European Touch Solace FORTE' User manual

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 1 of 24
FORTE’, ALTERA, and PRIMA
Solace Spas

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 2 of 24
EUROPEAN TOUCH - LIMITED WARRANTY
EUROPEAN TOUCH manufactures the Solace®Whirlpool Pedicure Spa with the highest standards for
quality materials and workmanship accordingly; EUROPEAN TOUCH expressly warrants their products
as follows:
To the original owner of the Solace®Whirlpool Pedicure Spa (herein called "pedicure spa"):
EUROPEAN TOUCH may repair or replace at its option, any pedicure spa found to be defective in
material or workmanship upon inspection by an authorized representative of EUROPEAN TOUCH. This
warranty covers the following components for the following time periods:
•Recirculating Pump: Two (2) years from date of shipment.
•All other components: One (1) year from date of shipment.
The exchange of a pedicure spa is limited to supplying a replacement pedicure spa of comparable
style and size. EUROPEAN TOUCH may, at its own discretion, use refurbished parts or pedicure
spas for replacement purposes. Owner must pay all labor and shipping charges necessary to
replace or repair the pedicure spa. NO CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WILL BE ALLOWED WHATSOEVER. This warranty is null and void if the pedicure spa is
removed from its place of initial installation, or is not installed in accordance with federal, state or local
codes and ordinances. Furthermore, this warranty does not apply if the pedicure spa has been subject to
misapplication, improper installation or maintenance, negligence, improper cleaning or other
circumstances beyond EUROPEAN TOUCH's control.
NOT COVERED
1) Damage to pump parts and/or motor parts due to obstruction in plumbing lines, etc.
2) Staining, fading or discoloration of plastic surfaces due to exposure and/or the use of harmful
cleaning agents or chemicals.
3) Staining, fading or discoloration caused by improper or poor water additives not related to
maintenance of proper water are not covered by this warranty.
4) Malfunctions or damage caused by improper installation; including not meeting local and state
plumbing, electrical, and building codes.
5) Staining, fading or discoloration of the vinyl seat, armrests or footrest.
6) Damage resulting from standing in the basin.
7) Freight damage, misuse, neglect, accident, natural disaster, and abuse.
8) Unauthorized repairs.
Should service be required for any reason of any defect or any malfunction during the warranty period,
please contact:
EUROPEAN TOUCH
Technical Support
8301 W. Parkland Court
Milwaukee, WI 53223
Phone Number: 414-357-7016
Toll Free: 1-800-626-6912
Fax: 414-357-6360
http://www.europeantouch.com
The owner agrees by using this pedicure spa that the obligation of EUROPEAN TOUCH shall not extend
to indirect or contingent damage, of injury, which may result from such use that the obligation of
EUROPEAN TOUCH are limited to those set forth herein, and other obligations, expressed or implied are
assumed by EUROPEAN TOUCH.
No dealer or other person has any authority to bind EUROPEAN TOUCH to changes or additions to this
warranty or its products. Accordingly, EUROPEAN TOUCH is not responsible for any such warranties or
representations.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 3 of 24
OWNERS MANUAL For
Solace®Whirlpool Pedicure Spa Models:
FORTE’, ALTERA, PRIMA
IMPORTANT INFORMATION
Serial Number:
W/O Number:
Installed by:
Installation Date:
Serial Number
W/O Number
Note: Vietnamese and Korean translations available upon request.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 4 of 24
Table of Contents
EUROPEAN TOUCH - LIMITED WARRANTY ......................................................................... 2
IMPORTANT INFORMATION ................................................................................................... 3
Introduction.............................................................................................................................. 5
Important Requirements ......................................................................................................... 5
Precautions ............................................................................................................................ 5
Health Risk Warning .............................................................................................................. 5
Installation Specifications Summary ..................................................................................... 6
Location and Support ............................................................................................................. 6
Important Installation and Utility Information ....................................................................... 7
Dimensional Drawings ............................................................................................................8
Crystal Clean™ Pipe-Free® and Traditional Whirlpool (With Jets)........................................... 8
Crystal Clean™Pipe-Free®..................................................................................................... 9
Traditional Whirlpool (With Jets) ............................................................................................. 10
Specifications ........................................................................................................................ 11
Attaching the Seat Back........................................................................................................ 12
Unpacking the Cushions....................................................................................................... 13
Remote Control Configurations ........................................................................................... 13
Attaching the Cushions ........................................................................................................ 14
Component Reference .......................................................................................................... 15
Pedicure Product Guidelines................................................................................................ 15
Crystal Clean™Pipe-Free®Spa - Operating Instructions ................................................... 16
Crystal Clean™Pipe-Free®Spa - Cleaning and Disinfecting Procedures ......................... 17
Traditional Whirlpool (With Jets) - Operating Instructions ................................................... 18
Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting Procedures ................. 19
Removal / Replacing Jet Parts............................................................................................. 20
Removal / Replacing Suction Cover .................................................................................... 20
Removing / Replacing Drain Handle .................................................................................... 21
Removing / Replacing Impeller ............................................................................................ 21
History and Notes.................................................................................................................. 22

