If you experience problems:
If your PIR360WH is defective or develops a fault, please return it to the place where you bought it. You
can call our Helpline for advice. The Helpline will gladly give advice on any aspect of any Eterna Lighting
product but may not be able to give specific instructions regarding individual installations.
If in doubt, consult a qualified electrician.
Help line:
Tel: 01933 673 144 Fax: 01933 678 083 Email: sales@eterna-lighting.co.uk
For answers to frequently asked questions ( FAQs ) and other information visit our web-site
www.eterna-lighting.co.uk
Technical Information:
Switching Load: Maximum 5A 1000W Resistive or 300W Fluorescent
Supply Voltage: 230V 50 Hz
Time Control: From approx 5 seconds to approx 6 minutes
LUX Control: Daylight & Night adjustable.
Detection range: 360º Up to 5 metre radius mounted at 3 metres.
Mounting Height: 3 metre maximum.
Protection: Class !
Cleaning:
>Clean this fitting only with a soft dry cloth
>Do not use any chemical or abrasive cleaners.
Eventually, you may want to replace this fitting:
When your fitting comes to the end of it’s life or you choose to update or upgrade it by
replacing it, please do not dispose of it with your normal household waste, please recycle
where facilities exist. When you need to dispose of this fitting, check with your retailer or
local authority for suitable options. New regulations will encourage the recycling of Waste
from Electrical and Electronic Equipment ( European “WEEE Directive” effective August
2005 ).
PLEASE READ THESE INSTRUCTIONS BEFORE
INSTALLING YOUR NEW FITTING
- -
PLEASE RETAIN FOR FUTURE REFERENCE
360º Indoor PIR Occupancy
Dector
Model(s)
PIR360WH
Pack contents:
PIR360WH 1
Screws 2
Wall Plugs 2
Safety markings:
Read this first:
>This fitting must be installed in accordance with the Building Regulations. These may be
obtained from HMSO or viewed and downloaded from www.odpm.gov.uk following the link for
Building Regulations.
>If in any doubt, consult a qualified electrician.
>Switch off the mains before commencing installation and remove the appropriate circuit fuse.
>Do not connect to a circuit which also has inductive loads connected as spikes generated
switching inductive loads may damage electronic components within your PIR.
>Suitable for indoor use only.
>This product is only suitable for use in living areas ( not for areas constantly subject to moisture ).
>Before making fixing hole (s), check that there are no obstructions hidden beneath the mounting
surface such as pipes or cables.
>Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g.
metallic surfaces).
>If the location of your new fitting requires the provision of a new electrical supply, the supply must
conform with the requirements of the Building Regulations.
>This product is designed for permanent connection to fixed wiring: this should be either a suitable
lighting circuit ( protected with a 5 or 6 Amp MCB or fuse ) or a fused spur ( with a 3 Amp fuse ) via
a fused connection unit.
>Make connections to the electrical supply in accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
>This fitting is double insulated, do not connect any part to earth.
>You are advised at every stage of your installation to double-check any electrical connections you
have made. After you have completed your installation there are electrical tests that should be
carried out: these tests are specified in the Wiring Regulations ( BS7671 ) referred to in the
Building Regulations. If in doubt, consult a qualified electrician.
Installation:
1) Remove PIR and fixings from the packaging.
2) Remove the small screw located in the lens cover taking care not to loose it and put to one side.
3) Using the PIR base as a template mark the fixing positions on the mounting surface.
4) Pass incoming and load cable through the cable entry suitable for your installation.
5) Connect the incoming LIVE to the terminal marked L Connect the incoming NEUTRAL to the
terminal marked N.
6) Connect the load LIVE to the terminal Marked L Connect the load NEUTRAL to the terminal
marked N.
7) Fit PIR to prepared mounting surface with screws and wall plugs provided.
8) Sucure cables to cable clamp when entering from the outer rim of the PIR.
9) Please check that the wall plugs and screws provided are suitable for your application, if not
please discard and use your own fixings.
10) Refit the lens cover and secure with the small screw.
Walk Testing:
1) Before commencing the walk test The LUX dial should be set to the day position (toward the
symbol) and the time control to the minimum position (toward the — symbol).
2) Walk slowly during the walk testing in order to gain the desired detection area,
3) When the walk test is complete set the LUX level & TIME on adjustment controls to the required
operating settings.
4) Once the PIR detector has been installed the Manual override may be activated by switching the
mains OFF/ON twice within 3 Seconds. (The lighting load will flash 3 times to indicate override
mode).
5) The manual override will keep the lighting load on for approximately 8 hours. If there is no further
override operations , the PIR detector will return to auto mode automatically after approximately 8
hours has elapsed. (The lighting load will flash 3 times to indicate the return to auto mode).
Mode Changing:
Turn off the Override switch for over 3 seconds and then turn on again, the PIR will begin a new process
for mode changing.
ADJUSTING the LUX CONTROL:
The LUX control has a built in photocell which detects daylight and darkness. Rotate the LUX control to set
to the desired level of daylight. Allow approximately 5 seconds for the photocell to stabilise at the desired
level.
ADJUSTING the TIME CONTROL:
The length of time that the switch remains on can be adjusted from approximately (10±5) seconds to
approximately 6±1) Minutes. This is adjusted by rotating the time gauge. Once the load has been triggered
by the PIR detector, any subsiquent movement will start the timed period from the beginning.
PIR360WH 360 Indoor PIR Occupancy Detector 050801NB

