European Touch FORTE' User manual

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 1 of 24
The World's Finest Pedicure Spas
Solace Spas
Owner s Manual
FORTE’and ALTERA
Crystal Clean Pipe-Free
&
Traditional Whirlpool

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 2 of 24
European Touch - Limited Warranty
EUROPEAN TOUCH manufactures the Sol ace®
Whirlpool Pedicure Spa with the highest standards for
quality materials and workmanship accordingly; EUROPEAN TOUCH expressly warrants their products as
follows:
To the original owner of the Solace®Whirlpool Pedicure Spa (herein called "pedicure spa"): EUROPEAN
TOUCH may repair or replace at its option, any pedicure spa found to be defective in materi al or
workmanship upon inspection by an authorized representative of EUROPEAN TOUCH. This warranty
covers the following components for the following time periods:
•Recirculating Pump: Two (2) years from date of shipment.
•All other components: One (1) year from date of shipment.
The exchange of a pedicure spa is limited to supplying a replacement pedicure spa of comparable
style and size. EUROPEAN TOUCH may, at its ow n discretion, use refurbished parts or pedicure
spas for replacement purposes. Owner must pay all labor and shipping charges necessary to
replace or repair the pedicure spa. NO CONSEQUENTIAL, INCIDENT AL, OR CONTINGENT
DAMAGES WILL BE ALLOWED WHATSOEVER. This warranty is null and void if the pedicure spa is
removed from its place of initial installation, or is not installed in accordance with federal, state or local
codes and ordinances. Furthermore, this warranty does not apply if the pedicure spa has been subject to
misapplication, improper installation or maintenance, negligence, improper cleaning or other circumstances
beyond EUROPEAN TOUCH's control .
NOT COVERED
1) Damage to pump parts and/ormotor parts due to obstruction in plumbing lines, etc.
2) Staining, fading or discoloration of plastic surfaces due to exposure and/or the use of harmful
cl eani ng agen ts o r chemi cal s.
3) Staining, fading or discoloration caused by improper or poor water additives not related to
maintenance of proper water are not covered by this warranty.
4) Malfunctions or damage caused by improper installation; including not meeting local and state
plumbing, electrical, and building codes.
5) Staining, fading or discoloration of the vinyl seat, armrests or footrest.
6) Damage resulting from standing in the basin.
7) Freight damage, misuse, neglect, accident, natural disaster, and abuse.
8) Unauthorized repairs.
Should service be required for any reason of any defect or any malfunction during the warranty period,
please contact:
EUROPEAN TOUCH
Technical Support
8301 W. Parkland Court
Milwaukee, WI 53223
Phone Number: 414-357-7016
Toll Free: 1-800-626-6912
Fax: 414-357-6360
http://www.europeantouch.com
The owner agrees by using this pedicure spa that the obligation of EUROPEAN TOUCH shal l not extend to
indirect or contingent damage, of injury, which may result from such use that the obligation of EUROPEAN
TOUCH are limited to those set forth herein, and other obligations, expressed or implied are assumed by
EUROPEAN TOUCH.
