01. PRODUCT SAFETY…………………..……………………………………………………………………………………………………p.3
01.1 SAFETY WARNINGS……………………………………………………………………………………………………………….. p.3
01.2 GENERAL SAFETY PRECAUTIONS…………………..…………………………………………………………………………..p.4
02. PRODUCT DESCRIPTION……………………………………………………………………………………………………………….. p.5
02.1 DESCRIPTION OF THE COMPONENTS………………………………………………………………………………………….p.7
03. PRODUCTION INSTALLATION….……………………………………………………………………………………………………… p.9
03.1 INTRODUCTION……………………………………………………………………………………………………………………...p.9
03.2 FLUE PIPE…………………..……………………………………………………………………………………………………….. p.10
03.3 CHIMNEY…………………..…………………………………………………………………………………………………………. p.11
03.4 DRAUGHT…………………..…………………………………………………………………………………………….………….. p.12
03.5 STOVE EFFICIENCY…………………..……………………………………………………………………………………………. p.13
03.6 INSTALLATION…………………..……………………………………………………………………………..…………………… p.13
04. USING THE PRODUCT…………………………………………………………………………………………………………………… p.17
04.1 DISPLAY ………………………………………………………………………………………………………………………………p.17
04.2 IGNITION …………………………………………………………………………………………………….………………………..p.18
04.3 COMBUSTION………………………………………………………………………….……………………………………………. p.19
04.4 PRODUCTION OF DHW PLUS…………………..…………………………………………………………….………………….. p.19
04.5 ICE ANTI-BLOCK FUNCTION…………………..……………………..………………………….……………..………………… p.20
04.6 AUTOMATIC FILLING VALVE…………………..………………………………………………………………..…………………p.20
05. CLEANING AND MAINTENANCE………………………………………………………………………………………………………. p.20
05.1 INTRODUCTION…………………………………………………………………………………………………………………….. p.20
05.2 DAILY CLEANING……………………………………………………………………………………………………...……………. p.20
05.3 MANUFACTURER'S RESPONSIBILITIES………………………………………………………………………………………...p.20
06. TROUBLE-SHOOTING……………………………………………………………………………….……………….….………………. p.20
07. CERTIFICATE OF INSTALLATION AND TESTING…………………………………………………………….….………………….p.21
08. YEARLY SCHEDULED MAINTENANCE………………………………………………………..………………………………………p.22
09. WARRANTY CERTIFICATE…………………………………………………………………………………………….……………….. p.23

01. PRODUCT SAFETY
01.1 SAFETY WARNINGS
The stoves were built in compliance according to standard EN13240 (wood stoves), EN 14785 (pellet stoves) and EN 12815 (kitchens and wood-burning
stoves)using high quality and non-polluting materials. To make better use of your stove it is advisable to follow the instructions in this booklet.
Read this manual carefully before use or any maintenance operation.
Eva Stampaggi aims to provide as much information as possible to ensure safer use and to avoid damage to persons, property or parts of the stove itself.
Each stove is subjected to internal testing before shipment and as such residues inside the appliance may be found.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
FOR ANY REQUIREMENT OR CLARIFICATION PLEASE CONTACT
THE AUTHORISED DEALER
•Installation and connection must be carried out by qualified staff in compliance with local regulations, national and European standards (UNI 10683 in
Italy) and with the annexed installation instructions. Furthermore, these operations must be performed by personnel who are authorised and professionally
trained for the task in question.
•The combustion of waste, especially of plastic materials, damages the stove and the flue pipe. Moreover, it is forbidden by the law against the emission
of harmful substances.
•Do not use alcohol, petrol or other highly inflammable liquids to light the fire or poke it during operation.
•Do not introduce into the stove an amount of fuel greater than that recommended in this booklet.
•Do not modify the product.
•It is forbidden to use the appliance with the door open or the glass broken.
•Do not use the appliance as, for example, a clothes drying rack, a bearing surface or step etc.
•Do not install the stove in bedrooms or bathrooms if not certified as watertight.
The wood to be used is as follows:
The wood log should have maximum 330mm in length and a maximum moisture content of 8%;
Dry wood produces more usable heat than wet wood as it produces less smoke, less soot and less carbon dioxide. Dry wood is the correct choice that allows you
to get the most out of your stove. Always remember to split the firewood to make it dry quicker: the higher its moisture content, the greater the amount of heat
necessary for it to ignite - heat subtracted from your well-being.
Based on the weight in kg of a cubic metre of material, the wood can be classified into “softwood” and “hardwood”.
"Softwood" (300-350 kg/m3 such as spruce, pine, poplar, alder, chestnut, willow) burns rapidly, producing a stronger heat; therefore, it is great for starting a fire but
to use it as fuel would require frequent refilling of the stove. “Softwood” can also produce more creosote, meaning that the chimney will require more frequent
cleaning.
“Hardwood” instead (350- 400 kg/m3 such as elm, oak, beech, ash) burns at a slower rate, resulting in sustained heat output and making this type of wood ideal
for domestic heating.
In terms of heating output, firewood can be divided into:
• Excellent quality: oak, ash, beech, maple.
• Fair quality: chestnut, birch and alder
• Acceptable quantity: lime, poplar and willow
THE CALORIFIC VALUE:
The calorific value depends therefore, on the density of the wood (that varies based on its type) and on its moisture content. The heat output of the stoves is directly
affected by this factors. Depending on its moisture content, it can be indicated in:
% of humidity
Calorific heat output kcal/kg
15%
3490
20%
3250
25%
3010
30%
2780
35%
2450
40%
2300
On average, a well seasoned wood has a calorific value of 3200 kcal/kg.
Eva Stampaggi S.r.l. declines any criminal and/or third party liability for any damage to persons or property arising from the failure to comply with the points
mentioned in this manual and from non-compliant product installation.
3

