Important Safety Instructions
• Read all instructions before using the device. Keep the manual
for future reference.
• Only use the device as described in this user manual. Any
misuse may cause electric shocks, burns, start a fire or other
unexpected hazards.
• Be aware that this device is designed for individuals to
measure their weight and to monitor their body composition.
Any information provided by this device is in no way meant to
treat, cure, or prevent diseases or illnesses from happening.
• DO NOT use this device if you are pregnant or if you suspect
you may be pregnant. The eects of this device on a fetus are
unknown and untested.
• DO NOT use this device if you use a wearable or implanted
electronic device such as a defibrillator or pacemaker.
• This device should not be used by individuals who are acutely
or chronically ill, suering from diseases or taking medications
that can aect water levels. The accuracy of the readings for
these individuals has not been verified. Specific medical advice
should be obtained from a physician.
• The device is equipped with a data transmission function
that emits electromagnetic energy. Portable Radio Frequency
(RF) communications equipment (including peripherals
such as antenna cables and external antennas) should not
be used within 30 cm (12 inches) of the device, otherwise,
performance may be aected.
• Do not modify this device.
• Do not expose this device to extreme temperatures, direct
sunlight, moisture, or corrosive environments.
• To prevent slipping, do not step on the device after bathing or
showering.

02 03
English
English
Usage Tips:
To ensure measurement accuracy, follow the instructions
below when you start your measurement:
• Place the scale on a flat, hard surface. Soft surfaces such as
carpeting will aect the performance of the scale.
• Step on the platform with bare feet. Stand still and keep
full contact with the electrodes until the measurement is
complete.
• For the most consistent measurements, weigh yourself at the
same time of day and location.
• Avoid weighing yourself immediately after strenuous exercise,
sitting in the sauna, taking a bath, or drinking and eating.
• The condition of the skin on the bottom of your feet can aect
the measurement. The natural eects of aging or activity can
make this skin hard. Take the reading with clean, slightly damp
feet for best accuracy.
• Body fat percentage estimates will vary with the amount
of water in the body, and can be aected by dehydration or
overhydration due to factors such as alcohol consumption,
menstruation, illness, intense exercise etc.
Notice
This symbol means the product must not be discarded as household
waste, and should be delivered to an appropriate collection facility
for recycling. Proper disposal and recycling helps protect natural
resources, human health and the environment. For more information
on disposal and recycling of this product, contact your local
municipality, disposal service, or the shop where you bought this
product.
This symbol means ”Refer to instruction manual or booklet”.
• This device should not be used when it is adjacent to or
stacked on top of another device because it could cause the
device to operate improperly. If such use is necessary, this
device and the other device should be observed to verify that
they are operating normally.
• This device is powered by three AAA batteries. Do not attempt
to recharge non-rechargeable batteries as this can cause the
batteries to leak or explode.
• This device can be powered by rechargeable batteries.
• Do not mix and use dierent types of batteries together
e.g. lithium-ion (Li-ion) and nickel-metal hydride (NiMH)
batteries.
• Do not mix new and used batteries.
• If the device will not be used for an extended period of time,
remove batteries before storing the device in a cool and dry
place.
• This device can be used by individuals over 16 years old and
persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children should
not play with the appliance. Cleaning and user maintenance
should not be done by children without supervision.
• Used batteries should be placed in a sealed plastic bag
and disposed of safely according to local environmental
regulations.

04 05
English
English
What’s In the Box
Smart Scale P1 AAA Battery (×3) Owner’s Manual &
Other Documents
Inserting the Batteries
Turn the scale over and place it on a flat surface.
Open the battery door and insert three AAA batteries. Make sure the
positive and negative ends are facing the correct polarity directions
marked in the battery compartment.
- The digits “ ” will show on the LED display.
Close the battery door and wait until the digits “ ” are shown on the
LED display.
will appear on the LED display when the batteries are low.
Replace all three batteries at the same time. Do not mix new and used
batteries.
Declaration of Conformity
This product complies with the radio interference requirements of the European
Community. Hereby, Anker Innovations Limited declares that the radio equipment
type T9147 is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
https://www.eufylife.com/.
Maximum output power: 4 dBm
Frequency band: 2.4G band (2.4000GHz - 2.4835GHz)

06 07
English
English
Selecting the Measuring Unit
Press the UNIT button at the bottom of the scale to cycle through and select
the measuring unit: lb (Pound) / kg (Kilogram). The measuring unit can be
selected from within the EufyLife app as well.
Installing the EufyLife App and Pairing
Download the EufyLife app from the App Store (iOS devices) or Google
Play (Android devices).
Enable Bluetooth on your smartphone or tablet.
Open the EufyLife app and follow the on-screen instructions to pair the
scale with your device.
- Once paired, the app and scale will automatically connect the next time
the app is opened.
Bluetooth ON
Smart Scale
EufyLife
Status Icon Indicates
Flashing Pairing
Solid Connected
- This scale is compatible with devices running iOS 9.0 and above or
Android 4.4 and above.
- Do not pair the scale from your smartphone’s Bluetooth menu. Use
the EufyLife app to pair the scale with your smartphone.
Starting a Measurement
Before taking your first measurement, you will need to create and set up a
user ID in the EufyLife app.
Place the scale on a hard and flat surface.
Open the EufyLife app and select Smart Scale on the device homepage.
Step barefoot onto the scale. An analysis of your body’s composition will
begin automatically.
Step barefoot onto the center of the scale. Stand still and keep full
contact with the electrodes until the measurement is complete.

