ESAB COOL 1 User manual

0740 800 210 Valid for serial no. 033-xxx-xxxx101102
COOL 1
Service manual

S0740 800 210/E101102/P18
- 2 -TOCe
Rights reserved to alter specifications without notice.
READ THIS FIRST 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TECHNICAL DATA 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WIRING DIAGRAM 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component description 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COOL1 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF OPERATION 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Cooling unit 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5AP1:1 Monitoring the coolant flow 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5AP1:2 Pump motor and fan ON/OFF 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5AP1 Component positions 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERVICE INSTRUCTIONS 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What is ESD? 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service aid 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTRUCTIONS 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing to welding equipment 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly instructions 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections and control devices 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Coolant connection 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Water flow guard 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection and cleaning 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filling the coolant 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Caracteristics 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPARE PARTS 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTES 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

S0740 800 210/E101102/P18
- 3 -
ck10_00
READ THIS FIRST
Maintenance and repair work should be performed by an experienced person, and
electrical work only by a trained electrician. Use only recommended replacement parts.
This service manual is intended for use by technicians with electrical/electronic training for
help in connection with fault-tracing and repair.
Use the wiring diagram as a form of index for the description of operation. The circuit
boards are divided into numbered blocks, which are described individually in more detail in
the description of operation. Component names in the wiring diagram are listed in the
component description.
Use the spare parts list as a guide to where the components are located in the equipment.
The spare parts list is published as a separate document, see page 16.
This manual contains details of design changes that have been made up to and including
October 2010.
The manual is valid for COOL 1 with serial no. 033-xxx-xxxx
The COOL 1 is designed and tested in accordance with international and European
standards IEC/EN 60974.
On completion of service or repair work, it is the responsibility of the person(s)
performing the work to ensure that the product still complies with the requirements of
the above standard.
CAUTION!
Read and understand the instruction manual before
installing or operating.
CAUTION !
STATIC ELECTRICITY can damage circuit
boards and electronic components.
SObserve precautions for handling electrostatic-
sensitive devices.
SUse proper static-proof bags and boxes.
ESD

S0740 800 210/E101102/P18
- 4 -
ck10_00
TECHNICAL DATA
COOL 1
Power consumption 24V DC / 2A
Cooling power 1.3 kW (Rating at 40 K and 1 l/min)
Equivalent continuous A-weighted
sound pressure level
< 70 dB (A)
Coolant Ready mixed (50% water and 50% mono-ethylene glycol)
Coolant quantity 4.5 l
Maximum flow 2.0 l/min
Maximum pressure 4 bar
Operating temperature -10° to +40°C
Transportation temperature -20° to +55°C
Dimensions lxwxh 610 x 256 x 256 mm
Weight empty 12 kg
Enclosure class IP23
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
WIRING DIAGRAM
Component description
Component Description
5Cooling unit
5AP1 Circuit board with control electronics
5M1 Pump with motor, 24V DC
5S1 Coolant pressure switch (enclosed in pump 5M1)
5EV1 Cooling fan, 24V DC
5SL1 Flow guard. Monitoring coolant flow (option)
5XP.. Plug connector (Pin)
5XS.. Socket connector (Sleeve)
5XT.. Terminal block