No dealer or other person has any authority to bind EUROPEAN T OUCH to changes or additions to this
warranty or its products. Accordingly, EUROPEAN T OUCH is not responsible for any such warranties or
representations.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 3 of 24
Certificate of Compliance
For
European Touch
8301 W. Parkland Court
M ilwaukee, WI
U.S.A. 53223
For Comp liance of:
Equipment : Whirlpool Pedicure Spa
Model No.: SOLACE – PF & SOLACE – PF PDP
Rated: 220-240VAC, 50Hz, 7.5A
To the following standard(s):
EN60335-1:2002
EN60335-2-32:2002
EN 55014-1 (Generic): 2001
EN 55014-2 (Generic): 2003
EN61000-4-2 (Criteria C): 2001
EN61000-4-3:2002
EN61000-4-4: 1995
EN61000-4-5: 2001
EN610004-6: 2001
EN61000-4-11: 2004
Project No.: 8311-1 Issued by:
Issue Date: December 30, 2005
President
Expiry Date: December 30, 2008
ONE STOP GLOBAL CERTIFICATION SOLUTIONS
Refer to projec t file for compl ete inf or ma tion on Cer tificat e

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 4 of 24
OWNERS MANUAL For
Solace®Whirlpool Pedicure Spa Models:
FORTE’and ALTERA
Important Information
Serial Number:
W/O Number:
Installed by:
Ins tallation Date:
Serial Number
W/O Number
Note: Vietnamese and Korean translations available upon request.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 5 of 24
Table of Contents
European Touch - Limited Warranty ..................................................................................................... 2
Certificate Of Compliance....................................................................................................................... 3
Important Information............................................................................................................................... 4
Introduction................................................................................................................................................ 6
Important Requirements.......................................................................................................................... 6
Precautions............................................................................................................................................ 6
Health Risk Warning ............................................................................................................................ 6
Ins tallation Specifications Summary...................................................................................................... 7
Location And Support.......................................................................................................................... 7
Important Installation And Utility Information....................................................................................... 8
Dimensional Drawings............................................................................................................................. 9
Crystal Clean™ Pipe-Free® And Traditional Whirlpool (With Jets)............................................. 9
Crystal Clean™Pipe-Free®...............................................................................................................10
Traditional Whirlpool (With Jets)......................................................................................................11
Specifications..........................................................................................................................................12
Unpacking The Cushions......................................................................................................................14
Remote Control Configurations............................................................................................................14
Attaching The Cushions ........................................................................................................................15
Component Reference..........................................................................................................................16
Pedicure Product Guidelines................................................................................................................16
Crystal Clean™Pipe-Free®Spa - Operating Instructions ................................................................17
Crystal Clean™Pipe-Free®Spa - Cleaning And Disinfecting Procedures ....................................18
Traditional Whirlpool (With Jets) - Operating Instructions ...............................................................19
Traditional Whirlpool (With Jets) - Spa Cleaning And Disinfecting Procedures...........................20
Removal / Replacing Jet Parts .........................................................................................................21
Removal / Replacing Suction Cover................................................................................................21
Removing / Replacing Drain Handle...............................................................................................22
Removing / Replacing Impeller........................................................................................................22
History And Notes ..................................................................................................................................23

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 6 of 24
Introduction
Thank you for selecting EUROPEA N TOUCH, the leading designer, manufacturer, and marketer of
pedicure spas in North A merica. The Solace®Forte’ and Solace®Altera pedicure spas (herein referred
to as pedicure spa) are innovative w hirlpool pedicure spas that have been designed to serve you
dependably for many years. Please take time to thoroughly read this entire manual before installation
and use. If you have any problems or have questions regarding your pedicure spa, please contact
EUROPEA N TOUCH’s Technical Support Department at 1-800-626-6912, Monday through Friday 8
AM to 5 PM CST. Af ter hours calls are recorded and attended to the next business day.
Important Requirements
EUROPEA N TOUCH requires that you contact a local, licensed plumber and licensed electrician to
install your new pedicure spa. Installation must be in compliance w ith all your local and state building
codes. Your pedicure spa cannot operate efficiently or safely unless it is provided w ith adequate
electrical pow er, sufficient w ater pressure, proper water temperature, and required drainage
capabilities. Contact your local building inspector f or information and local code compliance
procedures that need to be follow ed w hen having your pedicure spa installed. Subsequent inspections
and approvals that may be required are the responsibility of the purchaser. (See lim ited w arranty
regarding incidental or consequential exclusions – page 2).
Precautions
•Do not stand in the basin of the pedicure spa!
•Excessive water temperature is dangerous and should be checked before use.
Maximum operating water temperature should not exceed 105°F (41°C) and the
maximum supply water temperature should not exceed 150°F (66°C).
•Always enter and exit the pedicure spa slowly and carefully.
•Close side arms rests before operating the chair seat movement.
•Never bring or operate any electrical devices into or near the pedicure spa.
•This pedicure spa has a weight capacity of 250 pounds (113.4kg).
