ETAS FETK-S1.1 User manual

www.etas.com
FETK-S1.1
Emulator Probe for Infineon AURIX MCU
Family
User’s Guide

Copyright
The data in this document may not be altered or amended without special noti-
fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in
relation to this document. The software described in it can only be used if the
customer is in possession of a general license agreement or single license.
Using and copying is only allowed in concurrence with the specifications
stipulated in the contract.
Under no circumstances may any part of this document be copied, reproduced,
transmitted, stored in a retrieval system or translated into another language
without the express written permission of ETAS GmbH.
© Copyright 2020 ETAS GmbH, Stuttgart
The names and designations used in this document are trademarks or brands
belonging to the respective owners.
FETK-S1.1 - User’s Guide R06 EN - 05.2020

ETAS Contents
Contents
FETK-S1.1 - User’s Guide 3
1 About this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 Classification of Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Presentation of Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4 Presentation of Supporting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Basic Safety Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 General Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.2 Requirements for Users and Duties for Operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4 Identifications on the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 Taking the Product Back and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.6 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7 RoHS Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7.1 European Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7.2 China. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.8 Declarable Substances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.9 Use of Open Source Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.1 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.1 Architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2 ECU Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3 FETK Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.4 DAP Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.6 ECU Voltage Supervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.7 Data Emulation and Data Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.8 Trace Based Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.9 Trigger Modes: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.10 Pinless Triggering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.10.1 Startup Handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.10.2 FETK Trigger Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.11 Timer Triggering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.11.1 Trace Triggering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.12 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.13 Pull CalWakeUp until Startup Handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Contents

ETAS Contents
FETK-S1.1 - User’s Guide 4
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.1 Connection to the ECU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.2 Thermal Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3 Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.3.1 FETK Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.3.2 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6 ETK / XETK / FETK Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.2 Configuration Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.1 System Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.1.1 ETAS Compatible Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.1.2 PC with one Ethernet interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.1.3 Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.2 Data Emulation and Measurement Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7.2.1 Data Emulation Memory and Microcontroller Support . . . . . . . . . . . . . . . 38
7.2.2 Measurement Data Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7.3 FETK Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7.4 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.6 Microcontroller Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.7 Test Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.8 DAP Timing Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.8.1 2-Pin DAP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.8.2 3-Pin DAP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.9 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.9.1 ECU Interface Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.10 Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.10.1 ECU Interface Connector CON1 (JTAG Mode) . . . . . . . . . . . . . . . . . . . . . 44
7.10.2 Power Supply Connector CON2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.11 Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.11.1 Top View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.11.2 Side View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8 Cables and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.1 Overview and Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.2 Requirements for failsafe Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.3 CBAM300 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.3.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.3.2 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.3.3 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.3.4 Tightness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.3.5 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
8.4 CBAM320 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.4.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.4.2 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

ETAS Contents
FETK-S1.1 - User’s Guide 5
8.4.3 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.4.4 Tightness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.4.5 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.5 CBAM340 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.5.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.5.2 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.5.3 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.5.4 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.6 CBAM350 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.6.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.6.2 Panel Cut-Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.6.3 Assembling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.6.4 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8.6.5 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
8.7 CBAM305 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
8.7.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
8.7.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
8.7.3 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8.7.4 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.7.5 Tightness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.7.6 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8.8 CBE260 Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.8.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.8.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.8.3 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.8.4 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.8.5 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.9 ETAM8 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8.9.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8.9.2 Pin Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
8.9.3 ECU Connector: Signal Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
8.9.4 Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
8.9.5 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
8.10 ETV5 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.10.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.10.2 Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.10.3 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.10.4 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.11 ETAM2 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8.11.1 Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8.11.2 ECU Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8.11.3 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8.12 ETAM5 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
8.12.1 Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
8.12.2 Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
8.13 ETAM9 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8.13.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8.13.2 ECU Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8.13.3 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8.13.4 Order Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8.14 ETAM10 Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
8.14.1 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

ETAS Contents
FETK-S1.1 - User’s Guide 6
8.14.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
8.14.3 ECU Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
8.14.4 Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
8.14.5 Order Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
9 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
9.1 FETK-S1.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
9.2 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
9.2.1 ECU Adapter Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
9.2.2 ECU Adapter and Power Supply Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
9.2.3 GBit Ethernet and Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.2.4 ECU Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.2.5 Power Supply Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.3 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
10 Contact Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

