Operating Instructions
Page 1 of 4
4. Installation
1. Factory default settings
How your cylinder thermostat works
5. Frost protection
Temperature indicator: °C
In built frost protection: 5°C - Not adjustable
Clock: 24 hours
Operating mode: 5/2 day
Default temperature setpoint: 60˚C
5°C
Contents
1. Factory default settings
3. Mounting
4. Installation
5. Frost protection
6. LCD symbol / buttons description
7. Resetting the thermostat
8. Keypad lock and unlock
9. Setting the date, time and operating mode
10. Factory program settings
11. Adjusting the program settings for 5/2d
12. Copy Function
13. Adjusting the temperature setpoint
14. Permanent override
15. Boost function
16. Holiday function
17. To connect the RFRP-HW-OT thermostat to an RF1A-OT receiver
18. To disconnect the RFRP-HW-OT thermostat from an RF1A-OT receiver
19. Backlight mode selection
20. Battery low warning
21. Replacing the batteries
22. Installer Menu (without OpenTherm® connected)
Prior to setting the thermostat, it is neccessary to
complete all required settings described in this section.
RFRP-HW-OT
Cylinder Thermostat Wireless
Important: Keep this document
Power supply: 2 x AA Alkaline Battery
Power consumption: 2 mW
Battery replacement: Once a year
Temp. control range: 6 ... 90°C
Ambient temperature: 0 ... 45°C
Dimensions: 130 x 99 x 25mm
Temperature sensor: NTC 100K Ohm @ 25°C
Temperature indication: ˚C
Frost protection: Only operational in OFF mode
Pollution degree: Pollution degree 2
When the thermostat is in the AUTO mode, it will operate according to the
program.
During this time the thermostat will remain on until the temperature setpoint
is reached.
There is only one temperature setpoint which is applied to all programs. The
default temperature setpoint is 60°C.
Frost protection is built into this thermostat.
It will only be activated when the thermostat is in the OFF mode and the
room temperature falls below 5°C.
There is a battery compartment located below the buttons.
Apply downward pressure to remove the cover.
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment.
3a Mounting of temperature sensor
3b Mounting of thermostat
The thermostat should be mounted in a position that will make reading
the display conventient.
ON CYLINDER: To ensure accurate control of your cylinder, the
temperature sensor should be mounted on the bottom 1/3 of the cylinder.
It is essential that the sensing element is in direct contact with the
cylinder and that there is no insulation between it and the cylinder. 60°C is
the temperature level required in order to prevent the build up of
using the provided foil tape.
ON PIPEWORK: To ensure accurate control, the temperature sensor should
be mounted on the pipework as tightly as possible. It is essential that the
sensing element is in direct contact with the pipework and that there is no
insulation between it and the pipework. The temperature sensor can be
20221005_RFRP-HW-OT_OpIns_PK
EPH Controls Ireland
technical@ephcontrols.com www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.com www.ephcontrols.co.uk
7. Resetting the thermostat
6. LCD Symbol / button description
8. Keypad lock and unlock OFF
Manual
mode
Program mode Set Date/ Time
Holiday mode
Copy function
Boost mode
Automatic
mode
(Back)
Set point increase
Set point decrease
Reset button
Operating mode
Current program
Day / Month
Day of the week
Temperature
Battery low symbol
Wireless symbol
Heating on symbol
Keypad lock symbol
Wireless connect button
Current Time
(Boost to time)
10. Factory program settings 5/2d
9. Setting the date, time and operating mode
11. Adjusting the program settings for 5/2d
Press the ‘PROG’ button once.
Programming for Monday to Friday is now selected.
Press the or buttons to adjust the P1 time. Press the‘OK’ button.
Press the or buttons to set ON or OFF status for P1.
Press the ‘OK’ button.
Repeat this process to adjust P2 to P6 times and status.
Press the ‘OK’ button.
Programming for Saturday to Sunday is now selected.
Press the or buttons to adjust the P1 time. Press the‘OK’ button.
Press the ‘OK’ button.
Repeat this process to adjust P2 to P6 times and status.
Press the ‘AUTO’button to return to automatic mode.
While in PROG Mode pressing the ‘PROG’ button will jump from P1-P2 etc
without changing the status.