01.2 GENERAL SAFETY PRECAUTIONS
•Use the stove only as described in this manual. Any other use not recommended by the manufacturer may cause fires or accidents to people.
•Make sure that the electrical power available corresponds to the value indicated on the data plate (230V~/50Hz).
•This appliance is not a toy. Make sure children are not left unattended and do not use the appliance as a toy.
•This device is not intended for use by persons (including children) with reduced physical or mental capacity, or without specific experience and knowledge,
unless supervised or duly instructed on the use of the appliance by a person responsible for their safety.
•Disconnect the appliance from the mains when not in use or during cleaning operations.
•Never block the combustion air inlets and fume outlets.
•Since the stove is fitted with electrical components, do no touch it with wet hands
•Do not use the appliance in case of damaged cables or plugs. The device is classified as type Y: the power supply cable may only be replaced
by a qualified technician. Should the power supply cable be damaged, it can be replaced only by the manufacturer or by its technical assistance
service or by a similarly qualified person.
•
CAUTION! DO NOT TOUCH the FIRE DOOR, the GLASS, the HANDLE OR THE FUME OUTLET PIPE DURING OPERATION if not wearing
adequate protective devices as they become extremely hot!
•Keep inflammable materials, such as furniture, cushions, pillows, blankets, paper, clothing, curtains, etc., at least 1.5m away from the stove front and
30cm from the stove sides and back.
•Do not use the stove in dusty environments or wherever inflammable gases are generated (e.g. in a workshop or garage).
•The stove that is covered by or in direct contact with flammable materials, including curtains, blankets, etc., during normal operation may result in a fire
hazard. KEEP THE APPLIANCE AWAY FROM THE MATERIALS MENTIONED ABOVE.
•Do not immerse the cable, plug or any other appliance component in water or other liquids.
•Do not use the stove in dusty environments or wherever inflammable gases are generated (e.g. in a workshop or garage).
•The stove is fitted with components that generate arcs and sparks. Do not install the stove in areas posing a significant fire or explosion hazard due to a
high chemical substance concentration or to a high humidity level.
•Do not use the appliance close to bathtubs, showers, basins, sinks or swimming pools.
•Do not install the appliance underneath an air vent. Do not install the stove outdoors.
•Do not repair, disassemble or modify the appliance. The appliance is not fitted with components that can be repaired by users.
•Turn off the stove, disconnect it from the mains and wait until it has cooled down completely before performing any maintenance operations.
•WARNING: DISCONNECT THE STOVE FROM THE MAINS BEFORE PERFORMING ANY MAINTENANCE.
•CAUTION! This stove works exclusively with wood; DO NOT USE FUELS OTHER THAN WOOD: any other material will be burned. It will cause
failure and malfunction of the appliance.
•Store the wood in a cool and dry place: storage in overly cold or humid places can result in a reduction in the heat output of the stove.
•Clean the firebox regularly each time it is used.
•Open the firebox only upon refuelling or removal of residues to prevent fumes from escaping.
•Do not use the appliance as waste incinerator or for any other purpose other than the intended one.
•Do not use liquid fuels.
•Do not modify the appliance without prior authorisation.
•Use only original spare parts recommended by the manufacturer.
•The wood log should have maximum 330mm in length and a maximum moisture content of 8%;
•Make sure that the stove is transported in compliance with safety regulations. Avoid any improper transfers or knocks that may damage the tiles, stone
finishes or the structure.
•The metal structure is coated using high temperature paints. When using the appliance for the first few times, unpleasant odours may be given off due
to the paint of the metal parts that is drying: this is in no way dangerous and in such case, simply ventilate the premises. After the first heating cycles,
the paint will reach its maximum adhesion and all its chemical and physical features.
•CAUTION! Being a heating appliance, some parts of the stove can become extremely hot. For precisely this reason, we advise that you take
extreme care during operation.
WHEN THE STOVE IS WORKING:
•do not open the door;
•do not touch the door glass since it becomes extremely hot;
•keep children away from it;
•do not touch the fume outlet;
•do not pour any liquid inside the firebox;
•do not perform any maintenance operations if the stove is not cold;
•only qualified technicians are allowed to perform any operation;
•follow all the instructions contained herein.
4

