September 2013, rev A © 2013 Electronic Solutions, Inc. Page 1 of 4
M50Q 230VAC series, v4.7
Motor
Quick Setup
Electronic Solutions, Inc.
1355 Horizon Avenue
Lafayette, CO 80026 U.S.A.
www.elec-solutions.com
Tel: (303) 469-9322
Introduction
This document explains how to set motor limits (end positions) and how to connect the low voltage data cables
to an M50Q series motor. Refer to the M50Q 230VAC Specifications document for technical details.
Products
M50Q 230VAC 50Hz series motors —M50Q 626B, M50Q 1530B
NOTE: M50Q part numbers ending with “A” are 120VAC and those ending with “B” are 230VAC.
Before You Start
On power-up: LEDs will blink GREEN YELLOW
CW is clockwise rotation looking at the motor from the head end, CCW is counterclockwise.
Be sure the motor is connected to continuous AC power.
An M50Q series motor ships from the factory with a randomized RQ address between C00 and ZZZ and no
limits set.
The M50Q series motor has a 3-conductor, keyed AC power connection in the motor head for connecting the
included AC power cord, PC M40/50 UNIV.
The M50Q series motor has a 5-conductor, keyed low voltage, data connection (RQ Bus and RP Bus) for
use with the CBL 6 FT QE QM, CBL 1 FT QE QM, or RE 1 FT QM, each sold separately. This cable must be
connected after the AC power connection is in place and AC power is applied.
The M50Q series motor has a 3-conductor, keyed low voltage, manual input (dry contact) connection for use
with CBL 6 FT DM, sold separately. This cable must be connected after the AC power connection is in place
and AC power is applied.
The M50Q series motor has three clear buttons with internal LEDs:
oButton 1, RED LED button, with one groove, operates the motor counterclockwise [CCW].
oButton 2, GREEN LED button, with two grooves, operates the motor clockwise [CW].
oCenter Button, YELLOW LED button with no groove, used to set and clear motor options.
If any button is pressed while the motor is moving, the motor will stop.
Use an SP1E3Q when connecting more than two RQ-enabled motors (M40Q or M50Q).
Refer to the M40Q and M50Q Typical Wiring Diagram on page 4 for an example of wiring.
M50Q 230VAC series Motor Quick Setup v4.7
www.elec-solutions.com © 2013 Electronic Solutions, Inc. Page 2 of 4
Power-Up the M50Q
The M50Q series motor includes a keyed 3-conductor AC power connection in the head end of the motor.
Securely connect the included AC Power Cord (PC M40/50 UNIV) to this connector. Installer shall
connect appropriate AC power plug to blunt-cut end.
Motor Configuration
Set Motor Limits:
When power is first applied to a factory default motor, the motor is in “Set limit mode.” The mode is identified
by a flashing RED LED on Button 1 and a flashing GREEN LED on Button 2.
1. To set the CCW limit, press either Button 1 (CCW motion) or Button 2 (CW motion), to operate the
motor to the desired CCW limit.
2. Once the desired CCW limit position has been reached, press and hold the Center Button first and then
also press and hold Button 1 (flashing RED) until the RED LED turns off and the Center Button
YELLOW LED lights solid (approx. 2 seconds) then immediately release both buttons to set the CCW
limit.
3. The YELLOW LED lights solid for three seconds to acknowledge the “Set CCW limit to here” operation,
then the motor goes into “Set CW limit mode” and the GREEN LED on Button 2 will be flashing.
4. Press either Button 1 or Button 2 to operate the motor to the desired CW limit.
5. Once the desired CW limit position has been reached, press and hold the Center Button first and then
also press and hold Button 2 (flashing GREEN) until the GREEN LED turns off and the Center Button
YELLOW LED lights solid (approx. 2 seconds) then immediately release both buttons to set the CW
limit.
6. The YELLOW LED lights solid for three seconds to acknowledge the “Set CW limit to here” operation.
7. Both motor limits are set and all LEDs are off.
Clear both Limits:
1. Press and hold the Center Button until the YELLOW LED lights solid (approx. 10 seconds) then release
the Center Button.
2. The LED in Button 1 begins flashing RED and the LED in Button 2 begins flashing GREEN. See "Set
Motor Limits" above.
Clear CCW Motor Limit:
1. Press and hold the Center Button first and then also press and hold Button 1 until the Center Button
YELLOW LED lights (approx. 2 seconds) and then turns off (approx. 3 seconds later) then release both
buttons.
2. The LED in Button 1 begins flashing RED. See "Set Motor Limits" above.
Clear CW Motor Limit:
1. Press and hold the Center Button first and then also press and hold Button 2 until the Center Button
YELLOW LED lights (approx. 2 seconds) and then turns off (approx. 3 seconds later) then release both
buttons.
2. The LED in Button 2 begins flashing GREEN. See "Set Motor Limits" above.
Adjust either Motor Limit:
1. Press either Button 1 (CCW motion) or Button 2 (CW motion), to operate the motor to the desired
position.
2. Once the desired limit position is reached, press and hold the Center Button first and then also press
and hold the appropriate button —Button 1 (CCW limit) or Button 2 (CW limit) —until the YELLOW
LED lights (approx. 2 seconds) then immediately release both buttons to set the corresponding motor
limit.
M50Q 230VAC series Motor Quick Setup v4.7
www.elec-solutions.com © 2013 Electronic Solutions, Inc. Page 3 of 4
Toggle Motor Direction:
1. Simultaneously press and hold both Button 1 (CCW) and Button 2 (CW), until both the RED and
GREEN LEDs light (approx. 5 seconds) then release both buttons.
2. If motor direction is such that the Open command is CW, then the LEDs will blink RED then GREEN. If
motor direction is such that the Open command is CCW, then the LEDs will blink GREEN then RED.
Determine Motor Version:
1. Power cycle the motor to determine motor firmware version.
2. On power-up, LEDs will blink GREEN YELLOW.
Low Voltage Cable Connections
IMPORTANT: Each of the Low Voltage cables must be connected after the AC power connection is
in place and AC power is applied.
Manual inputs (dry contact) using 3-conductor, keyed low voltage cable:
If you plan to use relays from a building automation system, a Single Pole Double Throw (SPDT) manual input
(dry contact) switch, or similar device, for “contact closure control” of an M50Q motor, you will need to connect
the CBL 6 FT DM, sold separately.
1. Connect the CBL 6 FT DM to the 3-conductor, low voltage manual input (dry contact) connection, and
wire it to the contact closure control —the center wire is COMMON.
IMPORTANT: When inserting the connector into the motor, do not use a metal tool to push the
connector into the socket.
2. Verify desired operation from the contact closure device.
RP Bus / RQ Bus using 5-conductor, keyed low voltage cable:
If you plan to utilize an RQ Bridge, Infrared Eye, or other RP/RQ accessory to control an M50Q motor, you will
need to connect the CBL 6 FT QE QM, or the CBL 1FT QE QM, each sold separately.
1. Connect the cable to the 5-conductor, low voltage data connection, and connect the modular plug into
the RP or RQ bus.
IMPORTANT: When inserting the connector into the motor, do not use a metal tool to push the
connector into the socket.
NOTE: the modular plug is an EYE as far as an RP bus connection is concerned.
2. Verify desired functions from an RP or RQ input device or accessory.
DO NOT attempt to send RS-232, RS-422, or contact closure to this connection.
If you plan to use an Infrared Eye to control an M50Q motor, you can connect the RE 1 FT QM, sold separately.
1. Connect the Infrared Eye to the 5-conductor, low voltage data connection.
IMPORTANT: When inserting the connector into the motor, do not use a metal tool to push the
connector into the socket.
2. Verify desired operation from the IR control.
M50Q 230VAC series Motor Quick Setup v4.7
www.elec-solutions.com © 2013 Electronic Solutions, Inc. Page 4 of 4
M40Q and M50Q Typical Wiring Diagram
To RS-232 Input
To Optional Input Device
CBL 6 FT DM 3-conductor for Manual Inputs
CBL 6 FT QE QM or CBL 1 FT QE QM 5-conductor for RQ Bus
PC M40/50 US or PC M40/50 UNIV AC Power cord for M40 and M50
RQ Bus cable
5-conductor 26AWG or better wire
(flat 5-conductor,
or non-shielded Cat5e cable)
SP1E3QB
Manual Input Local Switch
(or other Low Voltage
/ Dry Contact device)
M50Q
M40Q
Connect to appropriately
grounded AC Power with
Branch Circuit Protection
M50Q
M40Q
SP1E3QB
Connect to appropriately
grounded AC Power with
Branch Circuit Protection