While in PROG Mode pressing the ‘TIME’ button will jump to the next Day
(block of days).
If 7 D mode is selected, you can program each day of the week with 6
individual times and statuses.
If 24H mode is selected, you can only program each day of the week with
the same 6 times and statuses.
12. Copy function
Mon-Fri
5/2D
P1 P2 P3 P4 P5 P6
06:30 08:00 12:00 14:00 17:30 19:00
ON OFF OFF OFF ON OFF
ON OFF OFF OFF ON OFF
ON OFF OFF OFF ON OFF
ON OFF OFF OFF ON OFF
ON OFF OFF OFF ON OFF
Sat-Sun
08:00 10:00 12:00 14:00 17:30 19:00
Mon-Fri
7D
P1 P2 P3 P4 P5 P6
06:30 08:00 12:00 14:00 17:30 19:00
Sat-Sun
08:00 10:00 12:00 14:00 17:30 19:00
P1 P2 P3 P4 P5 P6
06:30 08:00 12:00 14:00 17:30 19:00
Everyday
24H
Press the ‘TIME
Press the or buttons to adjust the year. Press the‘OK’ button.
Press the or buttons to adjust the month. Press the‘OK’ button.
Press the or buttons to adjust the day. Press the‘OK’ button.
Press the or buttons to adjust the hour. Press the‘OK’ button.
Press the or buttons to adjust the minute. Press the‘OK’ button.
Press the or buttons to adjust from 5/2d to 7d or 24h mode.
Press the ‘AUTO’button or wait 5 seconds and the thermostat will return to
normal operation.
Copy function may only be used if the thermostat is in the 7d mode.
Set the times and temperatures for the day that you wish to copy from in
PROG Mode.
When still on the day press the‘COPY’ button.
The day of the week that you have selected will be shown with‘COPY’
below it.
Press the button to copy the times and temperatures to that day.
Press the button to skip a day.
You can copy to multiple days using the button.
Press the ‘OK’ button when copying has been completed.
6.1 LCD Symbol description
6.2 Button description
Operating Instructions
Page 2 of 4
RFRP-HW-OT
Cylinder Thermostat Wireless
Press the button on the side of the thermostat.
‘rst no’ will appear on the screen.
Press the button.
‘rst yes’will appear on the screen.
Press the ‘OK’ button to reset the thermostat.
RESET
To lock the keypad, press and hold the and buttons for 10 seconds.
will appear on the screen. The keypad is now locked.
To unlock the keypad, press and hold the and buttons for 10 seconds.
will disappear from the screen. The keypad is now unlocked.
AUTO MAN OFF PROG TIME HOL COPY BOOST OK
20221005_RFRP-HW-OT_OpIns_PK
EPH Controls Ireland
technical@ephcontrols.com www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.com www.ephcontrols.co.uk
When in Auto or Man mode, press the or buttons to adjust the
temperature setpoint.
Press Ok or after 5 seconds the thermostat will operate to this
temperature.
13. Adjusting the temperature setpoint
14. Permanent override
Press the ‘MAN’ button to enter Manual Mode (Permanent Override).
‘MAN’ will appear on the screen.
Press the or buttons to adjust the temperature setpoint.
Press ‘OK
thermostat will operate in this permanent override.
The thermostat will operate in MAN mode until the mode is changed.
To cancel permanent override, press the‘OFF’ button or press the
‘AUTO’ button.
20. Battery low warning
When the batteries are almost empty, the symbol will appear on
the screen.
The batteries must now be replaced or the unit will shut down.
16. Holiday function
15. Boost function
The thermostat can be boosted for 1, 2 or 3 hours while the thermostat is
operating in all modes except for holiday mode.
Press the ‘BOOST’ button 1, 2 or 3 times, the time that the boost will be
If you do not press any other button the boost will activate to the time on
the screen after 5 seconds.
Press the ‘OK’ button or wait for 5 seconds to enter BOOST Mode.
‘BOOST TO’will now be displayed on the screen with the time that it is
activated to displayed above this text.
Press the ‘BOOST’ button again to deactivate the boost.
you select .
Press the ‘HOL’ button, ‘HOLIDAY FROM’will appear on screen.
Press the or buttons to adjust the day. Press the‘OK’ button.
Press the or buttons to adjust the month. Press the‘OK’ button.
Press the or buttons to adjust the year. Press the‘OK’ button.
Press the or buttons to adjust the hour. Press the‘OK’ button.
‘HOLIDAY TO’ will appear on screen.
Press the or buttons to adjust the day. Press the‘OK’ button.
Press the or buttons to adjust the month. Press the‘OK’ button.
