BEFORE PROCEEDING WITH INSTALLATION
Ensure all supply lines are ushed thoroughly to remove
debris prior to the installaon of this product as per
AS/NZS 3500.1. Strainers (40 mesh) are recommended if
debris is an ongoing problem.
1. Ensure water lines have been thoroughly ushed and
are free of debris.
2. Fit the dress ring to the bubbler and engage the
an-rotaon pins in the pin-holes.
3. Screw the bubbler to the desired posion on the ½”
MI thread without sealant or thread tape and mark the
countersunk holes.
4. Remove the bubbler and drill holes to accept a suitable
countersunk screw or xing.
Note: the holes are oset to allow easy access of a
screwdriver
5. Seal thread using thread tape (or other approved
means) and screw the bubbler into posion with the
dress ring ed and an-rotaon pins engaged.
6. Turn water on and acvate the bubbler and bole ller
to bleed any air that may be trapped in the bubbler.
Check the connecon point for leaks. Fit screws to
secure the bubbler in place.
7. Acvate the bubbler and bole ller a number of
mes, the bubbler ow stream will sele to a height
50-100mm above the mouthguard and is now ready to
use.
57.5
10
100
26
130
200
180
110
85
22
33
16 55
10
5TYP
DEPTH)
SPACE FOR
CIRCUIT BOARD
(REQUIRES 30mm
COVER PLATE
OUTLINE
IMAGE 2
Bubbler Inlet Connecon 15mm (1/2" BSP)
Spring Loaded SBA (Spindle) 5/8” BSP
Recommended Working Pressure
Range
100 – 500 kPa
(Max. 500 kPa – AS3500)
Flow Rate (Drinking Fountain)
2 – 2.5 L/min approx.
with ow stream set
50mm above guard top
Recommended Operang
Temperature Range for Drinking
Fountains
5 – 30 °C
COMPLIANCE
Enware products must be installed in
accordance with the Plumbing Code of
Australia (PCA), AS/NZS3500 and the
manufacturer’s instrucons. Installaons
not complying with PCA, AS/NZS 3500 and
the manufacturer’s instrucons may void
the product and performance warranty
provisions.
This product must be installed and
commissioned by a qualied plumber.
57.5
10
100
26
130
200
180
110
85
22
33
16 55
10
5TYP
DEPTH)
SPACE FOR
CIRCUIT BOARD
(REQUIRES 30mm
COVER PLATE
OUTLINE
IMAGE 1

3 Call 1300 369 273 www.enware.com.au
components
spare parts
Handle Cap and Screw - Bubbler BUB378NC
Handle Cap and Screw - Bubbler and Bole Filler BUB378NCBF
Cartridge - Bubbler BUB260NC
Cartridge - Bubbler and Bole Filler BUB260NCBF
Mouth Guard BUB734NC
Spout Insert BUB258
Cap and Screw BUB400
22
Hob/Wall Penetration

4 Call 1300 369 273 www.enware.com.au
trouble shooting
PROBLEM CAUSE RECTIFICATION
Flow stream is unsteady or
too low
Water supply condions have
changed or are uctuang
Incorrect ow adjustment
Check that water pressure is between
100kPa and 500kPa.
Remove the bubbler outlet and/or bole
ller by removing the securing grubscrew
and pulling free.
Flush the bubbler thoroughly.
Disassemble the bubbler outlet and clean
any debris from the ow control, check
valve or gauze. Any damaged parts should
be replaced. Reassemble and test.
cleaning
Enware product should be cleaned with a so damp cloth using only mild liquid detergent or soap and water.
Do not use cleaning agents containing a corrosive acid, sourcing agent or solvent chemicals. Do not use cream
cleaners, as they are abrasive. Damage caused this way will not be covered by warranty.