Other Eterna Security Sensor manuals

Eterna PIR110WH Setup guide

Eterna

Eterna PIR110WH Setup guide

Eterna EX360PIRWH User manual

Eterna

Eterna EX360PIRWH User manual

Eterna MHDB User manual

Eterna

Eterna MHDB User manual

Eterna PIR180BK Setup guide

Eterna

Eterna PIR180BK Setup guide

Eterna PIR110BK User manual

Eterna

Eterna PIR110BK User manual

Eterna SDION User manual

Eterna

Eterna SDION User manual

Popular Security Sensor manuals by other brands

Det-Tronics X5200 instructions

Det-Tronics

Det-Tronics X5200 instructions

Notifier B614LP installation instructions

Notifier

Notifier B614LP installation instructions

Busch-Wachter 6847 220 MasterLINE operating instructions

Busch-Wachter

Busch-Wachter 6847 220 MasterLINE operating instructions

SOVAL DN50 Operation, maintenance & instruction manual

SOVAL

SOVAL DN50 Operation, maintenance & instruction manual

STEINEL IS 130-2 quick start guide

STEINEL

STEINEL IS 130-2 quick start guide

FRIEDLAND Magnetic Contact Installation and operating instructions

FRIEDLAND

FRIEDLAND Magnetic Contact Installation and operating instructions

Moma smart SL9S instruction manual

Moma

Moma smart SL9S instruction manual

urmet domus Bitron Home 902010/24 Quick start manual

urmet domus

urmet domus Bitron Home 902010/24 Quick start manual

C-LOGIC 650-MD instruction manual

C-LOGIC

C-LOGIC 650-MD instruction manual

Eaton CEAG GuideLed Cinema 11011 CG-S Mounting and operating instructions

Eaton

Eaton CEAG GuideLed Cinema 11011 CG-S Mounting and operating instructions

RKI Instruments 35-3001-05 Series Operator's manual

RKI Instruments

RKI Instruments 35-3001-05 Series Operator's manual

ESYLUX PD-C360i/12 mini KNX manual

ESYLUX

ESYLUX PD-C360i/12 mini KNX manual

DSC BRAVO5 installation instructions

DSC

DSC BRAVO5 installation instructions

Schlage HandPunch GT-400 Setup guide

Schlage

Schlage HandPunch GT-400 Setup guide

iRay Technology Mars1417V user manual

iRay Technology

iRay Technology Mars1417V user manual

Smartscape DALI user manual

Smartscape

Smartscape DALI user manual

LG 10HQ701G-B owner's manual

LG

LG 10HQ701G-B owner's manual

Texecom Capture P15-W manual

Texecom

Texecom Capture P15-W manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.