manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. enviroswim
  6. •
  7. Lighting Equipment
  8. •
  9. enviroswim ES-3 User manual

enviroswim ES-3 User manual

Enviroswim ES-3 Installation Guide
©Enviroswim 2021 ©Enviroswim 2021 V3.0AU
These instructions are repeated in the User Manual and should be repeated if the pool is refilled.
Adjust water balance
Parameter
Minimum
Ideal Range
Maximum
Adjust by
pH
6.8
7.1 - 7.4
7.6
Use Hydrochloric Acid or Sodium Bisulphate to
reduce. Sodium Bicarbonate to increase
Calcium
Hardness
160
170 - 250ppm
400
Use Calcium Chloride to increase
Alkalinity
50
60 -150ppm
200
Use Sodium Bicarbonate to increase
TDS
1000
1000-1500ppm
1500
Use Pool Salt to increase –Dilute to decrease
Do not use Cyanuric Acid (Stabliser) as this will interfere with the oxidising capability of the Enviroswim
system
Complete your warranty from at https://www.enviroswim.com/warranty-registration/
1. Balance the water as per above. Ensure all Enviroswim switches are set to OFF and variable controls (Ioniser
and ORP) at minimum (fully counter clockwise).
2. Turn on the pool pump so that water is flowing through the filtration
system, including the Enviroswim ionization/oxidation wet cell
housing and ultrasonic emitter pipe. Make sure that the
ionization/oxidation wet cell housing is filled with water. Set the left-
hand switch on the Enviroswim unit to MANUAL.
3. Turn on the right hand ON/OFF switch on the control box.
4. Turn the knob on the control box under the ORP meter slowly
clockwise until the ORP meter reads between 13 - 15 Amps.
5. Turn the ioniser switch to maximum. Run the unit for approximately
1 hour per 1,000 litres of water and test copper level.
6. Perform chemical tests to determine readings for pH, ORP,
alkalinity, copper, and calcium hardness then adjust accordingly.
Refer to User Manual for appropriate treatments.
7. Test the copper level - copper level can only be checked when pH is in the correct range. When the copper
levels are within the range of 0.2-0.4 ppm, set the timeclock for the appropriate run time (1 hour per 10,000
litres) and adjust the Ioniser output to around 40%.
8. Start-up is now complete. Refer to the User Manual for a guide on run times. Remember every pool is different.
Factors that will impact runtime are location, bather load, season, type of cover and water temperature.
When can I use the pool?
When all the water levels are balanced correctly, as per the above table.
1. Plan layout of components
a. Check component dimensions.
b. Confirm sequence of components in water flow.
c. Check cable lengths for control box location.
d. Power Supply
2. Confirm additional materials required
a. Pipe fittings and Pipe adhesive
b. Cable ties
c. Mounting Screws
3. Tools
a. Pipe Saw
b. Drill and Bits
c. Screwdriver
Balance Water
3. Commission
Balance Water
1. Plan
2. Install
3. Commission
1. Plan
What’s in the Box?
1 x Enviroswim Control Unit
1 x Complete Wet cell housing
➢1 x Oxidiser Plate
➢1 x Copper/silver Electrodes
1 x Ultrasonic Chamber
1 x Power Cable
4 x 40/50mm reducing bushes
1 x Installation Guide
1 x User Manual
1 x Copper test kit
Review
instructions next
page
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION INSTALLER
This installation guide contains important information about the installation of this product. For complete instructions
on operation and safe use of this product refer to Enviroswim ES-3 User Manual.
WARNING - READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING –To reduce the risk of injury, do not permit children to use this product.
WARNING –When mixing acid with water, ALWAYS ADD ACID TO WATER, NEVER ADD WATER TO ACID.
WARNING –There are no serviceable parts in the control box. Return to Enviroswim for service.
WARNING –Do not operate electrolytic cell without proper flow or water circulation. A build-up of gases can
occur and cause hazardous conditions.
CAUTION –Use of chemicals other than those recommended may be hazardous. Follow the Chemical
Manufacturer’s Instructions.
CAUTION –This unit is for use with permanently installed pools. Do not use with storable pools. A permanently
installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for
storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and
reassembled to its original integrity.
CAUTION –Some modern variable speed pumps have settings that produce inadequate water flow to either fill
the ES-3 wet cell or create sufficient flow to affect the ES-3 processes. Ensure the wet cell housing has adequate
flow of water and is full of water while the Enviroswim is operating.
READ ALL THESE INSTRUCTIONS
For advice phone 07 5655 6150 or email : info@enviroswim.com
©Enviroswim 2021
2. Install
290mm
Recommended
Maintenance Access
Recommended
Maintenance Access
135mm
Actual Size Drilling Template
Ultrasonic Chamber
1.8 Metre Lead
1.8
Metres
WARNING :
Ensure cell is mounted
oriented as shown.
Horizontal with water
flow from underneath.
Other orientations may
disable water level
sensor. Water Inflow
should always be at
oxidiser end.
For 50mm pool pipe, reducers for 40 mm included.
WARNING : Do not use
primer on acrylic cell.
Oxidiser Plates
1.8 Metre Lead
Copper/silver Electrodes
1.8 Metre Lead
(170mm deep)
360mm
mm
250mm
150mm
140mm
Ultrasonic Chamber
may be installed
anywhere within the
filtration pipework,
with any orientation.
380mm
45 mm
45 mm
Recommended sequence guide
Acid Doser (optional)
Mains Power Supply:
240V/50Hz 10Amp
earthed power supply

Other manuals for ES-3

4

Popular Lighting Equipment manuals by other brands

Titanium TT-08-3000-O quick start guide

Titanium

Titanium TT-08-3000-O quick start guide

GVM RGB-T20R manual

GVM

GVM RGB-T20R manual

Lucci Fresco SENTINEL ADJUSTABLE WALL SPOT installation instructions

Lucci Fresco

Lucci Fresco SENTINEL ADJUSTABLE WALL SPOT installation instructions

iGuzzini MAXIWOODY manual

iGuzzini

iGuzzini MAXIWOODY manual

LED World FB60M50-M-24V-RGB Series Important instructions

LED World

LED World FB60M50-M-24V-RGB Series Important instructions

Cameo SNAPBAG CLZW600SSBS installation instructions

Cameo

Cameo SNAPBAG CLZW600SSBS installation instructions

Beamever LINIO NEON 0408 SV Using instruction

Beamever

Beamever LINIO NEON 0408 SV Using instruction

Martin MAC 101 Series Brochure & specs

Martin

Martin MAC 101 Series Brochure & specs

NANLUX Evoke 1200B instruction manual

NANLUX

NANLUX Evoke 1200B instruction manual

thomann ignition Wotan 300 user manual

thomann

thomann ignition Wotan 300 user manual

U.S. Sunlight Radiant Skylight Tube Installation and mounting guide

U.S. Sunlight

U.S. Sunlight Radiant Skylight Tube Installation and mounting guide

Synexis SPHERE owner's manual

Synexis

Synexis SPHERE owner's manual

Robe DigitalSpot 7000 DT installation instructions

Robe

Robe DigitalSpot 7000 DT installation instructions

Robus R282DEPK-CU instruction manual

Robus

Robus R282DEPK-CU instruction manual

Interline 57600001 installation manual

Interline

Interline 57600001 installation manual

Sunny CU Series user manual

Sunny

Sunny CU Series user manual

NANGUANG NANLITE MaxPad II 11C user manual

NANGUANG

NANGUANG NANLITE MaxPad II 11C user manual

Chauvet Colorado 1 Tri IP user manual

Chauvet

Chauvet Colorado 1 Tri IP user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.