Health Risk Warning
Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use
the pedicure spa at any time. Nail technicians should advise clients to consult their physician
before using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or
persistent pain. In some cases diabetics may experience improved circulation in their feet, but
should first consult their physician prior to receiving a pedicure. If the client experiences any
pain or discomfort, immediately discontinue t he use of the pedicure spa.
Your client’s massage and pedicure spa experience should be pleasant and comfortable.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 7 of 24
Installation Specifications Summary
Note: Failure to comply with federal, state or local codes and ordinances will result in the warranty
being null and void.
As stated, the pedicure spa installation must comply w ith all plumbing and electrical codes. A licensed
plumber and licensed electrician must complete the applicable connections of the pedicure spa.
Location and Support
Select a level location. The floor structure beneath the pedicure spa must be capable of supporting the
occupied pedicure spa.
For the seat back to fully recline, the pedicure spa base must be mounted a minimum distance from the
w all:
Forte’ model w ith full recline option 25” (64 cm
)
Forte’ model 18” (46 cm
)
Altera model 12” (31 cm
)
= “X” dimension, below , by model.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 8 of 24
Important Installation and Utility Information
Electrical Service:
110V: A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power
to the pedicure spa. (220V if ordered in 220V configuration)
220V: A 220-240VAC, 50Hz, 7.5 Amp GFCI protected grounded circuit must be used to supply
pow er to the pedicure spa per local code.
Water Supply:
All plumbing connections must conform to local codes.
Nor mal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
The hot w ater supply temperature must not exceed 150°F (65°C). Adjust your hot w ater heater
accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below .
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply w ith
ANSI/ASME A112.18.3M, A112.18.1M, and CSA B125
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air
gap. Included in the possible range of applications are fittings w ith hose connected outlets, fittings w ith
pullout spout, hand held show ers, shampoo fittings and deck- mounted fittings. ASME A112.18.3M is
now referenced in ASME A112.18.1M ( Plumbing Fixture Fittings) and CSA B125. Check valves are
listed to both standards w ith the Canadian Standards Association, IAPMO and UL.
ANSI - A merican National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underw riters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided) must
be installed by a licensed plumber.
Pedicure spa must be securely fastened to the floor as show n in figure 2 below . Fasten the pedicure
spa to the floor w ith at least tw o fasteners, one in the middle plastic support and one in the rear plastic
support.
Back of Pedicure Spa Install Fasteners Here
Figure 1 Figure 2

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 9 of 24
Dimensional Drawings
Crystal Clean™ Pipe-Free® and
Traditional Whirlpool (With Jets)

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 10 of 24
Crystal Clean™Pipe-Free®

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 11 of 24
Traditional Whirlpool (With Jets)

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 12 of 24
Specifications
Hot and cold w ater supply lines required (hot and cold shut offs may be installed under pedicure spa
base) See pages seven through ten.
Drain installation: references noted on pages seven through ten, can be installed with optional
pow er drain pump or as gravity drain.
Overall dimensions without accessories, seat upright: 54" (138cm) L x 31" (79cm) W x 56" (143cm) H*
Without accessories, seat collapsed: (shipping position): 54" (138cm) L x 32" (82cm) W x 36" (92cm) H*
Shipping dimensions: 55" (140cm) L x 33" (84cm) W x 41" (105cm) H*
Em pty weight: 150 Ibs (68kg)*
Shipping weight: 205 lbs (93kg)*
Capacity of basin: 5 U.S. Gallons (18.9L) = Traditional Whirlpool (with Jets)*
6.5 U.S. Gallons (25.6L) = Crystal Clean™Pipe-Free®*
Whirlpool pump motor: 110V: 1/6 HP, 110V, 60HZ (alternate voltages available) (3/4 HP f or Traditional
Whirlpool - wi th J ets)
220V: 1/6 HP, 110V, 50Hz (alternate voltages available) (3/4 HP for Traditional
Whirlpool - wi th J ets)
Forte’ seat and back motors: 30V DC Linear Actuators. Forte’ requires 18” (46 cm) of space betw een
pedicure spa and w all w ith standard actuator, and 25" (64 cm) w ith fully-reclining
actuator.*
Altera seat and back movement: 2 infinitely adjustable lockable gas cylinders for reclining/sliding. The
Altera requires 12" (31cm) of space between pedicure spa and wall in order for
seat to recline to its fullest extent.*
Massage motor: 12V AC, Adapter included (alternate voltages available)
Power source: 110V: 110V AC / 15 Amp, 60 Hz (GFCI Protected)
220V: 220-240VAC, 50Hz, 7.5 Amp (GFCI Protected)
Caution: Pedicure spa must be installed by a licensed electrician and a licensed plumber,
conforming to all local and national electrical codes.
