CAUTION!
Before commencing any work on the electrical
connections, you must rst disconnect the thermostat
from the mains. None of the 230V connections must be
live until the installation has been completed and the
housing is closed. Only qualied electricians or authorised
service sta are permitted to open the thermostat.
There are parts that may carry mains voltage behind the
cover. The thermostat must not be left unsupervised
when open. (Prevent non specialists and especially
children from gaining access to it.)
Operating Instructions
Page 1 of 2
CDTP2 Room Thermostat Hardwired
4. Installation
1. Factory default settings
8. Resetting the thermostat
7. Button / Symbol description
6. Frost protection
2. Specications & wiring
Contacts: Volt Free
Temperature indicator: °C
Switching dierential: 0.4°C
In built frost protection: 5°C
Blue backlight activated : for 10 secs after any button is pressed
Clock: 24 hours
Keypad lock: O
Operating mode: 5/2 day
5°C
Reset button
Set point increase
Set point decrease
Hold button
Standby button
Set button
OK button
Standby symbol
Keypad lock symbol
Heating ON symbol
Current programme
Day of the week
Program
P3
3. Mounting
Contents
1. Factory default settings
2. Specications & wiring
3. Mounting
4. Installation
5. Wiring diagram
6. Frost protection
7. Button / symbol description
8. Resetting the thermostat
9. Keypad lock and unlock
10. Setting the date, time and operating mode
11. Factory default program settings
12. Adjusting the program settings for 5/2d
13. Temporary override (Manual)
14. Permanent override (Hold)
15. Adjusting the switching dierential
Prior to setting the thermostat, it is neccessary to complete all required settings described in this section.
5. Wiring diagram
Important: Keep this document
Power supply: 230Vac 50Hz
Power consumption: 8 VA
Temp. control range: 5 ... 35°C
Ambient temperature: 0 ... 50°C
Contact rating: 8A 230Vac
Dimensions: 84 x 84 x 30mm
Temperature sensor: NTC 10K Ohm @ 25°C
Switching dierential: Adjustable from 0.2/0.4/0.6/0.8/1.0˚C
Frost protection: Only operational in stand by mode
Slacken the fastening screw on the bottom of the thermostat with a philips
head screwdriver.
The thermostat is hinged and can be opened 180 degrees.
Mount the unit as described in section 3.
Wire the thermostat according to the wiring diagram.
Close the thermostat and tighten the fastening screw.
20170731_AW1077_CDTP2_OpIns_JW
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu,
Cork, T12 W665, Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
sales@ephcontrols.co.uk www.ephcontrols.co.uk
The mounting height should be 1.5 meters above the oor level.
The thermostat should be wall mounted in the room where the heating is to
be controlled.
The place of installation should be chosen so that the sensor can measure the
room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other
heating / cooling sources when mounted.
The unit can be tted to: 1. Recessed conduit boxes
2. Surface mounting boxes
3. Directly on walls.
If mains voltage output is required, terminals L & 2 must be electrically linked.
INTERNAL WIRING DIAGRAM CDTP2 321LN
MAINS
SUPPLY
ON OFFCOM
Frost protection is built into this thermostat, it is pre xed at 5°C and is not
adjustable.
It will only be activated when the thermostat is in the stand by mode and
the room temperature falls below 5°C.
It is necessary to reset the thermostat prior to initial programming.
Press the button on the side of the thermostat.
‘NO’ will appear on the screen.
Press the button.
‘YES’ will appear on the screen.
Press the‘OK’ button to return to normal operation.
RESET