for the Blue Ridge 300 L (ESW0008) ............................ 38
ENGLANDER LIMITED LIFETIME WARRANTY ......................................................................... 40

Page 4 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
1. CERTIFICATION PLATE

Page 5
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH

Page 6 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model Blue Ridge 300 P & L (ESW0007 and ESW0008)
Type of combustion Non catalytic
Fuel Type Dry Cordwood
Recommended heating area (sq. ft..)1 500 to 2,100 ft2(47 to 195 m2)
Overall firebox volume22.4 ft3(0.068 m3)
EPA Loading volume 1.95 ft3(0.055 m3)
Maximum burn time18 hours
Maximum heat output (dry cordwood)3 75,000 BTU/h (22 kW)
Overall heat output rate (min. to max.)2 4 14,200 BTU/h to 44,500 BTU/h
(4.16 kW to 13.04 kW)
Average overall efficiency3
(Dry cordwood) 72 % (HHV)577 % (LHV)6
Optimum efficiency7 79 %
Optimum overall efficiency8 76 %
Average particulate emissions rate9 2.3 g/h (EPA / CSA B415.1)10
Average CO11 69 g/h
1Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is dened by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2The overall rebox calculation is an approximation and is not intended to be used for loading. This volume includes a buffer zone to allow an easier
fuel insertion, prevent ash spillage and allow the air wash to work properly.
3The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft3and 20 lb/ft3. Other performances are based on
a fuel load prescribed by the standard. The specied loading density varies between 7 lb/ft³ and 12 lb/ft3. The moisture content is between 19%
and 25%.
4As measured per CSA B415.1 stack loss method.
5Higher Heating Value of the fuel.
6Lower Heating Value of the fuel.
7Optimum overall efciency at a specic burn rate (LHV).
8The optimum heat transfer efciency is for the low burn rate and represents the appliance's ability to convert the energy contained in the wood logs
into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
9This appliance is ofcially tested and certied by an independent agency.
10 Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053. Based on ALT-125 sent by EPA on
February 28th, 2018.
11 Carbon monoxide.

Page 7
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.2 Specifications
Recommended log length 16 in (406 mm) east-west
Maximum log length1 20 in (508 mm) east-west
Flue outlet diameter 6 in (150 mm)
Recommended connector pipe diameter 6 in (150 mm)
Type of chimney ULC S629, UL 103 HT (2100 °F)
Minimum chimney height 12 feet
Baffle material Vermiculite
Approved for alcove installation Yes
Approved for mobile home installation2 Yes
Type of door Simple, glass with cast iron frame
Type of glass Ceramic glass
Particulate emission standard3 EPA / CSA B415.1
USA standard (Safety) UL 1482, UL 737
Canada standard (Safety) ULC-S627
1North-south: ends of the logs visible, East-west: sides of the logs visible.
2 Mobile homes (Canada) or manufactured homes (USA): The US Department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as follows; buildings built on xed wheels and those transported on temporary wheels/axles and set on a permanent
foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or substantially
completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the CAN/CSA-
Z240 MH standard.
3Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053. Based on ALT-125 sent by EPA on
February 28th, 2018.

Page 8 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.3 Dimensions
2.3.1 Blue Ridge 300 P Dimensions (with pedestal)
O6"
153mm
22"
559mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300P (ESW0007)
OPTION
25 1/2"
648mm
12 3/4"
324mm
12"
304mm
6 1/2"
165mm
14 7/8"
378mm
9 1/4"
235mm
OPTION
33 1/4"
844mm
30 3/4"
783mm
Figure 1: Top View
O6"
153mm
22"
559mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300P (ESW0007)
OPTION
25 1/2"
648mm
12 3/4"
324mm
12"
304mm
6 1/2"
165mm
14 7/8"
378mm
9 1/4"
235mm
OPTION
33 1/4"
844mm
30 3/4"
783mm
O6"
153mm
22"
559mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300P (ESW0007)
OPTION
25 1/2"
648mm
12 3/4"
324mm
12"
304mm
6 1/2"
165mm
14 7/8"
378mm
9 1/4"
235mm
OPTION
33 1/4"
844mm
30 3/4"
783mm
Figure 2: Front View Figure 3: Side View

