3 Ordering Code
Model
number Function Display
colour Supply
voltage Module 1 Module 2 Module 3 Relay
Output 1 Comms
Module PDS
Module Manual
2408iAL
SOFTWARE CONFIGURATION Configuration of 2nd analogue input requires D5 in module 3
Sensor Input Setpoint
min Setpoint
max Display
Units Digital
input 1 Digital
input 2 2nd DC
Input PV Function 2nd Input
Display Min 2nd Input
Display Max Configurat-
ion option
Note 6 Note 6 Note 7 Note 8 Note 8
Note 1: By default, alarm 1 will be
assigned to relay output 1 and
alarms 2, 3 and 4 will be assigned to
Modules 1, 2 and 3 respectively.
Note 2: The allocation of alarms to
the dual relay outputs must be
performed in configuration by the
customer.
Note 3: Triple contact or logic inputs
can be configured, by the user, for
any of the functions listed under
Digital Inputs 1 and 2.
Note 4: The triple logic output can
configured as alarm outputs or as
telemetry outputs via digital
communications.
Relay Output 1
XX Not fitted
RF Fitted unconfigured
OR Select alarm configuration
from table A
Modules 1, 2 and 3
XX Module not fitted
Alarm Relay output (change-over)
R4 Module fitted unconfigured
OR Select alarm configuration from table A.
DC retransmission
D6 Module fitted unconfigured
First character
V- Process Value retransmission
S- Setpoint retransmisssion
Z- Error retransmission
Second character
-1 0-20mA
-2 4-20mA
-3 0-5Vdc
-4 1-5Vdc
-5 0-10Vdc
Dual relay (Note 2)
RR Module fitted unconfigured
Triple contact input (Note 3)
TK Module fitted unconfigured
Triple logic input (Note 3)
TL Module fitted unconfigured
Triple logic output (Note 4)
TP Module fitted unconfigured
20mA Transmitter supply
MS 24Vdc, 20mA supply
Strain Gauge Transducer supply (modules 1
& 2 only) (note 5)
G3 5V transducer supply
G5 10v transducer supply
2nd analogue input (module 3 only)
D5 Module fitted unconfigured
For configuration, see PV Function field
Display colour
GN Green display
RD Red display
Supply voltage
VH 85-264Vac
VL 20-29Vac/dc
10
Table A:
Alarm relay configuration
(See note 1)
Non-latched alarms
FH High alarm
FL Low alarm
DB Deviation band alarm
DL Deviation low alarm
DH Deviation high alarm
RA Rate-of -change alarm
Latched alarms
HA High alarm
LA Low alarm
BD Deviation band alarm
WD Deviation low alarm
AD Deviation high alarm
RT Rate-of -change alarm
NW New alarm Manual
XXX None
ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA Italian
Comms module
XX Module not fitted
RS232 Module
A2 Module fitted unconfigured
AM Modbus protocol
AE EI-Bisynch protocol
RS485 (2-wire) Module
Y2 Module fitted unconfigured
YM Modbus protocol
YE EI-Bisynch protocol
RS485 (4-wire) (= RS422) Module
F2 Module fitted unconfigured
FM Modbus protocol
FE EI-Bisynch protocol
Profibus Module
PB High speed RS485
PDS module
XX Module not fitted
M6 Module fitted unconfigured
RS Remote setpoint input
Note 5: By default, the transducer
supply for input 1 will be installed
in module position 2 and the
transducer supply for input 2 in
module position 1.
Function
AL Indicator/Alarm unit
AP Profibus Indicator
Note 6: Setpoint min and max: Include the decimal points required in the displayed value; up to one for temperature, up to two for process inputs.
Note 7: Select the code required from the Sensor Input table
Note 8: These two fields are used to scale the 2nd DC input if it is a linear process input, otherwise it should be left blank.
Note 9: For mA inputs, a 1% 2.49Ωcurrent sense resistor is supplied. If greater accuracy is required, a 0.1% resistor can be ordered as Part number SUB2K/249R.1
Sensor input & 2nd DC input Setpoint min & max
°C°F
Thermocouples Min Max Min Max
J Type J -210 1200 -340 2192
K Type K -200 1372 -325 2500
T Type T -200 400 -325 750
L Type L -200 900 -325 1650
N Type N -250 1300 -418 2370
R Type R -50 1768 -58 3200
S Type S -50 1768 -58 3200
B Type B 0 1820 32 3308
P Platinell II 0 1369 32 2496
Z Pt100 -200 850 -325 1562
Process inputs (Scaled to setpoints max & min) Range Min Range Max
F -100 to +100mV -9999 99999
Y 0 to 20mA (note 2) -9999 99999
A 4 to 20mA (note 2) -9999 99999
W 0 to 5Vdc -9999 99999
G 1 to 5Vdc -9999 99999
V 0 to 10Vdc -9999 99999
Factory downloaded input
CType C -W5%Re/W26%Re
(default downloaded input) “Table Reference
Number”
6
0 to 2319 32 to 4200
D Type D - W3%Re/W25%Re “T035” 0 to 2399 32 to 4350
E E thermocouple “T012” -270 to 999 -450 to 1830
1 Ni/Ni18%Mo “T033” 0 to 1399 32 to 2550
2 Pt20%Rh/Pt40%Rh “T025” 0 to 1870 32 to 3398
3 W/W26%Re (Engelhard) “T09” 0 to 2000 32 to 3632
4 W/W26%Re (Hoskins) “T029” 0 to 2010 32 to 3650
5 W5%Re/W26%Re (Engelhard) “T011” 10 to 2300 50 to 4172
6W5%Re/W26%Re
(Bucose) “T038” 0 to 2000 32 to 3632
7 Pt10%Rh/Pt40%/Rh “T023” 200 to 1800 392 to 3272
8Exergen K80 I.R. Pyrometer “
5
”-45 to 650 -49 to 1202
Digital inputs 1 & 2
XX Disabled
AC Alarm acknowledge
KL Keylock
SR Remote setpoint select
PV Select process value input 2
M5 CTX mode 5 (digital input 2
only). For use with PDTCX
‘smart’ current transformer.
J1 Initiate tare correction on strain
gauge input 1
J2 Initiate tare correction on strain
gauge input 2
J3 Initiate automatic calibration of
strain gauge input 1
J4 Initiate automatic calibration of
strain gauge input 2
PV function
XX Input 1 displayed
LO PV = the lowest of i/p 1 and 2
HI PV = the highest of i/p 1 and 2
FN PV derived from i/p 1 and 2
RS Remote setpoint
Display Units
CoC K pK
FoFX Blank
Configuration Option
XX Standard
SG Load cell/strain gauge
CL pressure transducer