EURGEEN OL12-010-2E User manual

INSTRUCTION MANUAL
Please keep this manual safe for further reference!
Thank you for selecting our super-quality dehumidifier. Please be sure to read this
manual carefully before using it. Any questions, please contact the customer service
for help. Keep this manual for future reference.
The dehumidifier will remove excess moisture from the air, creating a comfortable
environment for your home and office. Its compact design allows it to be easily moved
between rooms.

1
CONTENTS
CONTENTS…...............................................................................................1
CAUTIONS…................................................................................................2
OPERATIONS…...........................................................................................3
WATER DRAINAGE…..................................................................................6
MAINTENANCE…........................................................................................7
TROUBLE SHOOTING…..............................................................................8

2
CAUTIONS
Please read the operating instructions carefully before using your dehumidifier
for the first time.
1.
Install the unit on flat and hard floor to diminish vibration or noise.
2.
Never immerse the unit in water or other liquids.
3.
Never operate the unit if the cable or other connector is damaged, or something
abnormal may happen, please call customer service for help.
4.
Disconnect the unit from the power supply when it is not in use, or before relocating or
cleaning it.
5. Operate the unit only at the voltage specified.
6. The unit is for indoor use only. Don’t use it for any other purpose.
7. Do not put heavy objects on the appliance.
8. Do not tip the unit to one side as spilt water could damage the appliance.
9.
Never insert any other object into the unit body to avoid any hazard or unit failure.
10.
Do not put the unit close to heat-generating devices or near flammable and
dangerous materials.
11. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with the
appliance.
12. If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard
13. The appliance must be positioned so that the plug is accessible
14. The appliance shall be installed in accordance with national wiring regulations
15. The ambient temperature range for the appliance is 5°-35°
Don’t try to repair, dismantle or remold the appliance, as could irreparably
damage the appliance. Even changing the power cord should be done by
qualified person.

3
OPERATIONS

4
POWER
When power is on, the panel shows blue. Press this button to turn the unit on /off. Do not
unplug the power cord directly to force the machine to stop working.
Press the “POWER” key, machine run and enter CONT (Continuously dehumidification) mode
automatically. The “POWER” and “CONT” indicator lights show orange. The fan speed is high by
default, and the “SPEED” indicator light shows red.
Press the “POWER” key again, the machine is turned off, the fan delay shuts down in 10
seconds.
In the mode of “CONT”, we can set up the SPEED, TIMER, UN and other functions.
HUMSET
Press this key, the system exits the CONT mode and enters the smart mode.
Press this button to adjust humidity as following (the initial humidity is 60%), from
60%→65%→70%→75%→80%→40%→45%→50%→55%→60%. When the indoor
humidity is lower than the set humidity, the machine will stop automatically.
After set the humidity in 5 seconds, the machine show the current environment humidity.
Long press this button for 3 seconds to query the current environmental humidity.
When we set the humidity is “--%”, the system enter the CONT mode, 5 seconds later,
“HUMSET” indicator light turns off and the “CONT” indicator lights up.
TIMER
24 hours timer
Press this button to set timer on/off, if you would like to cancel the timer setting, press this
button until 00 is shown on the display.
SPEED
Press this button to adjust the fan speed between HIGH and LOW.
At high speed the indicator light shows red, at low speed the indicator light shows blue.

5
ION
Press this button to turn on and off the ionizer function.
The purifying function can separate open: when power is on, press this key, the motor starts,
the compressor does not start, separately used for air purification, still can set the timer and
adjust the fan speed at this time.
Double “88” display
1. When the machine is running, shows the current humidity,
2. When the user sets the humidity, it shows the humidity set.
3. When the user sets the timer, its show the time set.
4. When the user long presses “HUMSET”for 3 seconds, it shows the current humidity.
When current humidity<20%, shows “LO”
When current humidity>95%, shows “HI”
Digital color:
1. When the humidity is appropriate, the digital display is blue.
2. When the humidity is high, the digital display is green.
3.
When the humidity is too high or too low, the digital display is red.
Water full indication
When the water tank is full, the indicator light shows red and the unit will buzz for 15 times and
then stop. You must empty the water tank and put it back to the correct position.