Page 9
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.3.2 Blue Ridge 300 L Dimensions (with legs)
O
6"
153mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300L (ESW0008)
OPTION
12 3/4"
324mm
6 1/2"
165mm
12"
304mm
25 1/2"
648mm
9 1/4"
235mm
14 7/8"
378mm
OPTION
24 3/8"
620mm
30 5/8"
778mm
28 1/4"
717mm
Figure 4: Top View
O6"
153mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300L (ESW0008)
OPTION
12 3/4"
324mm
6 1/2"
165mm
12"
304mm
25 1/2"
648mm
9 1/4"
235mm
14 7/8"
378mm
OPTION
24 3/8"
620mm
30 5/8"
778mm
28 1/4"
717mm
O6"
153mm
21 3/8"
543mm
28"
711mm
32 3/8"
824mm
BLUE RIDGE 300L (ESW0008)
OPTION
12 3/4"
324mm
6 1/2"
165mm
12"
304mm
25 1/2"
648mm
9 1/4"
235mm
14 7/8"
378mm
OPTION
24 3/8"
620mm
30 5/8"
778mm
28 1/4"
717mm
Figure 5: Front View Figure 6: Side View

Page 10 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.3.3 Blue Ridge 300 P Combustion Chamber Dimensions (with pedestal)
21"
533mm
9"
228mm
17 1/2"
444mm
BLUE RIDGE 300P (ESW0007)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
16 1/2"
419mm
12"
303mm
5/16"
8mm
3/16"
5mm
Figure 7: Door Opening
21"
533mm
9"
228mm
17 1/2"
444mm
BLUE RIDGE 300P (ESW0007)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
16 1/2"
419mm
12"
303mm
5/16"
8mm
3/16"
5mm
21"
533mm
9"
228mm
17 1/2"
444mm
BLUE RIDGE 300P (ESW0007)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
16 1/2"
419mm
12"
303mm
5/16"
8mm
3/16"
5mm
Figure 8: Front View - Combustion Chamber Figure 9: Side View - Combustion Chamber

Page 11
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.3.4 Blue Ridge 300 L Combustion Chamber Dimensions (with legs)
BLUE RIDGE 300L (ESW0008)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
17 3/8"
440mm
9"
228mm
21"
533mm 16 1/2"
419mm
5/16"
8mm
3/16"
5mm
12"
303mm
Figure 10: Door Opening
BLUE RIDGE 300L (ESW0008)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
17 3/8"
440mm
9"
228mm
21"
533mm
16 1/2"
419mm
5/16"
8mm
3/16"
5mm
12"
303mm
BLUE RIDGE 300L (ESW0008)
©2022, FABRICANT DE POÊLE INTERNATIONAL INC. TOUS DROITS RÉSERVÉS / ALL RIGHTS RESERVED
17 3/8"
440mm
9"
228mm
21"
533mm
16 1/2"
419mm
5/16"
8mm
3/16"
5mm
12"
303mm
Figure 11: Front View - Combustion Chamber Figure 12: Side View - Combustion Chamber

Page 12 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
2.4 EPA Loading
The loading methods shown below are those that were used during emissions certification.
2.4.1 Air control
The air control is located underneath the ash shelf.
To open the air control, push the air control handle
completely to the left (High). This will increase the
burn rate. To close the air control, push the air
control handle completely to the right (Low). This will
decrease the burn rate.
2.4.2 High burn rate (primary air control open)
Open the air control completely. Place height small
pieces (2" x 2") of wood in the firebox crossing them
at the greatest possible angle. Criss cross 10 to 16
kindling wood pieces on the small pieces of wood in
three layers at the greatest possible angle. Tie knot
with five sheets of paper and place them on top of the kindling wood. Light up the paper and let
the door ajar at 90° until all the kindling wood is on fire and the first row of small pieces of wood
is on fire too. Close the door. When there is no more fire in the front of the firebox and there are
only faint flames on the wood in the back of the firebox, break ashes, level the coal bed and put
five logs in the firebox. Put 3 pieces on the coal bed, without air space between them. Leave one
inch of air space between the rear firebrick and the first piece. The two other pieces should be
added on top of the first 3, in an East-West configuration. Let the door ajar to leave a space of
one inch on the door handle’s side for 1 minute maximum and then close the door.
2.4.3 Medium and low burn rate
On a two inches thick coal bed that is still red, place three logs in an East-West orientation.
There should be air space between each log and between the logs and the bricks. The two other
pieces should be added on top of the first three, slightly angled of 20°. Let the door ajar at 90°
for approximately 5 min. Then, close the door with the primary air control open. Leave to burn
with the primary air control open for approximately 10 more minutes and then close the primary
air control completely for the low burn rate and halfway for the medium burn rate. For better
results, close the air control gradually from the closing of the door to the complete closing of
the air control.