02. PRODUCT DESCRIPTION
Cooking stove TL4S
Completely made of steel, they consist of a boiler casing equipped with water gap that surrounds the firebox on a side and communicates with the built-in expansion
tank which allows for the heating up of the water inside the heating system by means of a stainless steel coil heat exchanger. The stove can be equipped with a
second exchanger for production of domestic hot water.
All these are extra options to the traditional function of the stove, which comes with an upper plate and some models even with oven, allowing you to cook your
favourite meal in an effortless economical manner.
The advantages are many:
• can be used on their own or combined with a boiler
• equipped with programmable electronic control unit for safe operation
• easy to clean thanks to easy disassembly of the upper plate
We paid particular attention to the safety features during design and testing phases and therefore, all of our stoves come with:
• water level control system with automatic reset function
• boiler casing able to operate even in absence of pressure
• heat dissipation devices
• backup water reservoir for quick achievement of the required operating conditions
TECHNICAL DRAWING
TL4S
A= Ø 150 mm Scarico Fumi / Flue / Cheminée / Rauchbzug / Evacuación de humos / Descarga de fumos
TECHNICAL DATA
Technical data of the appliance:
Dati tecnici dell’apparecchio:
TL4S
Name:
Designazione:
Nominal heat output
Potenza termica nominale
Fuel throughput
Consumo orario (kg/h)
4.3
Minimum flue draught requirements
Requisiti minimi del tiraggio del camino (Pa)
12
Flue gas temperature
Temperatura fumi (°C)
179.6
Flue gas temperature at flue spigot or socket
Temperatura uscita fumi (°C)
186.1
Flue gas mass flow
Flusso massico dei fumi (g/s)
15.3
Efficiency
Rendimento (%)
85.3
Total heat output
Potenza termica (Kw)
15.8
Water heat output
Potenza termica resa all’acqua (Kw)
10.5
Space heat output
Potenza termica resa all’ambiente (Kw)
5.3
CO emission at 13% of O
2
Emissioni di CO al 13% di O2 (%)
0.0692
Maximum water operating pressure
Massima pressione di esercizio dell’acqua (bar)
-----
Discharge control operating temperature
Temperatura di intervento termostato sicurezza acqua (°C)
-----
Electrical power supply
Potenza elettrica assorbita (W)
40
Rated voltage
Tensione nominale (V)
230
Rated frequency
Frequenza nominale(Hz)
50
5

HYDRAULIC CONNECTIONS
Cooking stove 100
LEGEND
REFERENCE
DESCRIPTION
COUPLING
A
SYSTEM FLOW
3/4 “GAS
R
SYSTEM RETURN
3/4 “ GAS
B
BOILER DISCHARGE OUTLET
3/4 “ GAS
C
DOMESTIC COLD WATER INLET
1/2 “ GAS
D
DOMESTIC HOT WATER
OUTLET
1/2 “ GAS
E
BOILER DISCHARGE OUTLET
1/2 “ GAS
6

02.1 DESCRIPTION OF COMPONENTS
TRAY LID
SANITARY WATER INLET HOSE
SANITARY WATER OUTLET HOSE
AUTOMATIC RELEASE VALVE
CONDENSATE DISCHARGE PIPE 3/4
HEATING COIL
DOMESTIC WATER COIL
MAGNESIUM ANODE
FLOAT
FLOAT
SAFETY SOLENOID VALVE
SAFETY SOLENOID VALVE
CHECK VALVE
ELECTRONIC PUMP
7