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 5 of 24
Introduction
Thank you for selecting EUROPEAN TOUCH, the leading designer, manufacturer, and marketer of
pedicure spas in North America. The Solace®Forte’ and Solace®Altera pedicure spas (herein referred
to as pedicure spa) are innovative whirlpool pedicure spas that have been designed to serve you
dependably for many years. Please take time to thoroughly read this entire manual before installation
and use. If you have any problems or have questions regarding your pedicure spa, please contact
EUROPEAN TOUCH’s Technical Support Department at 1-800-626-6912, Monday through Friday 8
AM to 5 PM CST. After hours calls are recorded and attended to the next business day.
Important Requirements
EUROPEAN TOUCH requires that you contact a local, licensed plumber and licensed electrician to
install your new pedicure spa. Installation must be in compliance with all your local and state building
codes. Your pedicure spa cannot operate efficiently or safely unless it is provided with adequate
electrical power, sufficient water pressure, proper water temperature, and required drainage
capabilities. Contact your local building inspector for information and local code compliance
procedures that need to be followed when having your pedicure spa installed. Subsequent inspections
and approvals that may be required are the responsibility of the purchaser. (See limited warranty
regarding incidental or consequential exclusions – page 2).
Precautions
•Do not stand in the basin of the pedicure spa!
•Excessive water temperature is dangerous and should be checked before use.
Maximum operating water temperature should not exceed 105°F (41°C) and the
maximum supply water temperature should not exceed 150°F (65°C).
•Always enter and exit the pedicure spa slowly and carefully.
•Never bring or operate any electrical devices into or near the pedicure spa.
•This pedicure spa has a weight capacity of 250 pounds.
Health Risk Warning
Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use
the pedicure spa at any time. Nail technicians should advise clients to consult their physician
before using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or
persistent pain. In some cases diabetics may experience improved circulation in their feet, but
should first consult their physician prior to receiving a pedicure. If the client experiences any
pain or discomfort, immediately discontinue the use of the pedicure spa.
Your client’s massage and pedicure spa experience should be pleasant and comfortable.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 6 of 24
Installation Specifications Summary
Note: Failure to comply with federal, state or local codes and ordinances will result in the warranty
being null and void.
As stated, the pedicure spa installation must comply with all plumbing and electrical codes. A licensed
plumber and licensed electrician must complete the applicable connections of the pedicure spa.
Location and Support
Select a level location. The floor structure beneath the pedicure spa must be capable of supporting
the occupied pedicure spa.
For the seat back to fully recline, the pedicure spa base must be mounted a minimum distance from
the wall:
Forte’ model with full recline option 24” (61 cm)
Forte’ model 18” (46 cm)
Altera model 12” (31 cm)
Prima model 7” (18 cm)
= “X” dimension, below, by model.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 7 of 24
Important Installation and Utility Information
Electrical Service:
A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power to the
pedicure spa. (220V if ordered in 220V configuration)
Water Supply:
All plumbing connections must conform to local codes.
Normal water pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
The hot water supply temperature must not exceed 150°F (65°C). Adjust your hot water heater
accordingly.
For hot and cold water supply fittings and power drain fittings location, see figure 1 below.
Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with
ANSI/ASME A112.18.3M, A112.18.1M, and CSA B125
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems
in Plumbing Fixture Fittings) is applicable to plumbing fixture fittings with outlets not protected by an
air gap. Included in the possible range of applications are fittings with hose connected outlets, fittings
with pullout spout, hand held showers, shampoo fittings and deck-mounted fittings. ASME
A112.18.3M is now referenced in ASME A112.18.1M (Plumbing Fixture Fittings) and CSA B125.
Check valves are listed to both standards with the Canadian Standards Association, IAPMO and UL.
ANSI - American National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underwriters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided)
must be installed by a licensed plumber.
Pedicure spa must be securely fastened to the floor as shown in figure 2 below. Fasten the pedicure
spa to the floor with at least two fasteners, one in the middle plastic support and one in the rear
plastic support.
Back of Pedicure Spa Install Fasteners Here
Figure 1 Figure 2