This manual suits for next models

2

Other ESI Engine manuals

ESI M50Q Series Specification sheet

ESI

ESI M50Q Series Specification sheet

ESI M50Q 230VAC Series Specification sheet

ESI

ESI M50Q 230VAC Series Specification sheet

Popular Engine manuals by other brands

Westerbeke W-13 Operator's manual

Westerbeke

Westerbeke W-13 Operator's manual

MTU 12V4000L62FB operating instructions

MTU

MTU 12V4000L62FB operating instructions

Yanmar 6HYM-WET Operation manual

Yanmar

Yanmar 6HYM-WET Operation manual

Kohler COMMAND CH18-745 Service manual

Kohler

Kohler COMMAND CH18-745 Service manual

Westerbeke 82B FOUR Specifications

Westerbeke

Westerbeke 82B FOUR Specifications

MTU 12V2000Gx6 series operating instructions

MTU

MTU 12V2000Gx6 series operating instructions

LRP XTEC ZR.32 SPEC.2 PULLSTART user guide

LRP

LRP XTEC ZR.32 SPEC.2 PULLSTART user guide

TOPMAQ DH163 owner's manual

TOPMAQ

TOPMAQ DH163 owner's manual

Becker P4-30 Assembly and operating instructions

Becker

Becker P4-30 Assembly and operating instructions

IEF Werner Module 68 operating instructions

IEF Werner

IEF Werner Module 68 operating instructions

Yanmar 2V Series Operation manual

Yanmar

Yanmar 2V Series Operation manual

FAAC TM2 ERX manual

FAAC

FAAC TM2 ERX manual

OLI High vision user manual

OLI

OLI High vision user manual

Wilesco D 48 manual

Wilesco

Wilesco D 48 manual

Newland NLS-EM1300-LD Integration guide

Newland

Newland NLS-EM1300-LD Integration guide

ORION TELESCOPES & BINOCULARS AstroTrack 7812 instruction manual

ORION TELESCOPES & BINOCULARS

ORION TELESCOPES & BINOCULARS AstroTrack 7812 instruction manual

SOMFY Oximo WT instructions

SOMFY

SOMFY Oximo WT instructions

Volvo Penta MD1B Workshop manual

Volvo Penta

Volvo Penta MD1B Workshop manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.