9
3. Insert the AA batteries provided and replace the front
cover of the thermostat.
Fitting the Receiver
Installation
1. Loosen the screws on the back-plate and remove from
the Unit.
2. Fix the back-plate, terminals at the top, either direct
onto a flat wall using wall plugs and screws or on a flush
mounting single conduit box. Route the wires through
the back of the wall plate and fit the wires to the wall-
plate in accordance with the relevant diagram and in
accordance with I.E.E. regulations.
3. Fit the Unit onto back-plate, and tighten the screws.
Ensure an appropriate fuse is fitted to the circuit before
reconnecting to the mains supply.
Commissioning/Configuring
1. If the receiver and thermostat have been supplied as
a kit, the units have already been paired in the factory
and no pairing is needed.
2. Power up the receiver and both lights should come on
for a few seconds.
3. Press and hold M/A (Manual/Auto) button 1(See page
10) for approximately 10 seconds until the MANUAL
light 2(See page 10) begins to flash (green).
4. Insert batteries in the thermostat, turn dial up to 5 and
remove dial.
5. Press and hold the black button until the receiver light
goes off.
6. To check it is paired, turn the thermostat above room