ELECTRONIC CONTROL UNIT
INTERNAL DIVERTER ADJUSTMENT DEVICE
FLUE 150 mm
OVEN
INSPECTION PLATE
8

03. PRODUCT INTSTALLATION
03.1 INTRODUCTION
INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL
REGULATIONS.
Eva Stampaggi S.r.l. assumes no responsibility for injury to persons and/or damage to property caused by the non-observance of the point
highlighted above
for non-compliant installed products.
Install the stove according to the regulations in force in the country of use.
In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas:
a. preliminary activities -are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary
procedures include:
•installation site suitability verification;
•fume evacuation system suitability verification;
•external air inlet suitability verification.
At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met.
The safety conditions must be assessed with a preventive inspection.
Stoves and fireplaces are heating systems and must be installed safely and comply with the manufacturer's instructions!
b. installation -under the responsibility of the installer. In this phase the installation of the product and the smoke exhaustion system are considered as well as
the handling of topics such as:
•safety distance from combustible materials;
•chimney flue construction, smoke ducts, intubated systems and chimney cowls.
c. issuance of supplementary documentation - the responsibility of the installer.
The release of technical documentation must include:
•manual of use and maintenance of the appliance and of the components of the system (e.g smoke ducts, chimney flue, etc.);
•Photocopy or photograph of the chimney flue plate;
•system manual: (if applicable);
•Declaration of Conformity in relation to Ministerial Decree 37/08.
d. control and maintenance - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation
over time. The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in a workmanlike manner
and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with
the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who
signs a copy thereby confirming receipt and reading thereof".
In addition to what is specifically provided for in the following paragraphs of this Instruction Manual, the Purchaser must comply with the following minimum
installation requirements:
a) Do not invert or place the stove horizontally on one side;
b) The power of the stove must be adapted to the size of the room where it is to be installed and the room must be ventilated from the outside;
c) The assembly of the flue pipe must be carried out in a workmanlike manner and according to European (UNI 10683) and national regulations, local
regulations and the technical specifications and warnings contained in this Instruction Manual;
d) The smoke outlet must be connected to the flue pipe by means of telescopic fittings;
e) The diameter of the flue must be less than 150 mm.
f) The connection to the flue pipe must be made with an inclination connection of less than 45°;
g) The flue pipe must be suitably insulated;
h) The minimum length of the horizontal section must be greater than 2 metres;
i) The minimum slope of the horizontal section must be 5%;
j) The chimney and/or flue pipe must be waterproofed;
k) The flue shall not have more than two changes of direction;
l) The flue gas must be discharged directly into the flue pipe;
m) The flue gas duct must have a length of less than 6.0 m before the flue, with a maximum horizontal section of 3.0 m;
n) The flue and flue duct must not narrow in width from the initial diameter for its entire length. The initial diameter shall be that of the exhaust outlet of the
stove body;
o) The minimum value of the ventilation duct opening must be 80 cm²;
p) The distance of the flammable walls must be respected, as prescribed on the “stove data plate”;
q) The fire pit must be cleaned before each ignition of the stove.
The Buyer must not make any structural changes to the stove and must not make any operating changes to the electrical board.
Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683) and national
regulations, local regulations and assembly instructions contained in this Instruction Manual.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, towards persons or property resulting from non-compliance with the afore-
mentioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual.
Failure to comply with the installation requirements and/or tampering with the stove may result in: inadequate power and/or abnormal product behaviour, poor flue
gas draught, clogging of the fire pit, slow combustion, tank fire, overheating and fire hazard of the stove, fire hazard of the flue gas duct, lack of oxygen in the
environment where the stove is located.
Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused
by non-compliance with the requirements for installation of the stove and/or tampering with it.
The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of
such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to
persons or property, resulting from the use of the product.
Warning: in the event of a power failure or electrical blackout, the fire pit must be emptied before repeating the operation. Failure to follow this
procedure can result in the glass breaking.
9

03.2 FLUE PIPE
STOVE CHARACTERISTICS FOR SIZING OF THE FLUE PIPE
The stoves have the following characteristics:
Chimney flue draught: 12 Pa
Fume temperature: 190 °C
Flue gas mass flow: 15.3 g/s
The flue pipe is one of the key features for guaranteeing the proper functioning of the stove. Thanks to the quality of the materials, the strength, the durability, the
easy cleaning and maintenance, the best flue pipes are made of steel, either stainless steel or aluminised.
•Use telescopic joint connections to facilitate connection to the steel rigid flue pipe and counterbalance the thermal expansion of both the firebox and the
flue pipe.
•Seal the flue pipe joint connection with high temperature silicone sealant (1,000°C). Should the existing flue opening not be perfectly perpendicular to
the firebox fume outlet, use an elbow to connect them. Inclination must never exceed 45°, with respect to the vertical axis.
•No constrictions. Use 10cm-thick insulating thimbles if pipe vent passes through floors.
•The flue pipe must be insulated along its entire length. Thanks to the flue pipe insulation fume temperature will remain high optimising draught, preventing
condensation and reducing build-up of barely ignited particles along the flue pipe walls. Use proper insulating materials (glass wool, ceramic fibre, Class
A1 non-combustible materials).
•The flue pipe must be weather-proof and as linear as possible.
•Flexible and length-adjustable metal pipes may not be used.
EXISTING FLUE PIPE (TRADITIONAL)
10

Types of flue pipe
Examples of flue pipe:
INCORRECT INSTALLATION
Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall.
03.3 CHIMNEY
A properly installed chimney cowl ensures optimum stove functioning. The anti-downdraught chimney cowl consists of a number of components whose outlet
section sum always doubles the flue pipe section. Make sure the chimney cowl is at least 150cm above the roof rise so that it is fully exposed to the wind.
The chimney cowls must:
•have useful outlet section that is at least twice that of the flue pipe.
•be made in such a way as to prevent the penetration of rain or snow.
•be constructed in such a way as to ensure, in the event of winds coming from any direction, the evacuation of combustion products.
•be free of mechanical intake auxiliaries.
Steel flue pipe with
double chamber
insulated with material
resistant to 400°C.
Optimum efficiency.
Traditional clay flue pipe
with cavities. Optimal
efficiency.
Refractory flue pipe with
insulated double chamber
and external coating in
lightweight concrete.
Optimal efficiency.
Avoid flue pipes with
internal rectangular
section whose ratio
between the larger and
smaller side is greater
than 1.5. Poor efficiency
Roof pitch α
[°]
Horizontal width of reflux
zone measured from rise A
[m]
Minimum height from roof
for discharging exhaust
fumes H min =Z+0.50m
Height of reflux zone Z [m]
15
1.85
1.00
0.50
30
1.50
1.30
0.80
45
1.30
2.00
1.50
60
1.20
2.60
2.10
11