6
WATER DRAINAGE
Water Tank
The Water full indicator will show red when the water tank is full, warning will be given.
Take out the water tank (FIG 1) and empty the water inside.
Put the water tank back into the dehumidifier
Continuous drainage
Take out the water tank first, and connect the pipe with the outfall (FIG 2), connect the other
end of the pipe to a floor drain or other container such as a bucket (FIG 3), finally put the
water tank into the dehumidifier.
Caution:
1. Never block the water outlet or the pipe, water will flow into the water tank if it
is blocked.
2. Never bend the drainage pipe and ensure it is always lower than the outlet.
3. Must close the cover when no need continuous drainage.
NOTICE:
1. When the machine is running, take out the water tank, the machine will stop.
2. Water tank is the default drainage .
3. Don’t remove the float from the water tank (FIG 4), if you do this, the machine will show
“FULL”, and stop working.
4. Drain the water collection tank completely when water tank is full and reset your setting
5. If the water tank is dirty, clean by cool or warm water, do not use cleaner, steel wool,
chemical rag duster, gas oil, benzene, thinner or other solvent to clean it, otherwise, it
would damage the water tank and lead to leakage
6. When putting the water tank back in the unit, please use two hands to push the water tank
into the machine to the correct position. If not correctly positioned the full indication will
still show red and the machine will not work.
FIG 1 FIG 2 FIG 3 FIG 4

7
MAINTENANCE
NOTE:TURN OFF THE UNIT AND UNPLUG IT BEFORE ANY
MAINTENANCE OR REPAIR TO AVOID ELECTRIC SHOCKS.
Cleaning
Unplug the unit before any cleaning.
Clean the housing with a soft moist cloth. Do not use chemical solvent (such as benzene,
alcohol, gasoline).The surface may be damaged or even the whole case may be deformed.
Do not sprinkle water on the unit.
Air filter
The unit is equipped with a washable air filter. Take out the washable filter. After cleaning
insert the filter back to its place.
Clean the washable filter every 2 weeks. If the filter is blocked with dust, the efficiency of the
appliance will reduce.
Wash the air filter by immersing it gently into warm (about 40°) water with a neutral
detergent, rinse it and dry it thoroughly in a shaded place.
Dehumidifier storage
If the dehumidifier will not be used for an extended period of time:
1. Drain the water tank completely and make sure no water is left inside.
2. Unplug the unit and fold up the power supply cord.
3. Remove and clean the air filter, allow it to dry completely and reinstall it.
4. Store the dehumidifier in a cool, dry location, away from direct sunlight, extreme
temperature and excessive dust.

8
TROUBLE SHOOTING
BEFORE CALLING FOR SERVICE
Before contacting customer services, review this list. It may save you expense and time.
This list includes common occurrences that are not the result of a defect in workmanship or
materials.
Problem
Possible Cause
Solution
The unit doesn't operate
No power supply
Connect to a functioning outlet and
switch on
Water Full Indication Flash
Drain water tank and reset your
setting, or replace the water tank to
right place
Room temperature under 5
degree, the error shows ”CL”;
above 38 degree, the error
shows “CH”
Self-Protection designed to protect the
unit. Cannot work under such
temperature
Timer function is active.
Deactivate Timer function.
The dehumidifying
function doesn't work
or the unit turn on / off
frequently
Is the air filter clogged?
Clean the air filter as instructions
Is the door/window
opened?
Close the door / window
Is the unit close any heat
emanation?
Remove the unit to a cool place
Is the intake duct or discharge
duct obstructed?
Remove the obstruction from the
discharge duct or intake duct.
E1
Evaporator sensor problem
Connection mouth pull out and
connect it again, or change the sensor.
E2
Humidity sensor problem
Connection mouth pull out and
connect it again, or change the sensor.
Cautions: Switch off the unit and unplug it immediately if anything abnormal
happens. Then contact a qualified electrician.
Table of contents
Other EURGEEN Dehumidifier manuals