Step 4: Beverage Lines
4 a) Identify the Beverage A line from Keg A to the tap/faucet. Cut the line at a point that will t the Nitro Infuser mounting location.
4 b) Connect the Beverage A tap line from the faucet to the Nitro Infuser line labeled “Output A”. Secure with hose clamp.
4 c) Connect the Beverage A keg out line to the Nitro Infuser line labeled “Beverage A”. Secure with hose clamp.
4 d) Repeat steps 4 a) - 4 c) to connect Beverage B line to the Nitro Infuser.
Step 5: Mount Nitro Infuser to Keg System
5 a) Once all connections are complete, double-check connections to assure hose clamps have been tightened.
5 b) Attach Nitro Infuser to kegerator in desired location from Step 2.
Step 6: Pressurizing System
6 a) Keep tap faucet in the closed position.
6 b) Turn the nitrogen gas cylinder to a full open position.
6 c) Adjust gas regulator to 28 psi - please note that if the regulator is set to higher than 28 psi you will need to release pressure
from coee keg once regulator is adjusted to 28 psi.
6 d) You will hear nitrogen gas pressurizing the keg for a short time. Check every connection for any gas or leaks. It is important to
Step 7: Adjusting Your Nitro Infuser
7 a) Start with the Nitrogen Control System (NCS) valve all the way closed and pour a drink.
7 b) Open NCS valve one full turn. Pour and analyze infusion level. Adjust accordingly open or closed one quarter turn at a time.
7 c) Once the desired infusion level is found, lock in the NCS by tightening the hex nut against the NCS.
Step 3: Nitrogen Gas Lines
*It is important to make sure your gas system is turned o until the install is complete*
3 a) Using one of the provided T ttings, connect one side to the rst gas line coming from your dual regulator. Secure with hose
clamp.
3 b) Connect another side of the T to one of the provided hoses. Secure with hose clamp. Connect the other end of the hose to
the “gas in” connection on your keg. Secure with hose clamp.
3 c) Connect the last side of the T to the second provided hose. Secure with hose clamp. Connect the other end of the hose to
the Nitro Infuser, on one of the barbs labeled “Gas”. Secure with hose clamp.
3 d) Repeat steps 3 a) - c) with the second T tting, connecting the second gas line from the dual regulator to the second keg
and the Nitro Infuser.
© Enhanced Beverage Solutions | August 2019 | Revision 2.003 | Patent Pending
www.enhancedbeveragesolutions.com | @enhancedbeveragesolutions | #TapCulture
CLEANING
Cleaning your tap lines will clean the infusion system. It is recommended that you clean your tap lines every 1-2 weeks.
It is recommended to remove your stout nozzle and rinse daily.