03.4 DRAUGHT
Fumes heat up during combustion, increasing their volume. Their density is therefore lower than the one of the surrounding colder air.
This difference between the inside and outside temperatures of the chimney results in a negative pressure which increases proportionally to the flue pipe length
and the temperature.
The draught must be stronger than the fume circulation resistance so that all exhaust fumes generated during combustion inside the stove are drawn upwards
through the outlet and the flue pipe. Many weather conditions affect the flue pipe functioning, such as rain, fog, snow, altitude, and wind being the most important
as it can create both negative pressure and dynamic loading.
The wind action varies depending on whether it is ascending, descending or horizontal.
•Ascending wind always results in an increased negative pressure and draught.
•Horizontal wind results in an increased negative pressure as long as the chimney cowl was properly installed.
•Descending wind always diminishes the negative pressure, sometimes inverting it.
Excess draught causes an increase in the combustion temperature and consequently a loss in stove efficiency.
A part of the combustion fumes is drawn up through the flue pipe together with small wood particles before combustion reducing stove efficiency, increasing fuel
consumption and resulting in the emission of polluting fumes.
At the same time the high fuel temperature, due to an excess amount of oxygen, wears down the combustion chamber sooner than expected.
On the other hand, poor draught slows down combustion resulting in a decrease in the stove temperature, fume spillage inside the room, a loss of stove efficiency
and dangerous build-up in the flue pipe.
In order to avoid excessive draught it is appropriate to use:
-damper -draught regulator
12

03.5 STOVE EFFICIENCY
Highly efficient stoves may pose difficulties for fume extraction.
In order for a flue pipe to work properly its internal temperature must increase as a consequence of the fumes generated during combustion.
Importantly, the efficiency of a heater is determined by its ability to transfer most of the heat produced to the environment to be heated: consequently, the greater
the efficiency of the stove, the "colder" the residual fumes of combustion, and consequently, the lower the "draft".
A traditional chimney flue, with a rough design and insulation, is more efficient if used with a traditional open fireplace or a poor-quality stove where most of the
heat is lost with the fumes.
Therefore, purchasing a quality stove often entails modifying the existing chimney flue to obtain a better insulation, even when it already works properly with old
appliances. Poor draught results in the stove not operating when hot or in smoke spillage.
Connecting the stove pipe to an existing chimney flue that has already been used with an old appliance is a common mistake. In this way two solid-fuel appliances
share the same chimney flue, which is wrong and dangerous.
If the two appliances are used simultaneously, the fume load might exceed the existing chimney flue capacity resulting in downdraught. If only one appliance is
used, the fume heat will facilitate draught but the cold air coming from the other appliance not in use will cool down exhaust fume temperature again blocking the
draught.
Besides the problems described so far, if the two appliances are placed on different levels the communicating vessel principle might be interfered with, causing
combustion fumes to be drawn in an irregular and unforeseeable way.
03.6 INSTALLATION
Follow the instructions below before installing your stove.
Select the position where the stove is to be installed and:
•Arrange the connection to the flue pipe for fume extraction.
•Provide the external air intake (combustion air) and check for its presence: it must be drawn from a free space (not spaces where extractor fans exist or
without ventilation) or from outside.
•Arrange a discharge pipe for the condensate resulting from boiling.
•If possible, install it near the hydraulic manifold or however, in a suitable position so that you can easily connect it to the hydraulic system.
•Place the stove on the floor in a convenient position for the connection to the flue pipe and close to the combustion air intake.
•The appliance must be installed on a floor with an adequate loading-bearing capacity. Should the existing floor not comply with the requirement above, proper
measurements must be taken (for instance, the installation of a load distribution plate).
•All the structures which could catch fire if exposed to excessive heat must be protected. Floors made from wood or inflammable materials must be protected
using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
•The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and flue pipe.
•This appliance is not suitable to be installed on a shared flue pipe.
•During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positioned at the same height of
the pipe located on the stove back. When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should
not be other naked flame devices in the same room.
•If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood cladding, etc.), the following minimum clearances
must be complied with:
SAFETY DISTANCE FROM COMBUSTIBLE
MATERIALS:
REAR WALL C = 0 mm
INSULATION THICKNESS C = 80 mm
SIDE WALL = 600 mm
RECESS B= 5 mm
FRONT R = 1000 mm
13