ETAS About this Document
FETK-S1.1 - User’s Guide 7
1 About this Document
1.1 Classification of Safety Messages
The safety messages used here warn of dangers that can lead to personal
injury or damage to property:
1.2 Presentation of Instructions
The target to be achieved is defined in the heading. The necessary steps for this
are in a step-by-step guide:
Target definition
1. Step 1
2. Step 2
3. Step 3
>Result
DANGER
indicates a hazardous situation with a high risk of death or serious injury if
not avoided
WARNING
indicates a hazardous situation of medium risk which could result in death or
serious injury if not avoided.
CAUTION
indicates a hazardous situation of low risk which may result in minor or
moder-ate injury if not avoided.
NOTICE
indicates a situation which may result in damage to property if not avoided.

ETAS About this Document
FETK-S1.1 - User’s Guide 8
1.3 Typographical Conventions
Software
Hardware
1.4 Presentation of Supporting Information
OCI_CANTxMessage msg0 = Code snippets are presented on a gray back-
ground and in the Courier font.
Meaning and usage of each command are
ex-plained by means of comments. The
comments are enclosed by the usual syntax
for comments.
Choose File Open. Menu commands are shown in boldface.
Click OK. Buttons are shown in boldface.
Press <ENTER>. Keyboard commands are shown in angled
brackets.
The "Open File" dialog box is
displayed.
Names of program windows, dialog boxes,
fields, etc. are shown in quotation marks.
Select the file setup.exe. Text in drop-down lists on the screen, pro-
gram code, as well as path- and file names
are shown in the Courier font.
A distribution is always a one-
dimensional table of sample
points.
General emphasis and new terms are set in
italics.
Bold Menu commands, buttons, labels of the product
Italic Emphasis on content and newly introduced terms
NOTE
Contains additional supporting information.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 9
2 Basic Safety Notices
This chapter contains information about the following topics:
• “General Safety Information” on page 9
• “Requirements for Users and Duties for Operators” on page 9
• “Intended Use” on page 9
• “Identifications on the Product” on page 13
• “Taking the Product Back and Recycling” on page 14
•“CEmarking”onpage14
• “RoHS Conformity” on page 14
• “Declarable Substances” on page 15
• “Use of Open Source Software” on page 15
2.1 General Safety Information
Please observe the Product Safety Notices ("ETAS Safety Notice") and the fol-
lowing safety notices to avoid health issues or damage to the device.
ETAS GmbH does not assume any liability for damages resulting from
improper handling, unintended use or non-observance of the safety precau-
tions.
2.2 Requirements for Users and Duties for Operators
The product may be assembled, operated and maintained only if you have the
necessary qualification and experience for this product. Improper use or use by
a user without sufficient qualification can lead to damages or injuries to one's
health or damages to property.
The safety of systems using the product is the responsibility of the system inte-
grator.
General Safety at Work
The existing regulations for safety at work and accident prevention must be
followed. All applicable regulations and statutes regarding operation must be
strictly followed when using this product.
2.3 Intended Use
An ETK is an electronic component that is installed in a vehicle control unit
(ECU) to read data from the ECU or write data to the ECU.
NOTE
Carefully read the documentation (Product Safety Advice and this User's
Guide) that belongs to the product prior to the startup.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 10
Application Area of the Product
This product was developed and approved for automotive applications. For use
in other application areas, please contact your ETAS contact partner.
Requirements for Operation
The following requirements are necessary for safe operation of the product:
• Use the product only according to the specifications in the correspond-
ing User's Guide. With any deviating operation, the product safety is no
longer ensured.
• Observe the regulations applicable at the operating location concerning
electrical safety as well as the laws and regulations concerning work
safety!
• Do not apply any voltages to the connections of the product that do not
correspond to the specifications of the respective connection.
• Connect only current circuits with safety extra-low voltage in accordance
with EN 61140 (degree of protection III) to the connections of the prod-
uct.
• The power supply for the product must be safely disconnected from the
supply voltage. For example, use a car battery or a suitable lab power
supply.
• Use only lab power supplies with double protection to the supply system.
• Ensure that the connections of the power supply are easily accessible.
• The module does not have an operating voltage switch.
– Switch on the product by connecting the power supply cable with the
power supply or by switching on the power supply.
– Switch off the product by disconnecting it from the power supply or
by switching off the power supply.
DANGER
Connect the power cord only with a vehicle battery or with a lab power sup-
ply! A connection to power outlets is prohibited.
Route the power cord in such a way that it is protected against abrasion,
damages, deformation and kinking. Do not place any objects on the power
cord.
Never apply force to insert a plug into a socket. Ensure that there is no con-
tamination in and on the connection, that the plug fits the socket, and that you