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 8 of 24
Dimensional Drawings
Crystal Clean™ Pipe-Free® and
Traditional Whirlpool (With Jets)

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 9 of 24
Crystal Clean™Pipe-Free®

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 10 of 24
Traditional Whirlpool (With Jets)

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 11 of 24
Specifications
Hot and cold water supply lines required (hot and cold shut offs may be installed under pedicure spa
base) See pages seven through ten.
Drain installation: references noted on pages seven through ten, can be installed with
optional power drain pump or as gravity drain.
Overall dimensions without accessories, seat upright: 54"L (138cm) x 31"W (82cm) x 56"H
(143cm)*
Without accessories, seat collapsed: (shipping position): 54"L (138cm) x 32"W (82cm) x 36"H
(92cm)*
Shipping dimensions: 55"L (140cm) x 33"W (87cm) x 41"H (108cm)*
Empty weight: 150 Ibs (68kg)*
Shipping weight: 205 lbs (92kg)*
Capacity of basin: 5 U.S. Gallons = Traditional Whirlpool (with Jets)*
6.5 U.S. Gallons = Crystal Clean™Pipe-Free®*
Whirlpool pump motor: 1/6 HP, 110V, 60HZ (alternate voltages available) (3/4 HP for Traditional
Whirlpool - with Jets)
Forte’ seat and back motors: 30V DC Linear Actuators. Forte’ requires 18” (46 cm) of space between
pedicure spa and wall with standard actuator, and 24" (61 cm) with fully-
reclining actuator.*
Altera seat and back movement: 2 infinitely adjustable lockable gas cylinders for reclining/sliding.
The Altera requires 12" (31cm) of space between pedicure spa and wall
in order for seat to recline to its fullest extent.*
Massage motor: 12V AC, Adapter included (alternate voltages available)
Power source: 110V AC/ 5 Amp, 60 Hz (GFCI Protected)
Caution: Pedicure spa must be installed by a licensed electrician and a licensed
plumber, conforming to all local and national electrical codes.
Construction: Linear Low Density Polyethylene (LLDPE), self-contained, pre-plumbed
Crystal Clean™Pipe-Free®water massage system (pipe-free pedicure spas): 'underfoot' footplate
water massage grooves, no closed loop circulating pipes, 100% fully
drained, and cleanable
Hydro-Therapeutic (Jet System: Traditional Whirlpool pedicure spas): PVC, two (2) fully-
directional jets, built-in air control
Electrical switches: On/Off switch for whirlpool pump. Hand-held low voltage remote controls
for massage motors, heat and seat/back position hot and cold water
supply lines required
UL listed/CE certified: Complies with ASME/ANSI Whirlpool Bathtub Specs ASME/ANSI
A112.19 7M-1995 and A112.19.8M-1995. Backflow Protection Devices
for Faucets with Side Spray: Check valves comply with ANSI/ASME
A112.18.3M, A112.18.1M, and CSA B125.
Limited warranty: One (1) year from date of purchase.
Due to our policy of continuous improvements, all specifications are subject to change without notice.
*Note: All dimensions and weights are approximate