Cons truct ion: Linear Low Density Polyethylene (LLDPE), self-contained, pre-plumbed
Crystal Clean™Pipe-Free ®w ater m assage s ystem (pipe-free pedicure spas): 'underfoot' footplate
water massage grooves, no closed loop circulating pipes, 100% fully drained,
and cleanable
Hydro-Therapeutic (Jet System: Traditional Whirlpool pedicure spas): PVC, two (2) fully-directional
jets, built-in air control
Electrical switches: On/Off switch f or whirlpool pump. Hand-held low voltage remote controls for
massage motors, heat, and seat/back position hot and cold w ater supply lines
required
UL listed/CE certified: Complies w ith ASME/ANSI Whirlpool Bathtub Specs ASME/ANSI A112.19 7M-
1995 and A112.19.8M-1995. Backflow Protection Devices for Faucets w ith Side
Spray: Check valves comply w ith ANSI/ASME A112.18.3M, A112.18.1M, and
CSA B125.
Performance Lim its : 1. This unit may loose one ore more functions w hen electrostatic contact
discharge in excess of 4KV gets into accessible conductive part of the unit and
can be restored by resetting the unit.
2. This unit may loose one ore more functions w hen power surge in excess of
2KV is applied to the AC input power port and can be restored by resetting the
unit.
3. This unit may loose one ore more functions when subjected to fast transient
voltages in excess of 0.5KV at 5 KHz repetition frequency and can not be
restored.
Limited warranty: One (1) year from date of purchase.
Due to our policy of continuous improvements, all specifications are subject to change without notice.
*Note: All dimensionsand weights are approximate

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 13 of 24
Attaching the Seat Back
Your pedicure spa shipped w ith the seat bottom and seat back already attached to the base. Follow
these instructions to connect the seat back to the pedicure spa:
Forte’ Altera
Step 1: Remove the hitch and clevis pins located
on the seat back mounting bracket on the back of
the chair.
Step 1: Remove the hitch and clevis pins
located on the seat back mounting bracket on
the back of the chair.
Step 2: Slide the seat bracket into the black end
on the linear actuator, and line up the holes.
Step 2: Line up the hole on the seat bracket w ith
the hole on the cylinder end.
Step 3: Slide the clevis pin through the holes and
secure by inserting the hitch pin through the
small hole on the clevis pin.
Step 3: Slide the clevis pin through the holes
and secure by inserting the hitch pin through the
end hole on the clevis pin.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 14 of 24
Unpacking the Cushions
Your cushion set is packaged in its own box w ithin the pedicure spa shipping carton. All needed parts
are located inside of this box. These include:
•(1) Seat Back
•(1) Seat Bottom
•(2) Arm Cushions
oAltera Vibration Massage Only: The remote and junction box
Please make sure that all parts are removed from the box before discarding the box. If any parts are
missing, the customer must contact EUROPEAN TOUCH w ithin 30 days of the delivery date for
replacement at 800-626-6912.
Remote Control Configurations
Recline S eat Bac k:
Tilt Bac kward or
Forward.
Forte’
Seat Movement
M ove S eat Bot to m:
Slide For ward or
Bac kward.
Indicates that
Vi brate Fea ture i s
Activated.
Type of Vibrating
Massage: (Surge,
Steady, Pulse,
Wa ve).
Incr eas e or
Decrease Int ensit y
of vibrati ng
mass ag e.
Forte’/Altera
Roller
Timer (15 min or 30
mi n) .