Page 13
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3. Clearances to Combustible Material
The clearances shown in this section have been determined by tests according to procedures
set out in safety standards ULC S627 (Canada), UL 1482 (U.S.A.) and UL 737 (U.S.A.). When
the stove is installed so that its surfaces are at or beyond the minimum clearances specified,
combustible surfaces will not overheat under normal and even abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the minimum clearance
figures given.
Clearances may only be reduced by means approved by the regulatory authority.
The clearances to combustible walls may be slightly different in Canada and the U.S.A. and may
also differ depending on whether single or double wall flue pipe is used. Make sure to choose
the correct clearance for the stove location and type of flue pipe.
The clearances of the appliance and the flue pipes must be met individually, meaning the appliance
cannot be installed closer to the combustible materials than the single or double wall pipe allows.
For a safe way to reduce clearances refer to section"5. Reducing Wall and Ceiling Clearances Safely"
of this manual.
3.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA Canada USA
A14 ½" (368 mm) 11" (279 mm) A6" (152 mm) 6" (152 mm)
B22" (559 mm) 22" (559 mm) B22" (559 mm) 22" (559 mm)
C12" (305 mm) 12" (305 mm) C12" (305 mm) 12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES1FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTORE
Canada USA Canada USA
D18" (457 mm) 14 ½" (368 mm) D9 ¼" (235 mm) 9 ¼" (235 mm)
E31 ½" (800 mm 31 ½" (800 mm) E31 ¼" (794 mm) 31 ¼" (794 mm)
F21 ¾" (552 mm) 21 ¾" (552 mm) F21 ½" (546 mm) 21 ½" (546 mm)
1The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.

Page 14 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
A
B
E
D
CAN
48"
122 cm
US
36"
92 cm
48"
Flush
F
FC
Figure 13: Clearances - Top Figure 14: Clearances - Corner
84"
213 cm
Ve
Ho
N
Figure 15: Clearances - Side

Page 15
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3.1.1 With Heat Shield AC027621
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat
shield certified with the single wall pipe connector to be used as close as 6" from combustible
materials must be used. Only in this case, the same clearances as a certified double wall pipe
connector can be used. Refer to the booklet in the screen options to obtain the dimensions to
be respected.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES2FROM DOUBLE WALL
PIPE CONNECTOR
Canada USA Canada USA
A3" (76 mm) 3" (76 mm) D6 ¼" (159 mm) 6 ¼" (159 mm)
B4" (102 mm) 4" (102 mm) E13 ¼" (337 mm) 13 ¼" (337 mm)
C3" (76 mm) 3" (76 mm) F12 ½" (318 mm) 12 ½" (318 mm)
A
B
E
D
CAN
48"
122 cm
US
36"
92 cm
48"
Flush
F
FC
If the clearance reduction is on the same side as the door handle, position the stove at
a minimum of 6 inches from the side wall (clearance B), otherwise it may be located at
the clearance shown in the table above.
1 Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certied with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certied double wall
pipe connector can be used.
2The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.

Page 16 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada USA
A14 ½" (368 mm) 11" (279 mm)
B23" (584 mm) 23" (584 mm)
C12" (305 mm) 12" (305 mm)
L77" (196 mm) 77" (196 mm)
Ve
Ho
L
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA
A9" (229 mm) 9" (229 mm)
B23" (584 mm) 23" (584 mm)
C12" (305 mm) 12" (305 mm)
L77" (196 mm) 77" (196 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES1FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D18" (457 mm) 14 ½" (368 mm) D12 ¼" (311 mm) 12 ¼" (311 mm)
E32 ½" (825 mm) 32 ½" (825 mm) E32 ¼" (819 mm) 32 ¼" (819 mm)
F21 ¾" (552 mm) 21 ¾" (552 mm) F21 ½" (549 mm) 21 ½" (549 mm)
1The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.

Page 17
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3.1.3 With Heat Shield AC02762 and Lowered Ceiling
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat
shield certified with the single wall pipe connector to be used as close as 6" from combustible
materials must be used. Only in this case, the same clearances as a certified double wall pipe
connector can be used. Refer to the booklet in the screen options to obtain the dimensions to
be respected.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA
A5" (127 mm) 5" (127 mm)
B6" (152 mm) 6" (152 mm)
C5" (127 mm) 5" (127 mm)
L80" (203 mm) 80" (203 mm)
Ve
Ho
L
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA
D8 ¼" (210 mm) 8 ¼" (210 mm)
E15 ¼" (387 mm) 15 ¼" (387 mm)
F14 ½" (368 mm) 14 ½" (368 mm)
A
B
E
D
CAN
48"
122 cm
US
36"
92 cm
48"
Flush
F
FC
If the clearance reduction is on the same side as the door handle, position the stove at
a minimum of 6 inches from the side wall (clearance B), otherwise it may be located at
the clearance shown in the table above.
1The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.

