IP66 16 Amp Electronic Outdoor Time Delay Switch
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Pack contents:
1 x Fitting
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST  DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
Disconnect the power and clean the exterior only of
this switch with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
16A / 240V
Email: [email protected].uk / [email protected].uk
Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 0117
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This time delay switch must be installed by a
competent person in accordance with the Building
Regulations making reference to the current edition
of the IEE Wiring Regulations (BS7671).
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that it is t for
the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage
or premature failure resulting from inappropriate
use.
This product is designed and constructed according
to the principles of the appropriate British Standards
and is intended for normal service.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse.
Do not overload the switch; check that the total
wattage and start up surge current (if any) of the
connect load does not exceed the maximum
specied.
Disconnect the switch from the electrical supply
before ash or high voltage testing.
Suitable for indoor and outdoor use.
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables. If your switch is part of the
provision of a new electrical supply, the supply
must conform with the requirements of the Building
Regulations making reference to the current edition
of the IEE Wiring Regulations (BS7671).
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
NOTE: This is not a two-wire system and requires
neutral connection.
When making connections, ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This switch is double insulated; do not connect any
part to earth.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out:
these tests are specied in the Wiring Regulations
(BS7671) referred to in the Building Regulations
LOAD SPECIFICATION:
Incandescent lighting loads - 16A maximum.
Fluorescent lighting loads - 6A maximum.
Compact uorescent/low energy lighting loads - 3A
maximum.
Low voltage lighting loads - 3A maximum.
LED load 300W.
NOTE: a maximum of 6 uorescent light ttings is
recommended with total power factor correction
capacitance not exceeding 40f.
Fans and ventilation equipment – 3A maximum.
SON light ttings must be switched via a contactor
or other external relay. If you are using this switch to
control magnetic switch start uorescent ttings and
your light ttings strike inconsistently, a power factor
correction capacitor may be required. If your light
tting ickers or fails to turn o correctly, this is most
likely to be due to incorrect or missing power factor
correction.
Check with the manufacturer of the light tting and/
or supplier of power factor correction capacitors for
the exact specication required for your installation.
A minimum of 1F for each tting may be connected.
INSTALLATION:
01. Choose the location for your new switch
according to the conditions above.
02. Undo the large screws in each corner of the front
of the switch and lift o the lid.
03. Mark the positions of the xing holes at the
corners of a rectangle 62mm wide x 92mm high.
04. Prepare the xing holes and insert wall plugs if
necessary.
05. Whether you are intending to use cable glands
or conduit to make your cable entry, you will
need to make hole(s) in the rear half of the case to
accept your chosen tting.
06. Secure the rear half of the case to the wall using
suitable xings.
07. Make the electrical connections according to the
colour code on previous page.
08. Set the desired “on” time by combination of dip
switches and the rotary control, see Fig 1. and
table below.
09. Close the switch case and tighten the screws.
Take care not to over-tighten.
10. Restore the mains power and wait 20 seconds for
the switch to stabilise.
11. Activate the switch and check the “on” time.
12. If the time “on” requires further adjustment, turn
of the power at the mains before opening the
switch case. Remember to wait 20s after restoring
the power before activating the switch again.
TRIGGER FUNCTION:
The timer can be triggered by applying a live
connection to the “trigger” terminal. This can be
done using a momentary switch for example, in
lighting applications; or an unswitched link for
applications such as extractor fan over-run.
MULTIPOINT SWITCHING:
For switching the load from multiple locations simply
connect two or more units in parallel.
NOTE: All switches must share the same power
supply.
SWITCH SETTING
TIMER FUNCTION
1 2 3 4
0 0 1 0
2 seconds to 50 seconds
1 0 1 0
50 seconds to 20 minutes
1 1 1 0
20 minutes to 70 minutes
1 1 0 0
70 minutes to 2 hours
0 0 0 1
Timer function disabled
On
0

Other Eterna Switch manuals

Eterna TLS68EX Setup guide

Eterna

Eterna TLS68EX Setup guide

Eterna RDT10A User manual

Eterna

Eterna RDT10A User manual

Eterna TLS1440 User manual

Eterna

Eterna TLS1440 User manual

Eterna WS120PIR Setup guide

Eterna

Eterna WS120PIR Setup guide

Popular Switch manuals by other brands

Grandbeing SW0301 operating instructions

Grandbeing

Grandbeing SW0301 operating instructions

Garmin Vivohub 2 installation instructions

Garmin

Garmin Vivohub 2 installation instructions

Comnet CLFE IPS Series Installation and operation manual

Comnet

Comnet CLFE IPS Series Installation and operation manual

Sima svs-3 user manual

Sima

Sima svs-3 user manual

Cabletron Systems VNswitch 900GV Installation and configuration

Cabletron Systems

Cabletron Systems VNswitch 900GV Installation and configuration

NETGEAR GSM7312 - ProSafe Layer 3 Managed Gigabit... datasheet

NETGEAR

NETGEAR GSM7312 - ProSafe Layer 3 Managed Gigabit... datasheet

Manhattan 160612 user manual

Manhattan

Manhattan 160612 user manual

Extron electronics MMX 42 AV RCA Specification sheet

Extron electronics

Extron electronics MMX 42 AV RCA Specification sheet

Cooper Crouse-Hinds CEAG KO operating instructions

Cooper

Cooper Crouse-Hinds CEAG KO operating instructions

H3C S6890 Series OpenFlow Command Reference

H3C

H3C S6890 Series OpenFlow Command Reference

Cisco Meraki MS250 Series installation guide

Cisco

Cisco Meraki MS250 Series installation guide

Matrix Switch Corporation MSC-2HD3208S product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-2HD3208S product manual

D-Link DES-1024D Brochure & specs

D-Link

D-Link DES-1024D Brochure & specs

Cabletron Systems SmartSTACK EPIM1000-S1LX 1000BASE-LX Quick installation guide

Cabletron Systems

Cabletron Systems SmartSTACK EPIM1000-S1LX 1000BASE-LX Quick installation guide

IOGear GUB231 user manual

IOGear

IOGear GUB231 user manual

ATEN CS1922M user manual

ATEN

ATEN CS1922M user manual

Avitech Sequoia 4K60 quick start guide

Avitech

Avitech Sequoia 4K60 quick start guide

Fortinet 5003A Fabric and Base Backplane Communications Guide

Fortinet

Fortinet 5003A Fabric and Base Backplane Communications Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.