Indicates that Roller
Featur e i s Acti vate d.
Ar ea of Vi bratio n:
Zone 1 = U p per.
Zone 2 = L o wer.
Incr eas e or
Decr ease Sp ee d of
vibrating massage.
Numerical Display
shows intensity levels.
LEDs show type of
FULL-BODY
Massage.
Select from 5 types of
FULL-BODY
Massages as
indicated by LEDs
above.
Adjust intensities Up
or Down.
Power On/Off:
automatically selects
15 min timer. Holding
switch for over 3
seconds activates 30
min timer as indicated
by LED above.
Forte’
Vibration
Numerical Display
indicates ten levels
of wave speed.
LED shows selected
Timer.
LED shows selected
Heat setting.
Select from 5 types
of BACK Massages
as indicated by LEDs
above.
Adjust Wave Speed
Up or Down.
Select Hi or Lo Heat
as shown by LEDs
above.
Activates the Massage
Zone 1.
Power On/Off.
Activates Massage
Wave.
Adjusts Intensity Up or
Down.
Adjusts Speed Up or
Down.
Altera
Vibration
LED Shows
Massage Zone
Activated.
LED Shows Selected
Massage Time.
Activates the
Massage Zone 2.
Timer Selects
(Indicated i n LEDs
Above).
Sets Massage on
Steady.
Adjusts Sensate Up
or Down.
Moving Display indicates
speed and pattern of Back
Massage.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 15 of 24
Attaching the Cushions
All pedicure spa cushions attach to the pedicure spa with Velcro. The Forte' and Altera Pedicure spas
have cables for the cushions that need to be routed proper ly. Follow these instructions for attaching
the cushions properly to your pedicure spa:
Step 1: Your pedicure spa will
come wi th the Velcro already in
place for the seat bottom and the
seat back.
Step 4: Remove the protective film
from the Velcro on the bottom of
the arm pads. Carefully place the
arm pads on the chair arms and
slide the remotes under the remote
holders on the arm pads.
Step 7: AL TERA VIBRATION
ONLY – The Altera cushion remote
control comes attached to the
j uncti on bo x.
Step 2: Attach the seat bottom to
the chair bottom. Make sure that
the cu shion i s centered on the
chair bottom. The arms should be
able to close without cushion
interference.
Step 5: FORTE' ONLY – T he
remote control and power supply
cord are taped together behind the
chai r. Remove the tape and
connect the cords from the cushion
to these connectors.
Step 8: AL TERA VIBRATION
ONLY – The Altera junction box
should be mounted on the back of
the seat back. Plug the 2 cushion
cords into the red and white
receptacles (they can go into either
receptacle). The power supply
cord pl ug s i nto the re ceptacl e ne xt
to the remote cord. Plug the power
supply into the power strip.
Step 3: Route the seat back
cushion cables underneath the
chair back and out the back.
Center the seatback cushion on
the ch ai r ba ck.
Step 6: FORTE' ONLY – Route
the seat back cables through the
hole in the pedicure spa base.
Step 9: The remotes can be
slipped into the ar mrests as
show n.
Note: Close side arms rests before
operating the chair seat movement.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 16 of 24
Component Reference
Crystal Clean™Pipe-Free®
Inside Basin View
Crystal Clean™Pipe-Free®
Front View
Traditional Whirlpool (with Jets)
Inside Basin View
Traditional Whirlpool (with Jets)
Front View
Pedicure Product Guidelines
Because there are so many different products on the mar ket, it is difficult for us to list all of the pedicure
products that are safe to use in our pedicure spas. How ever, the f ollow ing guidelines can be used:
•It is your responsibility to understand and follow your state’s regulations regarding product usage
and disinfecting requirements.
•Do not use any products containing a foaming agent; this w ill cause excessive foam.
•It has been determined that products containing non-dissolving abrasives (such as sand and sea
salts) w ill not harm the internal component structure of your pedicure spa as long as the entire
EUROPEA N TOUCH cleaning requirements are follow ed w ithout deviation.
•Oil based products may be used in your pedicure spa as long as the cleaning requirements are
met.
