eSSL BG-S-105 User manual

www.esslsecurity.com
User Manual
BG-S-105& BG-SC-300

1.1 Descriptions of Panel
1.2 Technical Specifications
1.3 Definitions of Buttons
Open/Increase Value Stop/Set/Save Close/Decrease Value
Close/Decrease Value
Open/Increase Value
Stop/Set Save/
AC 220V 50/60Hz
Yellow Red Blue
2
1. Descriptions

3
FUSE 5A
GND A B +V
485
+12V
PT Indicator
LOOP Indicator
PHOTO Indicator
L1 COM
MOTOR
L2
AC220V INPUT
AC-L AC-N
NCCOMNO
LIGHT GND A B +V
ENCODER
COMCLSOPN
INPUT1
STP
INPUT2
GND PHO PT
LOOP NO2 CM2 NC2 NO1 CM1 NC1
OUTPUT1OUTPUT2
Remote controller
learning
GND
ANT
Photo cell
Digital Display Tube
Opened
statu
output
Closed
statu
output
Dip switch
PE
live wire
Neutral wire
Blue
Green
Yellow
2. Electrical connections
Air wave switch
Loop Detector
Stop switch
Close switch
Open switch
M means motor,
E means encoder

4
3. Main Features
3.1 Digital positioning, high precision, easy setting.
3.2 Intelligent self-checking and self-protection.
3.3 Delay automatic closing function.
3.4 Safety protection function is available by the
external sensors.
3.5 Remote control.
3.6 Counter mode.
a) Learning transmitter code
Press “LEARN” button which on the main board for one
time, the LED will light, then press the button you desire on the
transmitter for one time, the LED will flash. Repeat these steps for more
transmitters.
Note: 1、The original transmitters has been matched the code, and users
do not need to do this.
2、New transmitters need to be set the steps as above.
b)
If the transmitters are lost or illegally copied, please make
the operation of erasing code to clear all codes that stored in
the control box, after the operation, no transmitter can control
the barrier.
Press and hold the”LEARN” button to light the LED till go out.
Now, all stored codes of transmitters are erased.
Erasing transmitter code
4. Remote controller operation

5
Note: After the quick
setup as above, the
barrier can run
normally, please
operate to open and
close the barrier each
time, inspect if the
limits setting is
satisfied; if the
position is off slightly,
you can go to the
next step limits fine-
tune setting.
Press and hold button more than 3
seconds, then press the button which on
transmitter till “P--1” displays.
Yes
Is the barrier opening Power off
Swap the motor
wire L1 and L2
End
Power on
R*
No
Press and hold button till barrier is vertical
Y**
Press button one time and “P--2” will display
R*
Press button twice and watch the barrier
Y**
Press button one time
B***
Press button five times
R*
B***
Press and hold button till barrier is horizontal
5. Limits setting
Note: For the controller initially installed, manually adjust barrier to middle
position before power on.
Y**
R*= Red button;
= Yellow button;
B***= Blue button;

6
6. Limit fine-tune Settings
Y**
B***
Note: if you expect the boom to stop behind the original set position, please
press button;
if you expect the boom to stop before the original set position, please
press button.
Press and hold button more than 3
seconds, then press the button which on
transmitter till “P--1” displays.
Yes
Need to fine turn limit of open ?
Power on
R*
No
Press button twice and “P--3” displays
R*
Yes
End
Press or button
to adjust the parameter
Press button three times
B***
Need to fine turn limit of close ?
Press button one time
and “P--4” displays
R*
End
Press or button
to adjust the parameter
Y**
Press button four times
R*
B***
Y**
R*
No
Y**
R*= Red button;
= Yellow button;
B***= Blue button;

Function description: The boom will automatically close after
when the barrier open fully.
a set time
Note1: The factory default value is “0”, means that the function is cancelled.
Note2: The maximum delay value is 99 seconds.
7
7. Delay automatically close setting
Press and hold button more than 3
seconds, then press the button which on
transmitter till “P--1” displays.
Power on
R*
Press button four times and “P--5” displays
R*
End
Press or button
to adjust the parameter
Y**
Press button twice
R*
B***
Y**
R*= Red button;
= Yellow button;
B***= Blue button;
Note: Press and hold or button,
the parameter will increase or decrease .
Y** B***

8
8. Counter mode setting
Function description: When there are multiple open signals, the boom
will not close until the same amount of vehicles as the signal’s pass
the loop.
Press and hold button more than 3
seconds, then press the button which on
transmitter till “P--1” displays.
Power on
R*
Press button five times and “P--6” displays
R*
B***
Y**
R*= Red button;
= Yellow button;
B***= Blue button;
Need to use counter mode ?
Yes
Press button one time
“ON” displays ?
No
Yes
End
Press button one time
R*
Y**
Press button
one time
Y**
No Press button
one time
“OFF” displays ? No
Yes

9
9. Dip switch setting
Lamp mode
setting
Please set as
left figure if an alarm lamp
is connect.
Please set as
right figure if a red/green
lamp is connect.
Selection of
protection
signal type
(Normally
open or
Normally
close)
Please set as left
figure if the output
signal from protector
is normally open. The
protector is photocell,
air wave, loop, etc.
Please set as left
figure if the output
signal from protector
is normally close. The
protector is photocell,
air wave, loop, etc.
Selection of
display
mode
Please set as left
figure if you want it to
display the running
status of the barrier.
Please set as left
figure if you want it to
continuously display
the encoder value.

10
10. Error Codes Table
Code
Meaning
Solution
Err1
Encoder signal is invalid
Check the signal wires and connectors
Err2
Barrier operation timeout
Check the mechanical system
Err3
Motor Locked Rotor
1. Check the mechanical system
2. Check motor wires connectors
Err7
Photocell is triggered
Remove the object that block the
photocell
Err8
Air wave is triggered
Remove the object that block the
air wave
ErrA
Parameter of limit is
invalid
Set parameter “P--1” & “P--2” again,
refer to page 6.

#24,Shambavi Building, 23rd Main,Marenahalli,
JP Nagar 2nd Phase, Bangalore - 560078
www.esslsecurity.com
This manual suits for next models
1
Table of contents
Popular Control System manuals by other brands

Endress+Hauser
Endress+Hauser Smart System for Surface Water SSP100B operating instructions

Siemens
Siemens SINUMERIK 808D Programming and operating manual

ADVANTAGE AIR
ADVANTAGE AIR MyAir5 Series user guide

Endress+Hauser
Endress+Hauser Cerabar PMC21 operating instructions

Dormakaba
Dormakaba BEST Wi-Q ONGUARD Interface User Guide

Daktronics
Daktronics RC-100 Operation manual