Safety markings:
Read this first:
>This fitting must be installed in accordance with the Building Regulations. These may be
obtained from HMSO or viewed and downloaded from www.odpm.gov.uk following the link for
Building Regulations.
>If in any doubt, consult a qualified electrician.
>Switch off the mains before commencing installation and remove the appropriate circuit fuse.
>Do not connect to a circuit which also has inductive loads connected as spikes generated
switching inductive loads may damage electronic components within your PIR.
>Suitable for indoor use only.
>This product is only suitable for use in living areas ( not for areas constantly subject to moisture ).
>Before making fixing hole (s), check that there are no obstructions hidden beneath the mounting
surface such as pipes or cables.
>Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g.
metallic surfaces).
>If the location of your new fitting requires the provision of a new electrical supply, the supply must
conform with the requirements of the Building Regulations.
>This product is designed for permanent connection to fixed wiring: this should be either a suitable
lighting circuit ( protected with a 5 or 6 Amp MCB or fuse ) or a fused spur ( with a 3 Amp fuse ) via
a fused connection unit.
>Make connections to the electrical supply in accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
>This fitting is double insulated, do not connect any part to earth.
>You are advised at every stage of your installation to double-check any electrical connections you
have made. After you have completed your installation there are electrical tests that should be
carried out: these tests are specified in the Wiring Regulations ( BS7671 ) referred to in the
Building Regulations. If in doubt, consult a qualified electrician.
Installation:
1) Remove PIR and fixings from the packaging.
2) Remove the small screw located in the lens cover taking care not to loose it and put to one side.
3) Using the PIR base as a template mark the fixing positions on the mounting surface.
4) Pass incoming and load cable through the cable entry suitable for your installation.
5) Connect the incoming LIVE to the terminal marked L Connect the incoming NEUTRAL to the
terminal marked N.
6) Connect the load LIVE to the terminal Marked L Connect the load NEUTRAL to the terminal
marked N.
7) Fit PIR to prepared mounting surface with screws and wall plugs provided.
8) Sucure cables to cable clamp when entering from the outer rim of the PIR.
9) Please check that the wall plugs and screws provided are suitable for your application, if not
please discard and use your own fixings.
10) Refit the lens cover and secure with the small screw.
Walk Testing:
1) Before commencing the walk test The LUX dial should be set to the day position (toward the
symbol) and the time control to the minimum position (toward the — symbol).
2) Walk slowly during the walk testing in order to gain the desired detection area,
3) When the walk test is complete set the LUX level & TIME on adjustment controls to the required
operating settings.
4) Once the PIR detector has been installed the Manual override may be activated by switching the
mains OFF/ON twice within 3 Seconds. (The lighting load will flash 3 times to indicate override
mode).
5) The manual override will keep the lighting load on for approximately 8 hours. If there is no further
override operations , the PIR detector will return to auto mode automatically after approximately 8
hours has elapsed. (The lighting load will flash 3 times to indicate the return to auto mode).
Mode Changing:
Turn off the Override switch for over 3 seconds and then turn on again, the PIR will begin a new process
for mode changing.
ADJUSTING the LUX CONTROL:
The LUX control has a built in photocell which detects daylight and darkness. Rotate the LUX control to set
to the desired level of daylight. Allow approximately 5 seconds for the photocell to stabilise at the desired
level.
ADJUSTING the TIME CONTROL:
The length of time that the switch remains on can be adjusted from approximately (10±5) seconds to
approximately 6±1) Minutes. This is adjusted by rotating the time gauge. Once the load has been triggered
by the PIR detector, any subsiquent movement will start the timed period from the beginning.