08 09
English
English
Weight-Only Measurement
This scale can also be used as a conventional weight-reading scale.
To measure your current weight, you can
• step on the scale wearing your shoes; or
• select the weight-only measuring mode in the EufyLife app.
Maintenance
Regularly clean the scale with a dry or slightly dampened soft cloth.
- Do not wash the scale with water or immerse it in water.
- Never use detergents to clean the scale as this may cause it
to malfunction or discolor.
Troubleshooting
Error Message
Error Display Description Solution
Overload. The device will power o. Stop using this scale for measurement.
Low battery. The device will
power o.
Replace all three batteries at the same
time.
Measurement failure.
• Step barefoot and keep full contact
with the electrodes.
• Stand still until the measurement on
the LED display locks.
When Measuring
Issue Cause Solution
Abnormal measurement
results:
• Too high
• Too low
• Huge dierence
between two recent
measurements
• Incorrect posture. Step onto the scale barefoot and
stand still.
• Device is placed on
soft carpeting or
uneven surface.
Place the device on a hard and flat
surface.
LED display does not turn
on after stepping onto the
scale.
• Batteries not installed. • Install three new AAA batteries
• Worn batteries. • Replace all three batteries at the
same time.
Scale does not proceed to
analyse body composition.
• Taking a measurement
while wearing shoes or
socks.
• Stand barefoot on the scale and
keep feet in full contact with
the electrodes when taking a
measurement.
• Using the weight-only
measuring mode in the
EufyLife app.
• Change the measuring mode in
the EufyLife app.
Specifications
Power Source 4.5 V (3 ×AAA batteries)
LED Display 2.6 × 1.2 in / 67 × 29 mm
Measurement Unitse Pound / Kilogram
Unit Increments 0.1 lb / 0.1 kg
Body Fat Unit Increments 0.1 %
Body Water Unit Increments 0.1 %
Muscle Mass Unit Increments 0.1 %
Measurement Range 11-397 lb / 5-180 kg
Working Environment Temperature: 5 - 40 °C
Humidity: 20 - 90% RH
Storage Environment Temperature: -20 - 50 °C
Humidity: <= 90% RH
Operating Frequency Range 2402 - 2480 MHz
Radio-Frequency Power 4 dBm

ةيبرعلا
AR
10
English
Dimension 11.0 × 11.0 × 0.9 in / 280 × 280 × 24 mm
Net Weight 3.31 lb / 1. 5 kg
Customer Service
For FAQs and more information, please visit www.eufylife.com.
Email: [email protected]
support.mea@anker.com
Live Chat: www.eufylife.com
15-month limited warranty
(US) +1 (800) 988 7973 Mon-Fri 9:00am - 5:00pm (PT)
(UAE) +971 8000320817 Sun-Thu 9:00-17:30
(KSA) +966 8008500030 Sun-Thu 8:00-16:30
(KW) +965 22069086 Sun-Thu 8:00-16:30
@EufyOcial
Anker Innovations Limited
Room 1318-19, Hollywood Plaza, 610 Nathan Road, Mongkok, Kowloon, Hong Kong
•
•
•16
•
•
•
•
•
30
12
•
•

ةيبرعلا
ةيبرعلا
AR AR
•
•
•AAA
•
•
Li-ion
NiMH
•
•
•
•
•
•
•
•
•
Anker Innovations Limited
2014/53/T9147
EU
.https://www.eufylife.com
4
2.48352.40002.4

ةيبرعلا
ةيبرعلا
AR AR
P1 3
AAA
AAA
.LED
.LED
LED
kglb
EufyLife
EufyLife
GoogleiOSEufyLife
AndroidPlay
Bluetooth
EufyLife
Bluetooth ON
Smart Scale
EufyLife

ةيبرعلا
ةيبرعلا
AR AR
9.0 iOS
4.4 Android
Bluetooth
EufyLife
.EufyLife
EufyLife
.EufyLife
.LED

ةيبرعلا
ةيبرعلا
AR AR
.AAA LED
.EufyLife
.EufyLife
AAA34.5
LED29 × 671.2 × 2.6
0.10.1
% 0.1
% 0.1
% 0.1
5-18011-397
40 - 5
20-90%
50 - -20
90%
2480 - 2402
4
24 × 280 × 2800.9 × 11.0 × 11.0
5 .13.31
.www.eufylife.com
[email protected]
support.mea@anker.com
www.eufylife.com
15
(US) +1 (800) 988 7973 Mon-Fri 9:00am - 5:00pm (PT)
(UAE) +971 8000320817 Sun-Thu 9:00-17:30
(KSA) +966 8008500030 Sun-Thu 8:00-16:30
(KW) +965 22069086 Sun-Thu 8:00-16:30
@EufyOcial

Table of contents
Languages:
Other EUFY Scale manuals
Popular Scale manuals by other brands

cecotec
cecotec SURFACE PRECISION 9500 SMARTH HEALTHY instruction manual

Minebea Intec
Minebea Intec Puro EF-4PDDP Series operating instructions

Avanti
Avanti 16856 user guide

PCE Instruments
PCE Instruments PCE-PB-N series instruction manual

Rice Lake
Rice Lake 350-10-8S Technical manual

IRIT
IRIT IR-7118 Manual instruction