Press the or buttons to adjust the year. Press the‘OK’ button.
Press the or buttons to adjust the hour. Press the‘OK’ button.
The thermostat will now return to the mode it was in before the Holiday
settings were entered.
To cancel Holiday mode, press the‘HOL’ button.
There are two settings for selection. The factory default setting is AUTO.
OFF The backlight is permanently OFF.
AUTO On pressing any button the backlight stays on for 5 seconds.
To adjust the backlight setting, lower the cover on the front of the unit.
Press the ‘OK’ button for 5 seconds.
Press either the or buttons to select the OFF or AUTO mode.
Press the‘OK’ button.
AUTO
19. Backlight mode selection
Press the button on the RF1A-OT receiver.
17. To connect the RFRP-HW-OT thermostat to an
RF1A-OT receiver
Connect
Press the button.
The thermostat will show “nOE”followed by“---”
Once an RF connection has been established the thermostat will show ‘r01’
on the LCD screen.
Press the ‘OK
The thermostat is now connected to the RF1A-OT receiver.
Connect
On the RFRP-HW-OT thermostat:
On the RF1A-OT receiver:
Please note, If you are installing a CP4-HW-OT, the RFRP-HW-OT thermostat
and the RF1A-OT receiver will have a pre-established RF connection so it is
not necessary to carry out the RF connection process below.
Connect
Connect
18. To disconnect the RFRP-HW-OT thermostat from an
RF1A-OT receiver
Press the button.
The thermostat will begin to search through the RF channels.
Press and hold the‘Copy’button for 10 seconds.
‘Adr’will appear on the screen of the thermostat.
Press the ‘OK’ button twice to complete the unpairing process.
The thermostat RFRP-HW-OT is now disconnected from the receiver RF1A-OT.
18.1 On the RFRP-HW-OT thermostat:
18.1 On the RF1A-OT receiver:
Red & green lights if using as a hub receiver.
Press and hold connect for about 10 seconds, the receiver will then stop
The RF connection is now cleared.
Operating Instructions
Page 3 of 4
This can be done from either the thermostat or the receiver.
RFRP-HW-OT
Cylinder Thermostat Wireless
20221005_RFRP-HW-OT_OpIns_PK
EPH Controls Ireland
technical@ephcontrols.com www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.com www.ephcontrols.co.uk
P0 1: Mode (Normal)
P0 4: Calibration
P0 5: Frost Protection
Exit
P0 1: Mode (Normal)
P0 3: Hysteresis HOn and HOFF
P0 4: Calibration
Normal Mode (Nor)
22. Installer menu (without OpenTherm® connected)
To access the installer menu, you must hold Prog and OK for 5 seconds.
When in the installer menu, press + - and OK to navigate and select. Use
AUTO, MAN or OFF to go back a step.
When the thermostat is in Normal mode, the thermostat will try to reach the
target temperature after the program changes.
Example: Program 1 on the thermostat is set to ON for 06:30am, the
temperature set point is 60˚C and the cylinder temperature is 30˚C. The
thermostat will start heating the cylinder at 06:30am and the cylinder
temperature will start to increase then. Until the setpoint is reached or the on
status end.
21. Replacing the batteries
thermostat when the temperature is rising and falling.
HOn is the fall in temperature – Default – 5°C. This will allow a fall of 5°C
from the setpoint before the thermostat turns on again.
HOFF is the rise in temperature – Default – 0.0°C. This will allow the
temperature to rise 0°C above its setpoint.
This menu allows the installer to re-calibrate the thermostat. The current
temperature will be displayed on the screen and can be adjusted by
pressing the up and down buttons.
P0 5: Frost Protection
This menu allows the installer to activate or de-activate frost protection.
When frost protection is activated the thermostat will switch on the boiler
when the temperature drops below 5˚C.
Exit
This menu allows the installer to return to the main interface. It is also
possible to exit the installer menu by pressing AUTO, MAN or OFF whilst in
the installer menu.
ON
Operating Instructions
Page 4 of 4
RFRP-HW-OT
Cylinder Thermostat Wireless
There is a battery compartment located below the buttons.
Apply downward pressure to remove the cover.
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment.
20221005_RFRP-HW-OT_OpIns_PK
EPH Controls Ireland
technical@ephcontrols.com www.ephcontrols.com
EPH Controls UK
technical@ephcontrols.com www.ephcontrols.co.uk