S0740 800 210/E101102/P18
- 5 -
ck10_00
COOL1

S0740 800 210/E101102/P18
- 6 -
ck10_05
DESCRIPTION OF OPERATION
This description of operation describes the function of circuit boards and other components
in the equipment.
5 Cooling unit
5AP1:1 Monitoring the coolant flow
Circuit diagram for coolant flow guard
COOL1 is prepared for optional coolant flow monitoring. Replace the jumper cable 513 with
the flow guard sensor, 5SL1, and connect it to terminal block 5XT1 (CN4) on cooling unit
board, 5AP1. The sensor switch opens at flow rate < 0.7 l/min. The MMC panel of the
system displays fault code 29 ,(no cooling water flow), if the input to the processor is high.
(Measure at point SP3 on 20AP1)
Supervision of hoses connection, ELP (ESAB Logic Pump) is not installed in COOL1.
5AP1:2 Pump motor and fan ON/OFF
The pump motor, 5M1, and cooling fan, 5EV1, are connected in parallell and powered from
the power supply board, 2AP3, in the power source. The power is 25V DC and named
25V_WP in the cooling unit board, 5AP1.
An output from the processsor on control board 20AP1 connects input 20XS5:2 (WP2) to
0V. (Measure at point SP1 on 20AP1). Transistor Q2 in cooling unit board, 5AP1, connects
pump motor and fan to 0V, and the pump and fan start.
The pump, 5M1, has an enclosed coolant pressure switch, 5S1, which switches off the
power to the pump motor if the coolant pressure is too high. This can occur if a hose is
folded which make flow to fail or stop. The cooling fan however is still powered and running.

S0740 800 210/E101102/P18
- 7 -
ck10_05
Pump motor and fan ON/OFF
Circuit diagram for pump motor and cooling fan

S0740 800 210/E101102/P18
- 8 -
ck10_05
5AP1 Component positions
Component positions on the cooling unit board, 5AP1.
Terminal block CN4 is also named 5XT1 in the diagram.

S0740 800 210/E101102/P18
- 9 -
ck10f2
SERVICE INSTRUCTIONS
What is ESD?
A sudden transfer or discharge of static electricity from one object to another. ESD stands for
Electrostatic Discharge.
How does ESD damage occur?
ESD can cause damage to sensitive electrical components, but is not dangerous to people.
ESD damage occurs when an ungrounded person or object with a static charge comes into
contact with a component or assembly that is grounded. A rapid discharge can occur,
causing damage. This damage can take the form of immediate failure, but it is more likely
that system performance will be affected and the component will fail prematurely.
How do we prevent ESD damage?
ESD damage can be prevented by awareness. If static electricity is prevented from building
up on you or on anything at your work station, then there cannot be any static discharges.
Nonconductive materials (e.g. fabrics), or insulators (e.g. plastics) generate and hold static
charge, so you should not bring unnecessary nonconductive items into the work area.
It is obviously difficult to avoid all such items, so various means are used to drain off any
static discharge from persons to prevent the risk of ESD damage. This is done by simple
devices: wrist straps, connected to ground, and conductive shoes.
Work surfaces, carts and containers must be conductive and grounded. Use only antistatic
packaging materials. Overall, handling of ESD-sensitive devices should be minimized to
prevent damage.
CAUTION !
STATIC ELECTRICITY can damage circuit
boards and electronic components.
SObserve precautions for handling electrostatic-
sensitive devices.
SUse proper static-proof bags and boxes.
ESD
Service aid
Antistatic service kit
Ordering no. 0740 511 001
The kit makes it easier to protect sensitve
components from electrostatic discharge.
Contents:
SA conductive mat (size 610 x 610 mm)
SA 1.5 metre long ground cable with a
crocodile clip
SAn adjustable wrist strap and cable with
an inbuilt protective resistor
Antistatic service kit

S0740 800 210/E101102/P18
- 10 -
ck10i1
INSTRUCTIONS
This chapter is an extract from the instruction manual for the COOL1.
SAFETY
CAUTION!
Read and understand the instruction manual before
installing or operating.
INSTALLATION
The installation must be executed by a professional.
Location
Position the cooling unit such that its air inlets and outlets are not obstructed.
Power supply and control
COOL1 is powered and controlled from the power source via socket connector XS4 in the
bottom of the power source. The plug connector 5XP1 on top of the cooler is connected to
XS4.
Installing to welding equipment
See assembly instructions on page 11.