•Besides complying with the minimum clearances set above, we also recommend installing heat-resistant fireproof insulating panels (rock wool, cellular
concrete, etc.)
The following is recommended
Promasil 1000
Classification temperature: 1000 °C
Density: 245 kg/m3
Shrinkage at reference temperature, 12 h: 1.3/1000°C %
Cold crushing strength: 1.4 MPa
Bending strength: 0.5 MPa
Reversible thermal expansion: 5.4x10-6 m/mK
Specific heat capacity: 1.03 kJ/kg K
Thermal conductivity λ:
200 °C 0.07 W/mK
400 °C 0.10 W/mK
600 °C 0.14 W/mK
800 °C 0.17 W/mK
Thickness: 40 mm
•When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should not be in the same room other
naked flame devices, with the exception only of type c stoves (airtight).
•Make sure that the stove can draw the necessary quantity of combustion air: this must be from an open space (i.e. a space without exhaust blowers or
providing adequate ventilation) or directly from outside.
•Do not install the stove in bedrooms or bathrooms.
•Unpack the stove: be careful not to damage the product at the time of unpacking.
•Check the stove's legs and adjust them so that the stove is stable.
•Place the stove so that the door and any window openings are not against the walls.
•Join the coupling device to the flue pipe.
•The exhaust fume pipes must be suitable for wood-burning stoves and must therefore be made from coated steel or stainless steel, with a diameter of
150 mm and fitted with adequate seals.
CONNECTION EXAMPLES, SYSTEM DRAWINGS
Diagram 1 - Wood heating stove for the production of domestic hot water
In this type of installation, the stove works independently: the pump starts automatically when the temperature inside the stove reaches the threshold set under
parameter T1.
14

Diagram 2 - Wood-burning stove fitted with Eva Calòr boiler for the production of domestic hot water
In this case the stove will be connected to the Eva Calòr boiler. You must install a 3-way valve and a contact or a sensor that can control the valve.
Diagram 3 - Wood-burning stove fitted with boiler and separator for the production of domestic hot water
In this case the stove will be connected to a boiler. You must install a contact or a sensor to control the boiler when the stove is off.
15

Diagram 4 - Wood-burning stove with puffer and various heating sources.
In this case the stove will be connected to various sources of heat. You must install a contact or a sensor to control the various heating appliances or any valves
or pumps.
HYDRAULIC CONNECTION
The hydraulic connection of the stove must be carried out by qualified staff, who must ensure the conformity of the entire system.
Particular attention should be paid when installing the stove in an existing system (see hydraulic diagram) to make sure that it will operate in perfect safety, in
compliance with the regulation in force.
The interior of the hydraulic system must be washed before connecting the stove. You need to install a expansion tank suitable for the system and adequate safety
valves.
ATTENTION: the average flow temperature is 55°C: take this value into consideration when choosing the heating system. The maximum operating pressure is 1.5
bar.
Upstream of the hydraulic connections of the stove you should provide some gate valves so that you can disconnect it from the system if necessary.
The condensate resulting from boiling must be suitably conveyed and collected to protect the floor.
If the KIT for the production of Domestic Hot Water is installed, the water used should have suitable characteristics so as to prevent the formation of limestone
inside the exchanger; water hardness > 25° French degrees, appropriate water softener.
The manufacturer declines any liability for any damage to persons or property arising from non-compliant product installation.
ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Special attention should be paid when the stove is parts of the system and all equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system where it is connected must be fitted with a conductor as required by the Regulations 73/23 EEC and 93/98 EEC.
16

04 USING THE PRODUCT
04.1 DISPLAY
The electronic control unit installed on the stove controls the operation of the pump, of the automatic fill valve, of the sensor and of the 3-way valves installed on
the system.
Buttons:
P1- MENU/EXIT: press this button to access or exit the menus.
P2- Summer/Winter or Scroll menu: press this button to toggle between summer and winter modes. The difference between summer and winter is the pump
enabling threshold.
P3-DHW PLUS: this button stops the pump and allows for maximum production of DHW for 15 minutes.
P4- Delete alarm/confirm: press this button to silence an alarm or to confirm the menu.
Led:
L1- General Alarm: this led flashes when there are ongoing failures. The display shows the alarm type.
L2- Summer: indicates that summer mode is on.
L3- Winter: indicates that winter mode is on.
L4- AutoFill: indicates that the automatic fill valve is working.
L5- Pump: indicates that the pump is working.
L6- Valve: indicates that a 3-way valve is working.
Connections:
N POWER SUPPLY Neutral
Ph POWER SUPPLY Phase
N POWER SUPPLY Neutral
V1 PUMP V 1
N POWER SUPPLY Neutral
V2 3-WAY VALVE V2
INPUTS:
I1 Water temperature sensor (from 0 -100)
I2 External thermostat
I4 Float / level switch
OUTPUTS:
V1 Pump
V2 3-way valve with spring return
V3 Fill valve
Menu:
-User menu: the user menu contains:
•T1: PUMP THERMOSTAT: the degrees at which the pump switches on. We recommend that you do not set this parameter to less than 58°C.
•T3: 3-WAY VALVE THERMOSTAT or other user: the degrees at which the 3-way valve with spring return returns to stand-by position. It can be used to
enable a secondary pump or another user.
•BUZZER: Buzzer volume.
•DEGREES: possibility of choosing between °C and °F.
•LANGUAGE: possibility of choosing the display language between Italian and English.
•BRIGHTNESS: possibility of setting the brightness of the display.
P1
P2
P3
P4
L1
L2
L3
L4
L5
L6
17