Other EPH Controls Thermostat manuals

EPH Controls HDT Operating instructions

EPH Controls

EPH Controls HDT Operating instructions

EPH Controls CDT2-24 User manual

EPH Controls

EPH Controls CDT2-24 User manual

EPH Controls RFC User manual

EPH Controls

EPH Controls RFC User manual

EPH Controls RFRB User manual

EPH Controls

EPH Controls RFRB User manual

EPH Controls CRTP2 Operating instructions

EPH Controls

EPH Controls CRTP2 Operating instructions

EPH Controls R37 User manual

EPH Controls

EPH Controls R37 User manual

EPH Controls CDTP2 User manual

EPH Controls

EPH Controls CDTP2 User manual

EPH Controls RFRA User manual

EPH Controls

EPH Controls RFRA User manual

EPH Controls COMBIPACK4 Operating instructions

EPH Controls

EPH Controls COMBIPACK4 Operating instructions

EPH Controls RFRP User manual

EPH Controls

EPH Controls RFRP User manual

EPH Controls TRFPi2 User manual

EPH Controls

EPH Controls TRFPi2 User manual

EPH Controls CDC2 Operating instructions

EPH Controls

EPH Controls CDC2 Operating instructions

EPH Controls HRT Operating instructions

EPH Controls

EPH Controls HRT Operating instructions

EPH Controls CDTP2 User manual

EPH Controls

EPH Controls CDTP2 User manual

EPH Controls T27-RFi User manual

EPH Controls

EPH Controls T27-RFi User manual

EPH Controls curve crtp User manual

EPH Controls

EPH Controls curve crtp User manual

EPH Controls HRT Operating instructions

EPH Controls

EPH Controls HRT Operating instructions

EPH Controls CP4B Operating instructions

EPH Controls

EPH Controls CP4B Operating instructions

EPH Controls CDT2-24 User manual

EPH Controls

EPH Controls CDT2-24 User manual

EPH Controls RDTP Operating instructions

EPH Controls

EPH Controls RDTP Operating instructions

EPH Controls CP4M Operating instructions

EPH Controls

EPH Controls CP4M Operating instructions

EPH Controls RFPi2 User manual

EPH Controls

EPH Controls RFPi2 User manual

EPH Controls E 15402 User manual

EPH Controls

EPH Controls E 15402 User manual

EPH Controls EDBS Operating instructions

EPH Controls

EPH Controls EDBS Operating instructions

Popular Thermostat manuals by other brands

Home Automation Omnistat RC-81 owner's manual

Home Automation

Home Automation Omnistat RC-81 owner's manual

Honeywell TRADELINE Q7300L installation instructions

Honeywell

Honeywell TRADELINE Q7300L installation instructions

tado° Smart Thermostat installation guide

tado°

tado° Smart Thermostat installation guide

Roca RX-100 Installation, assembly and operating instructions

Roca

Roca RX-100 Installation, assembly and operating instructions

Honeywell T410A manual

Honeywell

Honeywell T410A manual

ComfortNET CTK04 operating manual

ComfortNET

ComfortNET CTK04 operating manual

ICM Controls SC710LV Installation, operation & application guide

ICM Controls

ICM Controls SC710LV Installation, operation & application guide

Ferroli ZU0800013 Installation & user's instructions

Ferroli

Ferroli ZU0800013 Installation & user's instructions

Buderus Logamatic EMS RC35 operating instructions

Buderus

Buderus Logamatic EMS RC35 operating instructions

Tekmar tekmarNet 532 Installation & operation manual

Tekmar

Tekmar tekmarNet 532 Installation & operation manual

HeatMat Programmable Thermostat user manual

HeatMat

HeatMat Programmable Thermostat user manual

ardex FLEXBONE HEAT Non-Programmable Thermostat quick start guide

ardex

ardex FLEXBONE HEAT Non-Programmable Thermostat quick start guide

Element4 E-Save user manual

Element4

Element4 E-Save user manual

Honeywell EasyStat T8400A1002 Gebruiksaanwijzing

Honeywell

Honeywell EasyStat T8400A1002 Gebruiksaanwijzing

PHASELINER TT097 user guide

PHASELINER

PHASELINER TT097 user guide

Danfoss TP5000 RF Si installation instructions

Danfoss

Danfoss TP5000 RF Si installation instructions

Honeywell THP2400A1019 installation guide

Honeywell

Honeywell THP2400A1019 installation guide

COLDBUSTER FLOORHEATING MWD5 QUICK REFERENCE USER MANUAL

COLDBUSTER FLOORHEATING

COLDBUSTER FLOORHEATING MWD5 QUICK REFERENCE USER MANUAL

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.