product warranty for Australia Eecve 1 September 2014
Enware Australia Pty Limited (ACN 003 988 314)
(“we” or “us”) warrants that this product (also referred
to as “our goods”) will be free from all defects in
materials and workmanship for 24 months* from the
date of purchase. Our liability under this warranty is
limited at our opon to the repair or replacement of
the defecve product or part, the cost of repair of the
defecve product or part or the supply of an equivalent
product or part, in each case if we are sased the
loss or damage was due to a defect in the materials or
workmanship of the product or part. All products must
be installed in accordance with the manufacturer’s
instrucons, the PCA, and AS/NZS3500 including any
other applicable regulatory requirements.
exceptions
This warranty does not apply in respect of any damage
or loss due to or arising from:
a) Failure by you or any other person to follow any
instrucons for use (including instrucons and direcons
relang to the handling, storage, installaon, ng,
connecon, adjustment or repair of the product)
published or provided by us;
b) Failure by you or any other person responsible for the
ng, installaon or other work on the product to follow
or conform to applicable laws, standards and codes
(including the AS/NZ 3500 set of Standards, all applicable
State and Territory Plumbing Codes, the Plumbing Code
of Australia and direcons and requirements of local and
other statutory authories); or
c) Any act or circumstance beyond our control including
faulty installaon or connecon, accident, abnormal use,
acts of God, damage to buildings, other structures or
infrastructure and loss or damage during product transit
or transportaon.
making a claim
To make a claim under this warranty you must
nofy us in wring within 7 days of any alleged defect
in the product coming to your aenon and provide
us with proof of your purchase of the product and
completed the Online Product Service and Warranty
form at www.enware.com.au/product-service-enquiry
All nocaons and accompanying forms must be
sent to Enware Australia Pty Limited, 9 Endeavour Rd,
Caringbah NSW 2229. Contact can also be made by
calling 1300 369 273 or email (info@enware.com.au).
Your costs in making a claim under this warranty,
including all freight, collecon and delivery costs, are
to be borne and paid by you. We also reserve the right
at our cost to inspect any alleged defect in the product
wherever it is located or installed or on our premises.
*Condional warranty: Jumper Valve Tapware - 2 Years:
1 year parts and labour on the complete assembly then
a further 1 year parts only warranty is applicable
Ceramic Disc Cartridge Tapware - 10 Years: 10 Year
ceramic disc cartridges – parts only; 1 Year parts and
labour on complete assembly
Outlets - 1 Year parts & labour on complete assembly
other conditions
Except as provided or referred to in this document, we
accept no other or further liability for any damages
or loss (including indirect, consequenal or economic
loss) and whether arising in contract, tort or otherwise.
Any benets available to you under this warranty are in
addion to any non-excludable rights or remedies you
may have under applicable legislaon, including as a
“consumer” under the Australian Consumer Law. To that
extent you need to be aware that: Our goods come with
guarantees that cannot be excluded under the Australian
Consumer Law. You are entled to a replacement or
refund for a major failure and for compensaon for any
other reasonably foreseeable loss or damage. You are
also entled to have the goods repaired or replaced if
the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
This manual suits for next models
5
Table of contents
Other enware Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Urban
Urban A300 Installation, operation and maintenance instructions

SunSun
SunSun COP-10000 instruction manual

PEAKTOP
PEAKTOP FB0016BA instructions

Angelo Decor
Angelo Decor Avante AD95161 quick start guide

Massarelli's
Massarelli's Tranquillity 3684 Setup instructions

CLIMAQUA
CLIMAQUA HELIOS L instructions

Elkay
Elkay Swirlflo Freeze Resistant Fountain... Installation & use manual

Angelo Decor
Angelo Decor AD93343 Assembly instructions

Halsey Taylor
Halsey Taylor HRFG-ER owner's manual

Bernini
Bernini Sorrento Fountain owner's manual

BENITO
BENITO Urban FONTI UM509 Assembly instructions

Profi-pumpe
Profi-pumpe TERRA-2 operating instructions