correctly aligned the plugs with the connection.
Do not use the product in a wet or damp environment.
Do not use the product in potentially explosive atmospheres.
Keep the surfaces of the product clean and dry.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 11
Potential Equalization
Requirements for the technical State of the Product
The product is designed in accordance with state-of-the-art technology and
recognized safety rules. The product may be operated only in a technically flaw-
less condition and according to the intended purpose and with regard to safety
and dangers as stated in the respective product documentation. If the product
is not used according to its intended purpose, the protection of the product
may be impaired.
Maintenance and Cleaning
The product is maintenance-free. Use a lightly moistened, soft, lint-free cloth
for cleaning the product. Ensure that no moisture can enter. Never spray clean-
ing agents directly onto the product. Do not user any sprays, solvents or abra-
sive cleaners which could damage the product.
Transport and Installation
CAUTION
Danger from inadvertent current flow!
Depending on the design, the shield of the Ethernet cables can be connected
with the housing of the module. Install the products only on components with
the same electrical potential or isolate the products from the components.
CAUTION
The ETK can be damaged or destroyed!
Some components of the ETK board may be damaged or destroyed by elec-
trostatic discharges. Please keep the ETK in its storage package until it is
installed.
The board should only be taken from its package, configured, and installed at
a work place that is protected against static discharge.
CAUTION
During installation and removal, ECU and ETK must be in a de-eenergized
state!
CAUTION
Risk of short circuiting the internal signals of the ETK!
When you mount the ETK to the ECU, you must ensure that the screws and
washers used will not penetrate the ETK printed circuit board.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 12
Cabling
Use exclusively ETAS cables at the connections of the product! Adhere to the
maximum permissible cable lengths! Observe the assignment of the cables to
the connectors! Detailed information about cabling is located in the ETK User's
Guides.
CAUTION
Differences in case ground potentials can cause high currents to flow
through the shields of the cables that connect various system modules.
Ensure that the module mounting surfaces are at the same electrical poten-
tial or insulate the modules from their mounting surfaces.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 13
2.4 Identifications on the Product
Fig. 2-1 Adhesive Label (Example: Label for XETK-S14.0)
The following symbols are used for identifications of the product:
Symbol Description
The User's Guide must be read prior to the startup of the
product!
Symbol for WEEE, see chapter 2.5 on page 14
Symbol for CE conformity, see chapter 2.6 on page 14
Symbol for China RoHS, see chapter 2.7.2 on page 14
Symbol for China RoHS, see chapter 2.7.2 on page 14
Symbol for electrostatic sensitive components
XETK-S14.0A Product designation (example)
F 00K 110 722 Order number of the product (example)
SN: yyxxxxx Serial number (7-digit)
XXXX/YY Product version
ZZZZ Year of manufacture
ETAS GmbH,
PO Box 300220,
70442 Stuttgart,
Germany
Manufacturer's address
NOTE
For symbols and product information one or several adhesive labels can be
used.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 14
2.5 Taking the Product Back and Recycling
The European Union has passed a directive called Waste Electrical and Elec-
tronic Equipment, or WEEE for short, to ensure that systems are setup through-
out the EU for the collection, treating and recycling of electronic waste.
This ensures that the devices are recycled in a resource-saving way represent-
ing no danger to health or the environment.
Fig. 2-2 WEEE-Symbol
The WEEE symbol (see Fig. 2-2 on page 14) on the product or its packaging
shows that the product must not be disposed of as residual garbage.
The user is obliged to collect the old devices separately and return them to the
WEEE take-back system for recycling. The WEEE directive concerns all ETAS
devices but not external cables or batteries.
For more information on the ETAS GmbH Recycling software, contact the ETAS
sales and service locations.
2.6 CE marking
With the CE mark attached to the product or its packaging, ETAS confirms that
the product corresponds to the applicable product-specific European Direc-
tives. The CE Declaration of Conformity for the product is available upon
request.
2.7 RoHS Conformity
2.7.1 European Union
The EU Directive 2011/65/EU limits the use of certain dangerous materials for
electrical and electronic devices (RoHS conformity).
This product does not contain any of the restricted substances specified in the
EU Directive 2011/65/EU or exceeds the maximum concentrations stipulated
therein. For individual electronic components used in our products, there are
currently no equivalent alternative substances, which is why we make use of
the exception 7C-I in Annex III of this Directive.
ETAS confirms that the product corresponds to this directive which is applica-
ble in the European Union.
2.7.2 China
ETAS confirms that the product meets the product-specific applicable guide-
lines of the China RoHS (Management Methods for Controlling Pollution
Caused by Electronic Information Products Regulation) applicable in China
with the China RoHS marking affixed to the product or its packaging.