•Please use pedicure products and cleaning solutions in accordance w ith each manufacturer's
directions.
EUROPEA N TOUCH w hirlpool pedicure spas w ill g ive you many years of service as long as proper
precautions and precise cleaning and operating instructions are f ollow ed. It is the responsibility of the
pedicure spa ow ner to properly clean the pedicure spa.
If you are experiencing problems cleaning your pedicure spa, please contact the manufacturer of your
pedicure products or EUROPEA N TOUCH Technical Support at 800-626-6912.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 17 of 24
Crystal Clean™Pipe-Free®Spa - Operating Instructions
Preparing the Pedicure Spa for Operation:
After the pedicure spa is installed and the plumbing and electrical connections are made, clean and
disinfect the basin before initial use. Rinse the basin by using the attached w ater sprayer. Wipe the
basin dry w ith a clean tow el.
To Operate the Pedicure Spa, Follow These Easy Steps:
Adding Water to the Pedicure Spa Basin:
1. Close the drain by turning the chrome drain handle counter-clockw ise until it stops.
2. Add water to the basin by lifting upw ard on the w ater faucet fill handle. Turn the handle in a
counter-clockw ise direction for cold water or clockwise for warm w ater as indicated by the red
(hot) and blue (cold) markings around the handle ( CAUTION: hot w ater can burn skin). Continue
to add w ater until the fill lin e is reached. The fill line is indicated by the w avy (~~~~) line in the
basin.
3. Turn the off water by pushing the handle dow nward and center.
Operating the Crystal Clean™Pipe-Free ®System :
The Crystal Clean™Pipe-Free®System eliminates pipes and jets that can harbor har mful bacteria w hile
at the same time delivering a soothing, quality foot massage. This unique system is driven by an
impeller that pulls w ater through the inlet cover and then forces the w ater outward through key
massage zones in the footplate. The end result is a soothing massage delivered to all areas of the foot:
front, back and bottom.
To start or stop the w hirlpool, depress the On/Off button labeled “Jets” (NOTE: An indicator light on
the “Jets” button flashes when the footplate is improperly installed, or the basin contains no
water. As a result, the whirlpool will not function. To fix, simply check that the footplate is
securely fastened or add water to the basin).
Removing Water from the Pedicure Spa Basin:
First, make certain the w hirlpool jets are turned off by turning the On/Off switch counter-clockw ise to the
“Off” position.
If the pedicure spa is hooked up directly to a floor drain, simply open the drain by turning the drain
handle in a clockw ise direction until it stops. You should see the w ater level low ering as w ater exits the
basin.
If the pedicure spa is equipped w ith the optional Pow er Drain Pump ( PDP) feature, open the drain by
turning the drain handle in a clockw ise direction until it stops. Press the button marked “Drain” on the
front panel. The w ater level w ill low er as w ater is pumped out of the basin. Turn the pump off by
pressing the “Drain” button on the f ront panel once the basin is fully drained (NOTE: the PDP will
automatically shut off after 2-1/2 minutes. We recommend turning off the pump manually if all
water has drained before automatic shut-off. Drain pump may overheat if operated more than
10 minutes in a 45 minutes period).
Warning:
It is extremely important to follow the cleaning instructions located on the following page.
F ai l ur e t o cl ea n t h e p edi c ur e spa a d e qu a t el y ca n r esu lt i n ser i ou s h eal th i ssu e s f o r you r cl i en t s
as well as the nail technician. Faili ng to clean your pedicure spa may also cause the pedicure
spa to not work properly. Please consult your local and state codes concerning pedicure chair
cleaning for further requirements.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 18 of 24
Crystal Clean™Pipe-Free®Spa - Cleaning and Disinfecting
Procedures
Please check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of
the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good
working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection.
To cleanthe pedicure spa, follow these easysteps:
After Each Pedicure:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Loosen the footplate by turning the footplate Tee Knobs in a counter-clockwise direction. Remove the
footplate from the basin by lifting upward on the inlet cover. (NOTE: Gently press down on the
footplate center when loosening the footplate Tee Knobs, as this will relieve pressure and help
loosen the Tee Knobs.)