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 12 of 24
Attaching the Seat Back
Your pedicure spa shipped with the seat bottom and seat back already attached to the base. Follow
these instructions to connect the seat back to the pedicure spa:
Forte’ Altera and Prima
Step 1: Remove the hitch and clevis pins located
on the seat back mounting bracket on the back
of the chair.
Step 1: Remove the hitch and clevis pins
located on the seat back mounting bracket on
the back of the chair.
Step 2: Slide the seat bracket into the black end
on the linear actuator, and line up the holes.
Step 2: Line up the hole on the seat bracket with
the hole on the cylinder end.
For Prima, line up with second hole.
Step 3: Slide the clevis pin through the holes and
secure by inserting the hitch pin through the
small hole on the clevis pin.
Step 3: Slide the clevis pin through the holes
and secure by inserting the hitch pin through
the end hole on the clevis pin.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 13 of 24
Unpacking the Cushions
Your cushion set is packaged in its own box within the pedicure spa shipping carton. All needed parts
are located inside of this box. These include:
•(1) Seat Back
•(1) Seat Bottom
•(2) Arm Cushions
oAltera Vibration Massage Only: The remote and junction box
Please make sure that all parts are removed from the box before discarding the box. If any parts are
missing, the customer must contact EUROPEAN TOUCH within 30 days of the delivery date for
replacement at 800-626-6912.
Remote Control Configurations
Recline Seat Back:
Tilt Backward or
Forward.
Forte’
Seat Movement
Move Seat Bottom:
Slide
Forward or
Backward.
Indicates that
Vibrate Feature is
Activated.
Type of Vibrating
Massage: (Surge,
Steady, Pulse,
Wave).
Increase or
Decrease Intensity
of vibrating
massage.
Forte’/Altera
Roller
Timer (15 min or 30
min).
Indicates that Roller
Feature is
Activated.
Area of Vibration:
Zone 1 = Upper.
Zone 2 = Lower.
Increase or
Decrease Speed
of vibrating
massage.
Numerical Display
shows intensity
levels.
LEDs show type of
FULL-BODY
Massage.
Select from 5 types of
FULL-BODY
Massages as
indicated by LEDs
above.
Adjust intensities Up
or Down.
Power On/Off:
automatically selects
15 min timer.
Holding switch for
over 3 seconds
activates 30 min
timer as indicated by
LED above.
Forte’
Vibration
Numerical Display
indicates ten levels
of wave speed.
LED shows selected
Timer.
LED shows selected
Heat setting.
Select from 5 types of
BACK Massages as
indicated by LEDs
above.
Adjust Wave Speed
Up or Down.
Select Hi or Lo Heat
as shown by LEDs
above.
Activates the Massage
Zone 1.
Power On/Off.
Activates Massage
Wave.
Adjusts Intensity Up or
Down.
Adjusts Speed Up or
Down.
Altera
Vibration
LED Shows Massage
Zone Activated.
LED Shows Selected
Massage Time.
Activates the Massage
Zone 2.
Timer Selects (Indicated
in LEDs Above).
Sets Massage on
Steady.
Adjusts Sensate Up or
Down.
Moving Display indicates
speed and pattern of Back
Massage.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 14 of 24
Attaching the Cushions
All pedicure spa cushions attach to the pedicure spa with Velcro. The Forte' and Altera Pedicure spas
have cables for the cushions that need to be routed properly. Follow these instructions for attaching
the cushions properly to your pedicure spa:
Use the following instructions for all cushion models:
Step 1: Your pedicure spa will
come with the Velcro already in
place for the seat bottom and
the seat back.
Step 4: Remove the protective film
from the Velcro on the bottom
of the arm pads. Carefully
place the arm pads on the chair
arms and slide the remotes
under the remote holders on
the arm pads.
Step 7: ALTERA VIBRATION
ONLY – The Altera cushion
remote control comes attached
to the junction box.
Step 2: Attach the seat bottom to
the chair bottom. Make sure
that the cushion is centered on
the chair bottom. The arms
should be able to close without
cushion interference.
Step 5: FORTE' ONLY – The
remote control and power
supply cord are taped together
behind the chair. Remove the
tape and connect the cords
from the cushion to these
connectors.
Step 8: ALTERA VIBRATION
ONLY – The Altera junction
box should be mounted on the
back of the seat back. Plug
the 2 cushion cords into the
red and white receptacles
(they can go into either
receptacle). The power supply
cord plugs into the receptacle
next to the remote cord. Plug
the power supply into the
power strip.
Step 3: Route the seat back
cushion cables underneath the
chair back and out the back.
Center the seatback cushion on
the chair back.
Step 6: FORTE' ONLY – Route
the seat back cables through
the hole in the pedicure spa
base.
Step 9: The remotes can be
slipped into the armrests as
shown.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 15 of 24
Component Reference