ETAS Basic Safety Notices
FETK-S1.1 - User’s Guide 15
2.8 Declarable Substances
European Union
Some products from ETAS GmbH (e.g. modules, boards, cables) use compo-
nents with substances that are subject to declaration in accordance with the
REACH regulation (EU) no.1907/2006.
Detailed information is located in the ETAS download center in the customer
information "REACH Declaration" (www.etas.com/Reach). This information is
continuously being updated.
2.9 Use of Open Source Software
The product uses Open Source Software (OSS). This software is installed in the
product at the time of delivery and does not have to be installed or updated by
the user. Reference shall be made to the use of the software in order to fulfill
OSS licensing terms. Additional information is available in the document "OSS
Attributions List" at the ETAS website www.etas.com.

ETAS Introduction
FETK-S1.1 - User’s Guide 16
3 Introduction
This section contains information about the basic features and applications of
the FETK-S1.1 Interface Board (FETK = Emulator Test Probe for the ETAS
ES89x ECU and Bus Interface Modules), hints to system requirements for oper-
ating the FETK-S1.1, and other details.
3.1 Applications
The FETK-S1.1 is an emulator probe for the Infineon AURIX microcontroller
family. It is a serial FETK designed for use with the DAP interface (IEEE/ISTO
5001).
Fig. 3-1 FETK-S1.1
To access the ECU the FETK-S1.1 has to be connected via ES89x modules.
The system can be used for high speed Measurement, Calibration and ECU
flash programming. Support of Rapid Prototyping applications e.g. functional
prototyping - bypass depends on the functionality of the connected modules.
The FETK-S1.1 and ES89x system uses the standardized protocol “XCP on
Ethernet” for PC communication. Thus 3rd party tools can be connected to the
ECU as well.
NOTE
For supported Infineon AURIX microcontrollers, refer to chapter 7.1.3
on page 36.
FETK-S1.1
ECU interface connector 20 pin FCI
Power supply connector 6 pin MOLEX
Power supply for ED devices (VDDS-
BRAM)
min. 1.3 V
SBRAM sense Yes
Pinless triggering Yes
Timer triggering Yes

ETAS Introduction
FETK-S1.1 - User’s Guide 17
3.2 Features
General
• Gigabit Ethernet Interface:
– Connection to PC via ES89x modules
– Proprietary Ethernet protocol for FETKs
– Supports a variety of standard applications
• Calibration tool access performed via the microcontroller DAP interface
– 3.3 V DAP output levels, 5.0 V tolerant DAP input
– Configurable DAP interface modes:
2-pin DAP mode, clock speed 50 MHz and100 MHz)
3-pin DAP mode (wide mode), clock speed 100 MHz and 160 MHz
• Permanent storage of configuration in EEPROM
• Third party MC-tool support via ES89x module possible
Measurement
• Fast measurements (DISTAB) – ECU raster at under 50 µs
• Measurement via Trace2Ram for low ECU runtime impact and fast ras-
ters down to 10 µs
• Supports “turnkey mechanism” - measurement start immediately after
“Ignition on” and proceed measurement during ECU reset
• Pin-less ECU handshake and trigger mechanism
• Hook-based (DISTAB) and hook-less measurement approaches
Calibration
• Concurrent use of calibration and measurement performed via micro-
controller debug interface
• Working Page & Reference Page (2 page concept) realized by microcon-
troller overlay mechanism
• Direct access to parameters, curves, and maps in internal RAM
• Microcontroller capability of internal Flash emulation can be used
• FETK powers Emulation Device RAM (for calibration purpose)
• Supports “Start on Any Page”
• Supports special coldstart mechanism (“Calibration Wake Up”):
– Calibration Wake Up: Wake up mechanism to wake up the power sup-
ply of the ECU via the Calibration Wake up pin
– Pull CalWakeUp until Startup Handshake: duration of the Wake up
mechanism is configurable
ECU Flash Programming via FETK
• Using microcontroller debug interface, ECU software support not neces-
sary
• Braindead flashing under ProF control