3. Remov e all debris from the basin.
4. Clean all the surfaces of the basin and all components, as well as the top and bottom of the footplate and
both Tee Knobs. Use low-sudsing soap or detergent and a non-abrasive brush. Remove all visible
residue from the inside of the basin and all other components. Clean off sensor on bottom of basin.
5. Rinse the basin with clean water using the sprayer.
6. Disinfect all components, surfaces, basin, top and bottom of footplate, and footplate Tee Knobs with an
EPA-registered disinfectant, in accordance with your state board requirements. *EPA disinfectants
require ten-minute contact.
7. Rinse the basin again with clean water using the sprayer.
8. Thoroughly dry the basin and all other components with a clean towel.
9. Replace the footplate and secure by simultaneously turning both footplate Tee Knobs in a clockwise
direction. (NOTE: When replacing the footplate, carefully align the mounting studs with the
mounting holes. Tighten each knob until snug. Be careful not to over-tighten, as this can damage
the Tee Knobs.)
After Last Pedicure of the Day:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Remove the drain cover as shown on page 21. Remove the impeller as shown on page 21. Remove all
debris. Then wash with low-sudsing soap or detergent using a soft brush. Disinfect the impeller and
drain cover as well as the area behind the drain cover. Replace drain cover and impeller.
3. Next repeat steps two through seven above as in “After Each Pedicure.”
4. After all components are put back into place, fill basin with clean warm water to the fill line.
5. Pour three teaspoons of low-foaming dishwasher crystals, (not gel) and 1 ounce of household bleach for
up to six gallons of water.
Follow your state board requirements as they may differ from the above step.
6. Turn on the whirlpool and let run for ten minutes.
7. Turn the whirlpool off and drain water from the basin.
8. Using the sprayer, rinse off all components, surfaces, and basin.
9. Refill the basin with clean waterand turn the whirlpool on. Run for one minute to rinse.
10. Drain water from the basin and turn off the whirlpool.
11. Wipe dry with clean towel.
12. Make a record of the date and time of this cleaning and disinfecting.
Once a Week Overnight Cleaning:
In addition to the daily cleaning, the following cleaning procedures must be done every week:
1. Follow steps one through fiv e above, as in “After the Last Pedicure of the Day.”
2. Turn on the whirlpool and let run for ten minutes.
3. Turn the whirlpool off and let the water sit overnight in the basin (six to ten hours).
4. In the morning, run the whirlpool for five minutes and drain the basin.
5. Rinse the basin with clean water using the sprayerand dry with a clean towel.
6. Make a record of the date and time of this cleaning and disinfecting.
CAUT IO N: Cleaning products that contain abrasives can damage the pedicure spa. Use
ONLY non-abrasive products to clean the pedicure spa.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 19 of 24
Traditional Whirlpool (With Jets) -Operating Instructions
After the pedicure spa is installed and the plumbing and electrical connections are made, clean and
disinfect the basin before initial use. Rinse the basin by using the attached w ater sprayer. Wipe the
basin dry w ith a clean tow el.
To Operate the Pedicure Spa, Follow These Easy Steps:
Adding Water to the Pedicure Spa Basin:
1. Close the drain by turning the chrome drain handle counter-clockw ise until it stops.
2. Add water to the basin by lifting upw ard on the w ater faucet fill handle. Turn the handle in a
counter-clockw ise direction for cold water or clockwise for warm w ater as indicated by the red
(hot) and blue (cold) markings around the handle ( CAUTION: hot w ater can burn skin). Continue
to add w ater until the fill lin e is reached. The fill line is indicated by the w avy (~~~~) line in the
basin.
3. Turn the off water by pushing the handle dow nward and center.
Ope r ating the Water Je ts :
Each pedicure spa is equipped w ith tw o f ully adjustable jets that create a soothing foot massage. To
operate, turn the w hirlpool jets on by turning the On/Off Sw itch in a clockw ise direction. To increase jet
strength, open each jet by simply rotating the adjustment cover in a counter-clockw ise direction. To
decrease water pressure, close each jet by rotating the adjustment cover in a clockw ise direction
(NOTE: The Jet heads should not be positioned directly at the suction cover. Doing so will
create a noisy “gurgling” sound as air is being forced directly into water pipes). Turn off the
whirlpool jets by turning the On/Off sw itch counter-clockw ise to its original starting position.