Crystal Clean™Pipe-Free®
Inside Basin View
Crystal Clean™Pipe-Free®
Front View
Traditional Whirlpool (with Jets)
Inside Basin View
Traditional Whirlpool (with Jets)
Front View
Pedicure Product Guidelines
Because there are so many different products on the market, it is difficult for us to list all of the pedicure
products that are safe to use in our pedicure spas. However, the following guidelines can be used:
•It is your responsibility to understand and follow your state’s regulations regarding product
usage and disinfecting requirements.
•Do not use any products containing a foaming agent; this will cause excessive foam.
•It has been determined that products containing non-dissolving abrasives (such as sand and
sea salts) will not harm the internal component structure of your pedicure spa as long as the
entire EUROPEAN TOUCH cleaning requirements are followed without deviation.
•Oil based products may be used in your pedicure spa as long as the cleaning requirements are
met.
•Please use pedicure products and cleaning solutions in accordance with each manufacturer's
directions.
EUROPEAN TOUCH whirlpool pedicure spas will give you many years of service as long as proper
precautions and precise cleaning and operating instructions are followed. It is the responsibility of the
pedicure spa owner to properly clean the pedicure spa.
If you are experiencing problems cleaning your pedicure spa, please contact the manufacturer of your
pedicure products or EUROPEAN TOUCH Technical Support at 800-626-6912.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 16 of 24
Crystal Clean™Pipe-Free®Spa - Operating Instructions
Preparing the Pedicure Spa for Operation:
After the pedicure spa is installed and the plumbing and electrical connections are made, clean and
disinfect the basin before initial use. Rinse the basin by using the attached water sprayer. Wipe the
basin dry with a clean towel.
To Operate the Pedicure Spa, Follow These Easy Steps:
Adding Water to the Pedicure Spa Basin:
1. Close the drain by turning the chrome drain handle counter-clockwise until it stops.
2. Add water to the basin by lifting upward on the water faucet fill handle. Turn the handle in a
counter-clockwise direction for cold water or clockwise for warm water as indicated by the red
(hot) and blue (cold) markings around the handle (CAUTION: hot water can burn skin). Continue
to add water until the fill line is reached. The fill line is indicated by the wavy (~~~~) line in the
basin.
3. Turn the off water by pushing the handle downward and center.
Operating the Crystal Clean™Pipe-Free®System:
The Crystal Clean™Pipe-Free®System eliminates pipes and jets that can harbor harmful bacteria
while at the same time delivering a soothing, quality foot massage. This unique system is driven by
an impeller that pulls water through the inlet cover and then forces the water outward through key
massage zones in the footplate. The end result is a soothing massage delivered to all areas of the
foot: front, back and bottom.
To start or stop the whirlpool, depress the On/Off button labeled “Jets” (NOTE: An indicator light on
the “Jets” button flashes when the footplate is improperly installed, or the basin contains no
water. As a result, the whirlpool will not function. To fix, simply check that the footplate is
securely fastened or add water to the basin).
Removing Water from the Pedicure Spa Basin:
First, make certain the whirlpool jets are turned off by turning the On/Off switch counter-clockwise to
the “Off” position.
If the pedicure spa is hooked up directly to a floor drain, simply open the drain by turning the drain
handle in a clockwise direction until it stops. You should see the water level lowering as water exits
the basin.
If the pedicure spa is equipped with the optional Power Drain Pump (PDP) feature, open the drain by
turning the drain handle in a clockwise direction until it stops. Press the button marked “Drain” on the
front panel. The water level will lower as water is pumped out of the basin. Turn the pump off by
pressing the “Drain” button on the front panel once the basin is fully drained (NOTE: the PDP will
automatically shut off after 2-1/2 minutes. We recommend turning off the pump manually if all
water has drained before automatic shut-off).
Warning:
It is extremely important to follow the cleaning instructions located on the following page.
Failure to clean the pedicure spa adequately can result in serious health issues for your
clients as well as the nail technician. Failing to clean your pedicure spa may also cause the
pedicure spa to not work properly. Please consult your local and state codes concerning
pedicure chair cleaning for further requirements.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 17 of 24
Crystal Clean™Pipe-Free®Spa - Cleaning and Disinfecting