Page 18 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3.1.4 Inside a Combustible Alcove
See section 3.1 for the single wall pipe installation.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA
A9" (229 mm) 9" (229 mm)
B23" (584 mm) 23" (584 mm)
K48" (1219 mm) 36" (914 mm)
L77" (196 cm) 77" (196 cm)
Ve
Ho
L
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA
D12 ¼" (311 mm) 12 ¼" (311 mm)
E32 ¼" (819 mm) 32 ¼" (819 mm)
A
B
E
D
K
E
B
3.1.5 Mobile Home
It is strictly forbidden to install a unit with a single wall pipe in a mobile home.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A11" (279 mm) 11" (279 mm) D14 ¼" (362 mm) 14 ¼" (362 mm)
B24" (610 mm) 24" (610 mm) E33 ¼" (845 mm) 33 ¼" (845 mm)
C13" (330 mm) 13" (330 mm) F22 ½" (572 mm) 22 ½" (572 mm)
1The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.

Page 19
Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
3.1.6 Mobile Home With Heat Shield AC02762
It is strictly forbidden to install a unit with a single wall pipe in a mobile home.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES1FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A3" (76 mm) 3" (76 mm) D6 ¼" (159 mm) 6 ¼" (159 mm)
B6" (152 mm) 6" (152 mm) E15 ¼" (387 mm) 15 ¼" (387 mm)
C3" (76 mm) 3" (76 mm) F12 ½" (318 mm) 12 ½" (318 mm)
A
B
E
D
CAN
48"
122 cm
US
36"
92 cm
48"
Flush
1Les distances de tuyau listées dans ce tableau se réfèrent aux distances obtenues lorsque le poêle est installé en accord avec les dégagements
de l’appareil mentionnés ci-dessus.

Page 20 Installation and Operation Requirements - Blue Ridge 300 P & L
ENGLISH
4. Floor Protection
This stove is designed to prevent the floor from overheating. However, it must be placed on a
non-flammable surface to protect the floor from hot embers that may fall during loading.
The floor protection must be a continuous, non combustible material, such as steel with a minimum
thickness of 0.015" (0.38 mm) or ceramic tiles sealed together with grout. Cement board, brick, or
any other approved or listed material suited for floor protection. No R factor required.
Any type of tile will require a continuous non combustible sheet beneath to prevent the possibility
of embers falling through to the combustible floor if cracks or separation should occur in the
finished surface. Check local codes for approved alternatives.
No protection is required if the unit is installed on a non-combustible floor (ex: concrete).
FLOOR PROTECTION
Canada1USA
G28" (203 mm) N/A
H8" (203 mm) N/A
I18" (457 mm) From
door opening
16" (406 mm) From
door opening
JN/A 8" (203 mm)
K41 ½" (1054 mm) 31" (787 mm)
N3N/A See note 3
S47 ⅜" (1203 mm) 37 ⅜" (949 mm)
T33 ½" (851 mm) 26 ½" (673 mm)
U41 ½" (1054 mm) 31" (787 mm)
V68 ⅛" (1730 mm) 52 7/8" (1343 mm)
H
I
G
J
K
S
Figure 16: Floor Protection
U
T
V
84"
213 cm
Ve
Ho
N
1In Canada, to comply with CSA B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment, any combustible covering beneath the
appliance and/or within the area extending horizontally at least 450 mm (18 in) beyond the appliance on any side equipped with a door, and at least
200 mm (8 in) beyond the appliance on other sides, shall be protected by a continuous, durable, non-combustible pad that will ember protection. The
450 mm (18 in) ember protection required on any side with a door shall extend for the full width of the appliance plus the 200 mm (8 in) required
on each side of the appliance without a door. Where the appliance is installed less than 200 mm (8 in) from a wall, the ember pad need only extend
to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is structurally supported to prevent displacement and
distortion.
2The oor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm).
3Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm).
This manual suits for next models
3
Table of contents
Other Englander Wood Stove manuals
Popular Wood Stove manuals by other brands

Nibe
Nibe Contura 620G manual

Eureka
Eureka Nugget Mk2 Freestanding Operation & installation instructions

Napoleon
Napoleon Knightsbridge VF Series Installation and operation manual

Dovre
Dovre 2576CBSC Installation instructions and operating manual

Vermont Castings
Vermont Castings The Aspen 1920 Homeowner's installation and operating manual

Vermont Castings
Vermont Castings The Intrepid II 1990CE Homeowner's installation and operating manual