Removing Water from the Pedicure Spa Basin:
First, make certain the w hirlpool jets are off by turning the On/Off Sw itch counter-clockw ise to the “Off”
position.
If the pedicure spa is hooked up directly to a floor drain, simply open the drain by turning the drain
handle in a clockw ise direction until it stops. You should see the w ater level low ering as w ater exits the
basin.
If the pedicure spa is equipped w ith the optional Pow er Drain Pump ( PDP) feature, open the drain by
turning the drain handle in a clockw ise direction until it stops, and then press the button marked “ Drain”
on the front panel. The w ater level w ill low er as w ater is pumped out of the basin. Turn the pump off
by pressing the “Drain” button on the front panel once the basin is fully drained. (NOTE: The Power
Drain Pump will automati cally shut off after 2-1/2 minutes. We recommend turning off the pump
manually if all water has drained before automatic shut-off.)
Warning:
It is extremely important to follow the cleaning instructions located on the following page.
F ai l ur e t o cl ea n t h e p edi c ur e spa a d e qu a t el y ca n r esu lt i n ser i ou s h eal th i ssu e s f o r you r cl i en t s
as well as the nail technician. Faili ng to clean your pedicure spa may also cause the pedicure
spa to not work properly. Please consult your local and state codes concerning pedicure chair
cleaning for further requirements.

Document ID:06080001 Rev: E Technical Support: 800-626-6912 Page 20 of 24
Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting
Procedures
Please check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of
the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good
working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection.
To cleanthe pedicure spa, follow these easysteps:
After Each Pedicure:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position. Remove all debris.
2. Clean all the surfaces of the basin and all components. Use low-sudsing soap or detergent, and a non-
abrasive brush. Remove all visible residue from basin and then rinse with the sprayer.
3. Disinfect all surfaces and components with an EPA registered disinfectant in accordance with your state
board requirements. *EPA disinfectants require ten-minute contact.
4. Rinse off with clean water using the sprayer and wipe all parts dry with clean towel.
After Last Pedicure of the Day:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position. Remove all debris.
2. Remove the following:
a. Drain coveras shown on page 21.
b. Suction cover as shown on page 20.
c. Jets as shown on page 20.
3. Remove all debris then wash each component with low-sudsing soap, or detergent, using a soft brush.
Disinfect the components as well as the areas behind them with an EPA registered disinfectant. Follow
your state board requirements for disinfecting. Replace all components.
4. Clean all the surfaces of the basin using low–sudsing soap or detergent, and a non-abrasive brush.
Remove all visible residue from basin and then rinse with sprayer.
5. Fi ll basin with clean warm water to the fill line.
6. Pour into the basin three teaspoons of low-foaming dishwasher crystals (not gel) and 1 ounce of
household bleach forup to six gallons of water.
Follow your state board requirements as they may differ from the above step.
7. Turn on the whirlpool jets and let run for ten minutes.
8. Turn the jets off and drain water from the basin.
9. Rinse the basin and all other components with clean water using the sprayer.
10. Refill the basin with clean water. Turn the jets on and run for one minute.
11. Drain water from the basin and turn off the whirlpool jets. Then wipe dry with a clean towel.
12. Make a record of the date and time of this cleaning and disinfecting.
Once a Week Overnight Cleaning:
In addition to the daily cleaning, the following cleaning procedures must be done every week.
1. Follow steps one through seven as listed above as in “After Last Pedicure of the Day.”
2. Turn jets off after ten minutes and let solution sit over night in basin (six to ten hours).
3. The next morning drain, rinse, and wipe dry with a clean towel.
4. Make a record of the date and time of this cleaning and disinfecting.
CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use
ONLY non-abrasive products to clean the pedicure spa.
This manual suits for next models
1
Table of contents
Other European Touch Hot Tub manuals