-Technical menu: the technical menu is reserved for the cooker stove installer.
-Alarms: in this section of the menus is displayed any ongoing alarm. The alarm can be disabled by pressing the buttons P1 and P4. Alarm deletion is confirmed
by a long beep. The alarms are:
•Sensor 1 open: the sensor is not connected.
•Sensor 1 short-circuit: the sensor is damaged.
•Sensor 2 open: the sensor is not connected.
•Sensor 2 short-circuit: the sensor is damaged.
•H2O level sensor failure: if the sensor does not switch off within a given period of time T after the tank is fed with water, due to boiling or any other reason,
the stove enters the H2O level sensor failure alarm condition.
•Hot water: the temperature of the water inside the boiler exceeded the maximum threshold.
Installation with Contact (external thermostat):
For the version with contact (valid for diagram 2,3,4): the display shows the temperature of the boiler. When the contact opens, the display shows T OFF and output
V2 is powered. When the contact closes, the display shows T ON.
EXAMPLE:
When the contact opens because the boiler requires hot water, the three-way valve switches towards the boiler and the display shows T OFF. Once the stove
meets the water requirement, the contact closes and the display shows T ON.
Installation with Probe:
For the version with sensor (valid for diagram 2,3,4): the display shows the boiler temperature and the measured temperature alternately. The sensor is adjusted
by T3. Therefore, if the temperature measured by the sensor is below T3, output V2 is enabled. If the temperature measured by the sensor is above T3, the 3-way
valve returns to its stand-by position.
EXAMPLE:
If the temperature measured by the sensor is lower than T3, a 3-way valve is enabled and it switches towards the boiler. If the temperature measured by the sensor
is above T3, the 3-way valve returns to its stand-by position.
04.2 IGNITION
CHECKS BEFORE START-UP
After connecting the stove to the hydraulic system and the electrical system you need to:
•Fill the system slowly, with the cap of the automatic release valve open. The system must be filled slowly so as to allow any air bubbles to come out of
the stove exchangers.
•If necessary, bleed the radiators.
•Fill the boiler tank: you can use a container or wait for it to be filled by means of the automatic fill valve (after 5 minutes of operation of the automatic
valve, the display might show the H2O LEVEL SENSOR FAULT alarm. Reset the alarm by pressing buttons P1 and P4 at the same time).
•The water should cover the exchangers but it should not exceed the limit of the discharge pipe.
•Do not start the stove if the tank is empty: you will not be able to heat your home and you also might damage the stove.
To light the cooking stove, small (dry) logs and possibly ecological fire-lighters are required. Open the primary air register located on the front of the ash drawer
and place the wood logs. After positioning the logs, place the fire starters below the wood and light them up. Close the door and wait for the flame to reach all the
wood logs. Good ignition depends very much on the draught of your flue pipe: if the ignition is difficult, the flue pipe will not have the recommended draught due to
the fact that it is cold and the stove will require more time to reach the intended operating conditions. In this case, we recommend that you open the ash drawer or
keep the fire door slightly open. Make sure the internal fume diverter/register (if provided) is open (turn counter-clockwise).
CAUTION:
Never use flammable liquids to ignite the wood logs. Also, after turning the stove on, keep in mind to close the primary air register. If you fail to close it, the stove
might overheat and might get damaged. Also, the paint might still be fresh and it might release intense odours. Therefore, you should make sure that the room is
properly ventilated before igniting the stove for the first time. Open the doors and windows to remove any odours from the room. The product might also suffer
slight deformations as its structure is made of steel; therefore you might hear slight noises or crunches. This is absolutely normal and should not be considered a
defect.
The display is off during the ignition phase. It will turn on once the temperature of the water inside the boiler exceeds 30°C.
18

