Enviroswim ES-3 Installation Guide
©Enviroswim 2021 ©Enviroswim 2021 V3.0AU
These instructions are repeated in the User Manual and should be repeated if the pool is refilled.
Adjust water balance
Use Hydrochloric Acid or Sodium Bisulphate to
reduce. Sodium Bicarbonate to increase
Use Calcium Chloride to increase
Use Sodium Bicarbonate to increase
Use Pool Salt to increase –Dilute to decrease
Do not use Cyanuric Acid (Stabliser) as this will interfere with the oxidising capability of the Enviroswim
system
Complete your warranty from at https://www.enviroswim.com/warranty-registration/
1. Balance the water as per above. Ensure all Enviroswim switches are set to OFF and variable controls (Ioniser
and ORP) at minimum (fully counter clockwise).
2. Turn on the pool pump so that water is flowing through the filtration
system, including the Enviroswim ionization/oxidation wet cell
housing and ultrasonic emitter pipe. Make sure that the
ionization/oxidation wet cell housing is filled with water. Set the left-
hand switch on the Enviroswim unit to MANUAL.
3. Turn on the right hand ON/OFF switch on the control box.
4. Turn the knob on the control box under the ORP meter slowly
clockwise until the ORP meter reads between 13 - 15 Amps.
5. Turn the ioniser switch to maximum. Run the unit for approximately
1 hour per 1,000 litres of water and test copper level.
6. Perform chemical tests to determine readings for pH, ORP,
alkalinity, copper, and calcium hardness then adjust accordingly.
Refer to User Manual for appropriate treatments.
7. Test the copper level - copper level can only be checked when pH is in the correct range. When the copper
levels are within the range of 0.2-0.4 ppm, set the timeclock for the appropriate run time (1 hour per 10,000
litres) and adjust the Ioniser output to around 40%.
8. Start-up is now complete. Refer to the User Manual for a guide on run times. Remember every pool is different.
Factors that will impact runtime are location, bather load, season, type of cover and water temperature.
When can I use the pool?
When all the water levels are balanced correctly, as per the above table.
1. Plan layout of components
a. Check component dimensions.
b. Confirm sequence of components in water flow.
c. Check cable lengths for control box location.
d. Power Supply
2. Confirm additional materials required
a. Pipe fittings and Pipe adhesive
b. Cable ties
c. Mounting Screws
3. Tools
a. Pipe Saw
b. Drill and Bits
c. Screwdriver
What’s in the Box?
1 x Enviroswim Control Unit
1 x Complete Wet cell housing
➢1 x Oxidiser Plate
➢1 x Copper/silver Electrodes
1 x Ultrasonic Chamber
1 x Power Cable
4 x 40/50mm reducing bushes
1 x Installation Guide
1 x User Manual
1 x Copper test kit
Review
instructions next
page
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION INSTALLER
This installation guide contains important information about the installation of this product. For complete instructions
on operation and safe use of this product refer to Enviroswim ES-3 User Manual.
WARNING - READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING –To reduce the risk of injury, do not permit children to use this product.
WARNING –When mixing acid with water, ALWAYS ADD ACID TO WATER, NEVER ADD WATER TO ACID.
WARNING –There are no serviceable parts in the control box. Return to Enviroswim for service.
WARNING –Do not operate electrolytic cell without proper flow or water circulation. A build-up of gases can
occur and cause hazardous conditions.
CAUTION –Use of chemicals other than those recommended may be hazardous. Follow the Chemical
Manufacturer’s Instructions.
CAUTION –This unit is for use with permanently installed pools. Do not use with storable pools. A permanently
installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for
storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and
reassembled to its original integrity.
CAUTION –Some modern variable speed pumps have settings that produce inadequate water flow to either fill
the ES-3 wet cell or create sufficient flow to affect the ES-3 processes. Ensure the wet cell housing has adequate
flow of water and is full of water while the Enviroswim is operating.
READ ALL THESE INSTRUCTIONS
For advice phone 07 5655 6150 or email : info@enviroswim.com