ETAS Introduction
FETK-S1.1 - User’s Guide 18
Further characteristics
• “ETK Drivers and Tools” update to support ETAS software tools (INCA,
XCT)
• Firmware update (programming of the logic device) through HSP soft-
ware service packs; removal of FETK or ECU is not necessary
• Mounting possibilities inside or on top of ECU
• Temperature range suitable for automotive application
For more technical data on the FETK-S1.1 consult the chapter “Technical Data”
on page 36.

ETAS Hardware Description
FETK-S1.1 - User’s Guide 19
4 Hardware Description
In this chapter, the function blocks of the FETK-S1.1 are explained in detail.
4.1 Architecture
Fig. 4-1 shows the block diagram of the FETK-S1.1.
Fig. 4-1 FETK-S1.1 Architecture
While the microcontroller accesses the program data (not the program code)
out of the data emulation memory provided by the microcontroller, the content
of the data emulation memory can simultaneously be modified by the calibra-
tion and development system through the FETK-S1.1 Ethernet interface. This
process enables adjustments of parameters, characteristic lines and maps
through the calibration and development system. Using an additional measure-
ment data memory area, the ECU microcontroller can provide data to the cali-
bration and development system by buffering the data (DISTAB17) and
triggering the FETK-S1.1 to read the data via DAP. The FETK-S1.1 -
User’s Guide then reads, buffers, processes and sends this measured data to
the PC.
If no additional measurement data memory is available, the FETK-S1.1 can
alternatively read the data to be measured directly from the microcontroller’s
memory. This process is Triggered Direct Measurement (TDM) with DISTAB17.
The 100/1000 Mbit/s Ethernet interface provides communication with the
ES89x module.
FETK Connector Description
CON1 ECU Interface
CON2 Power supply
CON3 Ethernet interface (ETAS module or PC)
Tool
Int er f ace
Trigger
Unit
Co n t r o l
Unit
Interf ace
to ECU
Automatic
Po w e r- O n
FET K
Int er f a ce
1
Gbit/ s
Po w e r
Su p p l y
Monit oring
Pow e r
Supply
3.0 ... 36 V
St andby
Pow e r
Su p p l y
3.0 ... 36 V
ECU
Re se t &
Pow e r
Control
ECU Rese t
Et her net
Ph y
Et hernet
Tr af f i c
Detection
Sense ECU Voltage
ECU
Debug
Int er f ace
Configu-
rat ion
Fl a sh
UBatt
ECU ED-RAM, Interface Supply
CA L
Wakeup
Debug
Po w e r

ETAS Hardware Description
FETK-S1.1 - User’s Guide 20
4.2 ECU Interface
The FETK-S1.1 is connected via connectors CON1 and CON2 to the ECU with
two adapter cables (refer to Fig. 4-2 on page 20). The pin definition depends on
the application and the microcontroller type. In general the ECU interface con-
sists of
• 1 ECU voltage line, which is not used for FETK power supply, but only for
detection of the ECU status, therefore the power consumption on this
line is negligible (refer to chapter 4.5 on page 23)
• 1 Reset line which allows the FETK to control and monitor the system
reset of the ECU
• 1 Reset line which allows the FETK to monitor the system reset of the
ECU
• 5 Debug line interfaces for the communication between the FETK-S1.1
and the microcontroller
•1Watchdogdisableline
• 1 ground line
Fig. 4-2 Location of the ECU Interfaces
Fig. 4-3 ETAM8 Adapter mounted at CON1
CON2
CON1
CON1
ETAM8
Adapter
1
This manual suits for next models
1
Table of contents
Other ETAS Recording Equipment manuals