S0740 800 210/E101102/P18
- 11 -
ck10i1
Assembly instructions
COOL1 + Aristo 300, Aristo 400 or Aristo 500

S0740 800 210/E101102/P18
- 12 -
ck10i1
Water flow guard (Option)

S0740 800 210/E101102/P18
- 13 -
ck10i1
OPERATION
General safety regulations for the handling of the equipment can be found in the
instruction manual. Read through before you start using the equipment!
Connections and control devices
1Filling the coolant
2BLUE connection for coolant from cooling
unit
3Connection RED for coolant (return) to
cooling unit.
Coolant connection
For problem free operation it is recommended that the height from the cooling unit to the water-
cooled MIG/MAG gun is maximum 8.5 m.
Water flow guard
The water flow guard blocks the power source if the coolant stops flowing(< 0.7 l/min.). The
water flow guard is an accessory.
MAINTENANCE
Regular maintenance is important for safe, reliable operation.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates.
CAUTION!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any faults.

S0740 800 210/E101102/P18
- 14 -
ck10i1
Inspection and cleaning
WARNING!
The mains supply must be disconnected before cleaning!
Dust, grinding swarf etc The air stream through the cooling unit carries particles that
become trapped in the cooling element, particularly in dirty working environments. This
results in reduced cooling capacity. For this reason, blow clean using compressed air at
regular intervals.
The coolant system - The recommended coolant must be used in the system otherwise
clumps can be created that block the pump , water connections or elements. Flushing can
only be performed via red water connection. Then drain the tank manually, i.e. empty via
the tank's filing hole.
Filling the coolant
ESAB's coolant is recommended for use. See accessories in instruction manual.
SFill with coolant.
(The fluid level must not exceed the
upper marking but neither must it be
below the lower marking)
Note! Coolant must be topped up if
connecting a welding gun or coolant
hoses that are 5 metres in length or
longer. When adjusting the water level by
topping up, the coolant hoses do not
need to be disconnected.
The temperature of the coolant must not exceed 70°C
CAUTION!
The coolant must be handled as chemical waste.

S0740 800 210/E101102/P18
- 15 -
ck10i1
Caracteristics
Pump data
p = Pump pressure (MPa)
Q = Flow rate (l/min)

S0740 800 210/E101102/P18
- 16 -
ck10i1
Cooling caracteristic (at 1 l/min)
P = Power (kW)
K = Temperature difference between inlet water temperature and ambient temperature (K)
SPARE PARTS
The spare parts list is published in a separate document that can be downloaded from the
internet: www.esab.com
Filename Product
0459 839 048 COOL 1