Procedures
Please check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure
of the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in
good working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause
infection.
To clean the pedicure spa, follow these easy steps:
After Each Pedicure:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Loosen the footplate by turning the footplate Tee Knobs in a counter-clockwise direction. Remove the
footplate from the basin by lifting upward on the inlet cover. (NOTE: Gently press down on the
footplate center when loosening the footplate Tee Knobs, as this will relieve pressure and help
loosen the Tee Knobs.)
3. Remove all debris from the basin.
4. Clean all the surfaces of the basin and all components, as well as the top and bottom of the footplate and
both Tee Knobs. Use low-sudsing soap or detergent and a non-abrasive brush. Remove all visible
residue from the inside of the basin and all other components. Clean off sensor on bottom of basin.
5. Rinse the basin with clean water using the sprayer.
6. Disinfect all components, surfaces, basin, top and bottom of footplate, and footplate Tee Knobs with an
EPA-registered disinfectant, in accordance with your state board requirements. *EPA disinfectants
require ten-minute contact.
7. Rinse the basin again with clean water using the sprayer.
8. Thoroughly dry the basin and all other components with a clean towel.
9. Replace the footplate and secure by simultaneously turning both footplate Tee Knobs in a clockwise
direction. (NOTE: When replacing the footplate, carefully align the mounting studs with the
mounting holes. Tighten each knob until snug. Be careful not to over-tighten, as this can damage
the Tee Knobs.)
After Last Pedicure of the Day:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Remove the drain cover as shown on page 21. Remove the impeller as shown on page 21. Remove all
debris. Then wash with low-sudsing soap or detergent using a soft brush. Disinfect the impeller and
drain cover as well as the area behind the drain cover. Replace drain cover and impeller.
3. Next repeat steps two through seven above as in “After Each Pedicure.”
4. After all components are put back into place, fill basin with clean warm water to the fill line.
5. Pour three teaspoons of low-foaming dishwasher crystals, (not gel) and 1 ounce of household bleach for
up to six gallons of water.
Follow your state board requirements as they may differ from the above step.
6. Turn on the whirlpool and let run for ten minutes.
7. Turn the whirlpool off and drain water from the basin.
8. Using the sprayer, rinse off all components, surfaces, and basin.
9. Refill the basin with clean water and turn the whirlpool on. Run for one minute to rinse.
10. Drain water from the basin and turn off the whirlpool.
11. Wipe dry with clean towel.
12. Make a record of the date and time of this cleaning and disinfecting.
Once a Week Overnight Cleaning:
In addition to the daily cleaning, the following cleaning procedures must be done every week:
1. Follow steps one through five above, as in “After the Last Pedicure of the Day.”
2. Turn on the whirlpool and let run for ten minutes.
3. Turn the whirlpool off and let the water sit overnight in the basin (six to ten hours).
4. In the morning, run the whirlpool for five minutes and drain the basin.
5. Rinse the basin with clean water using the sprayer and dry with a clean towel.
6. Make a record of the date and time of this cleaning and disinfecting.
CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use
ONLY non-abrasive products to clean the pedicure spa.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 18 of 24
Traditional Whirlpool (With Jets) -Operating Instructions
After the pedicure spa is installed and the plumbing and electrical connections are made, clean and
disinfect the basin before initial use. Rinse the basin by using the attached water sprayer. Wipe the
basin dry with a clean towel.
To Operate the Pedicure Spa, Follow These Easy Steps:
Adding Water to the Pedicure Spa Basin:
1. Close the drain by turning the chrome drain handle counter-clockwise until it stops.
2. Add water to the basin by lifting upward on the water faucet fill handle. Turn the handle in a
counter-clockwise direction for cold water or clockwise for warm water as indicated by the red
(hot) and blue (cold) markings around the handle (CAUTION: hot water can burn skin). Continue
to add water until the fill line is reached. The fill line is indicated by the wavy (~~~~) line in the
basin.
3. Turn the off water by pushing the handle downward and center.
Operating the Water Jets:
Each pedicure spa is equipped with two fully adjustable jets that create a soothing foot massage. To
operate, turn the whirlpool jets on by turning the On/Off Switch in a clockwise direction. To increase