04.3 COMBUSTION
To obtain the best combustion, follow the parameters below:
Stove
Amount of wood (kg/h)
4.3 (3 logs)
Primary air register
CHECKING FOR SIGNS
Fumes div. register
Closed
Refuelling interval (min)
50
Wood log length (cm)
30
Draught (Pa)
12
Wood arrangement
See photo below
Do not introduce into the stove an amount of fuel greater than that recommended in this manual.
When reloading the wood it would be advisable to open the primary air adjustment device or even the ash drawer, slightly open the door so that the stove takes
in oxygen, load the wood and close the firebox door
CAUTION:
•Do not introduce into the stove an amount of fuel greater than that recommended in this manual.
•Don't smother the fire by closing the air vents.
•Do not leave the primary air register open during normal operation to prevent the device and the water inside the boiler from overheating, subsequently
deforming the stove.
•Do not leave the firebox door open.
•Use proper protective equipment during refuelling: the firebox door handle and the registers might be very hot when the stove is running.
•If the coals are extinguished, light them up with new wood shims to start the fire.
•It’s your job to find the perfect combination between ignition and amount of air (by adjusting the register) so that your stove functions properly, according
to the characteristics of the chimney flue and of the wood.
•The top plate has been treated with food grade Vaseline. It’s role is to protect the material against oxidation. This product is non-toxic and it will evaporate
on his own at the first ignition.
The pump starts once the water inside the boiler reaches 55 °C and makes the water circulate inside the hydraulic system through the immersed coils. We
recommend that you never set T1 at a value below 55°C to prevent the formation of condensate inside the boiler. The oven is heated by the fumes surrounding it.
After the fire is properly started, if you want to increase the temperature inside the oven you have to rotate the lever installed above the plate clockwise and close
the internal fumes diverter so that they can circulate around the oven, increasing the temperature inside it.
04.4 PRODUCTION OF DHW PLUS
The models with built-in water heating system can produce domestic hot water instantaneously. Press the P3 button if you want to use all the power of the stove
to heat water. This way, the pump will be locked for 15 minutes to prevent it from changing the heating circuit. That period may be interrupted by pressing the same
button for 5 seconds. The pump restarts automatically when the water inside the boiler exceeds 85°C.
CORRECT POSITION OF THE
ADJUSTMENT DEVICE
19

04.5 ICE ANTI-BLOCK FUNCTION
The pump cycles start automatically to ensure the perfect efficiency of the stove at any time, preventing its deterioration and any possible malfunction. When the
temperature inside the boiler drops below 6°C, the system starts the pump to prevent the formation of ice.
04.6 AUTOMATIC FILLING VALVE
Inside the stove is installed an automatic fill valve. It is enabled in the following cases:
•Low water level: the level sensor detects when there is very little water inside the boiler due to evaporation. The sensor sends a signal to the control unit
which controls the solenoid valve.
•Thermal safety: it keeps the temperature inside the boiler under control in case of overheating.
05 CLEANING AND MAINTENANCE
05.1 INTRODUCTION
The stove requires a simple yet constant cleaning to guarantee top efficiency and proper functioning.
Constant maintenance by a qualified technician is recommended.
The stove should be cleaned before the cold season because it can sometimes get clogged during the summer (by nests for example) preventing exhaust fumes
to flow regularly.
At the beginning of the season and in case of wind, a build-up of residue in the pipe may lead to fires. Should this happen, find below a few pieces of advice to
follow:
•Block air supply to the pipe immediately;
•Throw sand or kitchen salt, and not water, to extinguish fire and coals;
•Keep objects and furniture away from the burning pipe.
ALSO TO PREVENT THIS TYPE OF FAULT YEARLY CLEANING OF THE FLUE PIPE IS ESSENTIAL, REMOVING DEPOSITS OR ANY POCKETS OR
OBSTRUCTIONS.
05.2 DAILY CLEANING
Any cleaning operation must be performed when the stove is completely cold:
•Empty the ash drawer: vacuum it out or dispose of the ashes in a waste bin.
•Vacuum the combustion chamber: check that there are no embers that may still be lit. In this case your dust vacuum cleaner will catch fire.
•Remove the ash inside firebox and on door.
•Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the operation is performed with the stove hot there is a risk of the
glass exploding.
CAUTION: USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY. DO NOT USE ABRASIVE MATERIALS OR PRODUCTS THAT COULD CORRODE
OR WHITEN THE SURFACES.
05.3 MANUFACTURER’S RESPONSIBILIES
The manufacturer shall not be held liable against any direct and/or indirect, criminal and/or third party liability arising from:
•failure to abide by the instructions contained herein.
•non authorised repair operations or changes.
•use not compliant with safety rules.
•installation not compliant with national current regulations and safety rules.
•insufficient maintenance.
•the use of spare parts that are not original or which are not specific to the stove model.
06 TROUBLE-SHOOTING
•The stove does not heat: the wood is too wet or of poor quality; insufficient chimney flue draught.
•The stove heats too: excessive chimney flue draught; door or drawer gaskets replacement.
•Bottom grate locked: check the grate and make sure there are no nails or wood pieces stuck in it.
•Blackened glass: wood too wet or of poor quality, poor draught, insufficient combustion air, register closed too quick.
20
This manual suits for next models
1
Table of contents
Popular Cooker manuals by other brands

Creda
Creda HB49112 Instruction book

Smeg
Smeg OPERA A31X Function guide

Royale
Royale TT29 Installation and operating instructions

Tricity Bendix
Tricity Bendix 3000S Operating and installation instructions

Bartscher
Bartscher 1051403 Instructions for installation, operation and maintenance

Siemens
Siemens HX74X545Q instruction manual