S0740 800 210/E101102/P18
- 17 -
notes
NOTES

ESAB AB
SE-695 81 LAXÅ
SWEDEN
Phone +46 584 81 000
www.esab.com
081016
ESAB subsidiaries and representative offices
Europe
AUSTRIA
ESAB Ges.m.b.H
Vienna-Liesing
Tel: +43 1 888 25 11
Fax: +43 1 888 25 11 85
BELGIUM
S.A. ESAB N.V.
Brussels
Tel: +32 2 745 11 00
Fax: +32 2 745 11 28
THE CZECH REPUBLIC
ESAB VAMBERK s.r.o.
Vamberk
Tel: +420 2 819 40 885
Fax: +420 2 819 40 120
DENMARK
Aktieselskabet ESAB
Herlev
Tel: +45 36 30 01 11
Fax: +45 36 30 40 03
FINLAND
ESAB Oy
Helsinki
Tel: +358 9 547 761
Fax: +358 9 547 77 71
FRANCE
ESAB France S.A.
Cergy Pontoise
Tel: +33 1 30 75 55 00
Fax: +33 1 30 75 55 24
GERMANY
ESAB GmbH
Solingen
Tel: +49 212 298 0
Fax: +49 212 298 218
GREAT BRITAIN
ESAB Group (UK) Ltd
Waltham Cross
Tel: +44 1992 76 85 15
Fax: +44 1992 71 58 03
ESAB Automation Ltd
Andover
Tel: +44 1264 33 22 33
Fax: +44 1264 33 20 74
HUNGARY
ESAB Kft
Budapest
Tel: +36 1 20 44 182
Fax: +36 1 20 44 186
ITALY
ESAB Saldatura S.p.A.
Mesero (Mi)
Tel: +39 02 97 96 81
Fax: +39 02 97 28 91 81
THE NETHERLANDS
ESAB Nederland B.V.
Amersfoort
Tel: +31 33 422 35 55
Fax: +31 33 422 35 44
NORWAY
AS ESAB
Larvik
Tel: +47 33 12 10 00
Fax: +47 33 11 52 03
POLAND
ESAB Sp.zo.o.
Katowice
Tel: +48 32 351 11 00
Fax: +48 32 351 11 20
PORTUGAL
ESAB Lda
Lisbon
Tel: +351 8 310 960
Fax: +351 1 859 1277
SLOVAKIA
ESAB Slovakia s.r.o.
Bratislava
Tel: +421 7 44 88 24 26
Fax: +421 7 44 88 87 41
SPAIN
ESAB Ibérica S.A.
Alcalá de Henares (MADRID)
Tel: +34 91 878 3600
Fax: +34 91 802 3461
SWEDEN
ESAB Sverige AB
Gothenburg
Tel: +46 31 50 95 00
Fax: +46 31 50 92 22
ESAB international AB
Gothenburg
Tel: +46 31 50 90 00
Fax: +46 31 50 93 60
SWITZERLAND
ESAB AG
Dietikon
Tel: +41 1 741 25 25
Fax: +41 1 740 30 55
North and South America
ARGENTINA
CONARCO
Buenos Aires
Tel: +54 11 4 753 4039
Fax: +54 11 4 753 6313
BRAZIL
ESAB S.A.
Contagem-MG
Tel: +55 31 2191 4333
Fax: +55 31 2191 4440
CANADA
ESAB Group Canada Inc.
Missisauga, Ontario
Tel: +1 905 670 02 20
Fax: +1 905 670 48 79
MEXICO
ESAB Mexico S.A.
Monterrey
Tel: +52 8 350 5959
Fax: +52 8 350 7554
USA
ESAB Welding & Cutting Products
Florence, SC
Tel: +1 843 669 44 11
Fax: +1 843 664 57 48
Asia/Pacific
CHINA
Shanghai ESAB A/P
Shanghai
Tel: +86 21 2326 3000
Fax: +86 21 6566 6622
INDIA
ESAB India Ltd
Calcutta
Tel: +91 33 478 45 17
Fax: +91 33 468 18 80
INDONESIA
P.T. ESABindo Pratama
Jakarta
Tel: +62 21 460 0188
Fax: +62 21 461 2929
JAPAN
ESAB Japan
Tokyo
Tel: +81 45 670 7073
Fax: +81 45 670 7001
MALAYSIA
ESAB (Malaysia) Snd Bhd
USJ
Tel: +603 8023 7835
Fax: +603 8023 0225
SINGAPORE
ESAB Asia/Pacific Pte Ltd
Singapore
Tel: +65 6861 43 22
Fax: +65 6861 31 95
SOUTH KOREA
ESAB SeAH Corporation
Kyungnam
Tel: +82 55 269 8170
Fax: +82 55 289 8864
UNITED ARAB EMIRATES
ESAB Middle East FZE
Dubai
Tel: +971 4 887 21 11
Fax: +971 4 887 22 63
Representative offices
BULGARIA
ESAB Representative Office
Sofia
Tel/Fax: +359 2 974 42 88
EGYPT
ESAB Egypt
Dokki-Cairo
Tel: +20 2 390 96 69
Fax: +20 2 393 32 13
ROMANIA
ESAB Representative Office
Bucharest
Tel/Fax: +40 1 322 36 74
RUSSIA
LLC ESAB
Moscow
Tel: +7 095 543 9281
Fax: +7 095 543 9280
LLC ESAB
St Petersburg
Tel: +7 812 336 7080
Fax: +7 812 336 7060
Distributors
For addresses and phone
numbers to our distributors in
other countries, please visit our
home page
www.esab.com
Table of contents
Other ESAB Water Dispenser manuals