jet strength, open each jet by simply rotating the adjustment cover in a counter-clockwise direction.
To decrease water pressure, close each jet by rotating the adjustment cover in a clockwise direction
(NOTE: The Jet heads should not be positioned directly at the suction cover. Doing so will
create a noisy “gurgling” sound as air is being forced directly into water pipes). Turn off the
whirlpool jets by turning the On/Off switch counter-clockwise to its original starting position.
Removing Water from the Pedicure Spa Basin:
First, make certain the whirlpool jets are off by turning the On/Off Switch counter-clockwise to the
“Off” position.
If the pedicure spa is hooked up directly to a floor drain, simply open the drain by turning the drain
handle in a clockwise direction until it stops. You should see the water level lowering as water exits
the basin.
If the pedicure spa is equipped with the optional Power Drain Pump (PDP) feature, open the drain by
turning the drain handle in a clockwise direction until it stops, and then press the button marked
“Drain” on the front panel. The water level will lower as water is pumped out of the basin. Turn the
pump off by pressing the “Drain” button on the front panel once the basin is fully drained. (NOTE:
The Power Drain Pump will automatically shut off after 2-1/2 minutes. We recommend turning
off the pump manually if all water has drained before automatic shut-off.)
Warning:
It is extremely important to follow the cleaning instructions located on the following page.
Failure to clean the pedicure spa adequately can result in serious health issues for your
clients as well as the nail technician. Failing to clean your pedicure spa may also cause the
pedicure spa to not work properly. Please consult your local and state codes concerning
pedicure chair cleaning for further requirements.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 19 of 24
Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting
Procedures
Please check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure
of the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in
good working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause
infection.
To clean the pedicure spa, follow these easy steps:
After Each Pedicure:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position. Remove all debris.
2. Clean all the surfaces of the basin and all components. Use low-sudsing soap or detergent, and a non-
abrasive brush. Remove all visible residue from basin and then rinse with the sprayer.
3. Disinfect all surfaces and components with an EPA registered disinfectant in accordance with your state
board requirements. *EPA disinfectants require ten-minute contact.
4. Rinse off with clean water using the sprayer and wipe all parts dry with clean towel.
After Last Pedicure of the Day:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position. Remove all debris.
2. Remove the following:
a. Drain cover as shown on page 21.
b. Suction cover as shown on page 20.
c. Jets as shown on page 20.
3. Remove all debris then wash each component with low-sudsing soap, or detergent, using a soft brush.
Disinfect the components as well as the areas behind them with an EPA registered disinfectant. Follow
your state board requirements for disinfecting. Replace all components.
4. Clean all the surfaces of the basin using low–sudsing soap or detergent, and a non-abrasive brush.
Remove all visible residue from basin and then rinse with sprayer.
5. Fill basin with clean warm water to the fill line.
6. Pour into the basin three teaspoons of low-foaming dishwasher crystals (not gel) and 1 ounce of
household bleach for up to six gallons of water.
Follow your state board requirements as they may differ from the above step.
7. Turn on the whirlpool jets and let run for ten minutes.
8. Turn the jets off and drain water from the basin.
9. Rinse the basin and all other components with clean water using the sprayer.
10. Refill the basin with clean water. Turn the jets on and run for one minute.
11. Drain water from the basin and turn off the whirlpool jets. Then wipe dry with a clean towel.
12. Make a record of the date and time of this cleaning and disinfecting.
Once a Week Overnight Cleaning:
In addition to the daily cleaning, the following cleaning procedures must be done every week.
1. Follow steps one through seven as listed above as in “After Last Pedicure of the Day.”
2. Turn jets off after ten minutes and let solution sit over night in basin (six to ten hours).
3. The next morning drain, rinse, and wipe dry with a clean towel.
4. Make a record of the date and time of this cleaning and disinfecting.
CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use
ONLY non-abrasive products to clean the pedicure spa.

Document ID:06080001 Rev: B Technical Support: 800-626-6912 Page 20 of 24
Removal / Replacing Jet Parts
Tools required:
Pliers
7/8" deep well socket with extension
Check your state and local regulations for cleaning procedures. Links to your state boards can be
found on our web site, at www.europeantouch.com. Refer to the cleaning procedure page headed
“Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting Procedures,” page 19, for cleaning
recommendations.
Follow the steps below for cleaning and replacing parts:
Step 1: Remove the jet eyeball using the pliers. Pull
forward with a quick tug.
Step 3: Remove the jet nozzle and nut using a 7/8"
deep-well socket and extension.
Step 2: Remove the adjusting cover. This should pull
out.
Step 4: For cleaning, refer to “Traditional Whirlpool
(With Jets) - Spa Cleaning and Disinfecting
Procedures” on page 19. Reassemble the jet
assembly. The jet nozzle nut should be hand
tightened using the socket with extension. If the
adjustment cover is hard to turn, slightly loosen the
jet nozzle nut.
Step 5: Reverse steps to reassemble.
Removal / Replacing Suction Cover
Tools required:
Philips head screwdriver
Check your state and local regulations for cleaning procedures. Links to your state boards can be
found on our web site, at www.europeantouch.com. Refer to the cleaning procedure page headed
“Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting Procedures,” page 19, for cleaning
recommendations.
Follow the steps below for cleaning and replacing parts:
Step 1: Unscrew Phillips head screw, located in the
center of suction cover, turning counter clockwise.
Step 2: Pull cover forward to remove.
Step 3: For cleaning, refer to “Traditional Whirlpool (With Jets) - Spa Cleaning and Disinfecting Procedures” on
page 19.
Step 4: Put cover back on and replace Phillips head screw turning clockwise.
Caution: Do not over tighten screw.
Clean this area, using low
foaming soap and
disinfectant, with a brush.
Remove all visible
residue and rinse with
clean water.
Clean this area, using
low foaming soap and
disinfectant, with a
brush. Remove all
visible residue and
rinse with clean water.
This manual suits for next models
2
Table of contents
Other European Touch Hot Tub manuals
Popular Hot Tub manuals by other brands

Spa Guts
Spa Guts 6200Y Series Owner's operation guide

American Spas
American Spas AM745L-W owner's manual

Jacuzzi
Jacuzzi J-ALLURE J-ALLURELuxury Bathing and Entertainment... Installation and operation instructions

HotSpring
HotSpring Landmark owner's manual

SpaEquip
SpaEquip LE04 user manual

JNJ SPAS